首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 156 毫秒
1.
A total of 1094 water samples from 326 springs, 207 streams, 183 dug wells, 151 piped supplies, 90 tube wells, 75 hand pumps, 60 rivers and 2 lakes were collected from eight northern and six north-eastern districts of India. Samples were analysed to assess their potability by estimating the level of heavy metals and bacterial (coliform and faecal coliform) contaminations. Iron was found in a maximum number (53%) of water samples from hand pumps, followed by lead in 43% of the tube wells, chromium in 16% of dug wells, cadmium in 13% of streams and manganese in 7% of hand pumps above their maximum admissible concentrations (MACs). Maximum metal pollution has been observed in a considerable number of water samples from Doda, followed by Almora, Mirzapur and Bankura. Hand pump water samples exhibited maximum metal pollution followed by dug well, spring, stream and river water samples. Contamination of coliform and/or faecal coliform bacteria ranged between 41% and 67% of water samples from open water sources but it was also less, i.e. 6–15% of water samples from tube wells and hand pumps. In general, 42–85% of water samples from districts surveyed, except from Jammu (18%) and Mirzapur (27%), were found to be bacteriologically unsatisfactory. Since toxic metals and pathogenic bacteria pose a risk to public health, monitoring of drinking water sources is required.  相似文献   

2.
Faecal contamination is a major causative factor for incidence of water borne infectious diseases. Certain hydrogen sulfide (H2S) producing enteric bacteria such as Salmonella sp. and Citrobacter sp., assosiated with coliforms, have been considered for rapid detection of recent faecal contamination in water. The basic H2S test medium, modified by adding 0.25 gm/L of L-cystine HCl, was examined for its efficiency with 90 water samples collected from 40 pipe supplies, 20 open wells, 15 hand pumps and 15 different surface water bodies (river, streams and ponds). Sterilized modified culture medium in glass vials was inoculated with 100 mL of each sample and incubated at 20, 25, 30, 35 and 44 C for 18, 24, 42, 48, 66 and 72 h. Blackening of content in incubated vials was considered positive. For comparison, most probable number (MPN) of coliform and faecal coliform per 100 mL was also estimated in each sample by multiple tube fermentation (MTF) method. H2S positive result was exhibited by 78% of samples. Coliform (> 10) and faecal coliform/100 mL were also detected in 59% of samples. Maximum H2S positive results (100%) were found with well and surface water samples incubated at 30, 35 and 44 C for 18 h. Coliform (> 10) and faecal coliform/100 mL were also detected in most of these samples. Pipe supplies (60%) and hand pumps (73%) also exhibited considerable H2S production. Coliforms and faecal coliforms were also found in significant number of these samples. Thus, the modified H2S test may prove a useful alternative indicator of faecal contamination for water quality surveillance and screening of large number of water samples in short duration, particularly during any outbreak of water borne disease among rural population.  相似文献   

3.
Safe drinking water is scarce in southwest coastal Bangladesh because of unavailability of fresh water. Given the high salinity of both groundwater and surface water in this area, harvested rainwater and rain-fed pond water became the main sources of drinking water. Both the government and non-government organizations have recently introduced pipe water supply in the rural coastal areas to ensure safe drinking water. We assessed the bacteriological quality of water at different points along the piped water distribution system (i.e., the source, treatment plant, household taps, street hydrants, and household storage containers) of Mongla municipality under Mongla Upazila in Bagerhat district. Water samples were collected at 2-month interval from May 2014 to March 2015. Median E. coli and total coliform counts at source, treatment plant, household taps, street hydrants, and household storage containers were respectively 225, 4, 7, 7, and 15 cfu/100 ml and 42,000, 545, 5000, 6150, and 18,800 cfu/100 ml. Concentrations of both of the indicator bacteria reduced after treatment, although it did not satisfy the WHO drinking water standards. However, re-contamination in distribution systems and household storage containers indicate improper maintenance of distribution system and lack of personal hygiene.  相似文献   

