首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 28 毫秒
1.
A method has been developed for concurrent analysis of C2-C7 hydrocarbons and C2-C5 oxygenated volatile organic compounds (o-VOCs) including alcohols, aldehydes, ketones and ethers. A multi-bed, Peltier-cooled adsorbent trap, consisting of Carboxen 1000 and Carbopack B, was used to acquire one sample per hour. Upon injection the sample was split in an approximately 50:50 ratio between a 50 m aluminium oxide (Al2O3) porous layer open tubular (PLOT) column and a 10 m LOWOX column. Eluents from each column were then analysed using flame ionisation detection (FID). Regular calibration of the system was performed using a standard cylinder mixture at the parts per billion by volume (ppbV) level for non-methane hydrocarbons (NMHCs) and a permeation tube method for the oxygenated species. The system is fully automated with NMHC detection limits between 1 and 10 parts per trillion by volume (pptV) and o-VOC detection limits between 10 and 40 pptV.  相似文献   

2.
针对现有TH_PKU-300B挥发性有机机物快速在线监测系统在测定含氧挥发性有机化合物(OVOCs)、含氮挥发性有机物(NVOCs)和高沸点挥发性有机物时存在灵敏度低、精密度差、线性响应较差、记忆效应明显等不足,根据其原理,对其GC-MS通道的部分气路进行改进。通过实验对比分析,证明改进后的仪器系统响应更加灵敏、线性拟合度更高、精密度及解析效率均显著提高,同时检出限也由改进前的体积分数0.1×10~(-9)~1.0×10~(-9)降低至0.02×10~(-9)~0.08×10~(-9),并解决了记忆效应问题。改进后的系统在OVOCs、NVOCs和高沸点挥发性有机物测定方面要优于原系统。  相似文献   

3.
不同类型机动车尾气挥发性有机化合物排放特征研究   总被引:7,自引:0,他引:7  
机动车尾气主要成分包括一氧化碳、氮氧化物、碳氢化合物、铅及苯并[a]芘等.其中,挥发性有机化合物由于其对光化学烟雾的贡献及对人体健康的影响而成为近年来大气化学研究的热点.文章首次对北京市9种车辆、5种燃料在不同工况下排放挥发性有机化合物特征进行了定量研究.结果表明,车型、燃料、净化器及工况等因素对排放量产生影响,电喷车比化油器车排放低,其中,夏利比富康与奥迪排放量高;LPG与汽油车排放量最高,柴油车与CNG车排放最低.其中,-10#柴油车比0#柴油车排放更低;使用净化器可以降低挥发性有机化合物排放量;不同工况对排放量的影响随车型、燃料类型的不同而不同.因此,使用清洁燃料、安装净化器和使用电喷装置,可减少尾气中挥发性有机化合物含量.  相似文献   

4.
Studies have shown that biogenic compounds, long chain secondary compounds and long lifetime anthropogenic compounds are involved in the formation of organic aerosols in both polluted areas and remote places. This work aims at developing an active sampling method to monitor these compounds (i.e. 6 straight-chain saturated aldehydes from C6 to C11; 8 straight-chain alkanes from C9 to C16; 6 monoterpenes: α-pinene, β-pinene, camphene, limonene, α-terpinene, & γ-terpinene; and 5 aromatic compounds: toluene, ethylbenzene, meta-, para- and ortho-xylenes) in remote areas. Samples are collected onto multi-bed sorbent cartridges at 200 mL min(-1) flow rate, using the automatic sampler SyPAC (TERA-Environnement, Crolles, France). No breakthrough was observed for sampling volumes up to 120 L (standard mixture at ambient temperature, with a relative humidity of 75%). As ozone has been shown to alter the samples (losses of 90% of aldehydes and up to 95% of terpenes were observed), the addition of a conditioned manganese dioxide (MnO(2)) scrubber to the system has been validated (full recovery of the affected compounds for a standard mixture at 50% relative humidity--RH). Samples are first thermodesorbed and then analysed by GC/FID/MS. This method allows suitable detection limits (from 2 ppt for camphene to 13 ppt for octanal--36 L sampled), and reproducibility (from 1% for toluene to 22% for heptanal). It has been successfully used to determine the diurnal variation of the target compounds (six 3 h samples a day) during winter and summer measurement campaigns at a remote site in the south of France.  相似文献   

