首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The need to determine occupational exposure to bioaerosols has notably increased in the past decade, especially for microbiology-related workplaces and laboratories. Recently, two new cyclone-based personal bioaerosol samplers were developed by the National Institute for Occupational Safety and Health (NIOSH) in the USA and the Research Center for Toxicology and Hygienic Regulation of Biopreparations (RCT & HRB) in Russia to monitor bioaerosol exposure in the workplace. Here, a series of wind tunnel experiments were carried out to evaluate the physical sampling performance of these two samplers in moving air conditions, which could provide information for personal biological monitoring in a moving air environment. The experiments were conducted in a small wind tunnel facility using three wind speeds (0.5, 1.0 and 2.0 m s(-1)) and three sampling orientations (0°, 90°, and 180°) with respect to the wind direction. Monodispersed particles ranging from 0.5 to 10 μm were employed as the test aerosols. The evaluation of the physical sampling performance was focused on the aspiration efficiency and capture efficiency of the two samplers. The test results showed that the orientation-averaged aspiration efficiencies of the two samplers closely agreed with the American Conference of Governmental Industrial Hygienists (ACGIH) inhalable convention within the particle sizes used in the evaluation tests, and the effect of the wind speed on the aspiration efficiency was found negligible. The capture efficiencies of these two samplers ranged from 70% to 80%. These data offer important information on the insight into the physical sampling characteristics of the two test samplers.  相似文献   

2.
Exposure to persistent organic pollutants (POPs) and related compounds such as PCBs, brominated flame retardants, organochlorine pesticides and PAHs is regarded as an important environmental risk factor for humans. Recently concerns about POPs resulted in the international protocol called the Stockholm Convention on POPs. Air quality standards (indoor, outdoor and occupational) for PAHs and other POPs will also be applied in the EU in the future. This will bring requirements for monitoring, to check for compliance and to reduce human exposures to POPs. This can occur from point sources and in various microenvironments, indoors, outdoors and in workplaces. Monitoring can be undertaken either by an active (pumped) method or using a passive (diffusive) air sampling (PAS) device. To date, PAS for POPs have mainly been used as integrating (long-term) samplers for ambient (outdoor) air. However, there are several reasons to develop PAS for monitoring of POPs in occupational and indoor environments. We discuss the potential advantages, limitations and developments needed, so that PAS can be used reliably and routinely indoors and in occupational settings for POPs.  相似文献   

3.
The ability to sample in situ natural environmental processes has proven to be challenging when working with redox-sensitive contaminates in saturated sediments in wetland systems, especially within the rhizosphere, where sharp redox gradients are common. Many traditional approaches are invasive and disturb natural sediment chemistry. Through laboratory and field studies, the work presented in this study demonstrates a novel semipermanent dialysis sampler that allows for long-term, anaerobic monitoring of shallow sediments. Dialysis samplers were deployed and tested for over 1 year while being exposed to extremes in climate. These newly designed devices produce statistically reproducible data and capture sensitive redox trends. Results from the newly designed samplers were compared to conventional samplers. Initially, both the new and old designs yielded statistically similar data, but these data diverged over a period of months. The new devices are less invasive, so data gathered from these devices are more likely to be a closer representation of true conditions in the subsurface. By giving reliable data from a consistent location in space, these new samplers represent a significant step forward in capturing spatial and temporal variability in wetland redox chemistry during long-term monitoring.  相似文献   

4.
This paper reviews the framework that underpins the development of a new generation of personal samplers capable of operating at much lower flowrates that those of the current generation and so capable of being used for exposure assessment not only for 'traditional' occupational populations (i.e., industrial workers) but also for people exposed to aerosols in the ambient atmosphere (including children). The opportunity for this new generation of samplers stems from the availability of very light and compact low-flowrate pumps. The development and deployment of such instruments presents: (a) physical challenges in terms of how to collect particle size fractions in a manner which is consistent with the new particle size-selective sampling criteria, and (b) analytical challenges in terms of how to quantitate the much smaller amounts of collected material that need to be analysed. The paper lays out the physical and analytical scenarios, and points the way forward to how such challenges can be overcome. Work is already in progress in several countries to develop prototype instruments for applications like those described.  相似文献   

