首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
In order to assess the urban runoff control effectiveness of a low-impact development best management practice (LID-BMP) treatment train system, a field test of selected LID-BMPs was conducted in China. The LID-BMPs selected include three grassed swales, a buffer strip, a bioretention cell, two infiltration pits, and a constructed wetland. The test site is in a campus in southern China. The LID-BMPs, connected in a series, received stormwater runoff from four tennis courts with an area of 2808 m2 and eight basketball courts with an area of 4864 m2. Construction of the LID-BMPs was completed in early spring of 2012, and the sampling was conducted during May of 2012 to September of 2013. During the sampling effort, besides the performance evaluations of grassed swales and the bioretention cell in controlling runoff quantity as well as quality, the emphasis was also on determining the performance of the LID-BMP treatment train system. A total of 19 storm events were monitored, with nine producing no runoff and ten producing runoff. Data collected from the ten storm events were analyzed for estimating runoff quantity (peak flow rate and total runoff volume) and quality reduction by the LID-BMPs. The sum of loads (SOL) method was used for calculating the water quality performance of LID-BMPs. Results indicated that, for peak flow rate, a bioretention cell reduction of 50–84 % was obtained, and grassed swale reduction was 17–79 %, with a runoff volume reduction of 47–80 and 9–74 %, respectively. For water quality, the bioretention cell in general showed good removal for zinc (nearly 100 %), copper (69 %), NH3-N (ammonia nitrogen) (51 %), and total nitrogen (TN) (49 %); fair removal for chemical oxygen demand (COD) (18 %); and poor removal for total suspended solids (TSS) (?11 %) and total phosphorus (TP) (?21 %). And its performance effectiveness for pollutant removal increased in the second year after 1 year of stabilizing. When considering the aggregated effect of the LID-BMP treatment train system, it showed excellent removal for NH3-N (73 %), TN (74 %), and TP (95 %) and fair removal for COD (19 %) and TSS (35 %). The assessment results of the LID-BMP treatment train system provide valuable information on how to link the different types of LID-BMP facilities and maximize the integrated effectiveness on urban runoff control.  相似文献   

2.
北京市主要水污染物排放特征及水质改善对策   总被引:3,自引:1,他引:2  
污染排放信息是环境决策的重要依据。分析了北京市水环境质量的现状,基于最新源排放清单,解析北京市当前主控污染物COD、氨氮排放的结构特征和空间特征,以期为北京市开展基于流域综合治理的水污染控制和水环境管理提供依据。按照工业源、农业源、生活源和集中处理设施的环境统计口径,2013年,COD、氨氮的排放构成分别为2.7%、37.1%、35.0%、25.3%和1.5%、20.1%、54.8%、23.6%。其中,农业源中畜禽养殖排放是主要来源,COD、氨氮总排放分别占农业源总排放量的94.7%和87.0%。在北京市五大水系中,北运河流域排放量最大,COD、氨氮排放量分别占全市总排放量的53.3%和57.4%。为改善北京市水环境质量,建议从加快污水处理厂提标改造、推动面源污染治理、加强水利联通、合理规划城市规模布局等4个方面入手。  相似文献   

3.
Composite samples of septage discharging at the Khirbit As-Samra municipal wastewater treatment plant were analyzed during the period from February to the end of October 2007. Septage showed difference in concentrations of pollutants between summer and winter. The average total chemical oxygen demand (COD) of 6,425 mg/L during summer was 2.16 times greater than that in winter, which is 2,969 mg/L. The total biochemical oxygen demand (5 d) represented 45% of total COD in both winter and summer. Anaerobic biodegradability was 75% after 81 d of digestion at 35°C with a biodegradation rate constant (k) of 0.024 d???1, which was lower compared with 0.103 d???1 calculated for wastewater with domestic origin in Jordan. Aerobic biodegradability for septage was 48%??COD basis??after 7 d of digestion at 35°C. The lower anaerobic biodegradation rate of septage compared with that of raw wastewater of domestic origin suggested that septage could have a negative effect on the performance of a domestic wastewater treatment plant if septage discharges are not taken into account in the original design of the treatment plant.  相似文献   

