首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 631 毫秒
1.
The removal of copper and nickel from aqueous solution on the Na-bentonite has been studied under static conditions. Experiments were carried out as a function of solution pH, dosage of Na-bentonite, contact time and temperature. The adsorption equilibrium for nickel and copper onto Na-bentonite is reached in 200 min. The adsorption of copper and nickel is pH dependent in the pH range 2–9. The kinetic process of adsorption can be described by the pseudo-second-order kinetic equation excellently and the adsorption isotherm be fitted to the Langmuir model by means of regression analyses very well. The adsorption capacities follow the order of Cu2+ > Ni2+ in single-component systems and competitive adsorption capacities in order decreasing is Cu2+ > Ni2+ in binary-component systems.  相似文献   

2.
This study aims to develop a methodology for analysis of characteristics of heavy metals in MSWI fly ash. It performed analysis of composition of heavy metals, leaching toxicity, leaching behavior as a function of pH, specification distribution and corresponding mineral components of residue derived from each step of the sequential extraction. It is found that content of heavy metals follows the sequence of Zn > Pb > Cu > Cr > As > Ni > Cd approximately Hg in both plants, and that total heavy metals account for less than 1% by mass of fly ash. Major hazardous heavy metals in fly ash are As, Cd, Hg, Pb and Zn, whose leaching ratios exceed the limit value described in hazardous waste identification standard. Measured leaching results of Cu, Pb and Zn are essentially consistent with the simulated results at pH between 0 and 13. Content of calcium-silicates, alumino-silicates and glass phases in residue derived from sequential extraction procedure increases steadily from the first step to the fifth step of the sequential extraction procedure. Cu, As, Cr, Hg, Cd, and Ni, relatively stable under strong basic conditions, can be leached out under strong acidic conditions, while Zn and Pb tend to be leached out under both strong acidic and basic conditions.  相似文献   

3.
The removal of heavy metals from aqueous effluents so as to avoid their toxic, bioaccumulation and biomagnification effects to humans and environment is usually realized by means of physical, chemical treatment, and biological processes. The aim of this study is to evaluate the potential of rapeseed waste from biodiesel production as a biosorbent for Zn(II) ions.The ability of the rapeseed waste for Zn(II) biosorption exhibited a maximum at pH 4.5–5. The removal efficiency of Zn(II) from solution with an initial concentration of 72 mg L−1 varied from 39% to 89% for an increase of the rapeseed waste dose from 2 to 30 g L−1. The amount of Zn(II) retained on the tested rapeseed increased with increasing metal ion concentration, but the Zn(II) sorption percentage decreased. The equilibrium data are fitted to the Langmuir isotherm better than to the Freundlich isotherm. The kinetics of Zn(II) biosorption process follows a pseudo-second order model. The thermal stability of the rapeseed before and after Zn(II) biosorption was studied by thermogravimetric analysis. It was found that the zinc loaded rapeseed exhibits a better initial thermal stability than the original rapeseed, presumably due to the cross linking generated by the intermolecular complexation of Zn(II) ions. In both cases, the thermal decomposition takes place according to some reassembling kinetic models, in two phases with order n reactions. The results of this study strongly suggest the possibility to use rapeseed as an effective biosorbent for Zn(II) ions removal from aqueous effluents (municipal/industrial wastewaters).  相似文献   

4.
The effects of some commonly used pH conditioners, viz., lime, banana ash, the carbonate and the bicarbonate of sodium and potassium and their binary mixture, on simultaneous removal of arsenic and iron ions from water have been studied. KHCO3 has been found to be the most suitable pH conditioner for the purpose. About 80 mg/L KHCO3 can remove both arsenate and iron ions from initial 250 μg/L and 20 mg/L to below their respective guideline values of the WHO for drinking water, retaining the final pH in the acceptable range for drinking. The simultaneous removal of arsenate and iron by the pH-conditioners decreases in the order: Lime > KHCO3 > NaHCO3 > K2CO3 > Na2CO3 > ash. However, lime requires post-treatment correction of highly alkaline pH. The arsenate ion is removed predominantly through goethite or ferrihydrite in the presence of the bicarbonates and through ferric hydroxide in the presence of the more alkaline pH-conditioners. KHCO3 is more advantageous over the more basic substances including NaHCO3, because with it, one not only needs the smallest dose but also can avoid careful adjustment of the dose for regulating the initial and the final pH. The paper clearly demonstrates the potential of KHCO3 to substitute the currently used pH-conditioners, viz., ash, lime and NaHCO3 for simultaneous removal of arsenate and iron ions.  相似文献   