4.
Efficient management of deteriorating water bodies can be achieved by determining the sources of faecal pollution. Resourceful techniques for discrimination of the sources of Escherichia coli in surface water have recently been developed, including the use of river water to facilitate faecal indicator surveillance, identification of sources of faecal contamination and employing relevant management practices to maintain water quality. This study was conducted to employ microbial source tracking (MST) techniques for the determination of the sources of faecal pollution based on a water quality investigation of the physico-chemical characteristics and coliform count point of the Tirumanimuttar River. To accomplish this, an MST library-based antibiotic resistance analysis, serotyping and the genomic tool rep-PCR techniques were applied, and the obtained results were analysed statistically. Among 135 and 70 E. coli isolates present in the library and water samples collected from the river and nearby well water sources, respectively, most showed intrinsic, high or moderate resistance to antibiotics. Isolates from human and pig faecal sources were 92% homologous with the samples from the river, whereas isolates from sewage and dairy cattle showed 89% and 80% homology, respectively. These findings indicated that the Tirumanimuttar River is subjected to stress from anthropogenic activities and runoff contaminated with agricultural and human faecal contamination. The sources of faecal pollution identified in this study may facilitate the monitoring and management of the Tirumanimuttar River.  相似文献   

5.
Drinking water quality assessment in Southern Sindh (Pakistan)   总被引:1,自引:0,他引:1  
The southern Sindh province of Pakistan adjoins the Arabian Sea coast where drinking water quality is deteriorating due to dumping of industrial and urban waste and use of agrochemicals and yet has limited fresh water resources. The study assessed the drinking water quality of canal, shallow pumps, dug wells, and water supply schemes from the administrative districts of Thatta, Badin, and Thar by measuring physical, chemical, and biological (total coliform) quality parameters. All four water bodies (dug wells, shallow pumps canal water, and water supply schemes) exceeded WHO MPL for turbidity (24%, 28%, 96%, 69%), coliform (96%, 77%, 92%, 81%), and electrical conductivity (100%, 99%, 44%, 63%), respectively. However, the turbidity was lower in underground water, i.e., 24% and 28% in dug wells and shallow pumps as compared to open water, i.e., 96% and 69% in canal and water supply schemes, respectively. In dug wells and shallow pumps, limits for TDS, alkalinity, hardness, and sodium exceeded, respectively, by 63% and 33%; 59% and 70%, 40% and 27%, and 78% and 26%. Sodium was major problem in dug wells and shallow pumps of district Thar and considerable percent in shallow pumps of Badin. Iron was major problem in all water bodies of district Badin ranging from 50% to 69% and to some extent in open waters of Thatta. Other parameters as pH, copper, manganese, zinc, and phosphorus were within standard permissible limits of World Health Organization. Some common diseases found in the study area were gastroenteritis, diarrhea and vomiting, kidney, and skin problems.  相似文献   

6.
Using the membrane filtration technique to count total coliform (TC), fecal coliform (FC) and fecal streptococci (FS), the microbiological water quality of the Mfoundi River and four of its representative tributaries at Yaoundé, Cameroon, was assessed for human use and contact. Sampling was conducted so as to examine the potential origin of fecal contamination and how rainfall affects the measured concentrations of indicators organisms. Our results revealed that waters were not safe for human use or primary contact according to the standards for water quality established by the Word Health Organization (WHO). Indeed, these waters exhibited high concentrations of TC (Mean ± SD=5.6 × 108 ± 2.5 × 106 CFU/100 ml), FC (Mean ± SD=6.8 × 105 ± 2.4 × 103 CFU/100 ml) and FS (Mean ± SD=7.3 × 105 ± 2.1 × 103 CFU/100 ml) that varied with the sampling sites and points. FC/FS ratio suggested that this contamination was more from warm-blooded animals than humans and correlation analysis points to the role of rainfall as a contributing factor, which enhanced the bacterial numbers detected. We conclude that there is a great potential risk of infection for users of waters from the Mfoundi River and its tributaries at Yaoundé.  相似文献   