4.
This study assesses the efficiency of various physico-chemical, biological and other tertiary methods for treating leachate. An evaluation study on the treatability of the leachate from methane phase bed (MPB) reactor indicated that at an optimum hydraulic retention time of 6 days, the efficiency of the reactor in terms of biological oxygen demand (BOD) and chemical oxygen demand (COD) removal was 91.29 and 82.69%, respectively. Recycling of the treated leachate through the municipal solid waste layers in the leachate recycling unit (LRU) resulted in a significant increase in the biodegradation of organics present in the leachate. Optimum BOD and COD removal efficiencies were achieved at the third recycle; additional recycling of the leachate did not produce any significant improvement. Physico-chemical treatment of the leachate demonstrated that alum and lime (Option 2) were more economical than coagulants lime and MgCO3. A cost analysis of the economics of the various treatments revealed that the alternative treatment consisting of a MPB bed followed by a LRU and aerated lagoon is the most cost-effective treatment. However, the alternative consisting of a MPB followed by the LRU and a soil column, which is slightly more costly, would be the most appropriate treatment when adequate land is readily available.  相似文献   

5.
This study investigates the quality of stormwater runoff from a driveway in the southwest mountainous urban area of Chongqing, China, from 2010 to 2011. The results showed that the mean concentrations of chemical oxygen demand (COD), total nitrogen (TN), and total phosphorus (TP) were 4.1, 2.4, and 2.2 times the grade V levels of the national surface water standard of China. The pollutant concentration peak preceded or synchronized with the rainfall intensity peak and occurred 10 min after the runoff started. The significant high pollutant concentration in the initial stage of the rainfall suggested that first flush control is necessary, especially for the most polluted constitutes, such as total suspended solids, COD, and TN. Three potential pollution sources were identified: the atmospheric dry and wet deposition (TN, NO3 ?-N, NH4 +-N, and DCu), the road sediment and materials (total suspended solids, COD, and TP), and the vehicle emissions (DPb and DZn). Therefore, this study indicates that reductions in road sediments and material pollution and dry and wet deposition should be the priority factors for pollution control of road stormwater runoff in mountainous urban areas.  相似文献   

6.
A 5-day biochemical oxygen demand (BOD(5)) test has been used as the standard measurement of organic pollution in rivers worldwide. However, it may be argued that BOD is not a sufficient indicator of organic pollution when nitrogenous biochemical oxygen demand (NBOD) is present in water samples. In this study, BOD, NBOD, and carbonaceous biochemical oxygen demand (CBOD) of treated sewage effluent (TSE) were measured near at the discharge outlet of 3 sewage treatment plants (STPs) in Sakai, Itachi, and Kashio rivers in Central Japan. Additional measurements were conducted at one point upstream and two points downstream from the STP discharge points in the rivers. It was estimated that NBOD values in the TSE of Sakai River, Kashio River and Itachi River accounted for 54%, 69% and 18% of their BOD values, respectively. Respective NH4+ and NO2- concentrations were positively correlated with those of NBOD values in Sakai, Itachi, and Kashio rivers. The BOD loads from the TSE were estimated to be 2.2, 5.7, and 1.2 times higher than the CBOD loads in the Sakai, Itachi, and Kashio rivers, respectively. The variation of the portion of NBOD values of each TSE, as well as the ratios of CBOD to BOD loads, was attributed to the difference in each STP system. Consequently, the NH4+ and NO2- of TSE led to the increase of NBOD in the Sakai River basin.  相似文献   

7.
The objective of the study was to treat eutrophic river water using floating beds and to identify ideal plant species for design of floating beds. Four parallel pilot-scale units were established and vegetated with Canna indica (U1), Accords calamus (U2), Cyperus alternifolius (U3), and Vetiveria zizanioides (U4), respectively, to treat eutrophic river water. The floating bed was made of polyethylene foam, and plants were vegetated on it. Results suggest that the floating bed is a viable alternative for treating eutrophic river water, especially for inhibiting algae growth. When the influent chemical oxygen demand (COD) varied from 6.53 to 18.45 mg/L, total nitrogen (TN) from 6.82 to 12.25 mg/L, total phosphorus (TP) from 0.65 to 1.64 mg/L, and Chla from 6.22 to 66.46 g/m3, the removal of COD, TN, TP, and Chla was 15.3 %–38.4 %, 25.4 %–48.4 %, 16.1 %–42.1 %, and 29.9 %–88.1 %, respectively. Ranked by removal performance, U1 was best, followed by U2, U3, and U4. In the floating bed, more than 60 % TN and TP were removed by sedimentation; plant uptake was quantitatively of low importance with an average removal of 20.2 % of TN and 29.4 % of TP removed. The loss of TN (TP) was of the least importance. Compared with the other three, U1 exhibited better dissolved oxygen (DO) gradient distributions, higher DO levels, higher hydraulic efficiency, and a higher percentage of nutrient removal attributable to plant uptake; in addition, plant development and the volume of nutrient storage in the C. indica tissues outperformed the other three species. C. indica thus could be selected when designing floating beds for the Three Gorges Reservoir region of P. R. China.  相似文献   

