首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 328 毫秒
1.
Royal Commission Environmental Control Department (RC-ECD) at Yanbu industrial city in Kingdom of Saudi Arabia has established a well-defined monitoring program to control the pollution from industrial effluents. The quality of effluent from each facility is monitored round the clock. Different strategic measures have been taken by the RC-ECD to implement the zero discharge policy of RC. Industries are required to pre-treat the effluent to conform pretreatment standards before discharging to central biological treatment plant. Industries are not allowed to discharge any treated or untreated effluent in open channels. After treatment, reclaimed water must have to comply with direct discharge standards before discharge to the sea. Data of industrial wastewater collected from five major industries and central industrial wastewater treatment plant (IWTP) is summarized in this report. During 5-year period, 3,705 samples were collected and analyzed for 43,436 parameters. There were 1,377 violations from pretreatment standards from all the industries. Overall violation percentage was 3.17%. Maximum violations were recorded from one of the petrochemical plants. The results show no significant pollution due to heavy metals. Almost all heavy metals were within RC pretreatment standards. High COD and TOC indicates that major pollution was due to hydrocarbons. Typical compounds identified by GC-MS were branched alkanes, branched alkenes, aliphatic ketones, substituted thiophenes, substituted phenols, aromatics and aromatic alcohols. Quality of treated water was also in compliance with RC direct discharge standards. In order to achieve the zero discharge goal, further studies and measures are in progress.  相似文献   

2.
通过对典型行业废水有机污染物排放现状的调查研究,探讨我国现有污水排放标准存在的问题,即现有的标准不能有效控制废水特征有机污染物排放。依据美国环保局多介质环境模型,用不同方法计算水介质排放环境目标值,用该值作为标准限值,评价典型行业废水有机污染物监测结果。针对典型行业废水有机污染物排放特征,提出制订排放控制标准的建议。  相似文献   

3.
生物监测可以系统反映污染物对生物生长的影响及其在生物体内的转化和迁移,在水环境监测与生态健康管理中的重要性日益突出。伴随着工业化的快速发展,中国水环境污染问题依然严峻,工业废水治理和排放问题仍旧突出。为进一步保障工业废水出水及受纳水体水质安全,迫切需要在工业废水监测中引入生物监测技术。对传统微生物群落监测法、水生生物毒性监测法和基于分子生物学技术的微生群落监测法等在工业废水监测领域的研究及应用进行了综述,并对存在的问题进行了总结。建议后续进一步完善工业废水生物监测体系时,参考国外成熟经验,制定出符合国内需求及特征的工业废水生物监测方法与评价标准,以便更好地掌握工业区整体环境健康及污染状况。  相似文献   

4.
造纸行业是废水污染物减排重点行业。以2011—2014年全国环境统计调查数据为基础,对不同规模造纸企业废水治理运行费用和绩效进行了分析,对COD、氨氮排放强度及减排潜力进行了对比。结果表明,不同规模企业污染治理与排放特征存在差异,大中型企业产排污强度低,废水治理投入大;若造纸行业企业全部达标排放,COD排放量在2014年水平上减排21.4%~47.2%,氨氮排放量降低27.7%。  相似文献   

5.
选择典型造纸厂,采用化学激活报告基因法(CALUX)测定造纸过程中废水和纸浆中的二噁英类物质,并将部分样品测定结果与高分辨气相色谱-高分辨质谱(HRGC-HRMS)法测定结果作线性回归,换算系数为0.21,表明CALUX可用于造纸行业废水中二噁英类物质的快速筛查。将CALUX用于测定造纸厂废水中二噁英类物质,结果表明用含元素氯的漂白工艺会产生大量二噁英类物质,其中漂白废水中的目标物毒性当量浓度最高,经处理后可达到国家排放标准;而用无元素氯的漂白工艺,二噁英类物质的产生量会大幅降低。  相似文献   

6.
苏北农村主要水体氮磷污染及防治   总被引:2,自引:0,他引:2  
由于大量使用化肥及排放各类污水已造成苏经农村主要水体搂磷严重污染,并具有氮素富营养型及水文期变化特征。防治污染的方法是采用一些针对性措施对污染严重水域进行直接治理;加强监测,掌握污染动态,推广测土配方的施肥技术;加强对各类污水的治理。  相似文献   

7.
Wastewater reuse can significantly reduce environmental pollution and save the water sources. The study selected Cheng-Ching Lake water treatment plant in southern Taiwan to discuss the feasibility of wastewater recycling and treatment efficiency of wastewater treatment units. The treatment units of this plant include wastewater basin, sedimentation basin, sludge thickener and sludge dewatering facility. In this study, the treatment efficiency of SS and turbidity were 48.35–99.68% and 24.15–99.36%, respectively, showing the significant removal efficiency of the wastewater process. However, the removal efficiencies of NH3–N, total organic carbon (TOC) and chemical oxygen demand (COD) are limited by wastewater treatment processes. Because NH3–N, TOC and COD of the mixing supernatant and raw water are regulated raw water quality standards, supernatant reuse is feasible and workable during wastewater processes at this plant. Overall, analytical results indicated that supernatant reuse is feasible.  相似文献   

