首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A cost-effective strategy combining chemical analysis and bioassays for the identification of polar toxic compounds in sewage sludge is reported. ToxAlert 100 bioluminescence inhibition assay was used in combination with chemical analysis involving extraction, clean-up, chromatographic separation and mass spectrometry detection. This methodology was applied to real samples of sludge from three wastewater treatment plants (WWTP) located in Catalonia (Spain) during a 3 month period. In the first step, sewage sludge was lyophilized, treated by sonication with a mixture of methanol and chloroform and finally cleaned up using a sequential solid phase extraction (SSPE) with an octadecylsilica cartridge (C18) in series with a polymeric Lichrolut EN cartridge (Lic EN). In the second step, the toxicity of each fraction of the sludge sample was investigated using the ToxAlert 100. The unequivocal identification and quantification of polar organic cytotoxic substances present in the fractionated extracts were determined by liquid chromatography-mass spectrometry (LC-MS). Major toxic compounds identified were: non-ionic polyethoxylated surfactants (nonylphenol polyethoxylates, alcohol polyethoxylates), their intermediates (polyethylene glycol polyethoxylated, nonylphenol carboxylates and polyethoxylated alcohol carboxylates), linear alkylbenzenesulfonates and heavy metals. The toxic response (in terms of bioluminescence inhibition using ToxAlert 100), defined by the 50% effective concentration (EC50), and the toxicity units (TU) for every standard non-ionic surfactant were calculated. The results provided the identification of polar cytotoxic compounds as well as the evaluation of their contribution to the total toxicity observed in sewage sludge.  相似文献   

2.
为了准确评估厌氧-缺氧-好氧(A2/O)处理工艺对废水毒性的削减效率,采用斑马鱼胚胎急性毒性实验、发光细菌急性毒性实验和小鼠L929细胞毒性实验进行测试,结合理化指标,通过毒性当量(TU)法、平均毒性(AvTx)法、毒性指数(TxPr)法、最敏感测试(MST)法和潜在生态毒性效应(PEEP)法对常州市6家污水处理厂(生活污水、综合废水、化工废水、制药废水)进水和出水的生物毒性进行了评价。结果表明,斑马鱼胚胎的毒性敏感程度最高,3种受试生物的毒性评价结果具有较好的一致性。理化达标的污水处理厂出水仍存在一定的生物毒性效应,出水毒性较大的是综合污水处理厂,排入受纳水体后可能会对周围的生态环境产生潜在的生态风险。A2/O处理工艺对各污水处理厂进水的毒性削减较好,其中对制药废水的毒性削减最高,AvTx、TxPr、MST和PEEP的毒性削减率分别为99.45%、99.64%、99.48%和69.66%。与AvTx、TxPr、MST法相比,PEEP法能够更综合地评价废水毒性。  相似文献   

3.
Bioassay using cultured human cell lines was applied to an effluent of a wastewater treatment plant (WWTP) in Sapporo to assess their toxicity, and in order to investigate the fate of toxicity in the WWTP, bioassay of the water samples from several points in WWTP (influent, effluent, return flow from thickener, from dewatering process and from incineration process) was performed. We also applied bioassay to the mixture of the activated sludge from the investigated plant and artificial sewage. These results showed that the toxicity of the effluent was more intensive than the influent, and organic matter released from activated sludge bacteria during their decay process contributed to the increase of toxicity in the effluent.  相似文献   