8.
Antibiotics consumption has increased worldwide, and their residues are frequently reported in aquatic environments. It is believed that antibiotics reach aquatic water bodies through sewage. Medicine consumed for healthcare practices are often released into sewage, and after sewage treatment plant, it reaches the receiving water bodies of lakes or rivers. In the present study, we determined the fate of some commonly used antibiotics in a sewage treatment plant (STP) located in Delhi and the environmental concentration of these antibiotics in the Yamuna River, which receives the sewage and industrial effluent of Delhi. There are many reports on antibiotics occurrences in STP and river water worldwide, but monitoring data from the Indian subcontinent is sparse. Samples were taken from a STP and from six sampling sites on the Yamuna River. Several antibiotics were tested for using offline solid-phase extraction followed by high-performance liquid chromatography equipped with photodiode array analysis. Recoveries varied from 25.5–108.8 %. Ampicillin had the maximum concentration in wastewater influents (104.2?±?98.11 μg l?1) and effluents (12.68?±?8.38 μg l?1). The fluoroquinolones and cephalosporins had the lower concentrations. Treatment efficiencies varied between 55 and 99 %. Significant amounts of antibiotics were discharged in effluents and were detected in the receiving water body. The concentration of antibiotics in the Yamuna River varied from not detected to 13.75 μg l?1 (ampicillin) for the compounds investigated.  相似文献   

9.
Surface water quality is vulnerable to pollution due to human activities. The upper reach of the Hun River is an important water source that supplies 52 % of the storage capacity of the Dahuofang Reservoir, the largest reservoir for drinking water in Northeast China, which is suffering from various human-induced changes in land use, including deforestation, reclamation/farming, urbanization and mine exploitation. To investigate the impacts of land use types on surface water quality across an anthropogenic disturbance gradient at a local scale, 11 physicochemical parameters (pH, dissolved oxygen [DO], turbidity, oxygen redox potential, conductivity, biochemical oxygen demand [BOD5], chemical oxygen demand [COD], total nitrogen [TN], total phosphorus [TP], NO 3 ? -N, and NH 4 + -N) of water from 12 sampling sites along the upper reach of the Hun River were monitored monthly during 2009–2010. The sampling sites were classified into four groups (natural, near-natural, more disturbed, and seriously disturbed). The water quality exhibited distinct spatial and temporal characteristics; conductivity, TN, and NO 3 ? -N were identified as key parameters indicating the water quality variance. The forest and farmland cover types played significant roles in determining the surface water quality during the low-flow, high-flow, and mean-flow periods based on the results of a stepwise linear regression. These results may provide incentive for the local government to consider sustainable land use practices for water conservation.  相似文献   

10.
The Bothnian Bay, which is the northernmost part of the Gulf of Bothnia in Northern Finland, is affected by effluents discharged from point sources such as the pulp and paper mills of Stora Enso Oyj Veitsiluoto Mill and Oy Metsä-Botnia Ab Kemi Mill at Kemi, and the Kemi municipal sewage plant, as well as the River Kemijoki. In this paper we discuss, how modernisation of the wastewater treatment plant at the mills, and process investments in the Best Available Techniques (BAT) for effluent treatment, have decreased the effluent discharges of biological oxygen demand (BOD), chemical oxygen demand (COD), total phosphorus (Tot-P), total nitrogen (TOT-N), total suspended solids (TSS) and adsorbable organically bound halogens (AOX) from the mills since 1988. One specific aim of the study was to determine the EOX (Extractable Organically Bound Halogens) concentrations in bottom sediment of the Bothnian Bay in order to assess whether the EOX concentrations reflect the reduction in discharges of chlorinated compounds. According to the monitoring program carried out every third year between 1997–2006, the decreasing trend in EOX concentrations in the top 2 cm of the bottom sediment reflect the decrease in organochlorine discharges (AOX) from the mills. In 1997 the EOX concentrations in bottom sediment varied between 3–70 μg of Cl g?1 (dry weight), and in 2006 between 3.3–32 μg of Cl g?1 (dry weight).  相似文献   

