首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 375 毫秒
1.
采用水热处理方法合成了具有不同硅铝比的超稳Y型分子筛,考察了苯、甲苯、二甲苯、苯乙烯和乙酸乙酯与水在Y分子筛表面的竞争吸附。结果表明,随着Si/Al比的增加,Y分子筛表面的有机分子选择性吸附位数量增加,有机分子竞争吸附能力增加。低硅Y型分子筛只有在吸附偶极距>1.0的高极性有机分子时才能与水分子产生有力的竞争吸附,而高硅超稳Y分子筛则对偶极距在0~0.5范围的有机分子就表现出很强的竞争吸附能力。  相似文献   

2.
Abstract

Volatile organic compounds (VOCs) are a major concern for indoor air pollution because of the impacts on human health. In recent years, interest has increased in the development and design of activated carbon filters for removing VOCs from indoor air. Although extensive information is available on sources, concentrations, and types of indoor VOCs, there is little or no information on the performance of indoor air adsorption systems for removing low concentrations of primary VOCs. Filter designs need to consider various factors such as empty bed contact time, humidity effects, competitive adsorption, and feed concentration variations, whereas adsorption capacities of the indoor VOCs at the indoor concentration levels are important parameters for filter design. A preliminary assessment of the feasibility of using adsorption filters to remove low concentrations of primary VOCs can be performed. This work relates the information (including VOC classes in indoor air, the typical indoor concentrations, and the adsorption isotherms) with the design of a particular adsorbent/adsorbates system. As groundwork for filter design and development, this study selects the primary VOCs in indoor air of residences, schools, and offices in different geographical areas (North America, Europe, and Asia) on the basis of occurrence, concentrations, and health effects. Activated carbon fiber cloths (ACFCs) are chosen as the adsorbents of interest. It is demonstrated that the isotherm of a VOC (e.g., toluene on the ACFC) at typical indoor concentrations—parts per billion by volume (ppbv) level—is different than the isotherm at parts per million by volume (ppmv) levels reported in the publications. The isotherms at the typical indoor concentrations for the selected primary VOCs are estimated using the Dubinin–Radushkevitch equation. The maximum specific throughput for an indoor VOC removal system to remove benzene is calculated as a worst-case scenario. It is shown that VOC adsorption capacity is an important indicator of a filter’s lifetime and needs to be studied at the appropriate concentration range. Future work requires better understanding of the realistic VOC concentrations and isotherms in indoor environments to efficiently utilize adsorbents.  相似文献   

3.
Jo WK  Park KH 《Chemosphere》2004,57(7):555-565
The current study evaluated the technical feasibility of applying TiO2 photocatalysis to the removal of low-ppb concentrations of volatile organic compounds (VOCs) commonly associated with non-occupational indoor air quality issues. A series of experiments was conducted to evaluate five parameters (relative humidity (RH), hydraulic diameter (HD), feeding type (FT) for VOCs, photocatalytic oxidation (PCO) reactor material (RM), and inlet port size (IPS) of PCO reactor) in relation to the PCO destruction efficiencies of the selected target VOCs. None of the target VOCs exhibited any significant dependence on the RH, which is inconsistent with a previous study where, under conditions of low humidity and a ppm toluene inlet level, a drop in the PCO efficiency was reported with a decreasing humidity. However, the other four parameters (HD, RM, FT, and IPS) were found to be important for better VOC removal efficiencies as regards the application of TiO2 photocatalytic technology for cleansing non-occupational indoor air. The PCO destruction of VOCs at concentrations associated with non-occupational indoor air quality issues was up to nearly 100%, and the CO generated during PCO was a negligible addition to indoor CO levels. Accordingly, a PCO reactor would appear to be an important tool in the effort to improve non-occupational indoor air quality.  相似文献   

