1.
Cunliffe AM  Williams PT 《Chemosphere》2007,68(9):1723-1732
The influence of temperature on the levels of PCDD and PCDF remaining in, and desorbed from, a municipal solid waste incinerator flyash was investigated by heating the ash to between 200 and 400 degrees C under a simulated flue gas for four days reaction time. Considerable desorption of PCDD/PCDF from the flyash was seen at 275 degrees C and above. Maximum desorption occurred at 350 degrees C, with the equivalent of nearly eight times the total PCDD/PCDF concentration of the original flyash being lost to the vapour phase per unit mass of initial flyash. The I-TEQ value of the desorbed PCDD/PCDF was considerable, being over fourteen times that of the original flyash at 325 degrees C. The results indicate that formation of PCDD/PCDF on flyash deposits in the post-combustion plant of incinerators can result in the release of significant amounts of PCDD/PCDF to the flue gas stream.  相似文献   

2.
Cunliffe AM  Williams PT 《Chemosphere》2007,66(6):1146-1152
A municipal solid waste incinerator flyash was heated to between 200 and 400 degrees C under nitrogen in a bench-scale, static bed reactor for 4 days soak time. The influence of temperature on the levels of PCDD and PCDF remaining in and desorbed from the ash were investigated using GC-MS/MS. PCDD and especially PCDF formation was seen on the flyash between 225 and 300 degrees C. Large increases in the I-TEQ of the treated ash relative to the increase in its overall PCDD/PCDF content indicated that the formation of 2378-substituted congeners was favoured over that of other substitution patterns. In the absence of a source of gaseous oxygen, formation was mainly attributed to de novo reactions involving solid phase oxygen. Dechlorination of the PCDD/PCDF in flyash became increasingly important above 275 degrees C. Maximum desorption was seen at 325 degrees C, with the equivalent of 35 wt% of the PCDD/F in the original flyash being recovered from the exhaust traps at this temperature. The desorbed species were mainly M(1)CDD/CDDF-T(3)CDD/CDDF resulting from dechlorination of higher chlorinated PCDD/PCDF, with consequently low I-TEQ values.  相似文献   

3.
Cunliffe AM  Williams PT 《Chemosphere》2007,66(10):1929-1938
The influence of temperature on the PCDD and PCDF isomer profiles of a municipal waste incinerator flyash and the PCDD/PCDF desorbed from the ash under an inert atmosphere was investigated using a bench-scale reactor. Exposure to temperatures of 250 degrees C and above resulted in significant changes in the distribution of isomers within most dioxin and furan congener groups. The PCDD content tended to become more evenly distributed across the range of isomers than was the case for the raw flyash, while the PCDF content became concentrated across a relatively lower number of isomers. In most cases the desorbed PCDD/PCDF were mainly mono- to tri-chlorinated, and hence had a relatively low I-TEQ value. The isomer profiles of the desorbed species were also influenced by temperature. There were some significant differences between the PCDF isomer profiles of the desorbed species and those of the treated flyashes under the same conditions, but no clear differences between the PCDD isomer profiles.  相似文献   

4.
At a MSWI (municipal solid waste incinerator) plant PCDD/PCDF samples (gasphase and particulates) were taken simultaneously be a shock-freezing method in the incinerator combustion chamber at approx. 800°C and in four sampling sections in the boiler at about 490°C, 370°C, 330°C and 270°C. In this way PCDD/PCDF-formation in the flow through the boiler was determined. Two data sets were evaluated. A considerable PCDD/PCDF-formation had occurred already at boiler temperatures of about 490°C; the highest concentration, however, was found at the end of the boiler at about 300°C. The accompanying measuring program of plant parameters made the calculation of the PCDD/PCDF mass flows possible, which allowed the inclusion of the PCDD/PCDF-content in the ESP dust in the mass flow calculations.  相似文献   

5.
H.Y. Tong  F.W. Karasek 《Chemosphere》1986,15(9-12):1219-1224
Flyash samples were collected from the electrostatic precipitators of seven municipal refuse incinerators of four different countries. Analytical results of PCDD and PCDF in these samples shows a very similar iosmer distribution pattern for all PCDD/PCDF although concentrations of PCDD and PCDF vary. These results imply that PCDD/PCDF were formed through the same mechanism in those incinerators regardless of garbage composition or incinerator design.  相似文献   