5.
During a monitoring campaign concentrations of volatile organic compounds (VOCs) were measured in indoor air of 79 dwellings where occupants had not complained about health problems or unpleasant odour. Parameters monitored were the individual concentration of 68 VOCs and the total concentration of all VOCs inside the room. VOCs adsorbed by Tenax TA were then analysed by means of thermal desorption, gas chromatography and mass spectrometry. The analytical procedure and quantification was done according to the recommendation of the ECA-IAQ Working Group 13 which gave a definition of the total volatile organic compound (TVOC) concentration. Using this recommendation TVOC-concentrations ranged between 33 and 1600 microg m(-3) with a median of 289 microg m(-3). Compounds found in every sample and with the highest concentrations were 2-propanol, alpha-pinene and toluene. Save for a few samples, all concentrations measured have been a factor 2 to 10 lower, compared to data from similar studies. Only a few terpenes and aldehydes were found exceeding published reference data or odour threshold concentrations. However, it has been found that sampling and analysing methods do have a considerable impact on the results, making direct comparisons of studies somewhat questionable. 47% of all samples revealed concentrations exceeding the threshold value of 300 microg TVOC m(-3) set by the German Federal Environmental Agency as a target for indoor air quality. Using the TVOC concentration as defined in the ECA-IAQ methodology is instrumental in assessing exposure to VOCs and identifying sources of VOCs. The background concentrations determined in this study can be used to discuss and interpret target values for individual and total volatile organic compounds in indoor air.  相似文献   

6.
The present study focused on monitoring the concentration of 14 halogenated volatile organic compounds in surface waters, including sea, estuarine, river water and industrial effluents in order to determine the most ubiquitous compounds and their concentration levels, which were used to establish their geographical and temporal distribution. EPA Method 502, based on purge and trap techniques, was used. In this method volatile organic pollutants are extracted (purged) from the water sample by bubbling inert gas through the aqueous sample. Purged sample components are trapped in a cartridge containing the polymeric sorbent Tenax and, thereafter, the cartridge is heated and backflushed with helium to desorb the trapped sample components directly into a gas chromatograph with electron capture detector (GC-ECD). The linearity range of the method varied from 0.1 to 4 microg L(-1) with a limit of detection at the low microg L(-1) level. The present study consisted of a monthly monitoring of 46 points throughout Portugal, during 14 months. Chloroform was found in 50% of the samples analyzed, its presence being correlated to both agricultural and industrial activities. Other compounds detected were tetrachloroethylene, trichloroethylene, carbon tetrachloride and 1,2,4 trichlorobenzene, which were present in 10-20% of the samples at concentrations up to 18 microg L(-1). 1,1,2,2-Tetrachloroethane and its degradation product 1,1,2-trichloroethane were found in 5% of the samples, the levels of the latter being higher than those of the parent compound in most samples. Sporadic high concentrations of some volatile halogenated organic compounds were attributed to local uses as solvents.  相似文献   

7.
Worshipping activity is a customary practice related with many religions and cultures in various Asian countries, including India. Smoke from incense burning in religious and ritual places produces a large number of health-damaging and carcinogenic air pollutants include volatile organic compounds (VOCs) such as formaldehyde, benzene, 1,3 butadiene, styrene, etc. This study evaluates real-world VOCs emission conditions in contrast to other studies that examined emissions from specific types of incense or biomass material. Sampling was conducted at four different religious places in Raipur City, District Raipur, Chhattisgarh, India: (1) Hindu temples, (2) Muslim graveyards (holy shrines), (3) Buddhist temples, and (4) marriage ceremony. Concentrations of selected VOCs, respirable particulate matter (aerodynamic diameter, <5 μm), carbon dioxide, and carbon monoxide were sampled from the smoke plumes. Benzene has shown highest emission factor (EF) among selected volatile organic compounds in all places. All the selected religious and ritual venues have shown different pattern of VOC EFs compared to laboratory-based controlled chamber studies.  相似文献   