8.
The temporal variability of phosphorus (P) transport and the relationships between discharge, suspended sediment concentration and particulate (PP), and soluble (SP) phosphorus were examined. The study was conducted at the event scale in seven tributaries of the Zarivar Lake watershed in Kurdistan Province (Iran) from March 2011 to April 2012. Based on eight runoff events, 82% of the total P was the PP carried out by suspended sediment. Results showed a high variability of P transport during different runoff events. It was found that soil erosion was the source of the high P load. For all tributaries, PP was linearly related to both discharge and suspended sediment concentration. However, the relationships of SP and PP with discharge and suspended sediment concentration showed different hysteresis patterns. The relationship between PP and discharge was generally characterized by a clockwise pattern (i.e., lower part contribution of the sub-watersheds) but the patterns between SP and discharge were mainly anticlockwise (i.e., upper part contribution of the sub-watersheds or perhaps due to a subsurface flow contribution).  相似文献   

9.
In this study, baseflow and storm discharges were monitored in seven watersheds of varying development density to document the effects of development on stream water quality. In addition, two of the watersheds contained package wastewater treatment facilities, which were evaluated as an alternative to residential on-site septic systems. Monthly grab samples of baseflow and flow-proportional samples of storm event discharge were collected and analyzed for nitrogen, phosphorus, sediment, and bacteria. For the five watersheds without wastewater treatment facilities, a significant linear relationship was documented between fecal coliform and enterococci levels in baseflow samples and the percentage of residential or impervious area. For the two watersheds with wastewater discharge, bacteria levels were significantly greater than those from the two relatively undeveloped watersheds. These results indicate that bacteria levels increased with increasing residential development even if many of the septic systems were replaced by a community wastewater treatment system. Computed annual export rates for ammonia nitrogen (NH3-N) were correlated to the percentage of impervious surfaces in the watersheds, while the rates for other nitrogen forms, total phosphorus, and total suspended sediment were not. Annual export rates from the two mostly undeveloped watersheds were greater than a compilation of rates for undeveloped areas across the USA. Export from the four watersheds with more than 68 % residential land use was less than those reported from local and national studies of residential areas.  相似文献   

10.
Environmental assessments are often performed for industries due to a lot of issues produced in the processes. However, few studies are reported for environmental assessment of Chinese liquor production. A lot of material consumptions in Chinese liquor industries often bring about serious environmental pollution. Thus, Chinese strong aromatic liquor (CSAL) is taken as a representative for the environmental issues assessment of Chinese liquor industry in view of cleaner production (CP). The assessment is performed for the brewing system of CSAL including three main phases: crude liquor brewing, crude liquor blending, and steam production, which addresses resource and energy consumptions and environmental impacts. The results indicate that, according to the standards of Ministry of Environmental Protection of China, the consumptions of materials and energy are acceptable while the water consumption is higher than the requirement. Moreover, the discharge of chemical oxygen demand (COD) in the brewing phase is above the standard requirement and contributes much to eutrophication. The total environmental impacts in the blending phase are less than those in the brewing and steam production phases. In detail, in the brewing phase, high concentration of volatile organic compounds in the wastewater results in the odor threshold values and photochemical ozone creation. In the blending phase, the main environmental impact is eutrophication owing to the wastewater. In the steam production phase, the most and least significant impacts are global warming and soot emission, respectively, wherein waste gas emission is dominated. Cost analysis reveals that when the water consumption and COD discharge meet the requirements according to the CP option, there are plenty of economic and environmental benefits for the CSAL industry. The results confirm that the reform strategies for the Chinese liquor enterprise should be performed to decrease the water consumption, promote the utilization efficiency of water, improve recycle and reuse of by-products, reduce the pollutant discharge, and enhance waste treatment efficiency.  相似文献   

11.
采用多元线性回归-分光光度法进行电镀排放废水中Cr3+、Ni2+、Zn2+的同时测定研究。以4-(2-吡啶偶氮)间苯二酚(PAR)为显色剂,探索了同时测定模拟电镀废水中Cr3+、Ni2+、Zn2+的实验方法,建立多元线性回归模型。根据实际电镀排放废水中Cr3+、Ni2+、Zn2+的质量浓度分布调查结果,设计了测定较低和较高浓度范围2种模型,分别对应不同水质波动程度的电镀企业废水,前者浓度范围设置基本覆盖大多数实际电镀排放废水中Cr3+、Ni2+、Zn2+的浓度,且具有较高精度。测定浓度范围较小模型对应水质波动较小的电镀排放废水,模型中Cr3+、Ni2+、Zn2+的质量浓度分别为0.32~0.44、0.32~0.50、0.72~0.84 mg/L,平均相对误差MR...  相似文献   