5.
A number of methods are used to assess exposure to high-molecular weight allergens. In the occupational setting, airborne dust is often collected on filters using pumps, the filters are eluted and allergen content in the eluate analysed using immunoassays. Collecting inhalable dust using person-carried pumps may be considered the gold standard. Other allergen sampling methods are available. Recently, a method that collects nasally inhaled dust on adhesive surfaces within nasal samplers has been developed. Allergen content can be analysed in eluates using sensitive enzyme immunoassays, or allergen-bearing particles can be immunostained using antibodies, and studied under the microscope. Settling airborne dust can be collected in petri dishes, a cheap and simple method that has been utilised in large-scale exposure studies. Collection of reservoir dust from surfaces using vacuum cleaners with a dust collector is commonly used to measure pet or mite allergens in homes. The sampling methods differ in properties and relevance to personal allergen exposure. Since methods for all steps from sampling to analysis differ between laboratories, determining occupational exposure limits for protein allergens is today unfeasible. A general standardisation of methods is needed.  相似文献   

6.
Tube type samplers with two different adsorbents, Chromosorb 106 and Tenax TA, were evaluated by laboratory experiments and field tests for simultaneous diffusive sampling of alpha-pinene, beta-pinene and delta 3-carene and subsequent thermal desorption-gas chromatographic analysis. No statistically significant effects of exposure time, concentrations of monoterpenes or relative humidity were found for samplers with Chromosorb 106 when running a factorial design, with the exception of the adsorption of delta 3-carene, for which some weak effects were noted. Samplers with Tenax TA were affected by the sampling time as well as the concentration for all terpenes, with a strong interaction effect between these two factors. The terpenes showed good storage stability on both adsorbents. No effect of back-diffusion was noted when using Chromosorb 106, while Tenax TA showed some back-diffusion effects. The uptake rates, in ml min-1, for the terpenes on Chromosorb 106 were 0.36 for alpha-pinene, 0.36 for beta-pinene and 0.40 for delta 3-carene. The corresponding average values on Tenax TA were 0.30 for alpha-pinene, 0.32 for beta-pinene and 0.38 for delta 3-carene. The field validation proved that diffusive sampling on Chromosorb 106 agreed well with pumped sampling on charcoal for stationary samples, while the personal samples indicated a discrepancy of 25% between Chromosorb 106 and charcoal samples. Tenax TA generally gave lower results than Chromosorb 106 in all field samples. Samplers packed with Chromosorb 106 could be used to monitor terpene levels in workplaces such as sawmills. The major advantages with this method are the sampling procedure, which is simple to perform compared to other techniques, the easily automated analysis procedure and the possibility to reuse the samplers.  相似文献   

7.
While air sampling techniques using adsorbent-based collection, thermal desorption and chromatographic analysis have found a niche in ambient air sampling, occupational applications have been more limited. This paper evaluates the use of thermal desorption techniques for low flow active and passive sampling configurations which allow conveniently long duration sampling in occupational settings and other high concentration environments. The use of an orifice enables flows as low as 0.5 ml min(-1) and sampling periods up to several days without significant biases. A model is used to predict sampling rates of a passive sampler encompassing an orifice, a void space, glass wool, and the adsorbent. Laboratory and field tests conducted at a commercial offset printing facility, which contained a variety of volatile organic compounds (primarily aromatic but also a few chlorinated and terpene compounds at levels from 1 to 67,000 microg m(-3)), are used to evaluate the approach. Tenax GR and Carbosieve SIII, both singly and together, were employed as adsorbents. Side-by-side tests comparing high flow, low flow and passive samplers show excellent agreement and high linearity (r = 0.95) for concentrations spanning nearly five orders of magnitude. Active samplers were tested at flows as low as 0.5 ml min(-1), compared to typical flows up to 40 ml min(-1). Passive samplers demonstrated a linear range and agreement with predictions for adsorbate loadings from approximately 1 ng to nearly 10 microg. Using a chemical mass balance receptor model, concentrations in the facility were apportioned to solvents, inks and other indoor and outdoor sources. Overall, the use of low flow active and passive sampling approaches employing thermal desorption techniques provides good performance and tremendous flexibility that facilitates use in many applications, including workplace settings.  相似文献   

