首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 765 毫秒
1.
Adsorbable organic halides (AOX) and AOX formation potential (AOXFP) were investigated in 46 landfill lea-chates as potentially toxic parameters. AOX in landfill leachate was within the range <10–2200 μg Cl/l, and AOXFP was within 51–15 000 μg Cl/l. AOX and AOXFP correlated with chemical oxygen demand (COD). AOX discharge from closed landfills was generally lower than that from operating landfills. The molar ratio of AOXFP/total organic carbon (TOC) suggested that organic compounds in a leachate have a double bond every 15–190 carbons under the supposition that one chlorine would add to one double bond. The five landfills discharging high-level AOXFP (>4000 μg Cl/l) were all landfills where sludge had been dumped. The removal efficiencies of three parameters through leachate treatment processes were as follows: polychlorinated dibenzo-dioxins/dibenzo-furans (PCDDs/DFs) > TOC > AOX. PCDDs/DFs were substantially removed at p.p.t. levels, while AOX was hardly removed at relatively low levels. Received: February 14, 2000 / Accepted: January 9, 2001  相似文献   

2.
Large amounts of construction materials will be needed in Europe in anticipation for capping landfills that will be closed due to the tightening up of landfill legislation. This study was conducted to assess the potential environmental impacts of using refuse derived fuel (RDF) and municipal solid waste incineration (MSWI) ashes as substitutes for natural materials in landfill cover designs. The leaching of substances from a full-scale landfill cover test area built with different fly and bottom ashes was evaluated based on laboratory tests and field monitoring. The water that drained off above the liner (drainage) and the water that percolated through the liner into the landfill (leachate) were contaminated with Cl?, nitrogen and several trace elements (e.g., As, Cu, Mo, Ni and Se). The drainage from layers containing ash will probably require pre-treatment before discharge. The leachate quality from the ash cover is expected to have a minor influence on overall landfill leachate quality because the amounts generated from the ash covers were low, <3–30 l (m2 yr)?1. Geochemical modelling indicated that precipitation of clay minerals and other secondary compounds in the ash liner was possible within 3 years after construction, which could contribute to the retention of trace elements in the liner in the long term. Hence, from an environmental view point, the placement of ashes in layers above the liner is more critical than within the liner.  相似文献   

3.
Low-cost treatment of landfill leachate using peat   总被引:6,自引:0,他引:6  
The EU Landfill Directive obliges member states to collect and treat leachate from landfill sites. In regions of high population density, this is commonly achieved through discharge of the leachate to the municipal sewerage system. In Ireland, rural landfills can be a long distance from a suitable sewerage system, resulting in high transportation costs. On-site treatment systems, when used elsewhere, are mainly aerobic treatment systems, which are costly to construct and operate. There is a particular need for low-cost, low-maintenance leachate treatment systems for small low-income landfills, and for closed landfills, where long-term running costs of aerobic systems may be unsustainable. In 1989, this research work was initiated to investigate the use of local peat for the treatment of leachate from a small rural landfill site. In 1997, following the award of grant-aid under the EU LIFE Programme, a full-scale leachate treatment plant was constructed, using local un-drained peat as the treatment medium. When the LIFE Project ended in February 2001, leachate treatment research continued at the site using a pre-treated peat as the treatment medium. The treatment levels achieved using both types of peat are discussed in this paper. It is concluded that landfill leachate may be successfully treated using a low-cost peat bed to achieve almost 100% removal of both BOD and ammonia.  相似文献   

4.
The contribution investigates the solid waste management system in Ha Noi under consideration of the interrelation between climate change effects and landfill management by means of a cause-and-effect-analysis as well as water balances using the HELP 3.95 model and gas emission data, followed by a Strength, Weakness, Opportunities, Threats (SWOT) analysis. Even landfills are sources of methane (CH4) emissions they are also impacted by climate change. The main effects on landfill sites are the change of climatic conditions, namely the regional water balance, extreme precipitation and storm events. The results of the water balance model results show that a geomembrane surface sealing can reduce the leachate formation significantly, a fact that is also valid for the climate change scenario with higher precipitation. The risk of flooding and erosion at the landfill sites increases, which will require a customized water management. In parallel landfill gas offers the opportunity for recovery of Greenhouse Gases (GHG) and the generation of renewable energy. Some further management options are wind turbines, photovoltaic systems or biomass for biogas conversion, which was grown on closed landfill sites. The inclusion of climate friendly management options of closed landfills in a “Good Landfill Aftercare Practice” is recommended.  相似文献   

