首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 296 毫秒
1.
This complex study presents indoor and outdoor levels of air-borne fine particles, particle-bound PAHs and VOCs at two urban locations in the city of Kaunas, Lithuania, and considers possible sources of pollution. Two sampling campaigns were performed in January-February and March-April 2009. The mean outdoor PM(2.5) concentration at Location 1 in winter was 34.5 ± 15.2 μg m(-3) while in spring it was 24.7 ± 12.2 μg m(-3); at Location 2 the corresponding values were 36.7 ± 21.7 and 22.4 ± 19.4 μg m(-3), respectively. In general there was little difference between the PM concentrations at Locations 1 and 2. PM(2.5) concentrations were lower during the spring sampling campaign. These PM concentrations were similar to those in many other European cities; however, the levels of most PAHs analysed were notably higher. The mean sum PAH concentrations at Locations 1 and 2 in the winter campaign were 75.1 ± 32.7 and 32.7 ± 11.8 ng m(-3), respectively. These differences are greater than expected from the difference in traffic intensity at the two sites, suggesting that there is another significant source of PAH emissions at Location 1 in addition to the traffic. The low observed indoor/outdoor (I/O) ratios indicate that PAH emissions at the locations studied arise primarily from outdoor sources. The buildings at both locations have old windows with wooden frames that are fairly permissive in terms of air circulation. VOC concentrations were mostly low and comparable to those reported from Sweden. The mean outdoor concentrations of VOC's were: 0.7 ± 0.2, 3.0 ± 0.8, 0.5 ± 0.2, 3.5 ± 0.3, and 0.2 ± 0.1 μg m(-3), for benzene, toluene, ethylbenzene, sum of m-, p-, o-xylenes, and naphthalene, respectively. Higher concentrations of VOCs were observed during the winter campaign, possibly due to slower dispersion, slower chemical transformations and/or the lengthy "cold start" period required by vehicles in the wintertime. A trajectory analysis showed that air masses coming from Eastern Europe carried significantly higher levels of PM(2.5) compared to masses from other regions, but the PAHs within the PM(2.5) are of local origin. It has been suggested that street dust, widely used for winter sanding activities in Eastern and Central European countries, may act not only as a source of PM, but also as source of particle-bound PAHs. Other potential sources include vehicle exhaust, domestic heating and long-range transport.  相似文献   

2.
宣威市和富源县位于我国云南省东北部,是全世界肺癌发病率最高的地区之一。当地居民在不通风的房间内燃烧烟煤做饭或取暖造成了严重的室内空气污染。研究表明,长期暴露在燃煤造成的污染物中是导致两地居民肺癌持续高发的主要原因,多环芳烃是最可疑的致病因子之一。2008年1月,分别用聚胺脂泡沫和玻璃纤维滤膜采集了当地9个点位室内、室外空气中气相和颗粒物相中的多环芳烃,同时采集了对应点位的土壤样品。通过对样品的分析,考察了当地空气和土壤中多环芳烃的污染水平、特征以及来源。结果证明,当地空气和土壤中存在严重的多环芳烃污染,室内污染显著高于室外,然而随着当地工业的发展室外污染同样不可忽视,主成分分析结合比值法证明,当地室内外多环芳烃的主要污染源来自于煤炭的燃烧。对空气颗粒物和土壤中多环芳烃浓度进行了比较,对土壤中多环芳烃的来源进行了验证。  相似文献   

3.
The Building Research Establishment (BRE) has been using diffusive samplers for the study of VOCs in indoor and outdoor air since 1989. The Perkin Elmer type sampler packed with Tenax TA adsorbent is used for the diffusive sampling of C6-C16 organic compounds. This method was applied in a major study of relationships between the environment and child health carried out during 1990-1993 in the Avon area of the UK. The present paper reports results of an investigation into the repeatability of the sampler in outdoor air and measurements of 6 aromatic hydrocarbons inside and outside a home over a 5 year period and inside and outside an office building over a 12 month period. Both the home and the office were located in Hertfordshire, England. Concentrations of VOCs recorded are similar to those found in the Avon area. Higher concentrations of each of the six compounds were recorded inside the home than outside, whilst greater amounts of benzene and toluene were found inside the office than outside. Seasonal variations in concentrations are observed and measurements recorded outdoors are similar to those recorded by other workers.  相似文献   