5.
In this research, treatability of high-load compost leachate in a hybrid expanded granular sludge bed (EGSB) and fixed-bed (FB) bioreactor followed by electrocoagulation–flotation (ECF) system was examined. The operational factors in EGSB–FB were influent chemical oxygen demand (COD), hydraulic retention time (HRT) and COD/nitrogen ratio (COD/N). And, their interactive effects on the efficiency of COD removal and biogas production rate (BPR) as responses were analyzed and correlated by response surface methodology (RSM). The optimum conditions of the hybrid EGSB–FB reactor were acquired at COD = 7800 mg/L, HRT = 35 h, COD/N = 70, in which COD removal efficiency was 83% and BPR 94 mL/h. The amount of confidence interval was 95%. COD (relevant coefficient = 9.8) and HRT (relevant coefficient = −24) were resulted respectively as the most effective parameters on COD removal and BPR. Yet, COD/N parameter imposed negative effect on COD removal and BPR in values less than about 100. The outcomes indicated that operated ECF as post-treatment in constant conditions (electrolysis time = 75 min, electrodes distance = 3 cm, voltage = 20 V) successfully satisfied discharge criteria in the most part of experimental domains.  相似文献   

6.
An ozonation process was performed using a recycled electrochemical ozone generator system. A titanium based electrode, coated with nanocomposite of Sn–Sb–Ni was applied as anode in a laboratory-made electrochemical reactor. A constant flow rate of 192 mg/h of generated ozone was entered to an ozonation reactor to contact with a typical target pollutant, i.e., Rhodamine B (Rh.B) molecules in aqueous solution. Four operational parameters such as: initial dye concentration, pH, temperature and the contact time were evaluated for the ozonation process. Experimental findings revealed that for a solution of 8 mg/L of the dye, the degradation efficiency could reach to 99.5% after 30 min at pH 3.7 and temperature of 45 °C as the optimum conditions. Kinetic studies showed that a second order equation can describe the ozonation adequately well under different temperatures. Also, considering to the importance of process simulation, a three-layered feed forward back propagation artificial neural network model was developed. Sensitivity analysis indicated order of the operational parameter's relative importance on the model output as: time  pH > Rh . B initial concentration > temperature.  相似文献   

7.
Nitrates constitute one of the main toxic contaminants of groundwater. On the other hand, groundwater may be considered anoxic (oxygen concentration less than 9 μg L?1). This fact justifies the use of nano zero valent metals for nitrate removal. In such conditions, zero valent metals are quite stable against oxidation due to the very low level of dissolved oxygen concentration. It has been shown that the performance of zero valent iron coated clinoptilolite zeolite for the reduction of nitrate anion in un-buffered conditions may be enhanced by coating small amounts of Cu0 onto the freshly prepared Fe0/zeolite composite. An optimum loading of Cu0 exists for which the rate of nitrate removal is maximal. For this optimal composition, the nitrite anion production curve with time passes through a maximum. Nitrite production, however, is slightly higher for the Cu modified zeolite. It has been shown that the nitrate removal process is only slightly dependent on the initial solution pH. In the temperature range of 20–60 °C, the process is controlled by both the liquid phase mass transfer and intrinsic reaction rate resistances. FESEM analysis of the zero valent metal/zeolite composite showed that upon the metal reduction reaction, an egg-shell distribution of zero valent metal in the zeolite agglomerate particle is produced.  相似文献   