8.
An understanding of the scaling laws governing aerosol sampler performance leads to new options for testing aerosol samplers at small scale in a small laboratory wind tunnel. Two methods are described in this paper. The first involves an extension of what is referred to as the "conventional" approach, in which scaled aerosol sampler systems are tested in a small wind tunnel while exposed to relatively monodisperse aerosols. Such aerosols are collected by test and reference samplers respectively and assessed gravimetrically. The new studies were carried out for a modified, low flowrate version of the IOM personal inhalable aerosol sampler. It was shown that such experiments can be carried out with a very high level of repeatability, and this supported the general validity of the aerosol sampler scaling laws. The second method involves a novel testing system and protocol for evaluating the performances of aerosol samplers. Here, scaled aerosol samplers of interest are exposed to polydisperse aerosols, again in a small wind tunnel. In this instance, the sampled particles are counted and sized using a direct-reading aerodynamic particle sizer (the APS). A prototype automated aerosol sampler testing system based on this approach was built and evaluated in preliminary experiments to determine the performance of another modified version of the IOM personal inhalable aerosol sampler. The design of the new test system accounts for the complex fluid mechanical coupling that occurs near the sampler inlet involving the transition between the external flow outside the sampler and the internal airflow inside the sampler, leading in turn to uncontrolled particle losses. The problem was overcome by the insertion of porous plastic foam plugs. where the penetration characteristics are well understood, into the entries of both the test and the reference samplers. Preliminary experiments with this new system also supported the general validity of the aerosol sampler scaling laws. In addition, they demonstrated high potential that this approach may be applied in a standardised aerosol testing method and protocol.  相似文献   

9.
Passive sampling devices have been used since the 1970s to measure time-weighted average (TWA) or equilibrium concentrations of pollutants in various environmental matrices (e.g. air, soils and sediments and water). In recent years the popularity of using such samplers has increased and the technology in now well established for the measurement of atmospheric pollutants. This sector has a long experience of using passive samplers in the short- and long-term assessment of air quality in the local environment and on a global scale (e.g. within the United Nations Stockholm Convention on the trans-boundary movement of persistent organic pollutants (POPs) where large networks of samplers on a continental scale have been established). In comparison, the use of passive samplers for monitoring the aquatic environment has been slower to take off. There has, however, been a recent research drive to develop devices for measuring the wide range of pollutants that can be found in environmental waters (e.g. ground, surface, and marine). It is now being recognised that passive samplers can play a valuable role in monitoring water quality within a legislative framework such as the European Union's Water Framework Directive (WFD). The data from these devices can be used alongside the results obtained from conventional spot or bottle sampling to improve risk assessments and to inform decisions on undertaking potentially expensive remedial actions. Such monitoring techniques may have uses within the European Registration, Evaluation, Authorisation & restriction of CHemicals (REACH) Directive and the forthcoming European Marine Strategy Directive. It is expected that the aquatic monitoring sector will follow a transition similar to that which occurred in air monitoring where data obtained from passive samplers can use used within a legal framework. There has also been increased interest in extending the role of passive samplers to both the measurement of equilibrium concentrations and investigating the movement and release of the dissolved fraction of various pollutants in the pore water of sediments and soils.  相似文献   

10.
Continuous, intermittent and passive sampling of airborne VOCs   总被引:1,自引:0,他引:1  
Long sampling periods are often advantageous or required for measuring air quality and characterizing exposures. However, sampling periods exceeding 8 to 24 h using thermally desorbable adsorbent tube (TDT) samplers for the measurement of airborne volatile organic compounds (VOCs) face several challenges, including maintaining stable and low flow rates, and avoiding breakthrough of the adsorbent. These problems may be avoided using intermittent sampling; however, the literature contains few if any reports that have evaluated this technique in environmental, occupational or other applications. The purpose of this study is to evaluate continuous, intermittent and passive sampling methods using both laboratory and real-world tests. Laboratory tests compared continuous and intermittent (active) samplers in a controlled dynamic test gas generation system. Field tests used side-by-side active and passive samplers in an office, home workshop and four smokers' homes. All samples were analyzed for a wide range of VOCs by GC-MS. In most instances, intermittent sampling yielded better reproducibility (duplicate precision of 10 +/- 6%) than continuous low-flow sampling (18 +/- 5%), in part due to difficulty maintaining low flows. Concentrations obtained using intermittent sampling agreed with those for continuous sampling, with downward biases resulting primarily from errors in flow rate measurements. In the field, more VOC species were detected using active rather than passive sampling. Passive measurements were 12% lower than continuous measurements, a difference attributed to declining uptake rates at higher concentrations over the 3 to 4 d sampling period. Overall, most measurements obtained using the three sampling methods agreed within 20% for a wide range of concentrations (0.1 to 230 microg m(-3)). Both passive and intermittent sampling approaches are suitable for long sampling periods, but intermittent sampling provides greater flexibility with respect to sampling period, and permits the use of multi-bed adsorbents that can capture a wider range of VOCs.  相似文献   