12.
New environmental standards for protecting aquatic organisms for zinc (e.g., 0.03 mg/L) in surface waters were set in Japan in 2003. Although wastewater effluent might be one of the major pathways of zinc to public water bodies in Japan, current status of concentration of zinc in wastewater effluent was not clear due to higher detection limits (e.g., 0.5 mg/L) than the level required by the new regulations. This study aims at assessing current status of zinc in wastewater effluent in Japan to revise wastewater effluent standards for protecting aquatic organisms. Survey of zinc in wastewater treatment plants (WWTPs) was carried out in Japan in 2005, setting the detection limits at least 0.01 mg/L. The results of the survey suggested the difficulty to remove zinc (especially dissolved zinc) with conventional activated sludge treatment if concentration of zinc in influent was relatively low. And it was suggested that high concentration of dissolved zinc might be derived from some industries discharging high concentration of zinc. The concentration of zinc in wastewater influent without industrial discharges was about 0.1 mg/L which might be lower than that in wastewater from industries discharging high concentration of zinc. Finally, effluent standards for point sources including WWTPs to public water bodies were set at 2 mg/L in 2006. Based on the results of the survey that it was difficult to remove dissolved zinc discharged from industries at WWTPs, the effluent standards from industries to sewerage were set at the same value of the effluent standards from WWTPs to public water bodies.  相似文献   

13.
南京市污水处理厂污泥处理处置现状   总被引:1,自引:0,他引:1  
调查了南京市污水处理厂污泥产生量、成分、达标状况以及污泥处置方式,指出了污泥处置中存在的问题。提出依据国家相应的标准和法律法规,建立和完善污泥处理处置产业政策,大力发展相关技术和工艺等建议。  相似文献   

14.
Water crisis is one of the most serious problems faced by the world today. Phytoremediation is one of the serious efforts towards sustainability. Macrophyte-based wastewater treatment systems have several potential advantages compared with conventional treatment systems. Duckweeds (Lemna spp., Spirodela spp., Wolffia spp.) are small, green freshwater, free-floating aquatic plants. The primary objective of this work was to analyze the role of duckweeds in organic waste and nutrient removal from domestic wastewater being generated from hostels of Birla Institute of Technology, Mesra, Ranchi (India). Interesting results were obtained in which the BOD value reduced by 94.45% and the level of orthophosphate at the end of the work was found to be reduced by 79.39%. The duckweeds flourished well during the experimental period in the pH range of 7 to 8; it can be said that, other factors remaining favorable, the optimum pH for duckweed growth ranges from 7 to 8. Therefore, it can be concluded that this treatment can be successfully carried out on a large scale. Also, it is a low-cost solution to wastewater treatment problems and could satisfy the discharge standards.  相似文献   

15.
为了准确评估厌氧-缺氧-好氧(A2/O)处理工艺对废水毒性的削减效率,采用斑马鱼胚胎急性毒性实验、发光细菌急性毒性实验和小鼠L929细胞毒性实验进行测试,结合理化指标,通过毒性当量(TU)法、平均毒性(AvTx)法、毒性指数(TxPr)法、最敏感测试(MST)法和潜在生态毒性效应(PEEP)法对常州市6家污水处理厂(生活污水、综合废水、化工废水、制药废水)进水和出水的生物毒性进行了评价。结果表明,斑马鱼胚胎的毒性敏感程度最高,3种受试生物的毒性评价结果具有较好的一致性。理化达标的污水处理厂出水仍存在一定的生物毒性效应,出水毒性较大的是综合污水处理厂,排入受纳水体后可能会对周围的生态环境产生潜在的生态风险。A2/O处理工艺对各污水处理厂进水的毒性削减较好,其中对制药废水的毒性削减最高,AvTx、TxPr、MST和PEEP的毒性削减率分别为99.45%、99.64%、99.48%和69.66%。与AvTx、TxPr、MST法相比,PEEP法能够更综合地评价废水毒性。  相似文献   

