首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Improper solid waste management leads to aesthetic and environmental problems. Emission ofvolatile organic compounds (VOCs) is one of the problems from uncontrolled dumpsite. VOCs are well known to be hazardous to human health and many of them are known or potential carcinogens. They also contribute to ozone formation at ground level and climate change as well. The qualitative and quantitative analysis of VOCs emitting from two municipal waste (MSW) disposal sites in Mumbai, India, namely Deonar and Malad, are presented in this paper. Air at dumpsites was sampled and analyzed on gas chromatography-mass spectrometry (GC-MS) in accordance with U.S. Environmental Protection Agency (EPA) TO-17 compendium method for analysis of toxic compounds. As many as 64 VOCs were qualitatively identified, among which 13 are listed under hazardous air pollutants (HAPs). Study of environmental distribution of a few major VOCs indicates that although air is the principal compartment of residence, they also get considerably partitioned in soil and vegetation. The CO2 equivalent of target VOCs from the landfills in Malad and Deonar shows that the total yearly emissions are 7.89E+03 and 8.08E+02 kg, respectively. The total per hour ozone production from major VOCs was found to be 5.34E-01 ppb in Deonar and 9.55E-02 ppb in Malad. The total carcinogenic risk for the workers in the dumpsite considering all target HAPs are calculated to be 275 persons in 1 million in Deonar and 139 persons in 1 million in Malad.  相似文献   

2.
Improper solid waste management leads to aesthetic and environmental problems. Emission of volatile organic compounds (VOCs) is one of the problems from uncontrolled dumpsite. VOCs are well known to be hazardous to human health and many of them are known or potential carcinogens. They also contribute to ozone formation at ground level and climate change as well. The qualitative and quantitative analysis of VOCs emitting from two municipal waste (MSW) disposal sites in Mumbai, India, namely Deonar and Malad, are presented in this paper. Air at dumpsites was sampled and analyzed on gas chromatography–mass spectrometry (GC-MS) in accordance with U.S. Environmental Protection Agency (EPA) TO-17 compendium method for analysis of toxic compounds. As many as 64 VOCs were qualitatively identified, among which 13 are listed under Hazardous Air Pollutants (HAPs). Study of environmental distribution of a few major VOCs indicates that although air is the principal compartment of residence, they also get considerably partitioned in soil and vegetation. The CO2 equivalent of target VOCs from the landfills in Malad and Deonar shows that the total yearly emissions are 7.89E+03 and 8.08E+02 kg, respectively. The total per hour ozone production from major VOCs was found to be 5.34E-01 ppb in Deonar and 9.55E-02 ppb in Malad. The total carcinogenic risk for the workers in the dumpsite considering all target HAPs are calculated to be 275 persons in 1 million in Deonar and 139 persons in 1 million in Malad.

Implications: This paper describes the hazards of VOC emission from open dumpsites, a common practice, in an Indian metro city. The subsequent partitioning of the emitted VOCs in other environmental compartment from air is presented. The global warming potential and the health hazards to the dumpsite workers from the emitted VOCs have also been estimated.  相似文献   

3.
Jo WK  Park KH 《Chemosphere》2004,57(7):555-565
The current study evaluated the technical feasibility of applying TiO2 photocatalysis to the removal of low-ppb concentrations of volatile organic compounds (VOCs) commonly associated with non-occupational indoor air quality issues. A series of experiments was conducted to evaluate five parameters (relative humidity (RH), hydraulic diameter (HD), feeding type (FT) for VOCs, photocatalytic oxidation (PCO) reactor material (RM), and inlet port size (IPS) of PCO reactor) in relation to the PCO destruction efficiencies of the selected target VOCs. None of the target VOCs exhibited any significant dependence on the RH, which is inconsistent with a previous study where, under conditions of low humidity and a ppm toluene inlet level, a drop in the PCO efficiency was reported with a decreasing humidity. However, the other four parameters (HD, RM, FT, and IPS) were found to be important for better VOC removal efficiencies as regards the application of TiO2 photocatalytic technology for cleansing non-occupational indoor air. The PCO destruction of VOCs at concentrations associated with non-occupational indoor air quality issues was up to nearly 100%, and the CO generated during PCO was a negligible addition to indoor CO levels. Accordingly, a PCO reactor would appear to be an important tool in the effort to improve non-occupational indoor air quality.  相似文献   