4.
Pharmaceuticals and personal care products (PPCPs) represent pollutants of emerging concern, originating in surface and drinking waters largely from their persistence in wastewater effluent. Accordingly, a wealth of recent investigations has examined PPCP fate during wastewater treatment, focusing on their removal during conventional (e.g., activated sludge) and advanced (e.g., ozonation and membrane filtration) treatment processes. Here, we compile nearly 1500 data points from over 40 published sources pertaining to influent and effluent PPCP concentrations measured at pilot- and full-scale wastewater treatment facilities to identify the most effective series of technologies for minimizing effluent PPCP levels. Available data suggest that at best a 1-log(10) concentration unit (90%) of PPCP removal can be achieved at plants employing only primary and secondary treatment, a performance trend that is maintained over the range of reported PPCP influent concentrations (ca. 0.1-10(5) ng L(-1)). Relatively few compounds (15 of 140 PPCPs considered) are consistently removed beyond this threshold at facilities using solids removal and conventional activated sludge (CAS), and most PPCPs are removed to a far lesser extent. Further, increases in CAS hydraulic retention time or sludge retention time do not appreciably increase removal beyond this limit. In contrast, plants employing advanced treatment methodologies, particularly ozonation and/or membranes, remove the vast majority of PPCPs beyond 1-log(10) concentration unit and oftentimes to levels below analytical detection limits in effluent. Data also indicate that passive approaches for tertiary treatment (e.g., wetlands and lagoons) represent promising options for PPCP removal. We conclude by addressing future challenges and frontiers in wastewater management posed by PPCPs including analytical needs for their real-time measurement, energy demands associated with advanced treatment technologies, and byproducts arising from transformation of PPCPs during treatment.  相似文献   

5.
Industrial wastewater typically contains various metal ions. Traditional metal ion treatment processes such as chemical precipitation generate large volumes of toxic sludge which needs to be further solidified or disposed of. The ferrite process (FP), which is another effective approach of treating metal ion-containing wastewater, can crystallize metal ions into ferrites; the sludge easily precipitates, is stable and can be recycling. This investigation explores the feasibility of the Fenton process and the FP (FFP) for treating wastewater that contains metal ions. It considers one factor that adds noise to the FP, ethylenediaminetetraacetic acid, and establishes the optimum parameters of each procedure. The analytical results demonstrate that the proper conditions for Fenton process were pH = 2, [Fe(2+)] = 10(-2) M, H(2)O(2) dosing rate = 5 x 10(-4) mol min(-1), reaction time = 12 min. For the proposed multi-stage FP, the preferred Fe(2+) dosage was 0.098 mol in each stage and the sludge met the toxicity characteristic leaching procedure standards. Following the FFP, the effluent water or the sludge easily met Taiwan's standards. Finally, the SEM test demonstrated that size of the sludge particles was 50-110 nm.  相似文献   

6.
We propose and evaluate a mode-of-action based test battery of low-complexity and in-vitro bioassays that can be used as a routine monitoring tool for sewage treatment efficiency and water quality assessment. The test battery comprises five bioassays covering five different modes of toxic action. The bioluminescence inhibition test with Vibrio fischeri and a growth rate inhibition test with the green algae Pseudokirchneriella subcapitata are measures of non-specific integrative effects. A second endpoint in the algae test, the specific inhibition of the efficiency of photosynthesis, gives an account of the presence of herbicides. An enzymatic assay covers an important aspect of insecticidal activity, the inhibition of the acetylcholine esterase activity. Estrogenic effects are assessed with the yeast estrogen screen (YES) and genotoxicity with the umuC test. Three field studies, each lasting six to seven consecutive days, were undertaken at a sewage treatment plant (STP) in Switzerland. Samples were collected in summer and late autumn, under dry and rainy conditions. None of the bioassays gave positive results with raw water in whole effluent toxicity testing. Therefore, water samples from various sites during wastewater treatment and from surface water were enriched with solid-phase extraction. The focus was on non-volatile compounds of average to moderate hydrophobicity, a range that includes most pesticides, biocides and pharmaceuticals. Various polar solid phases were evaluated for their extraction efficiency, disturbance by matrix components and overall performance. We finally selected a mixture of a polymeric sorbent and a C18-sorbent, Lichrolut EN and RP-18 or, alternatively, Empore SDB-RPS disks. All bioassays gave clear and robust responses with the SPE extracts. With the bioassay data the treatment efficiency of the STP can be assessed with respect to different modes of toxic action and accordingly different groups of micropollutants. Furthermore, the data allowed for a comparison between the effluent and the receiving river. In all bioassays the primary effluent had a strong effect and this effect was reduced after passing the STP. Treatment efficiency was high (typically over 90%) but varied from bioassay to bioassay, which is expected because each bioassay detects different types of micropollutants and therefore we cannot expect a common answer.  相似文献   