11.
Mass concentrations of PM 10 and PM 2.5 are planned as new standards for the monitoring of ambient air quality in the European Union. Standard procedure is the removal of particles > 10 microns and > 2.5 microns aerodynamic diameter, respectively, by impaction in a preseparator. Different samplers work according to different principles of flow control. The influence of ambient temperature, pressure and relative humidity on different devices is calculated to estimate the comparability of various aerosol samplers. Therefore, the effects of these ambient factors on the volume flow as well as on the cut-off dp50 are investigated. In a second step, the influence of relative humidity on the flow control device is calculated. The results show that the cut-off shifts (up to 6.4%) for varying ambient conditions. Therefore, the influence on the impaction process should not be neglected and an 'ideal sampler' would measure temperature, pressure and relative humidity and adapt the volume flow to avoid a systematic error in the cut-off.  相似文献   

12.
The need for ambient gaseous ammonia (NH(3)) measurements has increased in the last decade as reactive NH(3) concentrations and deposition fluxes show little change even with tightening standards on nitrogen oxides (NO(x)) emissions. Currently, there are several networks developing methods for adding NH(3) measurements in the U.S. Gaseous NH(3) measurements will provide scientists and policymakers data which can be used to estimate ecosystem inputs, validate air quality models including trends and regional variability, and evaluate changes to the environment based on additional emission reduction requirements and estimates of critical nitrogen load exceedances. The passive samplers described in this paper were deployed in duplicate or triplicate and collocated with annular denuders or continuous instruments to determine their accuracy. The samplers assessed included the Adapted Low-Cost Passive High Absorption (ALPHA), Radiello(?), and Ogawa passive samplers. The median relative percent differences (MRPD) between the reference method and passive samplers for the ALPHA, Radiello(?) and Ogawa were -2.4%, -37% and -44%, respectively. The precision between duplicate samplers for the ALPHA and Ogawa samplers, was 7% and 6%, respectively. Triplicate Radiello(?) precision was assessed using the coefficient of variation (CV). The CV for the Radiello(?) samplers was 10%. This article discusses the statistical results from these studies.  相似文献   

13.
In 2002 the Comité Européen Normalisation (CEN) published its document Workplace atmospheres-assessment of performance of instruments for measurement of airborne particle concentrations (EN 13205) that describes a standard protocol by which to carry out the testing and validation of personal aerosol samplers of the type widely used for occupational aerosol exposure assessment. It emerged from more than a decade of discussion and a large body of research experience involving several laboratories. The protocol that is described, however, still poses significant technical and economic challenges, not least because it involves laborious-and hence costly-procedures in large, specialized wind tunnel facilities. More recent research has identified a number of areas by which the protocol may be improved and made more accessible to testing laboratories, including a set of validated aerosol sampler scaling laws, a better understanding of the reduced role of the bluff body of the wearer on sampler performance, and the availability of new options for rapid sampler testing methods. Taking these into account, a dummy new protocol is offered for discussion.  相似文献   