11.
依据污染源调查资料,采用距离法对克孜勒苏河喀什市段污染物的入河量进行估算。结果表明:污水处理厂排放口是克孜勒苏河喀什市段最主要的污染源,COD、NH3-N、TN、TP的排放量占研究区域总量的61%~83%;其次是豆腐厂总排口,4项指标占研究区域总排放量的17%~37%,也是该河段的主要污染源。两者各指标排放量之和均超过区域总量的98%。不同类型的污染源中,生活源COD、NH3-N、TN、TP的贡献率分别是工业源的2、5、4和1.6倍。  相似文献   

12.
When a domestic wastewater treatment plant (DWWTP) is put into operation, variations of the wastewater quantity and quality must be predicted using mathematical models to assist in operating the wastewater treatment plant such that the treated effluent will be controlled and meet discharge standards. In this study, three types of gray model (GM) including GM (1, N), GM (1, 1), and rolling GM (1, 1) were used to predict the effluent biochemical oxygen demand (BOD), chemical oxygen demand (COD), and suspended solids (SS) from the DWWTP of conventional activated sludge process. The predicted results were compared with those obtained using backpropagation neural network (BPNN). The simulation results indicated that the minimum mean absolute percentage errors of 43.79%, 16.21%, and 30.11% for BOD, COD, and SS could be achieved. The fitness was higher when using BPNN for prediction of BOD (34.77%), but it required a large quantity of data for constructing model. Contrarily, GM only required a small amount of data (at least four data) and the prediction results were analogous to those of BPNN, even lower than that of BPNN when predicting COD (16.21%) and SS (30.11%). According to the prediction, results suggested that GM could predict the domestic effluent variation when its effluent data were insufficient.  相似文献   

13.
Environmental monitoring of leachate quality from an open municipal solid waste dumping site in Tunceli, Turkey was studied in this research. The most commonly examined pollution parameters were determined on a seasonal basis. The annual average 5-day biological oxygen demand (BOD5) and chemical oxygen demand (COD) values of station points were measured as 70 and 425 mg/L, respectively, and also the average BOD5/COD ratio (a measure of biodegradability) was calculated as 0.20. The low ratio of biodegradability and slightly alkaline pH values in the leachate samples indicated that the site was characterized by methanogenic conditions. The mean ammonium-nitrogen (NH4 +-N) and corresponding phosphate (orthophosphate) values were assayed as 70 and 11 mg/L, respectively. The average solids content in the leachates was measured as 4,681 mg/L (total solids) and 144 mg/L (suspended solids). Very low concentrations of iron, manganese, copper, and zinc in the leachate samples were found and the concentration of cadmium was measured below detection limits. Excessive amount of nutrients and high organic and inorganic pollutant content in the leachates pose serious pollution potential to the environment. Since no drainage system or bio treatment exists in this open dumping site, high permeability of natural soil at the site and in the surrounding area and very fractured and crackled rocks under natural soil are indicators of high groundwater pollution potential in this site.  相似文献   

14.
Treated effluents become one of the most significant sources for irrigation and other activities in arid and semi arid countries such as Oman. This study focuses on characterizing the quality of domestic wastewater in chosen three regions: Muscat, Sohar, and Salalah. The knowledge on treatment processes, quality, and proper management of domestic wastewater reuse for various purposes is essential. Wastewater samples were collected from six different sewage treatment plants (STPs) over a period of 1 year in 2009 on a monthly basis. The raw sewage (RS) and treated effluent (TEs) samples were collected from different sampling points in each STP. Both types of samples were analyzed for physicochemical and microbiological assessment. All tests were conducted according to the standard method for the examination of water and wastewater. The results revealed that the TEs electrical conductivity, biological oxygen demand, chemical oxygen demand, heavy metals, sodium, potassium, and total dissolved solids values were found within Omani Standards (OS). The RS in all STPs was categorized as high strength concentration and samples exceeded the acceptable range for ammonia in most of the selected plants except Sohar and Salalah. Nitrate values in RS were also observed in higher concentrations. In general, the produced TEs have met most of regulatory limits stated by OS except for nitrate, Escherichia coli and total suspended solids (TSS). Furthermore, it should be noted that the performance of Salalah and Darsayt STPs can be classified as the best compared to the other four STPs studied in Oman.  相似文献   