8.
Proton transfer reaction-mass spectrometry (PTR-MS) is a new and emerging technique for the measurement and monitoring of volatile organic compounds (VOCs) at low concentrations in gaseous samples in more-or-less real time. Utilising chemical ionisation, it combines the desirable attributes of high sensitivity and short integration times with good precision and accuracy. Recently it has been exploited in applications related to atmospheric science. Here, the principles of operation of the PTR-MS are described, its advantages and disadvantages discussed, its inherent uncertainties highlighted, some of its uses in atmospheric sciences reviewed, and some suggestions made on its future application to atmospheric chemistry.  相似文献   

9.
Exposure to vapours of volatile chemicals is a major occupational and environmental health concern. Toxicity testing of volatile organic compounds (VOCs) has always faced significant technological problems due to their high volatility and/or low solubility. The aim of this study was to develop a practical and reproducible in vitro exposure technique for toxicity testing of VOCs. Standard test atmospheres of xylene and toluene were generated in glass chambers using a static method. Human cells including: A549-lung derived cell lines, HepG2-liver derived cell lines and skin fibroblasts, were grown in porous membranes and exposed to various airborne concentrations of selected VOCs directly at the air/liquid interface for 1 h at 37 degrees C. Cytotoxicity of test chemicals was investigated using the MTS (3-(4,5-dimethylthiazol-2-yl)-5-(3-carboxymethoxyphenyl)-2-(4-sulfophenyl)-2H-tetrazolium) and NRU (neutral red uptake) assays following 24 h incubation. Airborne IC(50) (50% inhibitory concentration) values were determined using dose response curves for xylene (IC(50)=5350+/- 328 ppm, NRU; IC(50)=5750+/- 433 ppm, MTS in skin fibroblast) and toluene (IC(50)=0 500+/- 527 ppm, NRU; IC(50)=11,200 +/- 1,044 ppm, MTS in skin fibroblast). Our findings suggest that static direct exposure at the air/liquid interface is a practical and reproducible technique for toxicity testing of VOCs. Further, this technique can be used for inhalational and dermal toxicity studies of volatile chemicals in vitro as the exposure pattern in vivo is closely simulated by this method.  相似文献   

10.
The interest in the identification of volatile organic compounds in the workplace has been a major focus of many National Institute for Occupational Safety and Health (NIOSH) field studies. A primary technique for sampling and analysis of these compounds is summarized by NIOSH Manual of Analytical Methods (NMAM) 2549. This is a screening method that uses a multi-bed sorbent to trap a wide variety of compounds and compound classes. Thermal desorption techniques are used as a first attempt to characterize potential contaminants in a workplace and to determine what future sampling and analyses must be performed. Field examples are provided to show the versatility of thermal desorption methods and techniques. Due to their sensitivity, thermal desorption tube methods are sometimes required in order to measure the workplace concentrations of unusual compounds. In other situations, the exposures are too high or varied to make thermal desorption tubes practical. In these cases, the identification of contaminants with thermal desorption tubes leads to new method developments for the quantification of specific compounds using more conventional solid sorbent-solvent desorption based methods.  相似文献   

11.
南京市环境空气挥发性有机物监测方法比对研究   总被引:1,自引:1,他引:0  
2018年9月20—29日,开展了南京市环境空气非甲烷烃(PAMS)原清单中57种挥发性有机物的手工和在线比对监测,监测项目主要包括碳氢化合物、卤代烃和含氧挥发性有机物。通过对VOCs 3 h均值、日均值和主要污染物指标等进行比对,分析在线监测数据与手工监测数据的相关性。测试结果表明,两种方法得到的3 h均值的差异度(1.43)和相关系数(0.897),日均值的差异度(2.16)和相关系数(0.946),呈现出差异度不显著、高度线性相关的特征。同时,进一步分析了监测数据产生偏离的原因,建议加强环境空气手工监测的质控管理,强化在线监测设备的运维管理,推进环境空气挥发性有机物监测的合理、有序发展。  相似文献   