14.
The uptake characteristics of semipermeable membrane devices (SPMDs) and polar organic chemical integrative samplers (POCISs) were examined for mono, di and tributyltin, triphenyltin, pyrene, benzo[a]pyrene, 4-tert-butylphenol, 4-n-nonylphenol, PCBs 77 and 153, PBDE 47, lindane, triclosan and DDT. Exposure in a flow through system continued for 28 days with samplers removed every 7 days in order to study the relevant uptake kinetics. Uptake remained linear for POCISs with sampling rates (Rs) of up to 0.2 L d(-1). For SPMDs uptake varied from linear to approaching equilibrium with Rs values of up to 14 L d(-1). 7 out of 9 results for SPMDs could be explained by an empirical model (nonylphenol and lindane were exceptions). None of the four organo-tin compounds studied were detected in POCISs and only tributyltin was accumulated significantly by SPMDs. The establishment of these sampling rates allows the calculation of time weighted water concentrations for several important contaminants. Using presented methods, sampling rates and exposure conditions, theoretical detection limits for selected compounds by SPMDs were between 11-68 pg L(-1), which is well below the environment quality standard proposed for those compounds that are included in the European Water Framework Directive.  相似文献   

15.
Inhalable sampler efficiency depends on the aerodynamic size of the airborne particles to be sampled and the wind speed. The aim of this study was to compare the behaviour of three personal inhalable samplers for welding fumes generated by Manual Metal Arc (MMA) and Metal Active Gas (MAG) processes. The selected samplers were the ones available in Spain when the study began: IOM, PGP-GSP 3.5 (GSP) and Button. Sampling was carried out in a welding training center that provided a homogeneous workplace environment. The static sampling assembly used allowed the placement of 12 samplers and 2 cascade impactors simultaneously. 183 samples were collected throughout 2009 and 2010. The range of welding fumes' mass concentrations was from 2 mg m(-3) to 5 mg m(-3). The pooled variation coefficients for the three inhalable samplers were less than or equal to 3.0%. Welding particle size distribution was characterized by a bimodal log-normal distribution, with MMADs of 0.7 μm and 8.2 μm. For these welding aerosols, the Button and the GSP samplers showed a similar performance (P = 0.598). The mean mass concentration ratio was 1.00 ± 0.01. The IOM sampler showed a different performance (P < 0.001). The mean mass concentration ratios were 0.90 ± 0.01 for Button/IOM and 0.92 ± 0.02 for GSP/IOM. This information is useful to consider the measurements accomplished by the IOM, GSP or Button samplers together, in order to assess the exposure at workplaces over time or to study exposure levels in a specific industrial activity, as welding operations.  相似文献   

16.
Assessment of population exposure to VOC in ambient atmospheres is receiving heightened interest as the adverse health effects of chronic exposure to certain of these compounds are identified. Active (pumped) and passive samplers are the most commonly used devices for this type of monitoring. It has been shown, however, that these devices, along with all other preconcentration techniques, are susceptible to ozone interference. It is demonstrated that this interference occurs even at low ozone concentrations and that it may result in the under-estimation of population exposure. A convenient and effective ozone scrubbing method is identified and successfully applied and validated for both active and passive samplers for a range of VOC.  相似文献   

17.
Factors concerning NO2 uptake by the absorbent triethanolamine (TEA) in NO2 diffusion tubes are examined. Although the nominal freezing point of TEA is 17.9-21.2 degrees C, we show that, for a range of aqueous TEA solutions (0-20%, H2O), no freezing occurs even at -10 degrees C. Therefore NO2 collection efficiency is unlikely to be impaired by low temperature exposure. The recovery of TEA from the meshes of exposed samplers is determined as approximately 98%, even after 42 days, showing that the stability in situ of TEA is unaffected by long-term exposure. A model of a diffusion tube sampling array for simultaneous exposures, with a 0.1 m sampler spacing, shows that NO2 uptake by individual samplers is not affected by the presence of neighbouring tubes in the array. This is confirmed by sampler precision at two Cambridge sites. Four sampler preparation methods are compared for differences in NO2 uptake of exposed samplers. All methods employ TEA as absorbent, transferred by either dipping meshes in a TEA-acetone solution or pipetting aliquots of a TEA-H2O solution onto the meshes. For samplers prepared by three of the methods, no difference in NO2 uptake is found, but for samplers prepared using a 50% v/v TEA-H2O solution, a mean reduction of 18% is found. Student's t-tests show that the difference is highly significant (P < or = 0.001). Reasons for the difference are discussed.  相似文献   