8.
Biodegradation of toluene vapour was investigated for 168 days in a polyurethane packed biofilter inoculated with a mixed microbial population. Biofilter consisted of five square cross-section modular units each of size 0.16 m × 0.16 m × 0.20 m and filled with the polyurethane foam cubes up to a height of 0.15 m. Inlet concentration of toluene was varied from 0.04 to 2.5 g m?3 and the volumetric flow rate of toluene loaded air from 0.06 to 0.90 m3 h?1.Depending upon initial loading rates, removal efficiency ranging from 68.2 to 99.9% and elimination capacity ranging from 10.85 to 90.48 g h?1 m?3 were observed during steady state operations. More than 90% removal efficiency was observed up to an inlet loading rate of 76.3 g h?1 m?3. High carbon recovery (>90%) indicated effective biodegradation in the bed. Low variation of pH (7.2–8.8) and pressure drop (45.8–76.3 Pa) was observed. The stability of the biomass was evident from the fast response of the biofilter to shutdown and restartup.  相似文献   

9.
The present study reported a method for removal of As(III) from water solution by a novel hybrid material (Ce-HAHCl). The hybrid material was synthesized by sol–gel method and was characterized by XRD, FTIR, SEM–EDS and TGA–DTA. Batch adsorption experiments were conducted as a function of different variables like adsorbent dose, pH, contact time, agitation speed, initial concentration and temperature. The experimental studies revealed that maximum removal percentage is 98.85 at optimum condition: pH = 5.0, agitation speed = 180 rpm, temperature = 60 °C and contact time = 80 min using 9 g L−1 of adsorbent dose for initial As(III) concentration of 10 mg L−1. Using adsorbent dose of 10 g L−1, the maximum removal percentage remains same with initial As(III) concentration of 25 mg L−1 (or 50 mg L−1). The maximum adsorption capacity of the material is found to be 182.6 mg g−1. Subsequently, the experimental results are used for developing a valid model based on back propagation (BP) learning algorithm with artificial neural networking (BP-ANN) for prediction of removal efficiency. The adequacy of the model (BP-ANN) is checked by value of the absolute relative percentage error (0.293) and correlation coefficient (R2 = 0.975). Comparison of experimental and predictive model results show that the model can predict the adsorption efficiency with acceptable accuracy.  相似文献   

10.
Biological control of odor gases has gained more attention in recent years. In this study, removal performance of a vertical bio-trickling filter inoculated with bacteria and fungi was studied. Bacteria and fungi were isolated from activated sludge in a sewage treatment plant. By adopting “three step immobilization method”, the bio-trickling filter could degrade pollutant immediately once hydrogen sulfide (H2S) passed. The optimal empty bed resident time was 20 s. The optimal elimination capacity was about 60 g H2S m?3 h?1 with removal efficiency of 95%. And the maximum elimination capacity was 170 g H2S m?3 h?1. Pressure drop was ranged between 5 and 15 mm H2O per bed over the whole operation. Removal efficiency was not affected obviously after terminating nutrient supply. The bio-trickling filter could recover back after shut down H2S gaseous and liquid supplies simultaneously. Microbial community structure in the bio-trickling filter was not changed significantly.Combining bacteria and fungi would be a better choice for inoculation into a bio-trickling filter because of the quickly degradation of H2S and rapid recovery under shut-down experiment. This is the first study attempting to combine bacteria and fungi for removal of H2S in a bio-trickling filter.  相似文献   

11.
On the Metropolitan Expressway in Tokyo, a tank car exploded because it was carrying hydrogen peroxide (H2O2) in a compartment in which copper chloride (CuCl2) remained. Although the main cause of the accident was trivial, the background on the accident suggested that an induction period in the reaction led to a mistake. This report describes the experimental investigation of the catalytic ability of CuCl2, and comparing it with two other copper(II) compounds (nitrate: Cu(NO3)2; and copper sulfate: CuSO4) and three iron(III) compounds (chloride: FeCl3; nitrate: Fe(NO3)3; and sulfate: Fe2(SO4)3).The experiments were performed using a reaction calorimeter. During the experiments at 35 °C, 2×10−5 mol of copper compounds slowly reacted with H2O2 and generated a precipitate. The iron compounds allowed the hydrogen peroxide to violently decompose. A 1×10−4 mol solution of CuCl2, however, produced a violent decomposition at 35 °C. At 15 °C, a moderate heat release occurred.Based on these results, the concentration and temperature dependence of the catalytic ability of CuCl2 were postulated to contribute to the induction period observed in the accident.  相似文献   