6.
Modeling the formation of PCDD/F in solid waste incinerators   总被引:1,自引:0,他引:1  
Stanmore BR 《Chemosphere》2002,47(6):565-573
Polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/F) appear in unacceptable amounts in the gaseous emissions during the incineration of wastes containing significant quantities of chlorine and metals, such as MSW and medical waste. They are formed both in the gas phase at temperatures above 600 degrees C and on the surface of the solid phase (flyash) in the temperature range 400-225 degrees C. Both the precursor (from existing smaller chlorinated molecules) and de novo (from elemental carbon) routes are involved. An empirically derived global model for their de novo formation on flyash in MSW and medical waste incinerators has now been extended to include the precursor mechanism, and a gas phase formation component, with separate rate expressions for PCDD and PCDF. Homogeneous PCDD formation is governed by the concentration of chlorophenols and PCDF by that of chlorophenols and chlorobenzenes. The result is more complete system which distinguishes between the gas and solid phase contributions to the I-TEQ. An additional step for the adsorption of gaseous PCDD/F back onto the solid phase during cooling suggests this should be minimal in the gas ducts of an incinerator. The extended model has been tested against experimental data collected from a well-controlled pilot incinerator and commercial incinerators, and found to adequately describe the measured outputs. With the model it should be possible to predict the PCDD/F emissions from commercial incinerators, provided that the ash properties and the overall temperature-time profiles are known.  相似文献   

7.
Weber R  Sakurai T  Ueno S  Nishino J 《Chemosphere》2002,49(2):127-134
The correlation of PCDD/PCDF levels with the CO emissions in a full-scale municipal waste incinerator was assessed during a four-week measurement effort. PCDD/PCDF concentrations in fly ashes-containing more than 99% of the total PCDD/PCDF burden of the fluidized bed incinerator (FBI)-were measured and compared with the emitted CO concentrations. The CO concentration during the sampling time showed no significant correlation to the PCDD/ PCDF amount in fly ash (R2 = 0.078). However, a comparison of the time integrated CO concentration several hours before sampling lead to a correlation with the PCDD/PCDF burden. Maximum correlation was found for the time integrated CO values of 3 and 4 h before sampling (R2 = 0.467 and R2 = 0.457 respectively). This indicates a memory effect in the high temperature cooling section of several hours. Possible mechanisms leading to the memory effect are discussed. The correlation of PCDD/PCDF with CO concentration demonstrate that the combustion conditions play an important role for PCDD/PCDF formation in FBIs. However the variability in the correlation of CO to PCDD/PCDF levels show that other factors have a significant influence on PCDD/PCDF formation.  相似文献   

8.
Three laboratories participated in a PCDD and PCDF sampling experiment on the stack of a municipal waste incinerator and six laboratories examined a fly ash sample for PCDDS and PCDFS in order to assess analytical precision.

The flue gas sampling results are in agreement for the three laboratories and show that the PCDDS and PCDFS are predominantly in the gas phase, whereas emitted particulate account for 20% of the total PCDD/PCDF concentration.  相似文献   


9.
Significant dioxin (polychlorinated dibenzo-para-dioxins (PCDDs)/polychlorinated dibenzo-furans (PCDFs)) pollution from a municipal solid waste incinerator was discovered in 1997 in Osaka prefecture/Japan. The cause and mechanism of pollution was identified by a detailed assessment of the environment and incinerator plant. The primary sources of PCDD/PCDF pollution were high dioxin releases from an intermittently operated waste incinerator with PCDD/PCDF emissions of 150 ng-TEQ/Nm3. PCDD/PCDF also accumulated in the wet scrubber system (3,000 μg TEQ/L) by adsorption and water recirculation in the incinerator. Scrubber water was air-cooled with a cooling tower located on the roof of the incinerator. High concentrations of dioxins in the cooling water were released as aerosols into the surrounding and caused heavy soil pollution in the area near the plant. These emissions were considered as the major contamination pathway from the plant. Decontamination and soil remediation in and around the incinerator plant were conducted using a variety of destruction technologies (including incineration, photochemical degradation and GeoMelt technology). Although the soil remediation process was successfully finished in December 2006 about 3 % of the waste still remains. The case demonstrates that releases from incinerators which do not use best available technology or which are not operated according to best environmental practices can contaminate their operators and surrounding land. This significant pollution had a large impact on the Japanese government’s approach toward controlling dioxin pollution. Since this incident, a ministerial conference on dioxins has successfully strengthened control measures.  相似文献   