4.
Jo WK  Lee JH  Kim MK 《Chemosphere》2008,70(10):1827-1834
The present study investigated the emission characteristics of gel-type air fresheners (AFs), using head-space, small-chamber, and in-vehicle tests. Five toxic or hazardous analytes were found in the headspace phase of AFs (toluene, benzene, ethyl benzene, and m,p-xylene) at a frequency of more than 50%. Limonene and linalool, which are known to be unsaturated ozone-reactive VOCs, were detected at a frequency of 58 and 35%, respectively. The empirical model fitted well with the time-series concentrations in the chamber, thereby suggesting that the empirical model was suitable for testing emissions. Limonene exhibited the highest emission rate, followed by m,p-xylene, toluene, ethyl benzene, and benzene. For most target VOCs, higher air change per hour (ACH) levels exhibited increased emission rates. In contrast, higher ACH levels resulted in lower chamber concentrations. The mean concentration of limonene was significantly higher in passenger cars with an AF than without. For other target compounds, there were no significant differences between the two conditions tested. Consequently, it was suggested that unlike limonene, the emission strength for aromatic compounds identified in the chamber tests was not strong enough to elevate in-vehicle levels.  相似文献   

5.
Abstract

Solid multisorbent packings have been characterized for trapping and release efficiency of trace (10-20 ppbv in humidified zero air) volatile organic compounds (VOCs). The use of a two-stage trapping system reduces sample water content typically by more than 95.5% while maintaining a trapping and release efficiency of 100% for 49 VOCs, including eight water-soluble VOCs. Three combinations of primary tube and focusing tube are examined in detail by using an atomic emission detector to monitor hydrogen as an indication of residual water vapor, and to monitor either chlorine, bromine, or carbon for target VOCs. Linearity of response to individual VOCs, the presence of artifacts, and a laboratory monitoring application are also discussed.  相似文献   

6.
Zou SC  Lee SC  Chan CY  Ho KF  Wang XM  Chan LY  Zhang ZX 《Chemosphere》2003,51(9):1015-1022
Ambient air monitoring was conducted at Datianshan landfill, Guangzhou, South China in 1998 to investigate the seasonal and horizontal variations of trace volatile organic compounds (VOCs). Twelve sampling points over the Datianshan landfill were selected and samples were collected simultaneously using Carbontrap(TM) adsorption tubes. Thirty eight VOCs were detected in the winter, whereas 60 were detected in the summer. The VOC levels measured in summer were alkanes, 0.5-6.5 microg/m(3); aromatics, 2.3-1667 microg/m(3); chlorinated species, 0.2-31 microg/m(3); terpines, 0.1-34 microg/m(3); carbonyl species, 0.3-5.6 microg/m(3) and naphthalene and its derivatives, 0.4-27 microg/m(3). Compared to the summer samples the VOC levels in winter were much lower (mostly 1-2 orders of magnitude lower). The aromatics are dominant VOCs in landfill air both in winter and summer. High levels of alkylbenzene and terpines such as methyl-isopropylbenzene (max 1667 microg/m(3)) and limonene (max 162 microg/m(3)) cause undesirable odor. The similar correlation coefficients of BTEX in summer and winter suggest VOCs emissions were from landfill site sources. The variation of BTEX ratio at landfill site is different from that in the urban area of Guangzhou. It shows that the ambient VOCs at landfill site were different from the urban areas.  相似文献   