15.
We investigated conventional characterization of wastewaters of the "Kullar Domestic Wastewater Treatment Plant." In the study of conventional characterization; 23 composite samples, which were taken during 10 months, were used and analysed as COD, BOD5, TKN, NH3-N, SS, VSS, TP, RP, TS, Alkalinity, oil and grease, detergent, chloride parameters. For determine of the plant efficiency, 8 output grab samples were taken. The COD and BOD5 values of influent, respectively, ranging from 37 to 1,056 mg/L and 8 to 140 mg/L in total wastewater. The meanly BOD5/COD ratio was calculated as 0.34 in total wastewaters.  相似文献   

16.
Urban wastewater in Turkey is primarily discharged without treatment to marine environments, streams and rivers, and natural and artificial lakes. Since it has been well established that untreated effluent in multi-use waters can have acute and chronic impacts to both the environment and human health, it is important to evaluate the consequences of organic enrichment relative to the structure and function of aquatic environment. We investigated the impacts of untreated municipal wastewater discharge from the city of Gumushane in the Eastern Black Sea Region of Turkey on the surface water quality of the stream Harsit. Several key water-quality indicators were measured: chemical oxygen demand (COD), ammonium nitrogen (NH 4 + –N), nitrite nitrogen (NO 2 ? –N), nitrate nitrogen (NO 3 ? –N), total Kjeldahl nitrogen (TKN), total nitrogen (TN), orthophosphate phosphorus (PO 4 3? –P), methylene blue active substances (MBAS), water temperature (t), pH, dissolved oxygen (DO), and electrical conductivity (EC). The monitoring and sampling studies were conducted every 15 days from March 2009 to February 2010 at three longitudinally distributed stations. While t, pH, DO, and EC demonstrated relatively little variability over the course of the study, other parameters showed substantial temporal and spatial variations. The most dramatic differences were noted in COD, NH 4 + –N, NO 2 ? –N, TKN, TN, PO 4 3— P, and MBAS immediately downstream of the wastewater discharge. Concentration increases of 309 and 418 % for COD, 5,635 and 2,162 % for NH 4 + –N, 2,225 and 674 % for NO 2 ? –N, 283 and 478 % for TKN, 208 and 213 % for PO 4 3? –P, and 535 and 1,260 % for MBAS were observed in the summer and autumn, respectively. These changes were associated with greatly diminished seasonal stream flows. Based on NO 2 ? –N, TKN, PO 4 3— P, and MBAS concentrations, it was concluded that Harsit stream water was correctly classified as polluted. The most telling parameter, however, was NH 4 + –N, which indicated highly polluted waters in both the summer and autumn. The elevated concentrations of both P and N in the downstream segment of the stream triggered aggressive growth of submerged algae. This eutrophication of river systems is highly representative of many urban corridors and is symptomatic of ongoing organic enrichment that must be addressed through improved water treatment facilities.  相似文献   

17.
In this study, the variation of sewage quality was investigated and the active fraction of different microbial functional groups in biofilm was quantified in a 5.6-km trunk sewer line. The sewage quality including suspended solids, biochemical oxygen demand, total chemical oxygen demand (COD), total nitrogen, total Kjeldahl nitrogen, ammonia nitrogen, nitrite nitrogen, and nitrate nitrogen were measured and compared with the values in literatures. The results indicated that since the wastewater treatment plant was not operated at its full capacity, the concentrations of different compounds were lower compared with the values in literatures. The values of heterotrophic growth rate constant lay between 5.6 and 8.6 day???1. Its average value was 7.7 day???1. The values of heterotrophic lysis rate constant lay between 0.2 and 0.4 day???1. The active heterotrophic biomass in biofilm varied from 240 to 800 mg COD m???2 and average value was 497 mg COD m???2. The biofilm mass varied from 880 to 1,080 mg m???2. The percentage of heterotroph to biofilm mass fall within the range of 24.0–90.9% and average value was 52.9%. In the oxygen uptake rate batch tests, the biomass, growth rate constant, and lysis rate constant of autotroph could not be determined because the fraction of autotroph in biofilm was relatively few. It revealed that the degradation of organic matters, nitrification, and denitrification occurred in the trunk sewer line. But the results indicate that the condition seem favorable for nitrification.  相似文献   