4.
室内空气有机污染的研究现状   总被引:12,自引:1,他引:11  
主要讨论了室内空气中有机物污染的研究现状。重点介绍了室内空气中多环芳烃 (PAHs)、挥发性有机物(VOCs)、醛类化合物等的污染状况及来源。简要叙述了室内空气污染的影响因素及对人体的健康风险评价。  相似文献   

5.
This paper presents information about airborne mesophilic bacteria in the indoor and outdoor air of child day-care centers (CDCCs) in the city of Edirne, Turkey. Air samples were collected using the Petri plate gravitational settling method from the indoor and outdoor air of CDCCs. Counts of airborne bacteria were measured as colony forming units (CFU) collected by gravity onto Brain Heart Infusion Agar plates (with 5% sheep blood). Samples were taken monthly over a period of 12 months between January and December 2004. A total of 3,120 bacteria colonies were counted on 192 Petri plates. Four groups of culturable bacteria were identified: Gram-positive cocci, Gram-positive bacilli, endospore-forming Gram-positive bacilli, and Gram-negative bacteria. Airborne Gram-positive bacteria were the most abundant at more than 95% of the measured population. While Gram-positive cocci were more common in indoor environments, Gram-positive bacilli were more dominant in outdoor air. Bacteria commonly isolated from CDCCs were identified at a genus level. Staphylococcus (39.16%), Bacillus (18.46%), Corynebacterium (16.25%), and Micrococcus (7.21%) were dominant among the genera identified in the present study. The dominant genera identified in the day-care centers were Staphylococcus, Micrococcus, and Corynebacterium for indoor air and Bacillus, Corynebacterium, and Staphylococcus for outdoor air. Staphylococcus, Streptococcus, Bacillus, and Corynebacterium genera were found in samples from every month. Bacterial colony counts were compared by sampling location (indoors and outdoors), seasons, and meteorological factors. We found negative correlations between the monthly total outdoor bacterial counts and the sampling day’s average relative humidity and average rainfall, and the monthly average rainfall. Fluctuations in bacterial counts in different seasons were observed.  相似文献   

6.
It is costly to sample all air pollutants of a general community. Air sampling should be conducted based on a practical assessment strategy and monitoring plan. In Hong Kong, the Environmental Protection Department (HKEPD) launched an Indoor Air Quality (IAQ) certification scheme to grade workplace IAQ as 'Excellent' or 'Good' by measuring the levels of nine common indoor air pollutants, namely carbon dioxide (CO(2)), carbon monoxide (CO), respirable suspended particulates (RSP), nitrogen dioxide (NO(2)), ozone (O(3)), formaldehyde (HCHO), total volatile organic compounds (TVOC), radon (Rn), and airborne bacteria count (ABC). Although average office IAQ performance has been improved since the implementation of this certification scheme, there are still resource issues and technical difficulties. To streamline the assessment of office IAQ performance, this study proposes a simple index of IAQ benchmarks formulated in compliance with the HKEPD requirements. In particular, three of the nine listed common air pollutants were selected as the 'representatives' for the overall satisfactory IAQ. Together with the assessment results of 422 Hong Kong air-conditioned offices, the index was evaluated in terms of test sensitivity, specificity and predictive values. Proved to be feasible to describe the IAQ of some air-conditioned offices, this IAQ index would be a useful tool for policymakers, building owners and professionals to quantify IAQ performance in offices and to make decisions on resources and manpower management for efficient mitigation actions.  相似文献   