4.
Shin SH  Jo WK 《Chemosphere》2012,89(5):569-578
The present study investigated the indoor concentrations of selected volatile organic compounds (VOCs) and formaldehyde and their indoor emission characteristics in newly-built apartments at the pre-occupancy stage. In total, 107 apartments were surveyed for indoor and outdoor VOC concentrations in two metropolitan cities and one rural area in Korea. A mass balanced model was used to estimate surface area-specific emission rates of individual VOCs and formaldehyde. Seven (benzene, ethyl benzene, toluene, m,p-xylene, o-xylene, n-hexane, and n-heptane) of 40 target compounds were detectable in all indoor air samples, whereas the first five were detected in all outdoor air samples. Formaldehyde was also predominant in the indoor air samples, with a high detection frequency of 96%. The indoor concentrations were significantly higher than the outdoor concentrations for aromatics, alcohols, terpenes, and ketones. However, six halogenated VOCs exhibited similar concentrations for indoor and outdoor air samples, suggesting that they are not major components emitted from building materials. It was also suggested that a certain portion of the apartments surveyed were constructed by not following the Korean Ministry of Environment guidelines for formaldehyde emissions. Toluene exhibited the highest emission rate with a median value of 138 μg m−2 h−1. The target compounds with median emission rates greater than 20 μg m−2 h−1 were toluene, 1-propanol, formaldehyde, and 2-butanone. The wood panels/vinyl floor coverings were the largest indoor pollutant source, followed by floorings, wall coverings, adhesives, and paints. The wood panels/vinyl floor coverings contributed nearly three times more to indoor VOC concentrations than paints.  相似文献   

5.
Interest in indoor air quality is steadily increasing. Exposure to volatile organic compounds (VOCs) is associated with health effects as diverse as childhood respiratory disease, lung cancer and cardiovascular disease. In an effort to assess the environmental impact indoors from possible sources of VOCs, such as (i) open oil lakes, (ii) chemical and petrochemical industries and (iii) indoor pollution from household items, concentrations of aliphatic and aromatic VOCs, comprising n-hexane to n-hexadecane, benzene, toluene, xylene, ethyl benzene, methanol and o-dichlorobenzene, were measured in indoor air samples from seven different cities in Kuwait using a gas chromatograph. The data for the period March to May 1993 are presented. The VOCs, as measured, were surprisingly low and they are below the concentrations set by the American Hygienists Association. However, although the concentration of the estimated VOCs being low, were cumulative effects of them entering the human body and water sources cannot be ruled out.  相似文献   

6.
We conducted a comparative study on the indoor air quality for Japan and China to investigate aromatic volatile organic compounds (VOCs) in indoor microenvironments (living room, bedroom, and kitchen) and outdoors in summer and winter during 2006–2007. Samples were taken from Shizuoka in Japan and Hangzhou in China, which are urban cities with similar latitudes. Throughout the samplings, the indoor and outdoor concentrations of many of the targeted VOCs (benzene, toluene, ethylbenzene, xylenes, and trimethylbenzenes) in China were significantly higher than those in Japan. The indoor concentrations of VOCs in Japan were somewhat consistent with those outdoors, whereas those in China tended to be higher than those outdoors. Here, we investigated the differences in VOC concentrations between Japan and China. Compositional analysis of indoor and outdoor VOCs showed bilateral differences; the contribution of benzene in China was remarkably higher than that in Japan. Significant correlations (p < 0.05) for benzene were observed among the concentrations in indoor microenvironments and between the outdoors and living rooms or kitchens in Japan. In China, however, significant correlations were observed only between living rooms and bedrooms. These findings suggest differences in strengths of indoor VOC emissions between Japan and China. The source characterizations were also investigated using principal component analysis/absolute principal component scores. It was found that outdoor sources including vehicle emission and industrial sources, and human activity could be significant sources of indoor VOC pollution in Japan and China respectively. In addition, the lifetime cancer risks estimated from unit risks and geometric mean indoor concentrations of carcinogenic VOCs were 2.3 × 10?5 in Japan and 21 × 10?5 in China, indicating that the exposure risks in China were approximately 10 times higher than those in Japan.  相似文献   