10.
Gas chromatography-low resolution mass spectrometry was used to quantitate PCDD and PCDF emitted from an urban incinerator. The amounts were determinated in 17 samples collected over 9 months. Wide variability in the different sample concentrations, ranging from 2.3 mg/h to 348 mg/h for PCDD and from 3.9 mg/h to 324 mg/h for the PCDF, was observed.  相似文献   

11.
The yield of PCDD/F in relation to the presence of oxygenated PAH in model waste incinerator flyash has been investigated in a fixed bed laboratory scale reactor. Experiments were undertaken by thermal treatment of the model flyash at 250 and 350 °C under a simulated flue gas stream for 2 h. After reaction, the PCDD/F content of the reacted flyash and the PCDD/F released into the exhaust gas, and subsequently trapped by XAD-II resin in a down-stream condensation system were analyzed. The PAHs investigated were, dibenzofuran and benzo[b]naphtho[2,3-d]furan and were spiked onto the model flyash as reactant precursors for PCDD/F formation. The results showed significant formation of furans from both of the PAH investigated, however except from some highly chlorinated dioxin congeners, the formation of dioxins was not so common. Benzonaphthofuran was significantly more reactive than dibenzofuran in PCDD/F formation, in spite of the fact that dibenzofuran is structurally more similar to that of PCDD/F. Thus, there was no clear attribution between the chemical structure of PAH used and the formation of PCDD/F. There were considerable differences between the yields of PCDD/F congeners in the gaseous species and those in the reacted flyash under the same operational conditions. The concentration of PCDD/Fs was reduced at the higher reaction temperature of 350 °C; however, the higher temperature resulted in the majority of the PCDD/F formed on the flyash being released into the gas phase.  相似文献   

12.
In this paper results of various measurement campaigns at different municipal waste incineration (MWI) plants concerning the change of the PCDD/PCDF isomer distribution in the crude gas during transiently impaired combustion conditions are presented. The focus is on the Cl4DD isomer distributions exemplarily for all other homologue groups to demonstrate the change in PCDD/PCDF formation mechanism at transient combustion conditions. Additionally to crude gas samples, at one plant filter and boiler ash were investigated simultaneously to determine if there is any difference in the isomer distribution between the matrices. For the ash from an electrostatic precipitator (ESP ash), the boiler ash and the corresponding crude gas sample, nearly identical changes in the Cl4DD isomer distribution under transient combustion conditions in relation to the normal operation process could be detected. By comparing the Cl4DD isomer distributions from different incineration plants (two municipal waste incinerators and one little incinerator burning wood chips for heating domestic household) under transient combustion conditions, in all cases the 1,3,6,8- and 1,3,7,9-Cl4DD were dominating the isomer distribution, whereas under normal operation other isomers were predominant. Obviously PCDD/PCDF formation mechanisms under transient combustion conditions are independent from the type of incinerator and of the burned fuel, respectively. Data sets were analyzed with respect to the possible reaction mechanism via chlorophenols and a good correlation of 2,4,6-trichlorophenol during the second phase of a start-up process and during a CO experiment was found. To get more detailed information about possible formation mechanisms, at one plant the dependence of the PCDD/PCDF isomer distribution on the different matrices was studied. Separate analysis of fly ash collected at the boiler exit, subsequent gas phase, ESP ash and boiler ash under normal operation conditions showed that, apart from the fly ash, the Cl4DD isomer distributions are nearly the same in the different matrices. Surprisingly, the Cl4DD isomer distribution of the fly ash was more similar to the distributions found under transient combustion conditions.  相似文献   

13.
When in the vicinity of a metal reclamation plant in Tyrol, Austria, increased PCDD/PCDF levels were found in soil and spruce needles, the extent of grass contamination as well as the PCDD/PCDF content in milk of cows fed with hay from this area was determined. The milk samples showed a significant increase in PCDD/PCDF levels compared to control samples. In a blood sample of a farmer a significant increase in PCDD/PCDF levels was found. Correlations in PCDD/PCDF levels between soil, spruce needles, grass, cow's milk and human blood will be presented.  相似文献   