12.
Rotating biological contactors (RBCs) for wastewater treatment began in the 1970s. Removal of organic matter has been targeted within organic loading rates of up to 120 g m−2 d−1 with an optimum at around 15 g m−2 d−1 for combined BOD and ammonia removal. Full nitrification is achievable under appropriate process conditions with oxidation rates of up to 6 g m−2 d−1 reported for municipal wastewater. The RBC process has been adapted for denitrification with reported removal rates of up to 14 g m−2 d−1 with nitrogen rich wastewaters. Different media types can be used to improve organic/nitrogen loading rates through selecting for different bacterial groups. The RBC has been applied with only limited success for enhanced biological phosphorus removal and attained up to 70% total phosphorus removal. Compared to other biofilm processes, RBCs had 35% lower energy costs than trickling filters but higher demand than wetland systems. However, the land footprint for the same treatment is lower than these alternatives. The RBC process has been used for removal of priority pollutants such as pharmaceuticals and personal care products. The RBC system has been shown to eliminate 99% of faecal coliforms and the majority of other wastewater pathogens. Novel RBC reactors include systems for energy generation such as algae, methane production and microbial fuel cells for direct current generation. Issues such as scale up remain challenging for the future application of RBC technology and topics such as phosphorus removal and denitrification still require further research. High volumetric removal rate, solids retention, low footprint, hydraulic residence times are characteristics of RBCs. The RBC is therefore an ideal candidate for hybrid processes for upgrading works maximising efficiency of existing infrastructure and minimising energy consumption for nutrient removal. This review will provide a link between disciplines and discuss recent developments in RBC research and comparison of recent process designs are provided (Section 2). The microbial features of the RBC biofilm are highlighted (Section 3) and topics such as biological nitrogen removal and priority pollutant remediation are discussed (Sections 4 Biological nutrient removal in RBCs, 5 Priority pollutant remediation in RBCs). Developments in kinetics and modelling are highlighted (Section 6) and future research themes are mentioned.  相似文献   

13.
Treatment of Methyl Orange (MO), an azo dye, synthetic wastewater by electrocoagulation with periodic reversal of the electrodes (PREC) was examined. Response Surface Methodology (RSM) was used to optimize the influence of experimental conditions for color removal (CR), energy consumption (ENC), electrode consumption (ELC) and sludge production (SP) per kg MO removed (kg(MOr)) with optimal conditions being found to be pH 7.4, solution conductivity (к) 9.4 mS cm−1, cell voltage (U) 4.4 V, current density (j) 185 mA cm−2, electrocoagulation time (T) 14 min, cycle of periodic reversal of electrodes (t) 15 s, inter-electrode distance (d) 3.5 cm and initial MO concentration of 125 mg L−1. Under these conditions, 97 ± 2% color was removed and ENC, ELC and SP were 44 ± 3 kWh kg(MOr)−1, 4.1 ± 0.2 kg(Al) kg(MOr)−1 and 17.2 ± 0.9 kg(sludge) kg(MOr)−1, respectively. With the enhanced electrochemical efficiency resulting from the periodic electrode reversal, the coefficients of increased resistance and decreased current density between the two electrodes in the PREC setup were 2.48 × 10−4 Ω cm−2 min−1 and 0.29 mA cm−2 min−1, respectively, as compared to 7.72 × 10−4 Ω cm−2 min−1 and 0.79 mA cm−2 min−1 as measured for the traditional electrocoagulation process. The rate constant of decolorization was also enhanced by 20.4% from 0.152 min−1 in the traditional electrocoagulation process to 0.183 min−1 in the PREC process. These performance characteristics indicate that the PREC approach may be more promising in terms of practical application, as a cost-effective treatment, than conventional electrocoagulation for textile dye removals.  相似文献   