7.
Deep bed filtration is becoming increasing important in wastewater treatment particularly in tertiary treatment as stringent water quality standards are emphasized. A detailed pilot-scale filtration study conducted with secondary effluent in a sewage treatment plant indicated that tertiary filtration with prior alum flocculation is capable of producing high quality effluent, particularly an effluent with phosphorus content of less than 0.3 mg/L (Vigneswaran and Ngo, 1994). Main problem of dual media filter has been rapid headloss development thus frequent backwash requirement. To overcome this problem two independent experimental studies were conducted: one with mobile bed filtration (MBF) and the other with combined downflow floating medium flocculator/prefilter (DFF) and coarse sand filter (CSF) system. A semi-pilot scale mobile bed filtration study conducted using oxidation pond effluent indicated that MBF with contact-flocculation arrangement was good in removing COD, T-P and turbidity with practically no headloss development. Sand of 0.6-0.84 nm dia and 50 cm depth was sufficient to reduce the COD and P from 55 mg/L and 4.5 mg/L to 15 mg/L and 0.5 mg/L respectively at a filtration rate of 7.5 m3/m2.h. Another experimental study with combined DFF-CSF system indicated that the DFF with in-line flocculation addition is a good pretreatment unit to reduce the phosphate upto 80-90%. The fact that DFF resulted in uniform filterable-flocs, it can also successfully be used as a static flocculator/prefilter unit. The introduction of DFF on top of a coarse sand filter increased the filter run time and removal efficiency (more 90-95% of NH3-N and T-P removal respectively). Most importantly, the backwashing of this system was achieved with small quantity of water at low backwash indicated that the removal efficiency was also superior with this system apart from the major advantage of low operating cost.  相似文献   

8.
焦化废水中的溶解性有机物(DOM)作为废水污染物和毒性的主要来源受到广泛关注。厌氧-缺氧-好氧(A-A-O)生物法联合混凝沉淀工艺在焦化废水处理中被广泛应用。于2018年4,7和11月分别采集4座焦化废水处理厂废水,采用光谱学分析手段和水生生物急性毒性试验对A-A-O联合混凝沉淀处理过程中焦化废水的DOM和毒性变化进行分析。结果表明,焦化废水中含有大量不饱和芳香性物质,其中类色氨酸、络氨酸物质占主导,其次为类溶解性微生物代谢产物、类富里酸物质和类腐殖酸类物质;未经处理的焦化废水对藻类和大型溞的急性毒性等级为中毒至高毒。A-A-O联合混凝沉淀处理可去除90%以上的类色氨酸、络氨酸和类富里酸物质,但对类腐殖酸类物质去除率相对较低,仅为约80%,关键去除段为缺氧段和好氧段;该工艺对焦化废水急性毒性削减率为80.51%~94.30%,关键削减段为厌氧段。Pearson相关性分析结果显示,焦化废水溶解性总有机碳(TOC)、类腐殖酸类物质荧光组分C1和类富里酸类物质荧光组分C4与废水急性毒性存在显著正相关关系,可利用其作为水样急性毒性初筛的指示性指标。可为焦化废水生化处理的效能优化和废水毒性控制及安全评估提供科学支撑。  相似文献   

9.
Pulp and paper mill effluents may cause harmful effects to the aquatic environment due to the combined influence of physical factors, toxic compounds, and nutrient enrichment. In the present study, the effectiveness of secondary treatment in reducing the toxicity of an elemental chlorine-free bleached-kraft pulp mill effluent was evaluated. To characterize the toxicity of the effluent, before and after the implementation of secondary treatment, a battery of tests with organisms bearing different functions at the ecosystem level was used, namely Vibrio fischeri (5-min luminescence), Pseudokirchneriella subcapitata (72-h growth), Lemna minor (7-day growth), Daphnia magna (21-day reproduction and 24-h postexposure feeding), Chironomus riparius (9-day growth), and Danio rerio (28-day growth). For the effluent sample collected before the implementation of secondary treatment, P. subcapitata was the most sensitive organism followed by V. fischeri and D. magna, and no toxic effects were observed toward the other organisms. For the effluent sample collected after the implementation of secondary treatment, the effluent caused no toxic effects on any of the tested species. The present results demonstrated not only that secondary treatment efficaciously reduced effluent toxicity toward the selected test organisms but also the usefulness of a battery of tests to characterize the toxicity of pulp mill effluents.  相似文献   