5.
This article discusses the appropriateness of using landfills as part of remediating hazardous chemical and Superfund sites, with particular emphasis on providing for true long‐term public health and environmental protection from the wastes and contaminated soils that are placed in the landfills. On‐site landfilling or capping of existing wastes is typically the least expensive approach for gaining some remediation of existing hazardous chemical/Superfund sites. The issues of the deficiencies in US EPA and state landfilling approaches discussed herein are also applicable to the landfilling of municipal and industrial solid “nonhazardous” wastes. These deficiencies were presented in part as “Problems with Landfills for Superfund Site Remediation” at the US EPA National Superfund Technical Assistance Grant Workshop held in Albuquerque, New Mexico, in February 2003. They are based on the author's experience in investigating the properties of landfill liners and the characteristics of today's landfills, relative to their ability to prevent groundwater pollution and to cause other environmental impacts. Discussed are issues related to both solid and hazardous waste landfills and approaches for improving the ability of landfills to contain wastes and monitor for leachate escape from the landfill for as long as the wastes in the landfill will be a threat. © 2004 Wiley Periodicals, Inc.  相似文献   

6.
As in all developing countries, cities in Tunisia face serious problems of environmental pollution caused mainly by the inadequate and inefficient final disposal of their generated solid wastes. The Tunisian government launched a development program including the construction of landfills in the main cities and the closure of the contaminated sites issued from solid wastes landrising practice. The project of the Henchir El Yahoudia landfill restoration is the first experience in this programme. It has been suggested to convert the site to a green park and to implement an ornamental plant nursery. The whole surface of the landfill is approximately 100 ha from which 30 ha have been already transformed to an urban recreational area and the remaining 70 ha have to be characterized for the project extension. A field investigation by boring was conducted in order to define the geological and the hydrogeological conditions, the vertical and horizontal wastes layer extension, content and degree of decomposition and the composition and quantities of leachate and landfill gas. Representative samples of waste, soil, groundwater and leachate were collected for laboratory analyses. Several of these borings were converted to piezometers to define the flow regime in the site. The results showed that the biogas (CH4, H2S, and CO2), leachate and waste, distribution in the site is mainly affected by the temporal variation of the site operating method. The underlying fissured clay layer facilitated leachate infiltration into the groundwater where high BOD, COD and nitrogen concentrations were registered.  相似文献   

7.
Leachate recirculation has been shown in lysimeter, pilot-scale and full-scale investigations to reduce the time required for waste stabilization, improve leachate quality, provide the opportunity for leachate volume reduction, and to enhance the rate of gas production. New generation full-scale landfills are implementing recirculation as a leachate management tool with increasing frequency. Leachate recirculation techniques used at full-scale landfills include pre-wetting of waste, leachate spraying, surface ponds, vertical injection wells and horizontal introduction systems. From observations of operating full-scale recirculating landfills, it appears to be important to provide flexibility in design, minimize low permeability daily and intermediate cover, include adequateex situstorage volume, control infiltration into the landfill, and utilize waste moisture holding capacity efficiently.  相似文献   