7.
Volatile organic compounds (VOCs) are prevalent components of indoor air pollution. Among the approaches to remove VOCs from indoor air, photocatalytic oxidation (PCO) is regarded as a promising method. This paper is a review of the status of research on PCO purification of VOCs in indoor air. The review and discussion concentrate on the preparation and coating of various photocatalytic catalysts; different kinetic experiments and models; novel methods for measuring kinetic parameters; reaction pathways; intermediates generated by PCO; and an overview of various PCO reactors and their models described in the literature. Some recommendations are made for future work to evaluate the performance of photocatalytic catalysts, to reduce the generation of harmful intermediates and to design new PCO reactors with integrated UV source and reaction surface.  相似文献   

8.
为深入了解天津市大气挥发性有机物(VOCs)来源及对O3的影响,基于2020年天津市VOCs在线监测数据,统计分析了VOCs污染特征,用主成分分析法对天津市VOCs的来源进行解析,用最大增量反应活性法分析VOCs的O3生成潜势(OFP).结果表明:2020年天津市VOCs的年均质量浓度总和为56.56μg/m3,其中,...  相似文献   

9.
Stenotrophomonas maltophilia T3-c, isolated from a biofilter for the removal of benzene, toluene, ethylbenzene, and xylene (BTEX), could grow in a mineral salt medium containing toluene, benzene, or ethylbenzene as the sole source of carbon. The effect of environmental factors such as initial toluene mass, medium pH, and temperature on the degradation rate of toluene was investigated. The cosubstrate interactions in the BTEX mixture by the isolate were also studied. Within the range of initial toluene mass (from 23 to 70 pmol), an increased substrate concentration increased the specific degradation of toluene by S. maltophilia T3-c. The toluene degradation activity of S. maltophilia T3-c could be maintained at a broad pH range from 5 to 8. The rates at 20 and 40 degrees C were 43 and 83%, respectively, of the rate at 30 degrees C. The specific degradation rates of toluene, benzene, and ethylbenzene by strain T3-c were 2.38, 4.25, and 2.06 micromol/g-DCW/hr. While xylene could not be utilized as a growth substrate by S. maltophilia T3-c, the presence of toluene resulted in the cometabolic degradation of xylene. The specific degradation rate of toluene was increased by the presence of benzene, ethylbenzene, or xylene in binary mixtures. The presence of toluene or xylene in binary mixtures with benzene increased the specific degradation rate of benzene. The presence of ethylbenzene in binary mixtures with benzene inhibited benzene degradation. The presence of more than three kinds of substrates inhibited the specific degradation rate of benzene. All BTEX mixtures, except tri-mixtures of benzene, ethylbenzene, and xylene or mixtures of all four substrates, had little effect on the degradation of ethylbenzene by S. maltophilia T3-c. The utilization preference of the substrates by S. maltophilia T3-c was as follows: ethylbenzene was degraded fastest, followed by toluene and benzene. However, the specific degradation rates of substrates, in order, were benzene, toluene, and ethylbenzene.  相似文献   

10.
An improved photocatalytic oxidation (PCO) reactor model was developed to analyze the removal of volatile organic compounds (VOCs) in indoor air. One new parameter, the average total removing factor Kt, together with the other two parameters, the number of mass transfer units NTUm and the fractional conversion epsilon, are found to be the main parameters influencing the photooxidation performance of PCO reactors. Three new parameters, the ideal reaction number of mass transfer units, NTUm,ir; the ideal reaction fractional conversion, epsilonir; and the reaction effectiveness, eta, also are defined. These concepts are helpful to the structural design and optimization for PCO reactors. The application of the model in designing a plate-type PCO reactor is demonstrated. This study shows that the present model is an effective tool for designing PCO reactors and for evaluating VOC removal performance of available PCO reactors.  相似文献   