10.
采用热带爪蟾胚胎测定江苏省常州市8家典型行业工业废水的发育毒性,结果显示:各行业工业废水对爪蟾胚胎的发育均有不同程度的影响,而印染、啤酒、电镀和化工行业出水的发育毒性更强。试验表明,理化指标并不能完全反映工业废水的综合毒性,而热带爪蟾胚胎可有效地表征其发育毒性。比较各行业工业废水的毒性,初步探讨热带爪蟾胚胎用于工业废水毒性检测的可行性。  相似文献   

11.
Six trace contaminants (acesulfame (ACE), sucralose (SUC), carbamazepine (CBZ), diatrizoic acid (DTA), 1H-benzotriazole (BTZ) and its 4-methyl analogue (4-TTri)) were traced from wastewater treatment plants (WWTPs) to receiving waters and further to riverbank filtration (RBF) wells to evaluate their prediction power as potential wastewater markers. Furthermore, the persistence of some compounds was investigated in advanced wastewater treatment by soil aquifer treatment (SAT). During wastewater treatment in four conventional activated sludge WWTPs ACE, SUC, and CBZ showed a pronounced stability expressed by stable concentration ratios in influent (in) and effluent (out) (ACE/CBZ: in45, out40; SUC/CBZ: in1.8, out1.7; and ACE/SUC: in24, out24). In a fifth WWTP, additional treatment with powdered activated carbon led to a strong elimination of CBZ, BTZ, and 4-TTri of about 80% and consequently to a distinctive shift of their ratios with unaffected compounds. Data from a seven month monitoring program at seven sampling locations at the rivers Rhine and Main in Germany revealed the best concentration correlation for ACE and CBZ (r(2) = 0.94) and also a good correlation of ACE and CBZ concentrations to BTZ and 4-TTri levels (r(2) = 0.66 to 0.82). The comparison of ratios at different sampling sites allowed for the identification of a CBZ point source. Furthermore, in Switzerland a higher consumption of SUC compared to Germany can be assumed, as a steadily increasing ACE/SUC ratio along the river Rhine was observed. In RBF wells a good correlation (r(2) = 0.85) was again observed for ACE and CBZ. Both also showed the highest stability at a prolonged residence time in the subsurface of a SAT field. In the most peripheral wells ACE and CBZ were still detected with mean values higher than 36 μg L(-1) and 1.3 μg L(-1), respectively. Although SUC concentrations in wastewater used for SAT decreased by more than 80% from about 18 μg L(-1) to 2.1 μg L(-1) and 3.5 μg L(-1) in these outlying wells, the compound was still adequate to indicate a wastewater impact in a qualitative way.  相似文献   

12.
This study investigates the impact of wastewater treatment plant (WWTP) effluent on the toxicity of the recipient water body and the effectiveness of the disinfection treatment applied (sodium hypochloride) to assure the compliance of both microbiological and toxicological emission limits. No toxicity was found in the majority of samples collected from the recipient river, upstream and downstream of the WWTP, using three different toxicity tests (Vibrio fischeri, Daphnia magna, and Pseudokirchneriella subcapitata). Only three samples presented toxic unit (TU) values with V. fischeri, and one presented TU with P. subcapitata. The influent toxicity ranged from slightly toxic to toxic (TU = 0.68–4.47) with V. fischeri, while only three samples presented TU values with the other tests. No toxicity was found in the absence of chlorination, while the mean toxicity was 3.42 ± 4.12 TU with chlorination in the effluent. Although no toxicity or very slight toxicity was found in the receiving water, its residual toxicity was higher than the US EPA Quality Standard in two samples. Escherichia coli concentration had a lower mean value in the chlorinated effluent: 13,993 ± 12,037 CFU/100 mL vs. 62,857 ± 80,526 CFU/100 mL for the not chlorinated effluent. This difference was shown to be significant (p < 0.05). E. coli in ten chlorinated samples was higher than the limit established by European and Italian Legislation. The mean highest trihalomethanes (THMs) value was found in the influent samples (2.79 ± 1.40 μg/L), while the mean highest disinfection by-products (DBPs) was found in the effluent samples (1.85 ± 2.25 μg/L). Significant correlations were found between toxicity, sodium hypochlorite, THMs, DBPs, E. coli, and residual chlorine. In conclusion, this study highlighted that the disinfection of wastewater effluents with sodium hypochlorite determines the increase of the toxicity, and sometimes is not enough to control the E. coli contamination.  相似文献   