8.
Municipal solid waste (MSW) landfills are potential long-term sources of emissions. Hence, they need to be managed after closure until they do not pose a threat to humans or the environment. The case study on the Breitenau MSW landfill was performed to evaluate future emission levels for this site and to illustrate the effect of final cover installation with respect to long-term environmental risks. The methodology was based on a comprehensive assessment of the state of the landfill and included analysis of monitoring data, investigations of landfilled waste, and an evaluation of containment systems. A model to estimate future emission levels was established and site-specific predictions of leachate emissions were presented based on scenario analysis. The results are used to evaluate the future pollution potential of the landfill and to compare different aftercare concepts in view of long-term emissions. As some leachable substances became available for water flow during cover construction due to a change in the water flow pattern of the waste, a substantial increase in leachate concentrations could be observed at the site (e.g. concentrations of chloride increased from 200 to 800 mg/l and of ammonia-nitrogen from 140 to about 500 mg/l). A period of intensive flushing before the final cover installation could have reduced the amount of leachable substances within the landfill body and rapidly decreased the leachate concentrations to 11 mg Cl/l and 79 mg NH4-N/l within 50 years. Contrarily, the minimization of water infiltration is associated with leachate concentrations in a high range for centuries (above 400 mg Cl/l and 200 mg NH4-N/l) with low concomitant annual emission loads (below 12 kg/year of Cl or 9 kg/year of NH4-N, respectively). However, an expected gradual decrease of barrier efficiency over time would be associated with higher emission loads of 50 kg of chloride and 30 kg of ammonia-nitrogen at the maximum, but a faster decrease of leachate concentration levels.  相似文献   

9.
The biological conversion of sulfate from disposed gypsum drywall to hydrogen sulfide (H(2)S) in the anaerobic environment of a landfill results in odor problems and possible health concerns at many disposal facilities. To examine the extent and magnitude of such emissions, landfill gas samples from wells, soil vapor samples from the interface of the waste and cover soil, and ambient air samples, were collected from 10 construction and demolition (C&D) debris landfills in Florida and analyzed for H(2)S and other reduced sulfur compounds (RSC). H(2)S was detected in the well gas and soil vapor at all 10 sites. The concentrations in the ambient air above the surface of the landfill were much lower than those observed in the soil vapor, and no direct correlation was observed between the two sampling locations. Methyl mercaptan and carbonyl sulfide were the most frequently observed other RSC, though they occurred at smaller concentrations than H(2)S. This research confirmed the presence of H(2)S at C&D debris landfills. High concentrations of H(2)S may be a concern for employees working on the landfill site. These results indicate that workers should use proper personal protection at C&D debris landfills when involved in excavation, landfill gas collection, or confined spaces. The results indicate that H(2)S is sufficiently diluted in the atmosphere to not commonly pose acute health impacts for these landfill workers in normal working conditions. H(2)S concentrations were extremely variable with measurements occurring over a very large range (from less than 3 ppbv to 12,000 ppmv in the soil vapor and from less than 3 ppbv to 50 ppmv in ambient air). Possible reasons for the large intra- and inter-site variability observed include waste and soil heterogeneities, impact of weather conditions, and different site management practices.  相似文献   

10.
Post-closure care (PCC) activities at landfills include cap maintenance; water quality monitoring; maintenance and monitoring of the gas collection/control system, leachate collection system, groundwater monitoring wells, and surface water management system; and general site maintenance. The objective of this study was to develop an integrated data and knowledge based decision making tool for preliminary estimation of PCC needs at closed landfills. To develop the decision making tool, 11 categories of parameters were identified as critical areas which could affect future PCC needs. Each category was further analyzed by detailed questions which could be answered with limited data and knowledge about the site, its history, location, and site specific characteristics. Depending on the existing knowledge base, a score was assigned to each question (on a scale 1-10, as 1 being the best and 10 being the worst). Each category was also assigned a weight based on its relative importance on the site conditions and PCC needs. The overall landfill score was obtained from the total weighted sum attained. Based on the overall score, landfill conditions could be categorized as critical, acceptable, or good. Critical condition indicates that the landfill may be a threat to the human health and the environment and necessary steps should be taken. Acceptable condition indicates that the landfill is currently stable and the monitoring should be continued. Good condition indicates that the landfill is stable and the monitoring activities can be reduced in the future. The knowledge base algorithm was applied to two case study landfills for preliminary assessment of PCC performance.  相似文献   