11.
依据介质阻挡放电(DBD)和溶液吸收处理气态污染物的原理,设计出一种DBD和水吸收联合降解挥发性有机化合物(VOCs)的实验装置.研究其对甲苯的降解效果.考察了放电电压、甲苯初始浓度、模拟废气流量对甲苯降解效果的影响.分析了DBD和水吸收的相互作用.结果表明.DBD和水吸收联合可以提高甲苯的降解率.在放电电压为15.9 kV时甲苯的降解率为81.5%.比单独放电时提高了13.3百分点;甲苯的降解率随着放电电压增大而升高,随着气体流量和甲苯初始浓度增大而降低.该技术可以作为放电等离子体前处理工艺,为高效处理上业废气提供参考.  相似文献   

12.
Bioprocesses, such as biofiltration, are commonly used to treat industrial effluents containing volatile organic compounds (VOCs) at low concentrations. Nevertheless, the use of biofiltration for indoor air pollution (IAP) treatment requires adjustments depending on specific indoor environments. Therefore, this study focuses on the convenience of a hybrid biological process for IAP treatment. A biofiltration reactor using a green waste compost was combined with an adsorption column filled with activated carbon (AC). This system treated a toluene-micropolluted effluent (concentration between 17 and 52 µg/m3), exhibiting concentration peaks close to 733 µg/m3 for a few hours per day. High removal efficiency was obtained despite changes in toluene inlet load (from 4.2 × 10?3 to 0.20 g/m3/hr), which proves the hybrid system’s effectiveness. In fact, during unexpected concentration changes, the efficiency of the biofilter is greatly decreased, but the adsorption column maintains the high efficiency of the entire process (removal efficiency [RE] close to 100%). Moreover, the adsorption column after biofiltration is able to deal with the problem of the emission of particles and/or microorganisms from the biofilter.
ImplicationsIndoor air pollution is nowadays recognized as a major environmental and health issue. This original study investigates the performance of a hybrid biological process combining a biofilter and an adsorption column for removal of indoor VOCs, specifically toluene.  相似文献   

13.
Volatile organic compounds such as benzene, toluene, butyl acetate, ethylbenzene, m-xylene, styrene and m-dichlorobenzene were measured in three newly erected and remodelled dwellings. The present study also attempted to examine the time dependence of concentrations of selected VOCs in each investigated dwelling. This was accomplished by at least triplicate measurements of the IAQ. To collect a series of air samples the active and passive methods were used. In both cases activated charcoal was applied as a sorption medium. The samples were recovered by solvent extraction, and analysed by capillary column gas chromatography, employing a flame ionisation detector. The experimental results showed that MAC values for analysed VOCs were exceeded (even a few orders of magnitude) for the measurements made before inhabiting of the occupants, in every investigated dwelling. The concentrations of the investigated VOCs decreased significantly with time, which should be expected, although in some cases the levels of selected VOCs remained still high. Our experience indicates that parallel application of two different indoor air sampling techniques to determine analytes of interest, though more laborious and time consuming, can lead to significant conclusions concerning indoor air quality in monitored spaces.  相似文献   

14.
Volatile organic compounds (VOCs) are found in indoor air, and many of these can affect human health (e.g. formaldehyde and benzene are carcinogenic). Plants affect the levels of VOCs in indoor environments, thus they represent a potential green solution for improving indoor air quality that at the same time can improve human health. This article reviews scientific studies of plants’ ability to remove VOCs from indoor air. The focus of the review is on pathways of VOC removal by the plants and factors affecting the efficiency and rate of VOC removal by plants. Laboratory based studies indicate that plant induced removal of VOCs is a combination of direct (e.g. absorption) and indirect (e.g. biotransformation by microorganisms) mechanisms. They also demonstrate that plants’ rate of reducing the level of VOCs is influenced by a number of factors such as plant species, light intensity and VOC concentration. For instance, an increase in light intensity has in some studies been shown to lead to an increase in removal of a pollutant. Studies conducted in real-life settings such as offices and homes are few and show mixed results.  相似文献   