7.
Abstract

Volatile organic compounds (VOCs) are a major concern for indoor air pollution because of the impacts on human health. In recent years, interest has increased in the development and design of activated carbon filters for removing VOCs from indoor air. Although extensive information is available on sources, concentrations, and types of indoor VOCs, there is little or no information on the performance of indoor air adsorption systems for removing low concentrations of primary VOCs. Filter designs need to consider various factors such as empty bed contact time, humidity effects, competitive adsorption, and feed concentration variations, whereas adsorption capacities of the indoor VOCs at the indoor concentration levels are important parameters for filter design. A preliminary assessment of the feasibility of using adsorption filters to remove low concentrations of primary VOCs can be performed. This work relates the information (including VOC classes in indoor air, the typical indoor concentrations, and the adsorption isotherms) with the design of a particular adsorbent/adsorbates system. As groundwork for filter design and development, this study selects the primary VOCs in indoor air of residences, schools, and offices in different geographical areas (North America, Europe, and Asia) on the basis of occurrence, concentrations, and health effects. Activated carbon fiber cloths (ACFCs) are chosen as the adsorbents of interest. It is demonstrated that the isotherm of a VOC (e.g., toluene on the ACFC) at typical indoor concentrations—parts per billion by volume (ppbv) level—is different than the isotherm at parts per million by volume (ppmv) levels reported in the publications. The isotherms at the typical indoor concentrations for the selected primary VOCs are estimated using the Dubinin–Radushkevitch equation. The maximum specific throughput for an indoor VOC removal system to remove benzene is calculated as a worst-case scenario. It is shown that VOC adsorption capacity is an important indicator of a filter’s lifetime and needs to be studied at the appropriate concentration range. Future work requires better understanding of the realistic VOC concentrations and isotherms in indoor environments to efficiently utilize adsorbents.  相似文献   

8.
Indoor air pollution caused by volatile organic compounds (VOCs) may affect the health and well-being of inhabitants. Uptake and release of these compounds by and from indoor materials alter their concentrations in indoor air: uptake will lower peak concentrations, whereas subsequent (slow) release at lower concentration levels will prolong the presence of VOCs in indoor air. An experimental set-up has been implemented where indoor materials are placed as a “membrane” separating two air compartments. Both compartments – consisting of Field and Laboratory Emission Cells FLECs – are constantly flushed with air, one air stream containing a mixture of 20 VOCs, and concentrations in both compartments are measured after 1 h. Ten materials usually covering extensive surfaces indoors were consecutively exposed to the vapour mixture at concentration levels typically found in indoor environments. Under the chosen experimental conditions, five of these materials exhibited a permeability high enough that VOCs could be detected on the other side. Mass transport of VOCs into and through indoor materials has therefore been confirmed by experiment. The set-up allows for a quick screening of indoor materials with respect to their sorption capacity and permeability.  相似文献   

9.
Intensive field investigations were conducted at the summit of Mount Tai in June 2006 to understand the effects of the local and regional sources on atmospheric volatile organic compounds (VOCs) distributions. A total of 60 samples were collected and determined by quantitative analytical methods. The concentrations of the total VOCs (TVOCs) observed in the air of Mount Tai were 6.95 ± 5.71 ppb. Aromatic hydrocarbons provided the largest contribution to TVOCs, followed by alkanes and halocarbons. High levels of halocarbons accounted for 20% of TVOCs due to emission from a PVC plant located at the foot of Mount Tai. Alkenes and cycloalkanes contributed little to the total VOCs. The day-and-night differences and day-to-day variations in the concentrations of four selected species were investigated and the effects of several factors such as meteorological parameters, sources and transport characteristics on them were discussed in details. A back trajectory analysis showed that relatively higher levels of VOCs were related to long-range transport of pollutants from polluted areas. The vertical motions of air masses also had a large impact on the variations of the levels of VOCs. The result of the variability–lifetime relationships of VOCs, which is used to estimate the remoteness of the sampling location, showed that Mount Tai represents intermediate conditions between remote sites and sites in the vicinity of sources.  相似文献   