7.
Air pollution is increasingly recognized as a significant contributor to global health outcomes. A methodological framework for evaluating the global health-related outcomes of outdoor and indoor (household) air pollution is presented and validated for the year 2005. Ambient concentrations of PM2.5 are estimated with a combination of energy and atmospheric models, with detailed representation of urban and rural spatial exposures. Populations dependent on solid fuels are established with household survey data. Health impacts for outdoor and household air pollution are independently calculated using the fractions of disease that can be attributed to ambient air pollution exposure and solid fuel use. Estimated ambient pollution concentrations indicate that more than 80% of the population exceeds the WHO Air Quality Guidelines in 2005. In addition, 3.26?billion people were found to use solid fuel for cooking in three regions of Sub Saharan Africa, South Asia and Pacific Asia in 2005. Outdoor air pollution results in 2.7?million deaths or 23?million disability adjusted life years (DALYs) while household air pollution from solid fuel use and related indoor smoke results in 2.1?million deaths or 41.6?million DALYs. The higher morbidity from household air pollution can be attributed to children below the age of 5 in Sub Saharan Africa and South Asia. The burden of disease from air pollution is found to be significant, thus indicating the importance of policy interventions.  相似文献   

8.
The relationship between indoor and outdoor particulate air pollution was investigated at an urban background site on the Payambar Azam Campus of Mazandaran University of Medical Sciences in Sari, Northern Iran. The concentration of particulate matter sized with a diameter less than 1 μm (PM1.0), 2.5 μm (PM2.5), and 10 μm (PM10) was evaluated at 5 outdoor and 12 indoor locations. Indoor sites included classrooms, corridors, and office sites in four university buildings. Outdoor PM concentrations were characterized at five locations around the university campus. Indoor and outdoor PM measurements (1-min resolution) were conducted in parallel during weekday mornings and afternoons. No difference found between indoor PM10 (50.1 ± 32.1 μg/m3) and outdoor PM10 concentrations (46.5 ± 26.0 μg/m3), indoor PM2.5 (22.6 ± 17.4 μg/m3) and outdoor PM2.5 concentration (22.2 ± 15.4 μg/m3), or indoor PM1.0 (14.5 ± 13.4 μg/m3) and outdoor mean PM1.0 concentrations (14.2 ± 12.3 μg/m3). Despite these similar concentrations, no correlations were found between outdoor and indoor PM levels. The present findings are not only of importance for the potential health effects of particulate air pollution on people who spend their daytime over a period of several hours in closed and confined spaces located at a university campus but also can inform regulatory about the improvement of indoor air quality, especially in developing countries.  相似文献   

9.
Indoor air quality at nine locations viz. food courts, restaurant, bar, conference room, office and theater, which can be classified as public places have been monitored for Volatile Organic Compounds (VOCs) content. Forty VOCs have been identified and one fourth of these are classified as Hazardous Air Pollutants. Levels of most VOCs are observed to be below the guideline values for public places and offices, as adopted by Hong Kong. Consumer goods are found to be predominant source of chlorinated VOCs in indoor air. Levels of benzene and carbon tetrachlorides were observed to be above the guideline values at all the locations. Effect of ozonisation on Total VOC concentrations have also been studied.  相似文献   

10.
Air quality in the vicinity of airports is examined with particular reference to a detailed study of Gatwick Airport (UK). Ambient air concentrations of carbon monoxide, hydrocarbons (total and non-methane), oxides of nitrogen, smoke and airborne particulate lead have been measured at seven locations around the airport. The results obtained have been compared with ambient air quality guidelines, where available, and with results from other monitoring sites in the UK. It is concluded that the airport cannot be considered to be a significantly more important contributor to average pollutant ground-level concentrations than other sources in the area.  相似文献   

