首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 812 毫秒
1.
A fast and simple multi-residue method for the analysis of 15 organophosphorus (OP), 17 organochlorine (OC), 8 pyrethroids (PYR), 12 N-methyl-carbamate (NMC) pesticide residues and bromopropylate in honey is presented. Ready–to–use EXtrelut®NT 20 column, eluted with dichloromethane, was used to extract the pesticide residues from the aqueous-acetone honey sample, obtaining a clean extract directly analyzable. Determination was carried out by gas chromatography (GC) coupled with flame photometric detector (FPD) for OP compounds and by GC coupled with mass spectrometry detector (MSD) for OC and PYR pesticides and bromopropylate. The NMC pesticides were analysed by liquid chromatography-double derivatization coupled with spectrofluorimetric detector (LC/DD/Fl). This method allows the determination of the 53 pesticide residues at low concentrations (0.0005–0.074 mg/kg) and can be used to assess the compliance with the Maximum Residues Levels (MRLs) set by the European Union. The performance of the method was evaluated and specificity, linearity, recovery, repeatability, reproducibility, limit of quantification (LOQ) and limit of detection (LOD) were determined. A good linearity (r2? 0.99) was found in the range 0.0005–0.074 mg/kg for the majority of the compounds studied. Most of the pesticides had recoveries in the range 70–103 % and values of relative standard deviation (RSD) < 20 for repeatability and reproducibility, showing good accuracy and precision of the method. Aldicarb partially degraded in aldicarb sulphoxide during the analytical procedure, giving anomalous values. The LOQ for all pesticides investigated was from 0.0005 to 0.025 mg/kg while the LOD ranged from 0.0002 to 0.008 mg/kg.  相似文献   

2.
Solid-phase extraction for multi-residue analysis of pesticides in honey   总被引:1,自引:0,他引:1  
A fast and simple multi-residue method for the analysis of 15 organophosphorus (OP), 17 organochlorine (OC), 8 pyrethroids (PYR), 12 N-methyl-carbamate (NMC) pesticide residues and bromopropylate in honey is presented. Ready-to-use EXtrelutNT 20 column, eluted with dichloromethane, was used to extract the pesticide residues from the aqueous-acetone honey sample, obtaining a clean extract directly analyzable. Determination was carried out by gas chromatography (GC) coupled with flame photometric detector (FPD) for OP compounds and by GC coupled with mass spectrometry detector (MSD) for OC and PYR pesticides and bromopropylate. The NMC pesticides were analysed by liquid chromatography-double derivatization coupled with spectrofluorimetric detector (LC/DD/Fl). This method allows the determination of the 53 pesticide residues at low concentrations (0.0005-0.074 mg/kg) and can be used to assess the compliance with the Maximum Residues Levels (MRLs) set by the European Union. The performance of the method was evaluated and specificity, linearity, recovery, repeatability, reproducibility, limit of quantification (LOQ) and limit of detection (LOD) were determined. A good linearity (r(2)≥ 0.99) was found in the range 0.0005-0.074 mg/kg for the majority of the compounds studied. Most of the pesticides had recoveries in the range 70-103 % and values of relative standard deviation (RSD) < 20 for repeatability and reproducibility, showing good accuracy and precision of the method. Aldicarb partially degraded in aldicarb sulphoxide during the analytical procedure, giving anomalous values. The LOQ for all pesticides investigated was from 0.0005 to 0.025 mg/kg while the LOD ranged from 0.0002 to 0.008 mg/kg.  相似文献   

3.
Tris(4-chlorophenyl)methanol (TCP) and tris(4-chlorophenyl)methane (TCPMe) were determined in aquatic organisms and sediment by a method based on Soxhlet extraction, gel permeation chromatography, fractionation over silica and gas chromatography/mass spectrometry (GC/MS) analysis. TCPMe was identified as the 4-substituted isomer after synthesis of this compound. TCP could be determined by GC/MS with negative chemical ionistation (GC/NCI-MS) with a detection limit of 0.02 g kg(-1) and a recovery of 90%. TCP concentrations in marine mammals from the North Sea and Dutch Wadden Sea ranged from 0.2 to 2 mg kg(-1), and those in marine and freshwater fish samples from 0.005 to 0.4 mg kg(-1) on a lipid wt basis. TCP concentrations in two Rhine delta sediment samples were 1.2 and 3.0 microg kg(-1) dry wt, respectively. TCPMe concentrations, determined by GC/MS with electron impact (GC/EI-MS), were 10-50% of the TCP concentration in all samples analysed.  相似文献   