13.
Soil-aquifer treatment (SAT) of wastewater is an increasingly valued practice for replenishing aquifers due to ease of operation and low maintenance needs and therefore low cost. In this study, we investigated the fate of endotoxins through laboratory-scale SAT soil columns over a four month period. The effluent of rapid sand filtration was run through the columns under gravity flow conditions. Four SAT columns were packed with four different filter materials (fine sand, medium sand, coarse sand and very coarse sand). The effluent of rapid sand filtration (average dissolved organic carbon (DOC) = 4 mg l(-1) and average endotoxin concentration = 4 EU ml(-1)) was collected from a domestic wastewater treatment plant in Sapporo, Japan. DOC removal ranged from 12.5% to greater than 22.5% during the study, with DOC levels averaging 3.1 and 3.5 mg l(-1) for the SAT columns packed with different soils. Endotoxin transformation exhibited different profiles, depending on the time and soil type. Reduction in endotoxin concentration averaged 64.3% and was as high as 86.7% across the soil columns 1, 2, 3 and 4, respectively. While DOC removal was gradual, the reductions in endotoxin levels were rather rapid and most of the removal was achieved in the top layers. Soil with a larger grain size had lower efficiency in removing endotoxin. Tests were performed to evaluate the transformation of organic matter showing endotoxicity and to determine the mechanisms responsible for changes in the structural and size properties of dissolved organic matter (OM) during SAT. Dissolved OM was fractionated using Sep-Pack C18 Cartridges into hydrophobic and hydrophilic fractions. Dialysis tubes with different molecular weight cut-offs were used to perform size fractions of OM showing endotoxicity. Evaluation of the transformation of organic matter showing endotoxicity during SAT indicated that both hydrophobic and large molecules were reduced. Moreover, experimental findings showed that adsorption test data fit to the Freundlich isotherm and were affected by the particle grain size with higher adsorption capacity for fine and medium sand.  相似文献   

14.
Whole effluent toxicity (WET) tests, with Daphnia magna and Selenastrum capricornutum, were introduced to evaluate the biological toxicities of effluents from the wastewater treatment plants (WWTPs) in Korea. In WET tests of WWTPs effluents, 33.3% (33/99) for D. magna and 92.6% (75/81) for S. capricornutum revealed greater than 1 toxic unit (TU), even though all the treatment plants investigated were operating in compliance with the regulations, as assessed using conventional monitoring methods (i.e., BOD and total concentration of N or P, etc). There were only minor differences in toxicities according to the types of influents (municipal and agro-industrial) in all treatment plants. However, the effluents treated by an activated sludge treatment process were found to exhibit significantly lower toxicity than those treated by rotating biological contactor (RBC) and extended aeration processes. The seasonal variations in the toxicity were lower in the summer compared to winter, which may have been due to the rainfall received to the sewage intake system during the former period. The impact of WET on river water was also investigated based on the discharge volume. At sites A and B, the total impact of toxicity to stream and river waters was observed to be 70.9% and 90.4% for D. magna and S. capricornutum, respectively. The other four small treatment plants (sites F, G, H and I), with relative discharging volumes between 0.001 and 0.002, contribute less than 1% to the total toxicity.  相似文献   