7.
Impact of wastewater irrigation on some biological properties was studied in an area where treated sewage water is being supplied to the farmers since 1979 in the western part of National Capital Territory of New Delhi under Keshopur Effluent Irrigation Scheme. Three fields were selected which had been receiving irrigation through wastewater for last 20, 10 and 5 years. Two additional fields were selected in which the source of irrigation water was tubewell. The soil bacterial and fungal population density was studied in soil layers of 0?C15, 15?C30, 30?C60 and 60?C120 cm depths. Groundwater samples were collected from the piezometers installed in the field irrigated with sewage water for last 20, 10 and 5 years. Results indicate that there was significant increase in bacterial and fungal count in sewage-irrigated soils as compared to their respective control. The population density of bacteria and fungi in waste water-irrigated soils increased with the duration of sewage water application and decreased with increasing depth. The bacterial and fungal count was also directly proportional to organic carbon, sand and silt content and negatively correlated to the clay content, electrical conductivity, pH and bulk density of the soil. Groundwater under sewage-irrigated fields had higher values of most probable number (MPN) index as compared to that of tubewell water-irrigated fields. All the shallow and deep groundwaters were found to be contaminated with faecal coliforms. The vadose zone had filtered the faecal coliform to the tune of 98?C99%, as the MPN index was reduced from ??18,000 per 100 ml of applied waste water to 310 per 100 ml of groundwater under 20 years sewage-irrigated field. The corresponding values of MPN were 250 and 130 per 100 ml of shallow groundwater under 10 and 05 years sewage-irrigated fields, respectively. Rapid detection of faecal contamination suggested that the Citrobacter freundii and Salmonella were dominant in shallow groundwater, while Escherichia coli was dominant in deep groundwater collected from sewage-irrigated field.  相似文献   

8.
Faecal coliform (FC) levels in surface water and clams (Ruditapes decussatus) and variations in environmental parameters were studied in two bivalve harvesting areas in the Alvor lagoon (southern Portugal). Land use and cover characteristics in adjacent subwatersheds were also analysed to assess their contributions as sources of faecal contamination. High FC levels in clams from the harvesting area in the most urbanized subwatershed (impervious surface coverage ≈ 10.5%) were positively associated with rainfall and with the cooler periods of the year. FC levels in clams from the least urbanized subwatershed were generally very low and did not present any detectable seasonal trend. From these results, it was concluded that the periodic deterioration of the microbiological quality of clams derives from the cumulative impact of the reservoir of faecal contamination created in urbanized areas, entering into the lagoon during storm water runoff.  相似文献   

9.
The development of essential services including water and sanitation in many megacities of the economically developing countries of Asia cannot keep pace with their rapidly growing population and accompanying urban and industrial development. The inadequate water supply and poor sanitation services lead to contamination of their water supply. It also leads to the input of sewage water into the groundwater. The problem is seriously acute in Karachi, the largest city in Pakistan with a population of over 12 million and growing at 6 percent. This paper examines the problem of water contamination in Karachi. The paper presents the data on water quality from various sources, mainly municipal water supply, vendors and well water; the three major sources of water for domestic use in Karachi. Except municipal water from some areas and during certain periods, water from most other sources contain coliform bacteria, and in many cases faecal coliform, in amounts several magnitudes higher than any standards permit. Many samples have also been found to contain heavy metals including Chromium, Lead, Nickel and Arsenic in amounts excessive of permitted standards. The probable sources of contaminants for the various types of water (piped, vendors, wells) indicate that groundwater may be the main contributor. The very source of this groundwater is predominantly from sewage. The health hazards from consuming such contaminated water are obvious. The paper also evaluates the solutions that are being practiced, proposed or may be feasible, as well as those that are evolving.  相似文献   

10.
The present study was aimed to make an assessment of health risk due to pollution and human pathogenic bacteria associated with the recreational and drinking water sources in twin densely populated holy Indian cities Ayodhya and Faizabad. Though physicochemical studies revealed that the water available in the area is under recommended limits for human use, it is unsafe on account of poor microbiological quality of surface and ground water in the region. The most probable number (MPN) test results revealed the preponderance of ≥2,400 total coliforms (TC) (100 ml) − 1 in river, pond, dug well and kund waters. Contrary to that, 94% tube wells, 32% hand pumps and 25% piped supply water were under safe limits having <3 TC (100 ml) − 1. The shallow depth (~40 ft), water logging and presence of septic tanks in the near vicinity are the possible reasons of poor microbial quality of hand pump drinking water. The municipal supply water passes along sewage line where loose connections and/or cracks in pipe lead to mixing and contamination. The significant best quality of tube well water evident from the absence of TC could be attributed to the depth of well ≥150 ft and usually their location away from the habitation. A total of 263 bacteria from 186 water samples were isolated, and at least five genera of enteric bacteria from various water sources were identified morphologically and biochemically as Escherichia coli, Klebsiella sp., Enterobacter sp., Shigella sp. and Salmonella sp. The serotyping of 72 E. coli and 36 Salmonella sp. revealed 51 as E. coli O157 and 20 as Salmonella sp. The presence of enteric pathogens in water sources pose threat to human health and therefore call for immediate remedial measures.  相似文献   