15.
Jo WK  Lee JH  Kim MK 《Chemosphere》2008,70(10):1827-1834
The present study investigated the emission characteristics of gel-type air fresheners (AFs), using head-space, small-chamber, and in-vehicle tests. Five toxic or hazardous analytes were found in the headspace phase of AFs (toluene, benzene, ethyl benzene, and m,p-xylene) at a frequency of more than 50%. Limonene and linalool, which are known to be unsaturated ozone-reactive VOCs, were detected at a frequency of 58 and 35%, respectively. The empirical model fitted well with the time-series concentrations in the chamber, thereby suggesting that the empirical model was suitable for testing emissions. Limonene exhibited the highest emission rate, followed by m,p-xylene, toluene, ethyl benzene, and benzene. For most target VOCs, higher air change per hour (ACH) levels exhibited increased emission rates. In contrast, higher ACH levels resulted in lower chamber concentrations. The mean concentration of limonene was significantly higher in passenger cars with an AF than without. For other target compounds, there were no significant differences between the two conditions tested. Consequently, it was suggested that unlike limonene, the emission strength for aromatic compounds identified in the chamber tests was not strong enough to elevate in-vehicle levels.  相似文献   

16.
Wan-Kuen Jo  Chang-Hee Yang   《Chemosphere》2009,77(2):236-241
Unlike previous photocatalytic oxidation (PCO) studies incorporated with adsorption, this study investigates the feasibility of applying a tandem PCO-adsorption hybrid technique regarding low-level monoaromatic compound removal. The PCO efficiencies decreased as the hydraulic diameter (HD) increased. A PCO reactor of a medium HD size was selected for further experiments. Under conditions relevant to the use of the PCO system, the CO level measured during the PCO process was minimal in comparison to indoor CO levels. Trace level formations of formaldehyde and acetaldehyde were observed during the photocatalytic process, but these compounds were undetectable at the activated carbon unit outlet. The degradation efficiencies, obtained from the PCO unit, exhibited a dependence on both the inlet concentration (IC) and relative humidity (RH), whereas those from the PCO-adsorption hybrid system did not. Under specific conditions, the PCO unit presented a high degradation efficiency of close to, or exceeding 90%, in regards to ethyl benzene, o-xylene, and m,p-xylene. However, the benzene air concentrations, after being treated by the PCO unit, substantially exceeded the USEPA inhalation reference concentration guideline of 30 μg m−3 (corresponding to 0.01 ppm). In contrast, the PCO-adsorption hybrid system presented a high removal efficiency of close to 100% regarding all compounds, regardless of the IC or RH range. Consequently, it is suggested that the PCO-adsorption hybrid system has a synergistic advantage of photocatalysis and adsorption in regards to the BTEX elimination process.  相似文献   

17.
Volatile organic compounds (VOCs) in urban atmosphere of Hong Kong   总被引:21,自引:0,他引:21  
Lee SC  Chiu MY  Ho KF  Zou SC  Wang X 《Chemosphere》2002,48(3):375-382
The assessment of volatile organic compounds (VOCs) has become a major issue of air quality network monitoring in Hong Kong. This study is aimed to identify, quantify and characterize volatile organic compounds (VOCs) in different urban areas in Hong Kong. The spatial distribution, temporal variation as well as correlations of VOCs at five roadside sampling sites were discussed. Twelve VOCs were routinely detected in urban areas (Mong Kok, Kwai Chung, Yuen Long and Causeway Bay). The concentrations of VOCs ranged from undetectable to 1396 microg/m3. Among all of the VOC species, toluene has the highest concentration. Benzene, toluene, ethylbenzene and xylenes (BTEX) were the major constituents (more than 60% in composition of total VOC detected), mainly contributed from mobile sources. Similar to other Asian cities, the VOC levels measured in urban areas in Hong Kong were affected both by automobile exhaust and industrial emissions. High toluene to benzene ratios (average T/B ratio = 5) was also found in Hong Kong as in other Asian cities. In general, VOC concentrations in the winter were higher than those measured in the summer (winter to summer ratio > 1). As toluene and benzene were the major pollutants from vehicle exhausts, there is a necessity to tighten automobile emission standards in Hong Kong.  相似文献   