10.
Risk factors for increased BTEX exposure in four Australian cities   总被引:2,自引:0,他引:2  
Benzene, toluene, ethylbenzene and xylenes (BTEX) are common volatile organic compounds (VOCs) found in urban airsheds. Elevated levels of VOCs have been reported in many airsheds at many locations, particularly those associated with industrial activity, wood heater use and heavy traffic. Exposure to some VOCs has been associated with health risks. There have been limited investigations into community exposures to BTEX using personal monitoring to elucidate the concentrations to which members of the community may be exposed and the main contributors to that exposure. In this cross sectional study we investigated BTEX exposure of 204 non-smoking, non-occupationally exposed people from four Australian cities. Each participant wore a passive BTEX sampler over 24h on five consecutive days in both winter and summer and completed an exposure source questionnaire for each season and a diary for each day of monitoring. The geometric mean (GM) and range of daily BTEX concentrations recorded for the study population were benzene 0.80 (0.04-23.8 ppb); toluene 2.83 (0.03-2120 ppb); ethylbenzene 0.49 (0.03-119 ppb); and xylenes 2.36 (0.04-697 ppb). A generalised linear model was used to investigate significant risk factors for increased BTEX exposure. Activities and locations found to increase personal exposure included vehicle repair and machinery use, refuelling of motor vehicles, being in an enclosed car park and time spent undertaking arts and crafts. A highly significant difference was found between the mean exposures in each of the four cities, which may be explained by differences in fuel composition, differences in the mix and density of industry, density of motor vehicles and air pollution meteorology.  相似文献   

11.
VOC concentration characteristics in Southern Taiwan   总被引:7,自引:0,他引:7  
Hsieh CC  Tsai JH 《Chemosphere》2003,50(4):545-556
The field investigations were conducted at four air quality monitoring sites in Southern Taiwan during northeasterly prevailing monsoon to collect 160 data sets on volatile organic compounds (VOCs) to evaluate the ozone formation potential (OFP) of the air mass. The gas chromatograph and high performance liquid chromatography analyzed 58 VOCs and two aldehydes, respectively. Among the four sampling sites, the order of the five VOC classes based on the reactivity approach was different from the concentration-based method. Alkenes as well as aromatics provided a major contribution for the OFP. The relative ranking of the species at the four sites were quite dissimilar. Toluene was the most in abundance at each site. The most abundant species at the windward and leeward sites was different. The reactivity of the air mass at the leeward sites showed a similar pattern and had higher reactivity than the windward sites. Comparisons of the two ratios, xylene/benzene and toluene/benzene were used to assess the relative age of the air parcels and provide evidence of transport.  相似文献   

12.
The availability of reliable, accurate and precise monitoring methods for toxic volatile organic compounds (VOCs) is a primary need for state and local agencies addressing daily monitoring requirements related to odor complaints, fugitive emissions, and trend monitoring. The canister-based monitoring method for VOCs is a viable and widely used approach that is based on research and evaluation performed over the past several years. This activity has involved the testing of sample stability of VOCs in canisters and the design of time-integrative samplers. The development of procedures for analysis of samples in canisters, including the procedure for VOC preconcentration from whole air, the treatment of water vapor in the sample, and the selection of an appropriate analytical finish has been accomplished. The canister-based method was initially summarized in the EPA Compendium of Methods for the Determination of Toxic Organic Compounds in Ambient Air as Method TO-14. Modifications and refinements are being added to Method TO-14 in order to obtain a Statement of Work for the Superfund Contract Laboratory Program for Air. This paper discusses the developments leading to the current status of the canisterbased method and provides a critique of the method using results obtained in EPA monitoring networks.  相似文献   