11.
We assessed the incidence of faecal-indicator bacteria in Tyume River over a 12-month period between August 2010 and July 2011. Total coliforms, faecal coliforms and enterococci were determined by the membrane filtration method. Total coliforms were detected in counts ranging from 2.1?×?102 to 3.4?×?104?CFU/100 ml. Faecal coliform counts ranged from 1?×?102 to 1.6?×?104?CFU/100 ml while enterococci counts were in the range of 3.3?×?101 to 5.1?×?103?CFU/100 ml. Indicator bacteria counts increased from upstream to downstream sampling sites. Counts of indicator bacteria at all sites were significantly affected by seasonal changes. The bacteriological qualities of the river water were poor, exceeding the guideline of 200 CFU/100 ml and 33 CFU/100 ml for faecal coliforms and enterococci, respectively, for recreational water. Faecal coliform counts also exceeded the 1,000 CFU/100 ml guideline for water used in fresh produce irrigation. Microbial source tracking results showed that faecal pollution was predominantly of human origin during spring at all sampling sites. During other seasons, human faecal pollution was largely confined to midstream and downstream sampling sites. Generally, the presence of faecal-indicator bacteria in the river water samples suggests faecal pollution of this freshwater resource, raising the possibility of the presence of pathogenic microorganisms in the water and a threat to public health.  相似文献   

12.
Urban household kitchen environment was assessed for safety by determining their levels of indicator bacteria, hygienic habits and risk of cross-contamination. Household kitchens (60) were selected in Warri Town, Nigeria, by the multi-stage sampling technique. Contact surfaces, water and indoor kitchen air were analysed for aerobic plate counts, total and faecal coliforms using Nutrient and McConkey media by swab/rinse method, membrane filtration and sedimentation methods, respectively. Hygienic habits and risk of cross-contamination were assessed with structured questionnaire which included socio-demographic variables. On the basis of median counts, the prevalence of high counts (log cfu/cm2/m3/100 mL) of aerobic plate counts (>3.0), total coliforms (>1.0) and faecal coliforms (>0) on contact surfaces and air was high (58.0–92.0%), but low in water (30.0–40.0%). Pots, plates and cutleries were the contact surfaces with low counts. Prevalence of poor hygienic habits and high risk of cross-contamination was 38.6 and 67.5%, respectively. Education, occupation and kitchen type were associated with cross-contamination risk (P = 0.002–0.022), while only education was associated with hygienic habits (P = 0.03). Cross-contamination risk was related (P = 0.01–0.05) to aerobic plate counts (OR 2.30; CL 1.30–3.17), total coliforms (OR 5.63; CL 2.76–8.25) and faecal coliforms (OR 4.24; CL 2.87–6.24), while hygienic habit was not. It can be concluded that urban household kitchens in the Nigerian setting are vulnerable to pathogens likely to cause food-borne infections.  相似文献   

13.
The origin and distribution of microbial contamination in Lake Geneva's most polluted bay were assessed using faecal indicator bacteria (FIB). The lake is used as drinking water, for recreation and fishing. During 1 year, water samples were taken at 23 points in the bay and three contamination sources: a wastewater treatment plant (WWTP), a river and a storm water outlet. Analyses included Escherichia coli, enterococci (ENT), total coliforms (TC), and heterotrophic plate counts (HPC). E. coli input flux rates from the WWTP can reach 2.5 x 10(10) CFU/s; those from the river are one to three orders of magnitude lower. Different pathogenic Salmonella serotypes were identified in water from these sources. FIB levels in the bay are highly variable. Results demonstrate that (1) the WWTP outlet at 30 m depth impacts near-surface water quality during holomixis in winter; (2) when the lake is stratified, the effluent water is generally trapped below the thermocline; (3) during major floods, upwelling across the thermocline may occur; (4) the river permanently contributes to contamination, mainly near the river mouth and during floods, when the storm water outlet contributes additionally; (5) the lowest FIB levels in the near-surface water occur during low-flow periods in the bathing season.  相似文献   