11.
The aim of this research is to evaluate the ability of transplanted lichen Pseudovernia (P). furfuracea to biomonitor and bioaccumulate in urban indoor environments. The elements As, Cd, Cr, Cu, Hg, Ni and Pb and 12 selected polycyclic aromatic hydrocarbons (PAHs) were used to assess P. furfuracea as a biomonitoring tool for the indoor air quality of school environments. To achieve this purpose, lichen samples were exposed for 2 months in the outdoor and indoor environments of five school settings located in urban and rural areas. The results demonstrated that transplanted lichen P. furfuracea is a suitable biomonitoring tool for metals and PAHs in indoor settings and can discriminate between different levels of air pollution related to urbanisation and indoor conditions, such as those characterised by school environments. A transplanted lichen biomonitoring strategy is cost-effective, “green”, educational for attending children and less “invasive” than traditional air sampling methods. The feasibility of indoor monitoring by P. furfuracea is a relevant finding and could be a key tool to improve air quality monitoring programmes in school scenarios and thus focus on health prevention interventions for children, who are one of the most susceptible groups in the population.  相似文献   

12.
杭州市居室空气中芳香族化合物污染现状及其来源解析   总被引:3,自引:0,他引:3  
用热解吸/气质联用技术研究了杭州市居室空气中芳香族化合物的组成。结果表明,杭州市居室空气中共存在60种芳香族化合物,其中苯系化合物48种,非苯芳香族化合物12种,检出率大于50%的23种;苯、甲苯、乙苯、苯乙烯、邻二甲苯、间(对)-二甲苯等10种化合物的总含量之和大于85.39%,是室内空气中主要的芳香族污染物,除萘外,其他22种污染物的平均浓度值均随装修时间间隔延长而降低;污染物主要来源是室内装修过程中使用的或装修材料中残留的有机溶剂、机动车辆排放的尾气、居民家庭中常用的清洁用品及含萘等成分的防蛀剂。  相似文献   

13.
Air samples were collected from 4 field sites in Europe: 2 sites from the UK, Hazelrigg (semi-rural) and Manchester (urban); 1 site from Ireland: Mace Head (rural); and 1 site from Norway: Kjeller (rural). Additionally, air samples were taken from indoor locations in Troms?, Norway. Air samples were collected using high-volume air samplers employing sampling modules containing glass-fibre filters (GFFs, particle phase), and glass columns with a polyurethane foam (PUF)-XAD-2-PUF sandwich (gaseous phase). Typical outdoor air volumes required for the determination of per- and polyfluorinated alkyl substances (PFAS) ranged from 500-1800 m3. GFFs and PUF-XAD columns were analysed separately to obtain information on phase partitioning. All air samples were analysed for volatile, neutral PFAS, with selected GFF samples halved for analysis of both neutral and airborne particle-bound ionic PFAS. Volatile PFAS were extracted from air samples by cold-column immersion with ethyl acetate, and were analysed by gas chromatography-mass spectrometry in the positive chemical ionisation mode (GC-PCI-MS). Ionic PFAS were extracted from GFFs by sonication in methanol, and were analysed by liquid chromatography-time-of-flight-mass spectrometry (LC-TOF-MS) using electrospray ionisation in the negative ion mode (ESI-). Perfluorooctanoate (PFOA) was often the predominant analyte found in the particulate phase at concentrations ranging from 1-818 pg m(-3), and 8:2 fluorotelomer alcohol (FTOH) and 6:2 FTOH were the prevailing analytes found in the gas phase, at 5-243 pg m(-3) and 5-189 pg m(-3), respectively. These three PFAS were ubiquitous in air samples. Many other PFAS, both neutral and ionic, were also present, and levels of individual analytes were in the 1-125 pg m(-3) range. Levels of some PFAS exceeded those of traditional persistent organic pollutants (POPs). In this study, the presence of 12:2 FTOH and fluorotelomer olefins (FTolefins), and ionic PFAS other than perfluorooctane sulfonate (PFOS) and PFOA, are reported in air samples for the first time. Concentrations of neutral PFAS were several orders of magnitude higher in indoor air than outdoor air, making homes a likely important diffuse source of PFAS to the atmosphere. Our repeated findings of non-volatile ionic PFAS in air samples raises the possibility that they might directly undergo significant atmospheric transport on particles away from source regions, and more atmospheric measurements of ionic PFAS are strongly recommended.  相似文献   