18.
Information of volatile organic compounds (VOCs) in buildings in Hong Kong is relatively scared compared to other countries. Information of how much VOC accumulation comes from occupants themselves, from building materials and other outdoor sources are scarce even on a global basis. This study aimed at collecting information of the levels of individual VOCs using US-EPA Method TO-14. Twenty building premises including offices and public places such as customer service centers, shopping centers, etc. were studied. Samples were taken during the time slots when the mechanical ventilation system was operating. The 43 VOCs were grouped into three categories, i.e. aromatic hydrocarbons, chlorinated hydrocarbons and organohalogen. The most dominant VOCs found in the indoor samples were benzene, toluene, ethylbenzene, xylenes (BETX), chloroform and trichloroethylene as 100% of the samples were found to contain these VOCs. Besides, more than 75% of the samples were found to contain 1,3,5-trimethylbenzene, methylchloride and dichloromethane. The wt% of chlorinated hydrocarbons (48%) and the wt% of aromatic hydrocarbons (38%) only differed by about 10% in the office sector. Organohalogen (14%) contributed to the smallest fraction of the total on all the premises in the office sector on weight basis. A completely different distribution pattern was found in the non-office sector. The most abundant class of VOCs in terms of weight was aromatic hydrocarbons (80%). The second abundant class of VOCs was chlorinated hydrocarbons (14%) and was much less than the level of aromatic hydrocarbons in terms of weight. Organohalogen (6%) contributed to the smallest fraction of the total on all the premises in the non-office sector on weight basis.  相似文献   

19.
光催化降解模拟室内挥发性有机污染物研究   总被引:4,自引:1,他引:3  
用浸渍-提拉法制备玻璃弹簧负载型TiO2薄膜催化剂,在自制的反应器中进行光催化降解由丙酮、甲苯、对二甲苯组成的模拟室内挥发性有机污染物VOCs研究.研究发现:催化剂中掺杂金属离子能影响催化剂的降解效果,降解效果依次为掺铈TiO2>纯TiO2>掺银TiO2;气体流量显著影响降解效果,丙酮、甲苯和对二甲苯的最佳降解流量分别为3、5、7 L/min;混合气体中非对称性的极性分子的降解效率高于对称性分子,导致丙酮、对二甲苯组分降解率降低,甲苯降解率增高.  相似文献   

20.
Volatile organic compounds (VOCs) are the cause of indoor air pollution and are readily emitted from furniture and cleaning agents. In Taiwan, the concentrations of indoor VOCs range roughly from 1 to 10 ppm. It is important to effectively reduce indoor VOC emissions and establish the implementation of long-term, low-cost, controlled techniques such as those found in the ultraviolet/titanium dioxide (UV/TiO2) control systems. This study evaluates the performance of a photoreactor activated by visible irradiation and packed with TiO2/quartz or TiO2/mobile catalytic material number 41 (MCM-41). The photocatalysts tested include commercial TiO2 (Degussa P-25) and synthesized TiO2 with a modified sol-gel process. The UV light had a wavelength of 365 nm and contained an 8-W, low-pressure mercury lamp. Reactants and products were analyzed quantitatively by using gas chromatography with a flame-ionization detector. It is important to understand the influence of such operational parameters, such as concentration of pollutant, temperature, and retention time of processing. The indoor concentrations of VOCs varied from 2 to 10 ppm. Additionally, the temperatures ranged from 15 to 35 degrees C and the retention time tested from 2 to 8.2 sec. The results show that quartz with TiO2 had a better photoreductive efficiency than quartz with MCM-41. The toluene degradation efficiency of 77.4% with UV/TiO2/quartz was larger than that of 54.4% with the UV/TiO2/MCM-41 system under 10-min reaction time. The degradation efficiency of the UV/TiO2 system decreased with the increasing concentrations of indoor VOCs. The toluene degradation efficiency at 2 ppm was approximately 5 times greater than that at 10 ppm. The photoreduction rate of the VOCs was also evaluated with the Langmuir-Hinshewood model and was shown to be pseudo-first-order kinetics.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号