14.
H.Y. Tong  F.W. Karasek 《Chemosphere》1986,15(9-12):1141-1146
A complete separation of PDDD and PCDF from a complex sample matrix by a two-step HPLC clean-up procedure shows the feasibility of analysis of PCDD and PCDF using less expensive instruments. This is demonstrated by a comparison of quantitative results of PCDD and PCDF in a complex flyash sample analyzed using GC/FID, GC/ECD, and GC/MSD.  相似文献   

15.
The levels of polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) were determined in soil and vegetation samples taken from 24 sites in the vicinity of an old municipal solid waste incinerator (San Adrià del Besòs, Barcelona, Spain). Duplicate samples were collected within a radius of 3 km from the stack. PCDD/F concentrations in soils ranged from 1.22 to 34.28 ng I-TEQ/kg (d.m.) with median and mean values of 9.06 and 12.24 ng I-TEQ/kg, respectively. In turn, the levels of PCDD/Fs in vegetation samples ranged from 0.33 to 1.98 ng I-TEQ/kg (d.m.), with median and mean values of 0.58 and 0.70 ng I-TEQ/kg, respectively. Although the present PCDD/F concentrations in soil samples were higher than those recently found in soils taken near other incinerators from Catalonia, they are of the same order of magnitude than the levels of these pollutants found in incinerators from other countries. By contrast, the concentrations of PCDD/Fs in herbage samples were comparable to those found in recent surveys carried out in Catalonia.  相似文献   

16.
《Chemosphere》2012,86(11):1672-1681
The yield of PCDD/F in relation to the presence of oxygenated PAH in model waste incinerator flyash has been investigated in a fixed bed laboratory scale reactor. Experiments were undertaken by thermal treatment of the model flyash at 250 and 350 °C under a simulated flue gas stream for 2 h. After reaction, the PCDD/F content of the reacted flyash and the PCDD/F released into the exhaust gas, and subsequently trapped by XAD-II resin in a down-stream condensation system were analyzed. The PAHs investigated were, dibenzofuran and benzo[b]naphtho[2,3-d]furan and were spiked onto the model flyash as reactant precursors for PCDD/F formation. The results showed significant formation of furans from both of the PAH investigated, however except from some highly chlorinated dioxin congeners, the formation of dioxins was not so common. Benzonaphthofuran was significantly more reactive than dibenzofuran in PCDD/F formation, in spite of the fact that dibenzofuran is structurally more similar to that of PCDD/F. Thus, there was no clear attribution between the chemical structure of PAH used and the formation of PCDD/F. There were considerable differences between the yields of PCDD/F congeners in the gaseous species and those in the reacted flyash under the same operational conditions. The concentration of PCDD/Fs was reduced at the higher reaction temperature of 350 °C; however, the higher temperature resulted in the majority of the PCDD/F formed on the flyash being released into the gas phase.  相似文献   

17.
Chang MB  Chi KH  Chang-Chien GP 《Chemosphere》2004,55(11):1457-1467
Partitioning of PCDD/F congeners between gaseous and particulate phases and removal efficiencies of the air pollution control devices (APCDs) for PCDD/Fs at an existing municipal waste incinerator (MWI) in Taiwan are evaluated via stack sampling and analysis. The MWI investigated is equipped with electrostatic precipitators (EP), wet scrubbers (WS) and selective catalytic reduction system (SCR) as APCDs. The average PCDD/F concentration of stack gas is 1.49 ng/N m3, and the International Toxic Equivalent Quantity (I-TEQ) is 0.043 ng-I-TEQ/N m3. The EP increases PCDD/F concentration by 174.0% while the average removal efficiency of WS + SCR system for PCDD/Fs reaches 99.1%. In addition, the PCDF removal efficiency achieved with WS + SCR system (97.1–99.8%) is higher than that for PCDDs (96.5–99.3%). The results obtained on gas/particulate partitioning in flue gas indicate that the particulate-phase PCDD/Fs accounted for 65% at the inlet of EP, 20% at the outlet of EP and 50% at the stack, respectively, of the total PCDD/F concentrations. This study also indicates that as the chlorination level of PCDD/F congeners increases, the percentage of PCDD/Fs existing in gas phase decreases in all flue gas samples.  相似文献   