15.
Upon partial degradation of polar organic micropollutants during activated sludge treatment, transformation products (TPs) may be formed that enter the aquatic environment in the treated effluent. However, TPs are rarely considered in prospective environmental risk assessments of wastewater-relevant compound classes such as pharmaceuticals and biocides. Here, we suggest and evaluate a tiered procedure, which includes a fast initial screening step based on high resolution tandem mass spectrometry (HR-MS/MS) and a subsequent confirmatory quantitative analysis, that should facilitate consideration of TPs formed during activated sludge treatment in the exposure assessment of micropollutants. At the first tier, potential biotransformation product structures of seven pharmaceuticals (atenolol, bezafibrate, ketoprofen, metoprolol, ranitidine, valsartan, and venlafaxine) and one biocide (carbendazim) were assembled using computer-based biotransformation pathway prediction and known human metabolites. These target structures were screened for in sludge-seeded batch reactors using HR-MS/MS. The 12 TPs found to form in the batch experiments were then searched for in the effluents of two full-scale, municipal wastewater treatment plants (WWTPs) to confirm the environmental representativeness of this first tier. At the second tier, experiments with the same sludge-seeded batch reactors were carried out to acquire kinetic data for major TPs that were then used as input parameters into a cascaded steady-state completely-stirred tank reactor (CSTR) model for predicting TP effluent concentrations. Predicted effluent concentrations of four parent compounds and their three major TPs were corroborated by comparison to 3-day average influent and secondary effluent mass flows from one municipal WWTP. CSTR model-predicted secondary effluent mass flows agreed within a factor of two with measured mass flows and confidence intervals of predicted and measured mass flows overlapped in all cases. The observed agreement suggests that the combination of batch-determined transformation kinetics with a simple WWTP model may be suitable for estimating aquatic exposure to TPs formed during activated sludge treatment. Overall, we recommend the tiered procedure as a realistic and cost-effective approach to include consideration of TPs of wastewater-relevant compounds into exposure assessment in the context of prospective chemical risk assessment.  相似文献   

16.
New environmental standards for protecting aquatic organisms for zinc (e.g., 0.03 mg/L) in surface waters were set in Japan in 2003. Although wastewater effluent might be one of the major pathways of zinc to public water bodies in Japan, current status of concentration of zinc in wastewater effluent was not clear due to higher detection limits (e.g., 0.5 mg/L) than the level required by the new regulations. This study aims at assessing current status of zinc in wastewater effluent in Japan to revise wastewater effluent standards for protecting aquatic organisms. Survey of zinc in wastewater treatment plants (WWTPs) was carried out in Japan in 2005, setting the detection limits at least 0.01 mg/L. The results of the survey suggested the difficulty to remove zinc (especially dissolved zinc) with conventional activated sludge treatment if concentration of zinc in influent was relatively low. And it was suggested that high concentration of dissolved zinc might be derived from some industries discharging high concentration of zinc. The concentration of zinc in wastewater influent without industrial discharges was about 0.1 mg/L which might be lower than that in wastewater from industries discharging high concentration of zinc. Finally, effluent standards for point sources including WWTPs to public water bodies were set at 2 mg/L in 2006. Based on the results of the survey that it was difficult to remove dissolved zinc discharged from industries at WWTPs, the effluent standards from industries to sewerage were set at the same value of the effluent standards from WWTPs to public water bodies.  相似文献   

17.
Chemical coagulation and adsorption, despite many drawbacks, are actually the main techniques used for the removal of pollutants from aqueous solution; however, these techniques are becoming ineffective due to the exponential increase in the amount and complexity of discharged pollutants; thus, the sludge treatment process became a more complex challenge. The present study focuses on the way to reduce the quantity of sludge formed during the removal of Ridomil Gold, a widely used pesticide-fungicide in agriculture. Results revealed that pre-treatment of initial waste solution by the gliding arc (Glidarc), a source of non-thermal plasma, leads to a significant reduction of the sludge formed during the coagulation treatment. For a 20-min pre-treated effluent Glidarc followed by chemical coagulation, there was a reduction in the volume of sludge formed in the order of 90 and 80% for alum and ferric sulfate coagulants respectively without reducing the performance of pesticide removal. Therefore, there is a positive synergism between treatment by chemical coagulation and plasma treatment. These results suggest that the Glidarc can be an effective solution for the reduction of sludge obtained during treatment by coagulation.  相似文献   