13.
Volatile organic compounds (VOCs) are found in indoor air, and many of these can affect human health (e.g. formaldehyde and benzene are carcinogenic). Plants affect the levels of VOCs in indoor environments, thus they represent a potential green solution for improving indoor air quality that at the same time can improve human health. This article reviews scientific studies of plants’ ability to remove VOCs from indoor air. The focus of the review is on pathways of VOC removal by the plants and factors affecting the efficiency and rate of VOC removal by plants. Laboratory based studies indicate that plant induced removal of VOCs is a combination of direct (e.g. absorption) and indirect (e.g. biotransformation by microorganisms) mechanisms. They also demonstrate that plants’ rate of reducing the level of VOCs is influenced by a number of factors such as plant species, light intensity and VOC concentration. For instance, an increase in light intensity has in some studies been shown to lead to an increase in removal of a pollutant. Studies conducted in real-life settings such as offices and homes are few and show mixed results.  相似文献   

14.
Determination of volatile organic compounds (VOCs) formed one part of the EU-EXPOLIS project in which the exposure of European urban populations to particles and gaseous pollutants was studied. The EXPOLIS study concentrated on 30 target VOCs selected on the basis of environmental and health significance and usability of the compounds as markers of pollution sources. In the project, 201 subjects in Helsinki, 50 in Athens, 50 in Basel, 50 in Milan and, 50 in Oxford and 50 in Prague were selected for the final exposure sample. The microenvironmental and personal exposure concentrations of VOCs were the lowest in Helsinki and Basel, while the highest concentrations were measured in Athens and Milan; Oxford and Prague were in between. In all cities, home indoor air was the most significant exposure agent. Workplace indoor air concentrations measured in this study were generally lower than the home indoor concentrations and home outdoor air played a minor role as an exposure agent. When estimating the measured personal exposure concentrations using the measured concentrations and time fractions spent at home indoors, at home outdoors, and at the workplace, it could be concluded that these three microenvironments do not fully explain the personal exposure. Other important sources for personal exposure must be encountered, the most important being traffic/transportation and other indoor environments not measured in this study.  相似文献   

15.
Volatile organic compounds such as benzene, toluene, butyl acetate, ethylbenzene, m-xylene, styrene and m-dichlorobenzene were measured in three newly erected and remodelled dwellings. The present study also attempted to examine the time dependence of concentrations of selected VOCs in each investigated dwelling. This was accomplished by at least triplicate measurements of the IAQ. To collect a series of air samples the active and passive methods were used. In both cases activated charcoal was applied as a sorption medium. The samples were recovered by solvent extraction, and analysed by capillary column gas chromatography, employing a flame ionisation detector. The experimental results showed that MAC values for analysed VOCs were exceeded (even a few orders of magnitude) for the measurements made before inhabiting of the occupants, in every investigated dwelling. The concentrations of the investigated VOCs decreased significantly with time, which should be expected, although in some cases the levels of selected VOCs remained still high. Our experience indicates that parallel application of two different indoor air sampling techniques to determine analytes of interest, though more laborious and time consuming, can lead to significant conclusions concerning indoor air quality in monitored spaces.  相似文献   

16.
The emissions from five commonly used building products were studied in small-scale test chambers over a period of 50 days. The odor intensity was assessed by a sensory panel and the concentrations of selected volatile organic compounds (VOCs) of concern for the indoor air quality were measured. The building products were three floor coverings: PVC, floor varnish on beechwood parquet and nylon carpet on a latex foam backing; an acrylic sealant, and a waterborne wall paint on gypsum board. The impacts of the VOC concentration in the air and the air velocity over the building products on the odor intensity and on the emission rate of VOCs were studied. The emission from each building product was studied under two or three different area-specific ventilation rates, i.e. different ratios of ventilation rate of the test chamber and building product area in the test chamber. The air velocity over the building product samples was adjusted to different levels between 0.1 and 0.3 m s-1. The origin of the emitted VOCs was assessed in order to distinguish between primary and secondary emissions. The results show that it is reasonable after an initial period of up to 14 days to consider the emission rate of VOCs of primary origin from most building products as being independent of the concentration and of the air velocity. However, if the building product surface is sensitive to oxidative degradation, increased air velocity may result in increased secondary emissions. The odor intensity of the emissions from the building products only decayed modestly over time. Consequently, it is recommended to use building products which have a low impact on the perceived air quality from the moment they are applied. The odor indices (i.e. concentration divided by odor threshold) of primary VOCs decayed markedly faster than the corresponding odor intensities. This indicates that the secondary emissions rather than the primary emissions, are likely to affect the perceived air quality in the long run. Some of the building products continued to affect the perceived air quality despite the concentrations of the selected VOCs resulted in odor indices less than 0.1. Therefore, odor indices less than 0.1 as an accept criterion cannot guarantee that a building product has no impact on the perceived air quality.  相似文献   