14.
Biohydrogen production by dark fermentation in a series of batch tests under different environmental control conditions was evaluated to determine the optimal initial cultivation pH and temperature for a continuous-flow kinetic test to validate the kinetic model system. The waste activated sludge (WAS) from fructose-processing manufacturing was used as the model substrate for biohydrogen production. The batch experiments for biohydrogen production were conducted in a 6 l bioreactor. Fifteen batch kinetic tests were investigated when pH was controlled at 6, 7, 8 and 9 as well as the temperature was controlled at 37 °C, 45 °C and 55 °C, respectively. The experimental results indicated that the optimal operational condition for hydrogen production occurred while pH was 7 and temperature was 55 °C with the highest hydrogen production of 7.8 mmol. The optimal recovery time for hydrogen was 25 h in the batch experiments. Furthermore, the kinetic test of biohydrogen production was performed by anaerobic mixed microbial culture in the continuous-flow experiment when pH and temperature was maintained at 7 and 55 °C. Approximately 60% and 7% of substrate solution was converted into acetate and hydrogen, respectively, at the steady state. Roughly only 0.77% and 2.7% of substrate solution was converted into propionate and butyrate, respectively, at a steady-state condition. The experimental and modeling approaches presented in this study could be employed for the design of pilot-scale and full-scale anaerobic biohydrogen fermentors using food-processing waste activated sludge (WAS) as a substrate solution.  相似文献   

15.
Cationic polyelectrolyte promoted effective attachment of iron oxide nanoparticles (IONPs) onto microalgal cells through electrostatic attraction. Poly(diallyldimethylammonium chloride) (PDDA) and chitosan (ChiL), both are cationic polymer, are feasible to act as binding agent to promote rapid magnetophoretic separation of Chlorella sp. through low gradient magnetic separation (LGMS) with field gradient ▿B less than 80 T/m in real time. Cell separation efficiency up to 98% for the case of PDDA and 99% for the case of ChiL can be achieved in 6 min when 3 × 107 cells/mL Chlorella sp. are exposed to 300 mg/L surface functionalized-IONPs (SF-IONPs). Different polyelectrolytes do not give significant effect on cell separation efficiency as long as the particle attachment occurred. However, the PDDA is more preferable as the binder for all type of microalgae medium than the chitosan (ChiL) since it is not pH dependent. SF-IONPs coated with PDDA guarantee the cell separation performance for all pH range of cell medium, with 98.21 ± 0.40% at pH 8.84. On the other hand, the ChiL performance will be affected by the cell medium pH, with only 22.93 ± 31.03% biomass recovery at pH 9.25.  相似文献   

16.
In this study, recalcitrant total phenol (TPh) and organic matter removal were investigated at olive mill wastewater (OMW) in sequential Coagulation and Fenton system. This study focused on different operational parameters such as pH, H2O2, and Fe2+ dosages, and [Fe2+]/[H2O2] ratios. The optimum conditions were determined as; pH = 3; [Fe2+] = 2.5 g/L; [Fe2+]/[H2O2] = 2.5. A higher treatment efficiency was achieved at sequential Coagulation and Fenton system (COD, 65.5%) and TPh, 87.2%), compared to coagulation process (COD, 51.4%; total organic carbon (TOC), 38.6% and total nitrogen (TN) 52.1%). This study demonstrated that the Coagulation and Fenton process has a potential for efficient removal of phenolic pollutants from wastewater.  相似文献   