4.
A low-cost, high throughput bioanalytical screening method was developed for monitoring cis/trans-permethrin in dust and soil samples. The method consisted of a simple sample preparation procedure [sonication with dichloromethane followed by a solvent exchange into methanol:water (1:1)] with bioanalytical detection using a magnetic particle enzyme-linked immunosorbent assay (ELISA). Quantitative recoveries (83–126 %) of cis/trans-permethrin were obtained for spiked soil and dust samples. The percent difference of duplicate ELISA analyses was within ± 20 % for standards and ± 35 % for samples. Similar sample preparation procedures were used for the conventional gas chromatography/mass spectrometry (GC/MS) analysis except that additional cleanup steps were required. Recoveries of cis/trans-permethrin ranged from 81 to 108 % for spiked soil and dust samples by GC/MS. The ELISA-derived permethrin concentrations were highly correlated with the GC/MS-derived sum of cis/trans-permethrin concentrations with a correlation coefficient (r) of 0.986. The ELISA method provided a rapid qualitative screen for cis/trans-permethrin in soil and dust while providing a higher sample throughput with a lower cost as compared to the GC/MS method. The ELISA can be applied as a complementary, low-cost screening tool to prioritize and rank samples prior to instrumental analysis for exposure studies.  相似文献   

5.
A fast, simple and inexpensive method has been developed for the analysis of phenoxy acid herbicides: 2,4-dichlorophenoxyacetic acid (2,4-D), 4-chloro-2-methylphenoxyacetic acid (MCPA), 2-(4-chloro-o-tolyloxy)propionic acid (MCPP), 2-(4-aryloxyphenoxy)propionic acid (Fluazifop) and 2-(4-aryloxyphenoxy)propionic acid (Haloxyfop) in carrots and apples by liquid chromatography coupled to triple quadrupole mass spectrometry (LC/MS/MS). The compounds were analyzed by QuEChERS (quick, easy, cheap, effective, rugged, safe) methodology without cleanup.

The recoveries were performed at two spiked levels (0.05 and 0.5 mg/kg) for both matrices with six replicates for each level. The mean recoveries ranged from 70–92% for both apples and carrots. The precision of the method expressed as relative standard deviation (RSD%) was found to be in the range 3–15%. For all compounds, good linearity (r2 > 0.99) was obtained over the range of concentration from 0.05 μ g/mL to 0.5 μ g/mL, corresponding to the pesticide concentrations of 0.05 mg/kg and 0.5 mg/kg, respectively. The determination limits (LOQs) ranged from 0.01 ng/mL to 1.3 ng/mL in solvent, whereas, the LOQs calculated in matrix ranged from 0.05 ng/g to 21.0 ng/g for apples and from 0.06 ng/g to 10.2 ng/g for carrots. The developed methodology combines the advantages of both QuEChERS and LC/MS/MS producing a very rapid, sensitive and cheap method useful for the routine analytical laboratories.  相似文献   

6.
Soxhlet extraction and high-performance liquid chromatography (HPLC) coupled to tandem mass spectrometry detection (MS/MS) was used for the determination of selected quaternary ammonium compounds (QACs) in solid samples. The method was applied for the determination of alkyl benzyl, dialkyl and trialkyl quaternary ammonium compounds in sediment and sludge samples in Austria. The overall method quantification limits range from 0.6 to 3 microg/kg for sediments and from 2 to 5 microg/kg for sewage sludges. Mean recoveries between 67% and 95% are achieved. In general sediments were especially contaminated by C12 chain benzalkonium chloride (BAC-C12) as well as by the long C-chain dialkyldimethylammonium chloride (DDAC-C18) with a maximum concentration of 3.6 mg/kg and 2.1mg/kg, respectively. Maxima of 27 mg/kg for DDAC-C10, 25 mg/kg for BAC-C12 and 23 mg/kg for BAC-C14 were determined for sludge samples. The sums of the 12 selected target compounds range from 22 mg/kg to 103 mg/kg in the sludge samples.  相似文献   

