首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到10条相似文献,搜索用时 171 毫秒
1.
Febros river water was sampled weekly, during 35 successive weeks, and analyzed for microbiological (total coliforms, faecal coliforms, faecal streptococci and enterococci) and chemical-physical (ammonia and temperature) parameters. All microbiological parameters were highly correlated with each other and with ammonia, suggesting that the simultaneous determination of all variables currently in use in the evaluation of the microbiological quality of waters is probably redundant, and could be simplified, and that ammonia should be tested as a sentinel parameter of the microbiological pollution load of Febros river. From the strains isolated from positive tubes of the faecal coliforms test (multiple tube fermentation technique) and retested in this assay, Escherichia coli, Klebsiella oxytoca and Klebsiella pneumoniae subsp. pneumoniae strains were positive, indicating that the faecal coliforms test is not totally specific for Escherichia coli, and can detect other bacteria. Considering that these Klebsiella spp. are not necessarily of faecal origin, it was concluded that the faecal coliforms test can overestimate true faecal pollution. From the strains isolated from positive tubes of the faecal coliforms procedure, only Escherichia coli strains were clearly positive in the β-D-glucuronidase test. All other species were negative or very weakly positive, suggesting that the assay of the β-D-glucuronidase activity is less prone to false positives than the faecal coliforms test in the quantification of Escherichia coli in environmental waters.  相似文献   

2.
This study investigates the impact of wastewater treatment plant (WWTP) effluent on the toxicity of the recipient water body and the effectiveness of the disinfection treatment applied (sodium hypochloride) to assure the compliance of both microbiological and toxicological emission limits. No toxicity was found in the majority of samples collected from the recipient river, upstream and downstream of the WWTP, using three different toxicity tests (Vibrio fischeri, Daphnia magna, and Pseudokirchneriella subcapitata). Only three samples presented toxic unit (TU) values with V. fischeri, and one presented TU with P. subcapitata. The influent toxicity ranged from slightly toxic to toxic (TU = 0.68–4.47) with V. fischeri, while only three samples presented TU values with the other tests. No toxicity was found in the absence of chlorination, while the mean toxicity was 3.42 ± 4.12 TU with chlorination in the effluent. Although no toxicity or very slight toxicity was found in the receiving water, its residual toxicity was higher than the US EPA Quality Standard in two samples. Escherichia coli concentration had a lower mean value in the chlorinated effluent: 13,993 ± 12,037 CFU/100 mL vs. 62,857 ± 80,526 CFU/100 mL for the not chlorinated effluent. This difference was shown to be significant (p < 0.05). E. coli in ten chlorinated samples was higher than the limit established by European and Italian Legislation. The mean highest trihalomethanes (THMs) value was found in the influent samples (2.79 ± 1.40 μg/L), while the mean highest disinfection by-products (DBPs) was found in the effluent samples (1.85 ± 2.25 μg/L). Significant correlations were found between toxicity, sodium hypochlorite, THMs, DBPs, E. coli, and residual chlorine. In conclusion, this study highlighted that the disinfection of wastewater effluents with sodium hypochlorite determines the increase of the toxicity, and sometimes is not enough to control the E. coli contamination.  相似文献   

3.
We assessed the incidence of faecal-indicator bacteria in Tyume River over a 12-month period between August 2010 and July 2011. Total coliforms, faecal coliforms and enterococci were determined by the membrane filtration method. Total coliforms were detected in counts ranging from 2.1?×?102 to 3.4?×?104?CFU/100 ml. Faecal coliform counts ranged from 1?×?102 to 1.6?×?104?CFU/100 ml while enterococci counts were in the range of 3.3?×?101 to 5.1?×?103?CFU/100 ml. Indicator bacteria counts increased from upstream to downstream sampling sites. Counts of indicator bacteria at all sites were significantly affected by seasonal changes. The bacteriological qualities of the river water were poor, exceeding the guideline of 200 CFU/100 ml and 33 CFU/100 ml for faecal coliforms and enterococci, respectively, for recreational water. Faecal coliform counts also exceeded the 1,000 CFU/100 ml guideline for water used in fresh produce irrigation. Microbial source tracking results showed that faecal pollution was predominantly of human origin during spring at all sampling sites. During other seasons, human faecal pollution was largely confined to midstream and downstream sampling sites. Generally, the presence of faecal-indicator bacteria in the river water samples suggests faecal pollution of this freshwater resource, raising the possibility of the presence of pathogenic microorganisms in the water and a threat to public health.  相似文献   