14.
This study was investigated the density and monthly distribution of indoor and outdoor microfungi in six different residential houses in Tekirdag City through the exposure of Petri dishes containing Rose-Bengal Streptomycin Agar media. Samples were collected in 1-month intervals over a period of 12 months between March, 2001, and February, 2002. We used 432 Petri dishes and counted a total of 4,205 microfungi colonies, 1,790 from indoor air and 2,415 from outdoor air. As a result, 42 species belonging to 12 genera were identified. The most frequent fungal genera were Penicillium (28.61%), Cladosporium (16.08%) and Alternaria (15.98%). While Penicillium (40.61%) and Cladosporium (15.92%) were the dominant genera of indoor air, Alternaria (20.62%) and Penicillium (19.71%) were isolated most frequently from outdoor air (Table 3). Alternaria citri (10.15%) and Penicillium brevicompactum (10.15%) were found to be the most frequent among the 42 identified species. While P. brevicompactum (19.55%) and Aspergillus niger (6.37%) were the most frequent indoor species, A. citri (13.37%) and Cladosporium cladosporioides (8.20%) were the most frequent outdoor species. Linear Regression Analysis was applied to determine whether or not there was a relationship between the number of colonies of isolated fungal genera and meteorological factors during the research period. Correlations between the presence of Aspergillus and temperature, relative humidity, duration of sunny periods and agents of air pollution such as SO(2) and PM were statistically significant. No significant correlations, however, were found between other fungal genera and environmental variables.  相似文献   

15.
2-Ethyl-1-hexanol is a possibly causative chemical in sick building symptoms, although 2-ethyl-1-hexanol has received little attention as a hazardous substance in studies on indoor air pollution. Airborne 2-ethyl-1-hexanol concentrations were measured from 2002 to 2004 in 99 rooms of 42 non-domestic buildings in Nagoya, Japan. The diffusive sampling method is effective for the measurement of a low level of 2-ethyl-1-hexanol in indoor air. The geometric mean (geometric standard deviation) of 2-ethyl-1-hexanol concentrations was 16.5 (5.4) microg m(-3) in indoor air and 1.9 (2.2) microg m(-3) in outdoor air. The maximum concentration of 2-ethyl-1-hexanol in indoor air and outdoor air was 2709 microg m(-3) and 12.4 microg m(-3), respectively. Fewer rooms in a small number of new buildings showed high concentrations of 2-ethyl-1-hexanol, while low concentrations were observed in many rooms of these buildings as well as the other new buildings. The room-to-room concentrations of 2-ethyl-1-hexanol in each building exhibited a wide variation. The geometric mean of the 2-ethyl-1-hexanol concentrations was significantly higher for indoor air than for outdoor air (p < 0.01). The correlation of the 2-ethyl-1-hexanol concentrations between indoor and outdoor air was not significant. Mechanical ventilation was effective in the temporary reduction of indoor 2-ethyl-1-hexanol level. These results suggest that the predominant source of 2-ethyl-1-hexanol was indoor areas.  相似文献   