7.
Fenamidone is an imidazolinone fungicide recently introduced in viticulture practices. This work reports the validation and assessment of global uncertainty of a gas chromatographic with mass spectrometry method to analyze fenamidone in grapes and wines. This method consists in a simple and fast liquid-liquid extraction step followed by chromatographic determination. Limits of detection for fenamidone in grapes and wines were, respectively, 0.05 mg/kg and 0.06 mg/L, precision was below 9.4% and average recovery was 89 +/- 5%. In the concentration range from 0.05 to 1.00 mg/kg (or mg/L) of fenamidone, global uncertainty calculated following the EURACHEM/CITAC rules, and also by the Horwitz function, was below 25%. The EURACHEM/CITAC global uncertainty budget used gave lower estimates than those obtained from the Horwitz function.  相似文献   

8.
对天津市11个采样点的空气颗粒物和土壤样品进行采样调查,采用气相色谱/质谱联用仪分析样品中15种酞酸酯类化合物(PAEs)的含量。结果表明,11个采样点空气颗粒物样品中总酞酸酯类化合物(TPAEs)以体积计质量浓度为90.87~1355.70ng/m3,以质量计质量浓度为783.84~8712.37mg/kg;土壤中TPAEs质量浓度为0.53~2.53mg/kg。邻苯二甲酸二丁酯(DBP)与邻苯二甲酸二(2-乙基己基)酯(DEHP)是空气颗粒物和土壤样品中的主要污染物。土壤与空气颗粒物中TPAEs和DBP存在相关关系,Pearson相关系数分别为0.825和0.864(双尾检验,显著性水平0.01),且空气颗粒物中各种PAEs浓度为土壤PAEs浓度的数百至数万倍,说明空气沉降可能是土壤PAEs污染的主要原因之一。  相似文献   

9.
A 96-microwell enzyme-linked immunosorbent assay (ELISA) method was evaluated to determine PCDDs/PCDFs in sediment and soil samples from an EPA Superfund site. Samples were prepared and analyzed by both the ELISA and a gas chromatography/high resolution mass spectrometry (GC/HRMS) method. Comparable method precision, accuracy, and detection level (8 ng kg(-1)) were achieved by the ELISA method with respect to GC/HRMS. However, the extraction and cleanup method developed for the ELISA requires refinement for the soil type that yielded a waxy residue after sample processing. Four types of statistical analyses (Pearson correlation coefficient, paired t-test, nonparametric tests, and McNemar's test of association) were performed to determine whether the two methods produced statistically different results. The log-transformed ELISA-derived 2,3,7,8-tetrachlorodibenzo-p-dioxin values and log-transformed GC/HRMS-derived TEQ values were significantly correlated (r=0.79) at the 0.05 level. The median difference in values between ELISA and GC/HRMS was not significant at the 0.05 level. Low false negative and false positive rates (<10%) were observed for the ELISA when compared to the GC/HRMS at 1,000 ng TEQ kg(-1). The findings suggest that immunochemical technology could be a complementary monitoring tool for determining concentrations at the 1,000 ng TEQ kg(-1) action level for contaminated sediment and soil. The ELISA could also be used in an analytical triage approach to screen and rank samples prior to instrumental analysis.  相似文献   