4.
Simple microbial test comprising H2S paper strip test,presence-absence (PA) test, and fluorogenic brila broth (BB)test performed directly at 44.5 °C were evaluated andcompared with the standard most probable number (MPN) method fordetection of fecal coliforms in 173 drinking water sources. BBand PA test were comparable with standard MPN method, whereas,poor compliance was noted for H2S test. PA test whencompared with standard MPN test only 15%; disagreement wasdetected, whereas, highest disagreement of 40%; was observed incase of H2S test. BB test was found to be highly sensitiveas only 7.8% disagreement with that of standard MPN test wasfound. Three hundred cultures obtained from positive tests wereidentified in order to evaluate the specificities of test usedin detection of fecal indicator Escherichia coli. BB testwas also found highly specific in detection of indicatororganism as compared to PA and H2S test. Among theorganisms isolated from BB test 84.4%; of them were identifiedas E. coli as compared to 43.4 and 33.3 in PA and H2Stest, respectively. The low incidence of recovery of E.coli (18.1%) for the standard MPN method places doubt on thevalidity of its application in tropical areas. The result ofthis investigation suggest that BB performed directly at 44.5 °C could be suitable cost effective test to assess themicrobiological quality of drinking water in India and other tropical countries.  相似文献   

5.
Faecal contamination is a major causative factor for incidence of water borne infectious diseases. Certain hydrogen sulfide (H2S) producing enteric bacteria such as Salmonella sp. and Citrobacter sp., assosiated with coliforms, have been considered for rapid detection of recent faecal contamination in water. The basic H2S test medium, modified by adding 0.25 gm/L of L-cystine HCl, was examined for its efficiency with 90 water samples collected from 40 pipe supplies, 20 open wells, 15 hand pumps and 15 different surface water bodies (river, streams and ponds). Sterilized modified culture medium in glass vials was inoculated with 100 mL of each sample and incubated at 20, 25, 30, 35 and 44 C for 18, 24, 42, 48, 66 and 72 h. Blackening of content in incubated vials was considered positive. For comparison, most probable number (MPN) of coliform and faecal coliform per 100 mL was also estimated in each sample by multiple tube fermentation (MTF) method. H2S positive result was exhibited by 78% of samples. Coliform (> 10) and faecal coliform/100 mL were also detected in 59% of samples. Maximum H2S positive results (100%) were found with well and surface water samples incubated at 30, 35 and 44 C for 18 h. Coliform (> 10) and faecal coliform/100 mL were also detected in most of these samples. Pipe supplies (60%) and hand pumps (73%) also exhibited considerable H2S production. Coliforms and faecal coliforms were also found in significant number of these samples. Thus, the modified H2S test may prove a useful alternative indicator of faecal contamination for water quality surveillance and screening of large number of water samples in short duration, particularly during any outbreak of water borne disease among rural population.  相似文献   

6.
The present study was aimed to make an assessment of health risk due to pollution and human pathogenic bacteria associated with the recreational and drinking water sources in twin densely populated holy Indian cities Ayodhya and Faizabad. Though physicochemical studies revealed that the water available in the area is under recommended limits for human use, it is unsafe on account of poor microbiological quality of surface and ground water in the region. The most probable number (MPN) test results revealed the preponderance of ≥2,400 total coliforms (TC) (100 ml) − 1 in river, pond, dug well and kund waters. Contrary to that, 94% tube wells, 32% hand pumps and 25% piped supply water were under safe limits having <3 TC (100 ml) − 1. The shallow depth (~40 ft), water logging and presence of septic tanks in the near vicinity are the possible reasons of poor microbial quality of hand pump drinking water. The municipal supply water passes along sewage line where loose connections and/or cracks in pipe lead to mixing and contamination. The significant best quality of tube well water evident from the absence of TC could be attributed to the depth of well ≥150 ft and usually their location away from the habitation. A total of 263 bacteria from 186 water samples were isolated, and at least five genera of enteric bacteria from various water sources were identified morphologically and biochemically as Escherichia coli, Klebsiella sp., Enterobacter sp., Shigella sp. and Salmonella sp. The serotyping of 72 E. coli and 36 Salmonella sp. revealed 51 as E. coli O157 and 20 as Salmonella sp. The presence of enteric pathogens in water sources pose threat to human health and therefore call for immediate remedial measures.  相似文献   