17.
Nowadays, the heating, ventilation, and air conditioning (HVAC) system has been an important facility for maintaining indoor air quality. However, the primary function of typical HVAC systems is to control the temperature and humidity of the supply air. Most indoor air pollutants, such as volatile organic compounds (VOCs), cannot be removed by typical HVAC systems. Thus, some air handling units for removing VOCs should be added in typical HVAC systems. Among all of the air cleaning techniques used to remove indoor VOCs, photocatalytic oxidation is an attractive alternative technique for indoor air purification and deodorization. The objective of this research is to investigate the VOC removal efficiency of the photocatalytic filter in a HVAC system. Toluene and formaldehyde were chosen as the target pollutants. The experiments were conducted in a stainless steel chamber equipped with a simplified HVAC system. A mechanical filter coated with Degussa P25 titania photocatalyst and two commercial photocatalytic filters were used as the photocatalytic filters in this simplified HVAC system. The total air change rates were controlled at 0.5, 0.75, 1, 1.25, and 1.5 hr(-1), and the relative humidity (RH) was controlled at 30%, 50%, and 70%. The ultraviolet lamp used was a 4-W, ultraviolet-C (central wavelength at 254 nm) strip light bulb. The first-order decay constant of toluene and formaldehyde found in this study ranged from 0.381 to 1.01 hr(-1) under different total air change rates, from 0.34 to 0.433 hr(-1) under different RH, and from 0.381 to 0.433 hr(-1) for different photocatalytic filters.  相似文献   

18.
Volatile organic compounds in selected micro-environments   总被引:1,自引:0,他引:1  
A program of sampling for volatile organic compounds (VOCs) in ambient air was undertaken in selected locations and micro-environments in Perth, Western Australia to characterise concentrations of target VOCs and to determine the relative strength of the contributing sources to ambient air in different micro-environments in a major Australian city. Twenty-seven locations were sampled and, of the forty-one target compounds, 26 VOCs were detected in the samples collected. The highest concentrations were recorded for benzene, toluene, ethylbenzene, xylenes (BTEX), chloroform and styrene. The maximum 12-h toluene and benzene concentrations observed were from a basement carpark and were 24.7 parts per billion (ppb) and 5.6 ppb, respectively. The maximum xylenes concentration was 29.4 ppb and occurred in a nightclub where styrene was also detected. A factor analysis of the data was undertaken. Two key factors emerge that appear to be associated with petroleum and motor vehicles and environmental tobacco smoke. A third significant occurrence was a high concentration of chloroform that was observed at a sports centre complex with a swimming pool text and was uncorrelated with other compounds in the data set. This study indicates that locations associated with motor vehicles and petrol fuel, tobacco and wood smoke and chlorinated water represent the major risks for personal exposure to VOCs in Perth.  相似文献   