10.
A simple and rapid method has been studied for the determination of acidic herbicides (2,4-D, Dichlorprop, Dichlorprop-p, Fluazifop, Fluroxypyr, MCPA, Mecoprop and Mecoprop-p) on cereals (rye). The method involves an alkaline hydrolysis with sodium hydroxide in order to release covalently bound compounds, prior to QuEChERS extraction, followed by neutralization and analysis via liquid chromatography-double mass spectrometry LC/MS/MS. The performance of the method either with or without alkaline hydrolysis was studied in terms of recovery rates and limit of quantification (LOQ). In either case, recoveries were determined at four spiking levels (0.02 mg/kg, 0.05 mg/kg, 0.1 mg/kg and 0.5 mg/kg) with 5 replicates for each level. Mean recoveries ranged from 90 to 120 %, whereas relative standard deviations (RSD %) proved to be less than 20 %. Quantitative analysis was carried out by the internal standard (Nicarbazin) and the LC/MS/MS analysis was performed in electrospray ionisation (ESI) negative mode using a Zorbax XCB Eclipse column. The developed method was applied to the analysis of several cereals commercially available like as rye flour, oat meal, oat flakes and dehusked oat. Residue levels were found below the limit of quantification (LOQ) of the method. The method has been tested in EU Proficiency Tests for cereals with good results.  相似文献   

11.
Rodil R  Carro AM  Lorenzo RA  Cela R 《Chemosphere》2007,67(7):1453-1462
A useful tool based on a single-step extraction and clean-up procedure for the determination of 15 organohalogenated pollutants (including brominated flame retardants) in aquaculture samples, using aluminium oxide basic and acidic silica gel in the supercritical extraction cell followed by gas chromatography with electron capture detection or mass spectrometry has been developed. This effective clean-up step ensures a minimum of chromatographic difficulties related to complex matrix components such as aquaculture feed. The extraction procedure has been screened by a fractional factorial design for the preliminary statistically significant parameters. The factors selected were extraction temperature, pressure, static extraction time, dynamic extraction time and carbon dioxide flow rate. The Doehlert design, followed by a multicriteria decision-making strategy, was then performed in order to determine the optimum conditions for the two most significant factors: pressure (165 bar) and dynamic extraction time (27 min). Under optimal conditions, the procedure developed with GC-MS/MS provides an excellent linearity, detection (0.01-0.2 ng g(-1)) and quantification limits (0.05-0.8 ng g(-1)) for most of the analytes investigated. The feasibility of the proposed supercritical fluid extraction method was validated by analysing two reference materials and fish feed and shellfish samples with satisfactory results.  相似文献   

12.
In this study, the development of a toxicity evaluation method for dioxins in human milk by enzyme-linked immunosorbent assay (ELISA) was reported. A total of 17 human milk samples were tested by ELISA and by gas chromatography/mass spectrometry (GC/MS) to assess whether the ELISA performed on samples obtained from primiparas could be considered as reliable enough for identifying a dioxins contamination in human milk. The concept of toxicity equivalent quantity (TEQ) screening was validated by comparing TEQ values for a set of human milk samples to the ELISA responses predicted for those samples. A fairly good correlation (r=0.920) between immunoassay and GC/MS was achieved for human milk. This ELISA should be useful for biological samples monitoring.  相似文献   

13.
This study tested the feasibility of using pyrolysis (Py)-gas chromatography (GC)/mass spectrometry (MS) to obtain organic chemical species data suitable for source apportionment modeling of soil-derived coarse particulate matter (PM10) dust on ambient filters. A laboratory resuspension apparatus was used with known soils to generate simulated receptor filter samples loaded with approximately 0.4 mg of PM10 dust, which is within the range of mass loading on ambient filters. Py-GC/MS at 740 degrees C generated five times more resolvable compounds than were obtained with thermal desorption GC/MS at 315 degrees C. The identified compounds were consistent with literature from Py experiments using larger samples of bulk soils. A subset of 91 organic species out of the 178 identified Py products was used as input to CMB8 software in a demonstration of source apportionment using laboratory-generated mixtures simulating ambient filter samples. The 178 quantified organic species obtained by Py of soil samples is an improvement compared with the 38 organic species obtained by thermal desorption of soils and the four functionally defined organic fractions reported by thermal/ optical reflectance. Significant differences in the concentration of specific species were seen between samples from different sites, both geographically distant and close, using analysis of variance and cluster analysis. This feasibility study showed that Py-GC/MS can generate useful source profile data for receptor modeling and justifies continued method development.  相似文献   