11.
Landfills have been the dominant alternative for disposal of solid waste and there are tens of thousands of closed landfills throughout the world that require a long-term management strategy. In contrast to approaches based on time or target values, this paper describes a performance-based methodology for evaluation of post-closure care (PCC). Using the methodology, critical components of PCC at a landfill, including leachate and gas management, groundwater monitoring and cover integrity, are considered to determine whether a landfill meets defined conditions for functional stability and can transition from regulated PCC to a post-regulatory custodial care program representing de minimus care activities only. The methodology is predicated on understanding the biological, chemical, and physical behavior of a landfill and the presence of sufficient data to verify expected trends in landfill behavior. If an evaluation suggests that a change can be made to PCC, the landfill owner must perform confirmation monitoring and then surveillance monitoring at a decreasing frequency to verify that the change is protective of human health and the environment. A hypothetical case study showed that using the methodology to evaluate site-specific PCC requirements could result in increased environmental protection at comparable cost by spending available funds where they are most needed.  相似文献   

12.
The magnitude of annual global emissions of methane from municipal solid waste landfills without landfill gas control systems implies that these landfills are significant contributors to the atmospheric load of greenhouse gases. There have been a number of field studies undertaken internationally to measure actual fluxes of methane and carbon dioxide from landfills, with a view to corroborating modelled predictions of the contribution of landfills to the global greenhouse gas budget. The vast majority of these studies have been undertaken in more temperate climates and in developed countries. This paper reports a study of landfill gas emissions from four large landfills located in the semi-arid interior of South Africa. A static accumulation chamber was used and measurements were made at each site over a period of two to three days. The results were analysed by three different methods, all of them leading to the same general conclusion that landfill gas emission rates were lower than expected. A common conclusion based on results from all four sites was that capping of landfills in semi-arid climates with low permeability covers would probably significantly retard the already low rate of waste degradation and thus gas generation. While this may be regarded as advantageous in the short term, it cannot be relied upon in perpetuity as clayey landfill covers will inevitably desiccate and crack in a semiarid environment. In addition, reasonable after-care periods for such landfills are likely to extend well beyond the currently stipulated 30-year period, and efforts to encourage energy recovery from landfills may be hampered because gas generation rates decrease as the waste dries out under conditions of minimal recharge from precipitation. A landfill cover that allows small amounts of percolation of rainfall into the waste may therefore in fact be beneficial in semiarid climates, although care would need to be taken to carefully regulate this infiltration.  相似文献   

13.
Landfills receiving a mix of waste, including organics, have developed dramatically over the last 3-4 decades; from open dumps to engineered facilities with extensive controls on leachate and gas. The conventional municipal landfill will in most climates produce a highly contaminated leachate and a significant amount of landfill gas. Leachate controls may include bottom liners and leachate collection systems as well as leachate treatment prior to discharge to surface water. Gas controls may include oxidizing top covers, gas collection systems with flares or gas utilization systems for production of electricity and heat.The importance of leachate and gas control measures in reducing the overall environmental impact from a conventional landfill was assessed by life-cycle-assessment (LCA). The direct cost for the measures were also estimated providing a basis for assessing which measures are the most cost-effective in reducing the impact from a conventional landfill. This was done by modeling landfills ranging from a simple open dump to highly engineered conventional landfills with energy recovery in form of heat or electricity. The modeling was done in the waste LCA model EASEWASTE. The results showed drastic improvements for most impact categories. Global warming went from an impact of 0.1 person equivalent (PE) for the dump to −0.05 PE for the best design. Similar improvements were found for photochemical ozone formation (0.02 PE to 0.002 PE) and stratospheric ozone formation (0.04 PE to 0.001 PE).For the toxic and spoiled groundwater impact categories the trend is not as clear. The reason for this was that the load to the environment shifted as more technologies were used. For the dump landfill the main impacts were impacts for spoiled groundwater due to lack of leachate collection, 2.3 PE down to 0.4 PE when leachate is collected. However, at the same time, leachate collection causes a slight increase in eco-toxicity and human toxicity via water (0.007E to 0.013PE and 0.002 to 0.003 PE respectively). The reason for this is that even if the leachate is treated, slight amounts of contaminants are released through emissions of treated wastewater to surface waters.The largest environmental improvement with regard to the direct cost of the landfill was the capping and leachate treatment system. The capping, though very cheap to establish, gave a huge benefit in lowered impacts, the leachate collection system though expensive gave large benefits as well. The other gas measures were found to give further improvements, for a minor increase in cost.  相似文献   