12.
The strategy for decreasing volatile organic compound emissions in Mexico has been focused much more on tailpipe emissions than on evaporative emissions, so there is very little information on the contribution of evaporative emissions to the total volatile organic compound inventory. We examined the magnitudes of exhaust and evaporative volatile organic compound emissions, and the species emitted, in a representative fleet of light-duty gasoline vehicles in the Metropolitan Area of Mexico City. The US “FTP-75” test protocol was used to estimate volatile organic compound emissions associated with diurnal evaporative losses, and when the engine is started and a journey begins. The amount and nature of the volatile organic compounds emitted under these conditions have not previously been accounted in the official inventory of the area. Evaporative emissions from light-duty vehicles in the Metropolitan Area of Mexico City were estimated to be 39 % of the total annual amount of hydrocarbons emitted. Vehicles built before 1992 (16 % of the fleet) were found to be responsible for 43 % of the total hydrocarbon emissions from exhausts and 31 % of the evaporative emissions of organic compounds. The relatively high amounts of volatile organic compounds emitted from older vehicles found in this study show that strong emission controls need to be implemented in order to decrease the contribution of evaporative emissions of this fraction of the fleet.  相似文献   

13.
This study is part of a three-year project on biogenic volatile organic compound (VOC) emissions from trees of the temperate warm Atlantic rainforest found in the metropolitan area of Sao Paulo City (MASP). No study of VOC emission rates from plant species has been carried out in the temperate warm Atlantic rainforest of Brazil prior to this work. Eleven species were selected (Alchornea sidifolia, Cupania oblongifolia, Cecropia pachystachia, Syagrus romanzoffiana, Casearia sylvestris, Machaerium villosum, Trema micrantha, Croton floribundus, Myrcia rostrata, Solanum erianthum and Ficus insipida) and some of them were studied in urban, sub-urban and forest areas inside the MASP in order to evaluate biogenic VOC composition at sites characterized by different emission sources. Biogenic VOC emissions were determined by placing branches of plants in a dynamic enclosure system, an all-Teflon cuvette, and by sampling the compounds in the air leaving the cuvette. Pre-concentration using adsorbents to retain the VOC, followed by GC-MS after thermal desorption of the sample, was employed to determine the amount of biogenic hydrocarbons. The collection of carbonyl compounds on a 2,4-dinitrophenylhydrazine coated silica followed by HPLC-UV was used to analyze low molecular weight carbonyl compounds. Emission rates of isoprene, alpha-pinene, camphene and limonene ranged from 0.01 to 2.16 microg C h(-1) g(-1) and emission rates of aldehydes (C(2)-C(6)), acrolein, methacrolein and 2-butanone ranged from 1.5 x 10(-2) to 2.3 micro g C h(-1) g (-1). Ambient and leaf temperatures, relative humidity, light intensity, O(3) and NO(x) levels in the local atmosphere were monitored during experiments. It was possible to identify different biogenic VOCs emitted from typical plants of temperate warm Atlantic rainforest. The emission rates were reported as a function of the type of site investigated and were only provided for compounds for which quantification was feasible. Other biogenic compounds were only identified.  相似文献   

14.
High resolution gas chromatography - mass spectrometry (GC-MS) has been widely used in the field of environmental sample analysis for volatile organic compounds (VOCs) (Gryder-Boutet, et al., 1988). Such a technique was applied to the analysis of VOCs at a local municipal wastewater treatment plant. The combination of purge and trap sample preparation and thermal desorption with cryofocusing technology, allows for the detection of a wide range of volatiles in wastewater and sludge samples. Results show that a large variety of organics present in samples are aliphatic and aromatic hydrocarbons. Their concentrations are in part per billion levels between 10 to 150 g/L. Others identified using this method are chlorinated hydrocarbons, sulfides and organic acids. By comparing the chromatograms of different wastewater and sludge samples collected from various treatment process units, it can be seen that most volatiles were removed or degraded after the aeration or digestion process. Information that provides an insight to the measurement of organic compounds in sludges is also discussed in this paper.  相似文献   