14.
In 2010, a magnitude 7.0 earthquake struck Haiti, severely damaging the drinking and wastewater infrastructure and leaving millions homeless. Compounding this problem, the introduction of Vibrio cholerae resulted in a massive cholera outbreak that infected over 700,000 people and threatened the safety of Haiti’s drinking water. To mitigate this public health crisis, non-government organizations installed thousands of wells to provide communities with safe drinking water. However, despite increased access, Haiti currently lacks the monitoring capacity to assure the microbial safety of any of its water resources. For these reasons, this study was designed to assess the feasibility of using a simple, low-cost method to detect indicators of fecal contamination of drinking water that could be implemented at the community level. Water samples from 358 sources of drinking water in the Léogâne flood basin were screened with a commercially available hydrogen sulfide test and a standard membrane method for the enumeration of thermotolerant coliforms. When compared with the gold standard method, the hydrogen sulfide test had a sensitivity of 65 % and a specificity of 93 %. While the sensitivity of the assay increased at higher fecal coliform concentrations, it never exceeded 88 %, even with fecal coliform concentrations greater than 100 colony-forming units per 100 ml. While its simplicity makes the hydrogen sulfide test attractive for assessing water quality in low-resource settings, the low sensitivity raises concerns about its use as the sole indicator of the presence or absence of fecal coliforms in individual or community water sources.  相似文献   

15.
The prevalence and distribution of soil and water samples contaminated with enteroparasites of humans and animals with zoonotic potential (EHAZP) in Apucaraninha Indigenous Land (AIL), southern Brazil, was evaluated. An environmental survey was conducted to evaluate the presence of parasitic forms in peridomiciliary soil and associated variables. Soil samples were collected from 40/293 domiciles (10 domiciles per season), from November 2010 to June 2011, and evaluated by modified methods of Faust et al. and Lutz. Analyses of water from seven consumption sites were also performed. The overall prevalence of soil samples contaminated by EHAZP was 23.8 %. The most prevalent parasitic forms were cyst of Entamoeba spp. and eggs of Ascaris spp. The highest prevalence of contaminated soil samples was observed in winter (31 %). The probability map obtained with geostatistical analyses showed an average of 47 % soil contamination at a distance of approximately 140 m. The parasitological analysis of water did not detect Giardia spp. or Cryptosporidium spp. and showed that all collection points were within the standards of the Brazilian law. However, the microbiological analysis showed the presence of Escherichia coli in 6/7 sampled points. Despite the low level of contamination by EHAZP in peridomiciliar soil and the absence of pathogenic protozoa in water, the AIL soil and water (due to the presence of fecal coliforms) are potential sources of infection for the population, indicating the need for improvements in sanitation and water treatment, in addition periodic treatment of the population with antiparasitic.  相似文献   

16.
A one-year monitoring program was carried out to assess the degree of pollution in three creeks on the northern coast of the United Arab Emirates (UAE), through measuring for chemical nutrients such as phosphate, ammonium, nitrate, nitrite and dissolved oxygen, in addition to enumerating selected microbial communities such as the heterotrophic bacteria, salt tolerant heterotrophic bacteria, Gram-negative bacteria, total coliform and faecal coliform bacteria. The results indicated that Dubai and Sharjah creeks have occasional unusually high nutrients levels with sharp fluctuations and wide spatial and temporal variations, suggesting the presence of an anthropogenic sources of pollution, creating these conditions, near the sampling sites. These sources includes several wastewater outlets and recreational facilities. Ajman creek had much less nutrients levels. The microbial counts in the three creeks had a distinct pattern where numbers peaked in mid spring (May) and autumn (October) and were relatively low during the summer and winter months. Total and faecal coliform fluctuated depending on several factors including the presence of nearby recreation and commercial areas, but were at no time consistently high. It was concluded that there is no major pollution problem in these creeks and recommendation were made to prevent it in the future.  相似文献   