19.
ABSTRACT

This study reports on the occupational inhalation exposure to VOCs of workers in the Kuwaiti printing industry. Using the evacuated canister methodology, we targeted 72 VOCs in three printeries and compared the concentrations to previous reports and relevant occupational exposure levels (OELs). We found that recent efforts in the printing industry to reduce VOC usage had been successful, as concentrations of key hazardous VOCs were substantially lower than anticipated. On the other hand, nearly all target VOCs were found. Non-production areas were sampled along with the offset printing areas, another strength of this study, and revealed exposures to hazardous VOCs among administers and digital printer and CTP operators. Exposure to ototoxic VOCs amounted to 1–3% of the OEL, consisting mostly of ethylbenzene, which was likely in use in two of the study printeries. Exposure to carcinogenic or probably carcinogenic VOCs was 15–20% of the OEL at four locations across the three printeries, consisting mostly of vinyl chloride and benzyl chloride. Vinyl chloride VOC was partially sourced from outdoors, but was also likely used inside the study printeries. Interestingly, concentrations of vinyl chloride were similar in most sampling locations to that of CFC-114, a CFC banned by the Montreal Protocol and not commonly used as a refrigerant. This unexpected finding suggests further study is warranted to identify the use of these VOCs in printeries. Exposure to hazardous VOCs up to nearly 50% of the OEL, consisting largely of bromoform and vinyl chloride. Bromoform was found in all the study printeries, sourced partially from outdoor air. The higher concentrations found inside the study printeries likely resulted from the use of the desalinated water for washing. This finding raises of emissions from sources other than blanket washes, and inks, etc. adding to the total VOC load in printery indoor air.

Implications: Results from this study indicate that efforts to reduce worker exposure to VOCs particularly dangerous to human health in recent years have been successful, but there is still much to be done to protect workers. Exposures to ototoxic and carcinogenic VOCs were identified, among both production and non-production workers. Unexpected findings included the apparent use in printing activities of the carcinogen vinyl chloride and CFC-114, banned under the Montreal Protocol. Observed lapses in safety procedures included failure to utilize ventilation systems and closing doors between work areas, indicating management and worker education should remain a priority.  相似文献   

20.
During the months of October to November, many important festivals are celebrated in India. Celebration of these festivals are marked by extensive use of fireworks or pyrotechnics, bonfire, incense burning, open air community cooking, and temporary eateries using crude fuel such as coal, wood, kerosene, cow dung, burning of raw/semiwood, and coconut shells. The present study deals with the influence of these unregulated anthropogenic activities on ambient mixing level of volatile organic compounds (VOCs), especially some carbonyl compounds. The study was undertaken in the metropolitan city of Kolkata, India, with very high population density, which is even higher during festival period. The average total carbonyl level at different sites in Kolkata varied from 134.8 to 516.5 μg m?3 in pre-festival season, whereas in post-festival season the same varied from 252.2 to 589.3 μg m?3. Formaldehyde to acetaldehyde ratio altered from 0.62 in pre-festival season to 1.78 in post-festival season. Diurnal variation also altered, indicating variation in source composition of carbonyls. The total ozone forming potential calculated for all 14 carbonyls in pre-festival season increased by 35% in post-festival season. The effect of anthropogenic activities typical to the event of Diwali night characterized by intense execution of pyrotechnics resulted in significantly high level of carbonyl VOCs. Principal component analysis study for the event of Diwali shows clear contribution of the event on certain carbonyl VOCs. The results indicate elevated primary emissions of these pollutants and also their effect on formation of secondary pollutants. The study emphasizes the need of generating awareness among the communities in society as well as need for regulations to minimize the emissions and related hazards to the extent possible.

Implications: Altered anthropogenic activities typical of festival season including extensive use of pyrotechnics affect ambient level of volatile organic compounds, especially some carbonyls. Such activities have considerable effect on interspecies ratio and diurnal variation. They also affect formation of secondary pollutants such as tropospheric ozone. Principal component analysis (PCA) study shows clear contribution of the pyrotechnics execution on certain carbonyl VOCs. The findings emphasize the need of generating awareness in society and need for regulations to minimize the emissions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号