15.
Testing of metal compounds for solubility in artificial fluids has been used for many years to assist determining human health risk from exposure to specific compounds of concern. In lieu of obtaining bioavailability data from samples of urine, blood, or other tissues, these studies measured solubility of compounds in various artificial fluids as a surrogate for bioavailability. In this context, the measurement of metal "bioaccessibility" can be used as an in vitro substitute for measuring metal bioavailability. Bioaccessibility can be defined as a value representing the availability of metal for absorption when dissolved in in vitro surrogates of body fluids or juices. The aim of this study was to measure and compare the bioaccessibility of selected cobalt compounds in artificial human tissue fluids and human serum. A second aim was to initiate studies to experimentally validate an in vitro methodology that would provide a conservative estimate of cobalt bioavailability in the assessment of dose from human exposure to various species of cobalt compounds. This study evaluated the bioaccessibility of cobalt(II) from 11 selected cobalt compounds and an alloy in 2 physical forms in 5 surrogate human tissue fluids and human serum. Four (4) separate extraction times were used up to 72 hours. The effect of variables such as pH, dissolution time, and mass-ion effect on cobalt bioaccessibility were assessed as well. We found that the species of cobalt compound as well as the physico-chemical properties of the surrogate fluids, especially pH, had a major impact on cobalt solubility. Cobalt salts such as cobalt(II) sulfate heptahydrate were highly soluble, whereas cobalt alloys used in medical implants and cobalt aluminate spinels used as pigments, showed minimal dissolution over the period of the assay.  相似文献   

16.
Considerable uncertainties are associated with the experimental estimates of emission rates of different volatile organic compound (VOC) species from the biosphere to the atmosphere. Some of this uncertainty derives from the sampling and analytical procedures used in emission rate measurements. A calibration system was developed in order to evaluate possible errors in the measurements of biogenic emission rates using a branch enclosure system. Two types of calibration procedures were tested, a standard additions technique and an internal standard procedure. Both techniques were used to evaluate possible losses while sampling isoprene and monoterpenes, which are the most abundant VOCs of biogenic origin. The losses to Teflon lines and the empty sampling system were tested and losses to the branch enclosure system installed on two VOC emitting plant species were evaluated. A considerable loss of isoprene (approximately 18% of inflow concentration 65 ng l(-1)) to the empty enclosure system and to the system installed on the plant was measured, but no losses of monoterpenes were observed.  相似文献   

17.
针对室内空气挥发性有机物测定方法的不足,本文采用预冷浓缩系统和气相色谱,质谱联用。建立了测定室内空气中39种挥发性有机物的分析方法,该方法采用苏码罐采样,经液氮预冷冻浓缩后,用心城由检测。该方法灵敏度高,操作简便、重现性好、准确度高,适用于室内空气中挥发性有机物的测定。  相似文献   

18.
土壤中挥发性有机物的顶空制备方法研究   总被引:2,自引:0,他引:2  
对土壤中挥发性有机物(VOCs)有效提取的顶空(HS)前处理条件进行了研究。结果表明,在一定的气相色谱条件下,影响顶空装置对挥发性有机物提取水平的主要有顶空平衡时间、平衡温度、基准修正液的加入量等因素,在一定的HS—GC条件下,土壤中挥发性有机物的准确度可达80%。  相似文献   

19.
使用保留时间锁定软件 (RTL) ,在气相色谱体系中建立了水质中 5 3种挥发性有机物的保留时间数据库 ,使原始的保留时间成为化合物定性的可靠参数 ,实现了未知样品在色谱仪上的定性 ,提高了分析效率。  相似文献   

20.
宁波市环境空气中VOCs污染状况及变化趋势分析   总被引:7,自引:4,他引:3  
基于近7年来的连续监测数据,对宁波市环境空气中挥发性有机物(VOCs)的污染状况及变化趋势进行了初步分析。研究表明:在宁波市环境空气中检测出94种VOCs,其主要成分是饱和烷烃、芳烃、烯烃、卤代烃、卤代芳烃、含氧有机物等,有37种属有毒有害物质,其中苯系物含量最高;宁波市环境空气中苯系物的污染程度与国内外城市基本处于同一水平,近年来的污染状况变化不大,没有明显恶化;空间分布特征显示一类保护区VOCs的排放以天然源为主,二类各功能区VOCs的排放由天然源和局部人为污染源共同形成,三类区以工业污染源排放为主;时间变化趋势显示VOCs在冬季和春季的平均浓度比其他季节高,VOCs的日变化基本呈现2个主浓度峰值特征,跟城市交通流量变化具有很好相关性。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