18.
This study presents an evaluation of the extent of differences between measurements performed by O(3) and NO(2) diffusive samplers and by the reference methods for diffusive samplers commercially available. The tests were performed in an exposure chamber under extreme conditions of controlling factors and under field conditions. For NO(2), the results of the laboratory experiments showed that most of the diffusive samplers were affected by extreme exposure conditions. The agreement between the samplers and the reference method was better for the field tests than for the laboratory ones. The estimate of the uptake rate for the exposure conditions using a model equation improved the agreement between the diffusive samplers and the reference methods. The agreement between O(3) measured by the diffusive samplers and by the reference method was satisfactory for 1-week exposure. For 8-hour exposures, the diffusive samplers with high uptake rates quantified better the O(3) concentration than the samplers with low uptake rates. As for NO(2), the results of the O(3) field tests were in better agreement with the reference method than the ones of the laboratory tests. The field tests showed that the majority of diffusive samplers fulfils the 25% uncertainty requirement of the NO(2) European Directive and the 30% uncertainty requirement of the O(3) European Directive for 1-week exposure.  相似文献   

19.
Agricultural production systems are recognised as a major source of atmospheric ammonia. Deposition of ammonia and ammonium may contribute to undesired changes in oligotrophic ecosystems. The continuous measurement of atmospheric ammonia requires expensive and sophisticated techniques and is performed only in a very restrict number of ambient air stations in Europe. Therefore, the application of passive samplers, which have the advantage of being easy to handle and cost-efficient, is useful. In the past the comparability of different passive samplers must be considered as rather scarce. In a joint European project under the leadership of the GSF-Forschungszentrum für Umwelt und Gesundheit, Neuherberg, in 1997 a comparison of different passive ammonia monitoring methods was carried out in a prealpine rural site near Garmisch-Partenkirchen. It was considered valuable to include not only well established systems but also methods still being developed. For the comparative test ten working groups with different methods took part. A wet annular denuder system, which has been developed by the Netherlands Energy Research Foundation for on-line measurement of atmospheric ammonia, served as reference of passive methods. The experiment, which started in June and finished in December, showed that most of the passive samplers fulfil the requirements and can be recommended for further measurements. Additional measurements of meteorological parameters were performed to check the influences of different weather conditions on passive sampling.  相似文献   

20.
This paper concludes a five-year program on research into the use of a portable X-ray fluorescence (XRF) analyzer for analyzing lead in air sampling filters from different industrial environments, including mining, manufacturing and recycling. The results from four of these environments have already been reported. The results from two additional metal processes are presented here. At both of these sites, lead was a minor component of the total airborne metals and interferences from other elements were minimal. Nevertheless, only results from the three sites where lead was the most abundant metal were used in the overall calculation of method accuracy. The XRF analyzer was used to interrogate the filters, which were then subjected to acid digestion and analysis by inductively-coupled plasma optical-emission spectroscopy (ICP-OES). The filter samples were collected using different filter-holders or "samplers" where the size (diameter), depth and homogeneity of aerosol deposit varied from sampler to sampler. The aerosol collection efficiencies of the samplers were expected to differ, especially for larger particles. The distribution of particles once having entered the sampler was also expected to differ between samplers. Samplers were paired to allow the between-sampler variability to be addressed, and, in some cases, internal sampler wall deposits were evaluated and compared to the filter catch. It was found, rather surprisingly, that analysis of the filter deposits (by ICP-OES) of all the samplers gave equivalent results. It was also found that deposits on some of the sampler walls, which in some protocols are considered part of the sample, could be significant in comparison to the filter deposit. If it is concluded that wall-deposits should be analyzed, then XRF analysis of the filter can only give a minimum estimate of the concentration. Techniques for the statistical analysis of field data were also developed as part of this program and have been reported elsewhere. The results, based on data from the three workplaces where lead was the major element present in the samples, are summarized here. A limit of detection and a limit of quantitation are provided. Analysis of some samples using a second analyzer with a different X-ray source technology indicated reasonable agreement for some metals (but this was not evaluated for lead). Provided it is only necessary to analyze the filters, most personal samplers will provide acceptable results when used with portable XRF analysis for lead around applicable limit values.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号