7.
Water quality monitoring is essential for the provision of safe drinking water. In this study, we compared a selection of fecal indicators with universal Bacteroidales genetic marker to identify fecal pollution of a variety of drinking water sources. A total of 60 samples were collected from water sources. The microbiological parameters included total coliforms, fecal coliforms, Escherichia coli and fecal streptococci as the fecal indicator bacteria (FIB), Clostridium perfringens and H2S bacteria as alternative indicators, universal Bacteroidales genetic marker as a promising alternative fecal indicator, and Salmonella spp., Shigella spp., and E. coli O157 as pathogenic bacteria. From 60 samples analyzed, Bacteroidales was the most frequently detected indicator followed by total coliforms. However, the Bacteroidales assay failed to detect the marker in nine samples positive for FIB and other alternative indicators. The results of our study showed that the absence of Bacteroidales is not necessarily an evidence of fecal and pathogenic bacteria absence and may be unable to ensure the safety of the water. Further research, however, is required for a better understanding of the use of a Bacteroidales genetic marker as an indicator in water quality monitoring programs.  相似文献   

8.
In a field study 78 water samples were analysed employingFluorocult Brilla Broth (BB) and its performance was comparedwith standard MPN procedure. Out of 78 water samples analysed 56(71.7%) samples yielded positive reactions in BB whereas, 50(64.1%) samples were positive by standard fecal coliform test.A comparative study of fluorogenic and chromogenic mediacontaining substrate -D glucuronide for specificdetection of environmental isolates of 313 thermotolerant E.coli has been undertaken. Five fluorogenic media wereused: Fluorocult MacConkey agar (MCA), Fluorocult ECD agar(ECD), Fluorocult VRB agar (VRB), Fluorocult E. coli0157:H7 agar (ECH7) and Fluorocult Brilla Broth (BB) andChromogenic Chromocult agar (CCA). BB and CCA were found to behighly specific and sensitive media to detect E. coli asall E. coli yielded positive reaction on them. On ECH7 andECD agar 67.5 and 64.9 of E. coli isolates gave positivereaction, respectively. Low sensitivity was observed in case ofMCA and VRB agar in detecting E. coli. The performance ofBB appears to be better when compared with standard MPNprocedure employing MacConkey broth/Brilliant green bile brothin detecting E. coli in drinking water.  相似文献   

9.
Fifty seven isolates of thermotolerant E. coli were recovered from 188 drinking water sources, 45 (78.9%) were typable of which 15 (26.3%) were pathogenic serotypes. Pathogenic serogroup obtained were 04 (Uropathogenic E. coli, UPEC), 025 (Enterotoxigenic E. coli, ETEC), 086 (Enteropathogenic E. coli, EPEC), 0103 (Shiga-toxin producing E. coli, STEC), 0157 (Shiga-toxin producing E. coli, STEC), 08 (Enterotoxigenic E. coli, ETEC) and 0113 (Shiga-toxin producing E. coli, STEC). All the pathogenic serotypes showed resistance to bacitracin and multiple heavy metal ions. Resistance to streptomycin and co-trimazole was detected in two strains whereas resistance to cephaloridine, polymixin-B and ampicillin was detected in one strain each. Transfer of resistances to drugs and metallic ions was observed in 9 out of 12 strains studied. Resistances to bacitracin were transferred in all nine strains. Among heavy metals resistance to As3+ followed by Cr6+ were transferred more frequently.  相似文献   

10.
This study was primarily aimed at investigating the physicochemical and microbial quality of water in 14 such dugouts from five districts in the northern region of Ghana. Results obtained suggest that except for colour, turbidity, total iron and manganese, many physicochemical parameters were either within or close to the World Health Organisation’s acceptable limits for drinking water. Generally, colour ranged from 5 to 750 Hz (mean 175 Hz), turbidity from 0.65 to 568 nephelometric turbidity units (NTU; mean 87.9 NTU), total iron from 0.07 to 7.85 mg/L (mean 1.0 mg/L) and manganese from 0.03 to 1.59 mg/L (mean 0.50 mg/L). Coliform counts in water from all the dugouts in both wet and dry seasons were, however, above the recommended limits for drinking water. Total and faecal coliforms ranged from 125 to 68,000 colony forming units (cfu)/100 mL (mean 10,623 cfu/100 mL) and <?1 to 19,000 cfu/100 mL (mean 1,310 cfu /100 mL), respectively. The poor microbial quality, as indicated by the analytically significant presence of coliform bacteria in all samples of dugout water, strongly suggests susceptibility and exposure to waterborne diseases of, and consequent health implications on, the many people who continuously patronise these vital water resources throughout the year. In particular, more proactive sustainable water management options, such as introduction to communities of simple but cost-effective purification techniques for water drawn from dugouts for drinking purposes, education and information dissemination to the water users to ensure environmentally hygienic practices around dugouts, may be needed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号