17.
The present study investigates the adsorption potential of Chrysanthemum indicum flower in its raw (CIF-R) and biochar (CIF-BC) form for the removal of cobalt ions from aqueous solution. The adsorbents were characterized for their surface area using BET analysis, surface morphology and elemental composition with SEM-EDAX and for the presence of functional groups by FTIR analysis. Batch adsorption experiments were carried out to evaluate the effect of process parameters, viz. pH, adsorbent dosage, initial metal ion concentration, contact time, stirring speed, presence of interfering ions and temperature on the adsorption of Co(II) ion using both the adsorbents. The optimum conditions for maximum removal of Co(II) ion was ascertained to be pH 5 for both adsorbents, adsorbent dose of 4 g/L and 3 g/L, equilibrium time of 60 min and 45 min, respectively, for CIF-R and CIF-BC. The maximum adsorption capacity of CIF-R and CIF-BC was found to be 14.84 mg/g and 45.44 mg/g, respectively, for the removal of Co(II) ion. The mechanism of adsorption was studied using different models of adsorption kinetics, isotherms and thermodynamics. It was inferred that Co(II) adsorption on both CIF-R and CIF-BC followed pseudo-second order kinetics and Langmuir isotherm model with the process being spontaneous and endothermic in nature.  相似文献   

18.
Biodegradability enhancement of landfill leachate using air stripping followed by coagulation/ultrafiltration (UF) processes was introduced. The air stripping process obtained a removal efficiency of 88.6% for ammonia nitrogen (NH4–N) at air-to-liquid ratio of 3500 (pH 11) for stripping 18 h. The single coagulation process increased BOD/COD ratio by 0.089 with the FeCl3 dosage of 570 mg l?1 at pH 7.0, and the single UF process increased the BOD/COD ratio to 0.311 from 0.049. However, the combined process of coagulation/UF increased the BOD/COD ratio from 0.049 to 0.43, and the final biological oxygen demand (BOD), chemical oxygen demand (COD), NH4–N and colour of leachate were 1223.6 mg l?1, 2845.5 mg l?1, 145.1 mg l?1 and 2056.8, respectively, when 3 kDa molecular weight cut-off (MWCO) membrane was used at the operating pressure 0.7 MPa. In ultrafiltration process, the average solution flux (JV), concentration multiple (MC) and retention rate (R) for COD was 107.3 l m?2 h?1, 6.3% and 84.2%, respectively.  相似文献   

19.
Produced water is a significant waste stream generated in association with oil and gas production. It contains high concentrations of hydrocarbon constituents and different salts. In this study, a membrane sequencing batch reactor (MSBR) was used to treat synthetic and real produced water. The MSBR was evaluated in terms of biodegradation of hydrocarbons in the synthetic produced water with various organic loading rates (OLR) (0.281, 0.563, 1.124, 2.248, and 3.372 kg COD/(m3 day)), cycle time (12, 24, and 48 h), and membrane performance. The effects of salt concentrations at different total dissolved solids (TDS) (35,000, 50,000, 100,000, 150,000, 200,000, and 250,000 mg/L) on biological treatment of the pollutants in the synthetic and real wastewater were studied. At an OLR of 1.124 kg COD/(m3 day), an HRT of 48 h and TDS of 35,000 mg/L, removal efficiencies of 97.5%, 97.2%, and 98.9% of COD, total organic carbon (TOC), and oil and grease (O&G), respectively were achieved. For the real produced water, removal rates of 86.2%, 90.8%, and 90% were obtained for the same conditions. However, with increasing salt content, the COD-removal efficiencies of the synthetic and real produced water were reduced to 90.4% and 17.7%, respectively at the highest TDS.  相似文献   

20.
In the Ag(II)/Ag(I) redox mediator integrated scrubber system, NO reacts with the Ag(II) ions produced by the electrochemical oxidation of Ag(I) in an electrochemical cell present in the scrubbing solution (aqueous HNO3 acid) to form NO2. This NO2 is then absorbed into the scrubbing solution and degraded to nitrate. Numerous experimental runs were carried out to evaluate the feasibility of the integrated system to treat industrial waste gases containing high NOx levels. The results showed that the levels of NO and NOx removal increased with increasing Ag(II) loading and contact time. Under optimized conditions, 93.5% and 73.3% of the NO and NOx, respectively, were removed by a single stage gas scrubber with 1.62 g L?1 Ag(II) operating at 25 °C and atmospheric pressure.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号