17.
A total of 16 people died and over 500 people were hospitalized due to diarrhoeal illness in the Bholakpur area of Hyderabad, India on 6th May 2009. A study was conducted with immediate effect to evaluate the quality of municipal tap water of the Bholakpur locality. The study consists of the determination of physico-chemical properties, trace metals, heavy metals, rare earth elements and microbiological quality of drinking water. The data showed the variation of the investigated parameters in samples as follows: pH 7.14 to 8.72, EC 455 to 769 μS/cm, TDS 303.51 to 515.23 ppm and DO 1.01 to 6.83 mg/L which are within WHO guidelines for drinking water quality. The water samples were analyzed for 27 elements (Li, Be, B, Na, Mg, Al, Si, K, Ca, V, Cr, Mn, Fe, Ni, Co, Cu, Zn, As, Se, Rb, Sr, Mo, Ag, Cd, Sb, Ba and Pb) using inductively coupled plasma-mass spectrometry (ICP-MS). The concentrations of Fe (0.12 to 1.13 mg/L), Pb (0.01 to 0.07 mg/L), Cu (0.01 to 0.19 mg/L), Ni (0.01 to 0.15 mg/L), Al (0.16 to 0.49 mg/L), and Na (38.36 to 68.69 mg/L) were obtained, which exceed the permissible limits of the World Health Organization (WHO) for drinking water quality guidelines. The remaining elements were within the permissible limits. The microbiological quality of water was tested using standard plate count, membrane filtration technique, thermotolerant coliform (TTC), and most probable number (MPN) methods. The total heterotrophic bacteria ranged from 1.0 × 105 to 18 × 10cfu/ml. Total viable bacteria in all the water samples were found to be too numerable to count and total number of coliform bacteria in all water samples were found to be of order of 1,100 to >2,400 MPN index/100 ml. TTC tested positive for coliform bacteria at 44.2°C. All the water samples of the study area exceeded the permissible counts of WHO and that (zero and minimal counts) of the control site (National Geophysical Research Institute) water samples. Excessively high colony numbers indicate that the water is highly contaminated with microorganisms and is hazardous for drinking purposes. Bacteriological pollution of drinking water supplies caused diarrhoeal illness in Bholakpur, which is due to the infiltration of contaminated water (sewage) through cross connection, leakage points, and back siphoning.  相似文献   

18.
Water quality monitoring is essential for the provision of safe drinking water. In this study, we compared a selection of fecal indicators with universal Bacteroidales genetic marker to identify fecal pollution of a variety of drinking water sources. A total of 60 samples were collected from water sources. The microbiological parameters included total coliforms, fecal coliforms, Escherichia coli and fecal streptococci as the fecal indicator bacteria (FIB), Clostridium perfringens and H2S bacteria as alternative indicators, universal Bacteroidales genetic marker as a promising alternative fecal indicator, and Salmonella spp., Shigella spp., and E. coli O157 as pathogenic bacteria. From 60 samples analyzed, Bacteroidales was the most frequently detected indicator followed by total coliforms. However, the Bacteroidales assay failed to detect the marker in nine samples positive for FIB and other alternative indicators. The results of our study showed that the absence of Bacteroidales is not necessarily an evidence of fecal and pathogenic bacteria absence and may be unable to ensure the safety of the water. Further research, however, is required for a better understanding of the use of a Bacteroidales genetic marker as an indicator in water quality monitoring programs.  相似文献   

19.
Anthropogenic activities associated with industrialization, agriculture and urbanization have led to the deterioration in water quality due to various contaminants. To assess the status of urban drinking water quality, samples were collected from the piped supplies as well as groundwater sources from different localities of residential, commercial and industrial areas of Lucknow City in a tropical zone of India during pre-monsoon for estimation of coliform and faecal coliform bacteria, organochlorine pesticides (OCPs) and heavy metals. Bacterial contamination was found to be more in the samples from commercial areas than residential and industrial areas. OCPs like α,γ-hexachlorocyclohexane and 1,1 p,p-DDE {dichloro-2, 2-bis(p-chlorophenyl) ethene)} were found to be present in most of the samples from study area. The total organochlorine pesticide levels were found to be within the European Union limit (0.5 μg/L) in most of the samples. Most of the heavy metals estimated in the samples were also found to be within the permissible limits as prescribed by World Health Organization for drinking water. Thus, these observations show that contamination of drinking water in urban areas may be mainly due to municipal, industrial and agricultural activities along with improper disposal of solid waste. This is an alarm to safety of public health and aquatic environment in tropics.  相似文献   