14.
Bioreactor landfills: experimental and field results   总被引:28,自引:0,他引:28  
Bioreactor landfills allow a more active landfill management that recognizes the biological, chemical and physical processes involved in a landfill environment. This paper presents the results of an experimental study carried out to determine the effect of solid waste size, leachate recirculation and nutrient balance on the rate of municipal solid waste (MSW) biodegradation. Higher rates of MSW biodegradation eventually cause a reduction of the contaminant life span of the landfill and decrease in the cost of long term monitoring. The study indicated that the smaller the size of the MSW the faster the biodegradation rate of the waste. In addition, the paper presents the results of leachate recirculation on solid waste biodegradation in a full-scale landfill site, which is located in Nepean, Ontario, Canada. The leachate was recirculated into the landfilled solid waste for 8 years through infiltration lagoons. Similar results to those obtained in the laboratory scale experiments were noted. The average pH of the leachate in the early stages of recirculation was on the acidic range of the pH scale, however, the pH value was in the range of 7-8 after 2 years of leachate recirculation. The concentration of chloride remained fairly constant at about 1000 mg/l during the leachate recirculation period. A decreasing trend of the organic load, measured as biological oxygen demand and chemical oxygen demand, was observed. Recovery of landfill air space was also noted because of the enhanced subsidence and decomposition of the solid waste.  相似文献   

15.
Municipal solid waste landfills represent the dominant option for waste disposal in many parts of the world. While some countries have greatly reduced their reliance on landfills, there remain thousands of landfills that require aftercare. The development of cost-effective strategies for landfill aftercare is in society’s interest to protect human health and the environment and to prevent the emergence of landfills with exhausted aftercare funding. The Evaluation of Post-Closure Care (EPCC) methodology is a performance-based approach in which landfill performance is assessed in four modules including leachate, gas, groundwater, and final cover. In the methodology, the objective is to evaluate landfill performance to determine when aftercare monitoring and maintenance can be reduced or possibly eliminated. This study presents an improved gas module for the methodology. While the original version of the module focused narrowly on regulatory requirements for control of methane migration, the improved gas module also considers best available control technology for landfill gas in terms of greenhouse gas emissions, air quality, and emissions of odoriferous compounds. The improved module emphasizes the reduction or elimination of fugitive methane by considering the methane oxidation capacity of the cover system. The module also allows for the installation of biologically active covers or other features designed to enhance methane oxidation. A methane emissions model, CALMIM, was used to assist with an assessment of the methane oxidation capacity of landfill covers.  相似文献   

16.
Modern landfill understanding points out controlled operation of landfills. Emissions from landfills are caused mainly by anaerobic biodegradation processes which continue for very long time periods after landfill closure. In situ landfill stabilization aims controlled reduction of emissions towards reduced expenditures as well as aftercare measures. Since April 2010, a new in situ stabilization technique is being applied at a pilot scale landfill (BAIV) within Landfill Konstanz Dorfweiher. This new method utilizes intermittent aeration and leachate recirculation for waste stabilization. In this study, influence of this technique on leachate quality is investigated. Among many other parameters, leachate analyses were conducted for COD, BOD5, NH4–N, NO2–N, NO3–N, TKN and chloride besides continuously on site recorded pH, electrical conductivity and oxidation–reduction potential (ORP). Results from leachate quality analyses showed that biological activity in the landfill was accelerated resulting in initial higher leachate strength and reduced emission potential of landfill. During full scale in situ aeration, ambient conditions differ from optimized laboratory scale conditions which mainly concern temperature increase and deficient aeration of some landfill parts (Ritzkowski and Stegmann, 2005). Thus, as a field application results of this study have major importance on further process optimization and application.  相似文献   