16.
It is more and more recognised that an estimation of the exposure of the population to air pollutants is more relevant than the ambient air quality, since it gives a better indication of health risk. Outdoor workers in an urban region are generally of low income status and are exposed to higher levels of both indoor and outdoor air pollution. Hence respondents from this population subgroup have been selected for this study. Outdoor workers are divided into two categories, viz. traffic constables and casual outdoor workers like watchmen, roadside shopkeepers etc. Most of the respondents are from the lower income group. Each respondent is monitored for a continuous 48-hour period. The sampling frequency is once a week.The study region is situated in the north-west part of the Greater Mumbai Municipal Corporation. It can be classified as industrial cum residential area. The daily integrated exposure of the outdoor workers consists of two major micro-environments, viz. occupational and indoor residential.A personal air sampler was used along with a cyclone to measure levels of Respirable Particulate Matter (RPM). The cyclone has a 50% removal efficiency for particle diameter of 5 m. Paired samples of PM10 (ambient) and RPM (personal) were collected to establish the correlation between them. The average 24-hour integrated exposure to RPM was 322 g/m3 and exceeded the corresponding PM10 level observed at the nearest Ambient Air Quality Monitoring Station by a factor of 2.25. The 90% confidence interval for this exposure is 283–368 g/m3. This study clearly demonstrates that the daily integrated exposure and therefore the health risk of outdoor workers in an urban area is significantly more serious than that indicated by ambient air quality data.  相似文献   

17.
18.
The aim of this study is to examine the relative contribution of the outdoor concentration, the ventilation rate, the geometric characteristics of the indoor environment (i.e., extent of indoor surfaces and indoor volume), the deposition, and chemical reactions to the indoor air quality of the office microenvironment. For this case study, the NO, NO2, and O3 concentrations indoors and outdoors and TVOCs and CO2 concentrations indoors were measured in an office microenvironment in Athens, Greece, that was ventilated both naturally and mechanically. The calculated ventilation and loss rates and the measured outdoor concentrations of NO, NO2, and O3 were set as input to Multi-chamber Indoor Air Quality Model in order to study the temporal variation of the indoor NO, NO2, and O3 concentrations. Results showed that when the ventilation rate and outdoor concentration are high, the relative contribution of the transport process contributes significantly, while the chemical process depends on the contemporary interplay between the indoor O3, NO, and NO2 concentrations and lighting levels. The significance of each process was further examined by performing sensitivity tests, and it was found that the most important parameters were the deposition velocities, the UV infiltration rates (which determines the indoor chemical reaction rates), the ventilation rates, and the filtration (when a mechanical ventilation system is used). The effect of the hydrocarbon chemistry was not significant.  相似文献   

19.
学龄儿童肺功能水平影响因素的研究   总被引:1,自引:0,他引:1  
用逐步回归分析方法对与室内、外空气污染和机体状况等有关的因素对广州市学龄儿童肺功能 (FVC、FEV1 、PEFR和 FEF2 5~ 75 )水平的影响进行研究。结果提示 ,影响肺功能水平的主要因素是内因 ,身高的影响最明显 ,呼吸系统疾病或症状发生与肺功能水平下降有关 ;室外空气污染使肺功能水平下降 ,SO2 、NOx 和 PM2 .5 的影响明显 ,PM2 .5 的影响明显大于 PM1 0 和 TSP;居室或厨房通风不良、家庭烹饪用不洁燃料对儿童肺功能的生长不利 ;被动吸烟对女性儿童肺功能有不利影响。对各种影响因素 ,PEFR和 FEF2 5~ 75 比 FVC和 FEV1 更为敏感  相似文献   

20.
Air concentrations of 28 of the most commonly used household pesticides were measured inside nine homes in Jacksonville, Florida, and compared with corresponding outdoor levels. The households selected were sorted into three categories according to the degree of pesticide indoor usage. Personal air monitoring was also performed on one resident of each household by means of a portable sampler, which was kept with the person at all times. Five of the pesticides were found in the air inside of the majority of the homes at concentrations as high as 15 gm–3 (average concentrations, 12 ngm–3 to 2.4 gm–3). Indoor levels were generally one to two ordrrs of magnitude higher than surrounding outdoor air levels and personal air measurements were within ± 50% of corresponding indoor values. All samples were collected over 24-hr periods on polyurethane foam and analyzed by capillary colum gas chromatography with mass spectrometric and/or electron capture detection.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号