14.
Xie Y  Zhu Y  Xu FL  Liu X  Xue B  Tao S 《Chemosphere》2007,66(10):1878-1883
A new method was proposed to determine pyrene in mucus, which combined the synchronous fluorimetry with the multiple standard addition method (SFMSA). The method was used to determine pyrene in mucus directly without pretreatment. The method detection limit (MDL) for pyrene in mucus was measured as 0.47 ng/ml with a relative standard deviation of 12.7% (n = 7). The standard addition graph was linear in the range 0.05-50.00 ng/ml (r(2) = 0.9989). SFMSA was validated using a GC/MS method as a reference method, and nice agreement was found. The pyrene in mucus can be directly monitored by SFMSA without solvent extraction of samples. This indicates that SFMSA is more timesaving, less laborious and cheaper than the GC/MS method with solvent extraction. SFMSA has lower MDL and higher average recovery than the GC/MS method.  相似文献   

15.
A multiresidue analytical method was developed for the determination of 9 endocrine disrupting chemicals (EDCs) and 19 pharmaceuticals and personal care products (PPCPs) including acidic and neutral pharmaceuticals in water and soil samples using rapid resolution liquid chromatography-tandem mass spectrometry (RRLC-MS/MS). Solid phase extraction (SPE), and ultrasonic extraction combined with silica gel purification were applied as pretreatment methods for water and soil samples, respectively. The extracts of the EDCs and PPCPs in water and soil samples were then analyzed by RRLC-MS/MS in electrospray ionization (ESI) mode in three independent runs. The chromatographic mobile phases consisted of Milli-Q water and acetonitrile for EDCs and neutral pharmaceuticals, and Milli-Q water containing 0.01 % acetic acid (v/v) and acetonitrile: methanol (1:1, v/v) for acidic pharmaceuticals at a flow rate of 0.3 mL/min. Most of the target compounds exhibited signal suppression due to matrix effects. Measures taken to reduce matrix effects included use of isotope-labeled internal standards, and application of matrix-match calibration curves in the RRLC-MS/MS analyses. The limits of quantitation ranged between 0.15 and 14.08 ng/L for water samples and between 0.06 and 10.64 ng/g for solid samples. The recoveries for the target analytes ranged from 62 to 208 % in water samples and 43 to 177 % in solid samples, with majority of the target compounds having recoveries ranging between 70–120 %. Precision, expressed as the relative standard deviation (RSD), was obtained less than 7.6 and 20.5 % for repeatability and reproducibility, respectively. The established method was successfully applied to the water and soil samples from four irrigated plots in Guangzhou. Six compounds namely bisphenol-A, 4-nonylphenol, triclosan, triclocarban, salicylic acid and clofibric acid were detected in the soils.  相似文献   

16.
Roy S  Mysior P  Brzezinski R 《Chemosphere》2002,48(8):833-842
High resolution mass spectrometry gas chromatography (GC/MS) is the standard method for dioxin and furan analysis in environmental matrices. Considered as very accurate, this method is however time consuming and expensive. Methods based on biological interactions have the necessary sensitivity but began only recently to be investigated in the context of environmental applications. We have compared dioxin and furan toxicity levels (expressed as toxic equivalent quantities (TEQs)) in soil samples by three analytical approaches: the micro-ethoxyresorufin-o-deethylase (EROD) bioassay (a receptor-based method), an immunoassay (antibody-based method) and GC/MS analysis (used as a reference) using a shortened extraction-purification method. Both biological methods were sensitive to interferences from compounds co-extracted from samples. Most samples were underestimated by the immunoassay and, at a greater extent, overestimated by the EROD bioassay. The average accuracy of TEQ estimation (86 +/- 45% of values established by GC/MS) and the absence of false-negatives showed by the immunoassay suggest the usefulness of this method for semi-quantitative, preliminary characterization of potentially contaminated sites.  相似文献   

17.
The application of high resolution gas chromatography in combination with low resolution mass spectrometry with electron ionization and MS/MS detection (HRGC-MS/MS) is tested for its use in the analysis of PCDD/Fs in infant formulas. Development of the analytical method was based upon EPA directrices and international recommendations. Calibration linearity was tested and average relative response for any native and labelled compound over the five-point calibration range below 14% was found. The precision and accuracy of the proposed analytical procedure are also presented. Results obtained are in agreement with EPA criteria. The method is applied to the analysis of a number of initial and follow-on milk based infant formulas. In general, HRGC-MS/MS constitutes an interesting method for the analysis of dioxins in such matrices.  相似文献   