18.
In April 1996 and 1998, the concentrations of polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) were determined in 40 herbage samples collected in the neighborhood of a hazardous waste incinerator (HWI) under construction in Constanti (Catalonia, Spain). In April 2000, 20 months after the HWI began operating, herbage samples were again collected at the same sampling points in which samples had been taken in the previous surveys. PCDD/F concentrations ranged between 0.13 and 0.65 ng I-TEQ/kg (dry matter), with a median and mean values of 0.29 and 0.32 ng I-TEQ/kg (dry matter), respectively. The results were compared with those obtained in the 1996 (median, 0.53 ng I-TEQ/kg; mean, 0.61 ng I-TEQ/kg) and the 1998 (median, 0.23 ng I-TEQ/kg; mean, 0.31 ng I-TEQ/kg) surveys. While in the period 1996-1998 a significant decrease (49%, P < 0.001) in the mean PCDD/F levels was noted, in the period 1998-2000 an increase of 3% (P > 0.05) was found in the concentrations of PCDD/Fs. The analysis of the results suggests two potential hypotheses: either the emissions of PCDD/Fs from the HWI are not negligible, or the current PCDD/F emissions from other sources near the HWI remained at similar levels to those reached in 1998. Anyhow, an exhaustive evaluation of the present data shows an absence of notable PCDD/F contamination by the HWI in the area under its direct influence. It seems also probable that the decline in the atmospheric levels of PCDD/Fs due other emission sources of PCDD/Fs in this area is currently stopped.  相似文献   

19.
On-line detectable indicator parameters in the flue gas of municipal solid waste incinerators (MSWI) such as chlorinated benzenes (PCBz) are well known surrogate compounds for gas-phase PCDD/PCDF concentration. In the here presented work derivation of indicators is broadened to the detection of fly and boiler ash fractions with increased PCDD/PCDF content. Subsequently these fractions could be subject to further treatment such as recirculation in the combustion chamber to destroy their PCDD/PCDF and other organic pollutants' content. Aim of this work was to detect suitable on-line detectable indicator parameters in the gas phase, which are well correlated to PCDD/PCDF concentration in the solid residues. For this, solid residues and gas-phase samples were taken at three MSWI plants in Bavaria. Analysis of the ash content from different plants yielded a broad variation range of PCDD/PCDF concentrations especially after disturbed combustion conditions. Even during normal operation conditions significantly increased PCDD/PCDF concentrations may occur after unanticipated disturbances. Statistical evaluation of gas phase and ash measurements was carried out by means of principal component analysis, uni- and multivariate correlation analysis. Surprisingly, well known indicators for gas-phase PCDD/PCDF concentration such as polychlorinated benzenes and phenols proved to be insufficiently correlated to PCDD/PCDF content of the solid residues. Moreover, no single parameter alone was found appropriate to describe the PCDD/PCDF content of fly and boiler ashes. On the other hand, multivariate fitting of three or four parameters yielded convenient correlation coefficients of at least r=0.8 for every investigated case. Thereby, comprehension of plant operation parameters such as temperatures and air flow alongside concentrations of inorganic compounds in the gas phase (HCl, CO, SO2, NOx) gave the best results. However, the suitable set of parameters suited best for estimation of PCDD/PCDF concentration in solid residues has to be derived anew for each individual plant and type of ash.  相似文献   

20.
Chen HL  Su HJ  Liao PC  Chen CH  Lee CC 《Chemosphere》2004,54(10):1421-1429
The aim of this study was to evaluate the serum polychlorinated dibenzo-p-dioxin (PCDD) and dibenzofuran (PCDF) concentration distribution in residents living in the vicinity of an incinerator and its association with annual ambient dioxin exposure predicted by an atmospheric dispersion model. A municipal waste incinerator in Northern Taiwan was chosen for this study. This incinerator had been in operation for 6 years at the time of this study. Using the incinerator site as the center, based on the simulated ambient annual average PCDD/F concentrations. Ninety-five volunteers, all live within a radius of 5 km from the incinerator for at least 5 years, who had no occupational exposure potential, were selected based on the population distribution in each district. The average serum PCDD/F concentration for these subjects living within four zones was about 14 pg I-TEQ/g lipid. The serum distribution levels of people of the four study zones, however, were not consistent with the predicted ambient levels. Results also suggest that ambient exposure might not be the most important contributor to serum concentrations when compared to other exposure sources, such as dietary intake.  相似文献   