17.
This paper describes a method developed for quantification of gas emissions from the leachate collection system at landfills and present emission data measured at two Danish landfills with no landfill gas collection systems in place: Fakse landfill and AV Miljø. Landfill top covers are often designed to prevent infiltration of water and thus are made from low permeable materials. At such sites a large part of the gas will often emit through other pathways such as the leachate collection system. These point releases of gaseous constituents from these locations cannot be measured using traditional flux chambers, which are often used to measure gas emissions from landfills. Comparing tracer measurements of methane (CH4) emissions from leachate systems at Fakse landfill and AV Miljø to measurements of total CH4 emissions, it was found that approximately 47% (351 kg CH4 d?1) and 27% (211 kg CH4 d?1), respectively, of the CH4 emitting from the sites occurred from the leachate collection systems. Emission rates observed from individual leachate collection wells at the two landfills ranged from 0.1 to 76 kg CH4 d?1. A strong influence on emission rates caused by rise and fall in atmospheric pressure was observed when continuously measuring emission from a leachate well over a week. Emission of CH4 was one to two orders of magnitude higher during periods of decreasing pressure compared to periods of increasing pressure.  相似文献   

18.
The presence of ammoniacal nitrogen (N-NH3) in leachate is one of the problems normally faced by landfill operators. Slow leaching of wastes producing nitrogen and no significant mechanism for transformation of N-NH3 in the landfills causes a high concentration of ammoniacal nitrogen in leachate over a long period of time. A literature review showed that the removal of ammoniacal nitrogen from leachate was not well documented and to date, there were limited studies in Malaysia on this aspect, especially in adsorption treatment. The main objective of the present study was to investigate the suitability of activated carbon, limestone and a mixture of both materials as a filtering medium, in combination with other treatments capable of attenuating ammoniacal nitrogen which is present in significant quantity (between 429 and 1909 mg L(-1)) in one of the landfill sites in Malaysia. The results of the study show that about 40% of ammoniacal nitrogen with concentration of more than 1000 mg L(-1) could be removed either by activated carbon or a mixture of carbon with limestone at mixture ratio of 5:35. This result shows that limestone is potentially useful as a cost-effective medium to replace activated carbon for ammoniacal nitrogen removal at a considerably lower cost.  相似文献   

19.
Recirculation of leachate on a covered landfill site planted with willows or other highly evapotranspirative woody plants is an inexpensive option for leachate management. In our study, a closed landfill leachate recirculation system was established on a rehabilitated municipal solid waste landfill site with planted landfill cover. The main objective of the study was to evaluate the sustainability of the system with regard to high hydraulic loads of the landfill leachate on the landfill cover and high concentrations of saline ions, especially potassium (K+), sodium (Na+) and chloride (Cl?), in leachate.The results of intensive monitoring, implemented during May 2004 and September 2007, including leachate, soil and plant samples, showed a high sustainability of the system regarding saline ions with the precipitation regime of the studied region. Saline ion concentrations in leachates varied between 132 and 2592 mg Cl? L?1, 69 and 1310 mg Na+ L?1 and between 66 and 2156 mg K+ L?1, with mean values of 1010, 632 and 686 mg L?1, respectively. Soil salinity, measured as soil electrical conductivity (EC), remained between 0.17 and 0.38 mS cm?1 at a depth between 0 and 90 cm. An average annual precipitation of 1000 mm provided sufficient leaching of saline ions, loaded by irrigation with landfill leachate, from the soil of the landfill cover and thus prevented possible salinity shocks to the planted willows.  相似文献   

20.
A probabilistic approach is presented for estimating the release of contaminants by leaching, when wastes are being considered for disposal in a class of landfills but the specific landfill disposal site is uncertain. A simple percolation and equilibrium-based release model is used in conjunction with laboratory testing results and observations of field leachate characteristics for municipal solid waste landfills, hazardous waste landfills and industrial co-disposal landfills. The approach is applied for assessing the efficacy of potential treatment processes for mercury contaminated soils. For each landfill scenario, historical values of leachate pH and annual leachate generation quantities were used to derive the probability distribution functions of the field pH and LS ratio that may be expected to contact the disposed material over an estimated time period of 100 years. For each potential treatment process, laboratory testing was used to establish the treated material's leaching characteristics as a function of pH LS ratio. This approach allowed determination of distribution frequencies and limit values for release estimates instead of single point estimates. The probability of the mass of a constituent of interest released exceeding a hypothetical threshold was examined for each treatment process and landfill system. Results of the probabilistic analysis allowed for integration of a range of data and provided a good basis for assessing the efficacy of the examined treatment processes over the three assumed disposal scenarios.  相似文献   