16.
Industrial wastewater typically contains various metal ions. Traditional metal ion treatment processes such as chemical precipitation generate large volumes of toxic sludge which needs to be further solidified or disposed of. The ferrite process (FP), which is another effective approach of treating metal ion-containing wastewater, can crystallize metal ions into ferrites; the sludge easily precipitates, is stable and can be recycling. This investigation explores the feasibility of the Fenton process and the FP (FFP) for treating wastewater that contains metal ions. It considers one factor that adds noise to the FP, ethylenediaminetetraacetic acid, and establishes the optimum parameters of each procedure. The analytical results demonstrate that the proper conditions for Fenton process were pH = 2, [Fe(2+)] = 10(-2) M, H(2)O(2) dosing rate = 5 x 10(-4) mol min(-1), reaction time = 12 min. For the proposed multi-stage FP, the preferred Fe(2+) dosage was 0.098 mol in each stage and the sludge met the toxicity characteristic leaching procedure standards. Following the FFP, the effluent water or the sludge easily met Taiwan's standards. Finally, the SEM test demonstrated that size of the sludge particles was 50-110 nm.  相似文献   

17.
中国农村饮用水水源地水质状况研究   总被引:2,自引:1,他引:1  
为了系统评估中国农村饮用水水源地水质变化情况,根据2009—2018年农村饮用水水源地水质监测数据,综合评价和分析了中国农村地表和地下饮用水达标情况、空间分布和主要超标因子等。监测结果表明:10年来,农村饮用水水源地达标率不断提高,这主要得益于地表饮用水水质整体改善;地下饮用水水质达标率持续偏低,且略有变差趋势,与城市地区的差距逐年加大。农村饮用水水源地超标断面和点位在空间上分布较广,主要超标因子相对集中,且表现出与农村和农业面源污染较强的相关性。建议进一步重视农村饮用水水源地(特别是地下饮用水)的保护,加强农村饮用水水源地水质监测,加快农业面源污染防治。  相似文献   

18.
When a domestic wastewater treatment plant (DWWTP) is put into operation, variations of the wastewater quantity and quality must be predicted using mathematical models to assist in operating the wastewater treatment plant such that the treated effluent will be controlled and meet discharge standards. In this study, three types of gray model (GM) including GM (1, N), GM (1, 1), and rolling GM (1, 1) were used to predict the effluent biochemical oxygen demand (BOD), chemical oxygen demand (COD), and suspended solids (SS) from the DWWTP of conventional activated sludge process. The predicted results were compared with those obtained using backpropagation neural network (BPNN). The simulation results indicated that the minimum mean absolute percentage errors of 43.79%, 16.21%, and 30.11% for BOD, COD, and SS could be achieved. The fitness was higher when using BPNN for prediction of BOD (34.77%), but it required a large quantity of data for constructing model. Contrarily, GM only required a small amount of data (at least four data) and the prediction results were analogous to those of BPNN, even lower than that of BPNN when predicting COD (16.21%) and SS (30.11%). According to the prediction, results suggested that GM could predict the domestic effluent variation when its effluent data were insufficient.  相似文献   

19.
With its total drainage basin of 37 107 km2 and mean annual discharge of 307 m3 s-1, the River Kymi is one of the largest in Finland. Presently it receives treated domestic wastewaters of about 160 000 inhabitants through eight treatment plants and treated industrial effluents from four paper mills, two cardboard mills and one pulp mill. In the 1960s all the wastewaters were discharged untreated to the river. However, the construction of domestic wastewater treatment plants began in the 1970s and mechanical wastewater treatment became common in industry. By the end of the 1980s practically all the wastewaters discharged to the river were treated in activated sludge processes. The aim of this paper was to investigate the influence of wastewater purification on the bacteriological quality of the river during these three decades. The bacteriological quality of the river was evaluated on the basis of annual medians of fecal streptococci (FS) calculated for 15 sites on the basis of 4804 FS enumerations from the years 1964-1992. The results show that the bacteriological quality improved steadily as the number of treatment plants increased and wastewater treatment became more effective. In the beginning of the 1960s the annual FS medians in the central part of the river were typically 1000-1500 CFU/100 ml, whereas in the 1990s they had decreased to 30-40 CFU/100 ml (CFU = colony forming units). The results indicate that FS input to the river was mainly of domestic origin.  相似文献   

20.
花垣河锰污染及其成因分析   总被引:4,自引:1,他引:3       下载免费PDF全文
对花垣河河水中8个监测断面(S1-S8)水样和堆积在河岸附近MnSO4废渣及其浸出液中Mn、Cd、Pb、Cu和Zn等5种重金属元素的总量进行了分析。结果表明,花垣河河水中Mn和Cd质量浓度超过《地表水环境质量标准》(GB3838—2002)V类水体标准;MnSO4废渣浸出液中Cd超过《危险废物鉴别标准》(GB5058.3—1996)规定值。将花垣河河水中Mn、Cd、Pb、Cu和Zn的含量与MnSO4废渣浸出液中相应的元素含量进行相关性分析,r=0.957(P〈0.01),表明堆积在花垣河河岸附近MnSO4废渣是可能造成花垣河污染的主要来源。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号