18.
The paper presents new studies about the removal efficiencies and characterization of the Municipal Wastewater Treatment Plant (MWWTP) in Kayseri, Turkey, which is serving for 800,000 population equivalents with the capacity of 110,000 m(3)/day, between 2006 and 2009. Kayseri discharges its effluents to Karasu Creek that downstream joins the Kizilirmak river, the longest river in Turkey discharging into the Black Sea. Four years of operation data between 2006 and 2009 calendar years were obtained from KASKI General Directorate. Influent and effluent samples were collected daily and suspended solids (SS), chemical oxygen demand (COD), biochemical oxygen demand in 5 days (BOD(5)), total nitrogen (TN), and total phosphorus (TP) were measured, aiming to study the evolution of the removal efficiencies for each year. The following yearly mean removal efficiencies were performed in the treatment plant: 94%, 97%, 97%, 95% for SS; 94%, 96%, 95%, 95% for COD; 98%, 98%, 98%, 98% for BOD(5); 84%, 87%, 89%, 82% for TN; and 71%, 86%, 80%, 86% for TP, in 2006, 2007, 2008, and 2009, respectively. The performance of Kayseri MWWTP was given both in terms of influent and effluent quality and in comparison with the current legislation on discharge limits to the receiving body. During the studied period, mean concentrations in the effluent did not exceed the imposed limits, but sometimes, higher values were noticed for SS, TN, and TP. In conclusion, the plant performances concerning these parameters were excellent and Kayseri MWWTP was operating efficiently according to the conventional control parameters.  相似文献   

19.
Physical, chemical and microbiological efficiencies of Sewage Treatment Plants (STPs) located in Delhi's watershed in context of different treatment technologies employed in these plants have been determined. There were in all seventeen STPs treating domestic wastewater which were studied over a period of 12 months. These STPs were based on Conventional Activated sludge process (ASP), Extended aeration (Ex. Aeration), physical, chemical and biological removal treatment (BIOFORE) and oxidation pond treatment process. Results suggests that except "Mehrauli" STP which was based on Extended aeration process and "Oxidation pond", effluents from all other STPs exceeded FC standard of 10(3) MPN/100 ml for unrestricted irrigation criteria set by National river conservation directorate (NRCD). Actual integrated efficiency (IE(a)) of each STP was evaluated and compared with the standard integrated efficiency (IE(s)) based upon physical, biological and microbiological removal efficiencies depending upon influent sewage characteristics. The best results were obtained for STPs employing extended aeration, BIOFORE and oxidation pond treatment process thus can be safely used for irrigation purposes.  相似文献   

20.
The biologically treated distillery effluent (BTDE) contains intense colour, high total dissolved solids (TDS), chemical oxygen demand (COD) and biochemical oxygen demand (BOD). These properties even after primary, secondary and tertiary treatments contain high concentrations of TDS, COD and BOD. The paper highlights the safe disposal and treatment of BTDE on land through High Rate Transpiration System (HRTS). HRTS is a zero discharge, low cost, high-tech method for improving the quality of BTDE for potential reuse. The experiments conducted at bench and pilot scale showed that HRTS having coconut husk as a bedding material could successfully treat the BTDE with a hydraulic load of 200 m3 ha−1 day−1 having BOD of 100 mg l−1 and 500 m3 ha−1 day−1 having BOD of 500 mg l−1 with average COD load of 0.686 and 2.88 ton ha−1 day−1 during the post and pre monsoon periods respectively. There was no significant increase in the organic carbon of the soil irrigated with BTDE. The concentrations of various pollutants analyzed in the leachate were within the prescribed limit for the drinking water sources. The colour removal was 99 to 100% and BOD and COD were possible to treat with optimum hydraulic loading of BTDE through HRTS planted with Dendrocalamus strictus.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号