18.
Inorganic aluminum ions, [Al(H2O)6]3+, [Al(OH)(H2O)5]2+, and [Al(OH)2(H2O)4]+, are toxic to a number of crops. The aim of this study was to estimate the danger of soil contamination of bioavailable aluminum and heavy metals forms because of alum sludge which was a by-product of water, and wastewater treatment technology using aluminum coagulant is introduced into the soil. Aluminum and selected heavy metal fractionation was carried out in the post-coagulation sludge collected at a water treatment plant (where aluminum was used as a coagulant), fermented sewage sludge at a municipal wastewater treatment plant (which did not apply aluminum coagulant), and soil from water treatment plant as well as the mixtures of sludge and soil. It has been found that post-coagulation sludge used as natural fertilizer is a secondary source of bioavailable aluminum, especially when aluminum coagulants are used during water and wastewater treatment. The evaluation of applicability of the sludge to very weak acidic and acidic agricultural soils was carried out. The authors shall debate the question whether, in this case, the Regulation of EU and Polish Government on sewage sludge should also take the bioavailable aluminum into account and add to the list of the elements whose allowable contents are limited.  相似文献   

19.
多环芳烃(PAHs)是一类极其复杂的有机污染物,衍生物种类较多,1976年美国环保局因其致癌、致畸、致突变将其中的16种列为优先控制污染物。城市污水处理厂作为一个地区污染物迁移和转化的重要媒介,在控制和截断PAHs进入天然水体的过程中扮演着重要的角色。因此,研究污水处理厂中PAHs的浓度水平对于了解和控制PAHs进入天然水体和通过污泥进入到土壤中进而通过食物链危害人类健康具有重要的意义。文章综述了污水处理厂污水和污泥中PAHs的前处理技术、分析方法、浓度水平、生态风险以及国内外污水处理厂污泥土地利用现状。  相似文献   

20.
Toxicity of some organic and inorganic chemicals to microorganisms is an important consideration in assessingtheir environmental impact against their economic benefits.Microorganisms play an important role in several environmentalprocesses, both natural and engineered. Some organic and inorganics at toxic levels have been detected in industrial discharges resulting in plant upsets and discharge permit violations. In addition to this, even though in some cases the effluent wastewater does not exceed the discharge limits,the results of toxicity tests show potential toxicity. Toxicityknowledge of effluents can benefit treatment plant operators inoptimising plant operation, setting pre-treatment standards, and protecting receiving water quality and in establishing sewer discharge permits to safeguard the plant. In the Turkish regulations only toxicity dilution factor (TDF) with fish is part of the toxicity monitoring program of permissible wastewater discharge. In various countries, laboratory studiesinvolving the use of different organisms and protocol for toxicity assessment was conducted involving a number of discharges.In this study, it was aimed to investigate the acute toxicity of textile and metal industry wastewaters by traditional and enrichment toxicity tests and emphasize the importance of toxicity tests in wastewater discharge regulations. The enrichment toxicity tests are novel applications and give anidea whether there is potential toxicity or growth limiting and stimulation conditions. Different organisms were used suchas bacteria (Floc and Coliform bacteria) algae (Chlorella sp.), fish (Lepistes sp.) and protozoan (Vorticella sp.) to represent four tropic levels. The textile industry results showed acute toxicity for at least one organism in 8 out of 23 effluent samples. Acute toxicity for at least two organisms in 7 out of 23 effluent sampling was observed for the metal industry. The toxicity test results were assessed with chemical analyses such as COD, BOD, color and heavy metals. It was observed that the toxicity of the effluents could not be explained by using physicochemical analyses in 5 cases for metal and 4 cases for the textile industries. The results clearly showed that the useof bioassay tests produce additional information about the toxicity potential of industrial discharges and effluents.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号