18.
The Quick, Easy, Cheap, Effective, Rugged, and Safe (QuEChERS) method was applied to the extraction of 14 organochlorine pesticides (OCPs) residues from commercial fruit pulps available in supermarkets in Fortaleza, Northeastern Brazil. The analyses were carried out by gas chromatography (GC), coupled to an electron-capture detector (ECD), and were confirmed by GC-tandem mass spectrometry (MS). The parameters of the analytical method, such as accuracy, precision, linear range, limits of detection and quantification, were determined for each pesticide. The results showed good linearity (R2 ≥ 0.9916) and the overall average recoveries were considered satisfactory obtaining values between 69 and 110%, RSD of 2–15 %, except for hexachlorobenzene (HCB) in açai, acerola and guava pulp samples. The OCPs were detected in guava (α–HCH; lindane) and soursop (α, β–HCH isomers) samples. The QuEChERS method and GC–ECD were successfully used to analyze OCPs in commercially available Brazilian fruit pulps and can be applied in routine analytical laboratories.  相似文献   

19.
A simple multi-residue method based on modified QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) approach was established for the determination of 17 organochlorine (OC), 15 organophosphorous (OP) and 7 synthetic pyrethroid (SP) pesticides in an economically important medicinal plant of India, Senna (Cassia angustifolia), by gas chromatography coupled to electron capture and flame thermionic detectors (GC/ECD/FTD) and confirmation of residues was done on gas chromatograph coupled with mass spectrometry (GC-MS). The developed method was validated by testing the following parameters: linearity, limit of detection (LOD), limit of quantification (LOQ), matrix effect, accuracy–precision and measurement uncertainty; the validation study clearly demonstrated the suitability of the method for its intended application. All pesticides showed good linearity in the range 0.01–1.0 μg mL?1 for OCs and OPs and 0.05–2.5 μg mL?1 for SPs with correlation coefficients higher than 0.98. The method gave good recoveries for most of the pesticides (70–120%) with intra-day and inter-day precision < 20% in most of the cases. The limits of detection varied from 0.003 to 0.03 mg kg?1, and the LOQs were determined as 0.01-0.049 mg kg?1. The expanded uncertainties were <30%, which was distinctively less than a maximum default value of ±50%. The proposed method was successfully applied to determine pesticide residues in 12 commercial market samples obtained from different locations in India.  相似文献   

20.
To estimate the variability of pesticide residue levels present in cauliflower units, a total of 142 samples were collected from a field trial of a cooperative farmer, and 120 samples were collected from different market places in Thessaloniki, Greece. The collected samples were extracted using the quick, easy, cheap, effective, rugged, and safe (QuEChERS) extraction technique, and the residues were determined by liquid chromatography–tandem mass spectrometry. The developed method was validated by evaluating the accuracy, precision, linearity, limit of detection (LOD), and limit of quantification (LOQ). The average recoveries for all the analytes, derived from the data of control samples fortified at 0.01, 0.05, 0.1, and 0.2 mg/kg, ranged from 74 to 110% with a relative standard deviation of ≤8%. The correlation coefficient (R2) was ≥0.997 for all the analytes using matrix-matched calibration standards. The LOD values ranged from 0.001 to 0.003 mg/kg, and the LOQ was determined at 0.01 mg/kg for all the sought analytes. The matrix effect was found to be at a considerable level, especially for cypermethrin and deltamethrin, amounting to +90% and +145%, respectively. For the field samples, the unit-to-unit variability factors (VFs) calculated for cypermethrin and deltamethrin were 2.38 and 2.32, respectively, while the average VF for the market basket samples was 5.11. In the market basket samples, residues of cypermethrin, deltamethrin, chlorpyrifos, and indoxacarb were found at levels ≥LOQ and their respective VFs were 7.12, 5.67, 5.28, and 2.40.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号