首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 810 毫秒
1.
Abstract

The National Oceanic and Atmospheric Administration recently sponsored the New England Forecasting Pilot Program to serve as a “test bed” for chemical forecasting by providing all of the elements of a National Air Quality Forecasting System, including the development and implementation of an evaluation protocol. This Pilot Program enlisted three regional-scale air quality models, serving as prototypes, to forecast ozone (O3) concentrations across the northeastern United States during the summer of 2002. A suite of statistical metrics was identified as part of the protocol that facilitated evaluation of both discrete forecasts (observed versus modeled concentrations) and categorical forecasts (observed versus modeled exceedances/nonexceedances) for both the maximum 1-hr (125 ppb) and 8-hr (85 ppb) forecasts produced by each of the models. Implementation of the evaluation protocol took place during a 25-day period (August 5–29), utilizing hourly O3 concentration data obtained from over 450 monitors from the U.S. Environment Protection Agency’s Air Quality System network.  相似文献   

2.
The U.S. Environmental Protection Agency in 1997 revised the 1-hr ozone (O3) National Ambient Air Quality Standard (NAAQS) to one based on an 8-hr average, resulting in potential nonattainment status for substantial portions of the eastern United States. The regulatory process provides for the development of a state implementation plan that includes a demonstration that the projected future O3 concentrations will be at or below the NAAQS based on photochemical modeling and analytical techniques. In this study, four photochemical modeling systems, based on two photochemical models, Community Model for Air Quality and the Comprehensive Air Quality Model with extensions, and two emissions processing models, Sparse Matrix Optimization Kernel for Emissions and Emissions Modeling System, were applied to the eastern United States, with emphasis on the northeastern Ozone Transport Region in terms of their response to oxides of nitrogen and volatile organic carbon-focused controls on the estimated design values. With the 8-hr O3 NAAQS set as a bright-line test, it was found that a given area could be termed as being in or out of attainment of the NAAQS depending upon the modeling system. This suggests the need to provide an estimate of model-to-model uncertainty in the relative reduction factor (RRF) for a better understanding of the uncertainty in projecting the status of an area's attainment. Results indicate that the model-to-model differences considered in this study introduce  相似文献   

3.
Abstract

The U.S. Environmental Protection Agency in 1997 revised the 1-hr ozone (O3) National Ambient Air Quality Standard (NAAQS) to one based on an 8-hr average, resulting in potential nonattainment status for substantial portions of the eastern United States. The regulatory process provides for the development of a state implementation plan that includes a demonstration that the projected future O3 concentrations will be at or below the NAAQS based on photochemical modeling and analytical techniques.

In this study, four photochemical modeling systems, based on two photochemical models, Community Model for Air Quality and the Comprehensive Air Quality Model with extensions, and two emissions processing models, Sparse Matrix Optimization Kernel for Emissions and Emissions Modeling System, were applied to the eastern United States, with emphasis on the northeastern Ozone Transport Region in terms of their response to oxides of nitrogen and volatile organic carbon-focused controls on the estimated design values. With the 8-hr O3 NAAQS set as a bright-line test, it was found that a given area could be termed as being in or out of attainment of the NAAQS depending upon the modeling system. This suggests the need to provide an estimate of model-to-model uncertainty in the relative reduction factor (RRF) for a better understanding of the uncertainty in projecting the status of an area's attainment. Results indicate that the model-to-model differences considered in this study introduce an uncertainty of the future estimated design value of ~3–5 ppb.  相似文献   

4.
The U.S. Environmental Protection Agency provides guidelines for demonstrating that future 8-hr ozone (O3) design values will be at or below the National Ambient Air Quality Standards on the basis of the application of photochemical modeling systems to simulate the effect of emission reductions. These guidelines also require assessment of the model simulation against observations. In this study, we examined the link between the simulated relative responses to emission reductions and model performance as measured by operational evaluation metrics, a part of the model evaluation required by the guidance, which often is the cornerstone of model evaluation in many practical applications. To this end, summertime O3 concentrations were simulated with two modeling systems for both 2002 and 2009 emission conditions. One of these two modeling systems was applied with two different parameterizations for vertical mixing. Comparison of the simulated base-case 8-hr daily maximum O3 concentrations showed marked model-to-model differences of up to 20 ppb, resulting in significant differences in operational model performance measures. In contrast, only relatively minor differences were detected in the relative response of O3 concentrations to emission reductions, resulting in differences of a few ppb or less in estimated future year design values. These findings imply that operational model evaluation metrics provide little insight into the reliability of the actual model application in the regulatory setting (i.e., the estimation of relative changes). In agreement with the guidance, it is argued that more emphasis should be placed on the diagnostic evaluation of O3-precursor relationships and on the development and application of dynamic and retrospective evaluation approaches in which the response of the model to changes in meteorology and emissions is compared with observed changes. As an example, simulated relative O3 changes between 1995 and 2007 are compared against observed changes. It is suggested that such retrospective studies can serve as the starting point for targeted diagnostic studies in which individual aspects of the modeling system are evaluated and refined to improve the characterization of observed changes.  相似文献   

5.
In 1997, the U.S. Environmental Protection Agency revised the National Ambient Air Quality Standard governing ozone (O3), adding an 8-hr standard of 0.08 ppm and phasing out the 1-hr requirement of 0.12 ppm. The 8-hr standard is intended to provide greater protection for human health. This research examines spatial and temporal patterns of exceedances of the standards using monitoring data and modeled estimates. The Penn State/National Center for Atmospheric Research Mesoscale Model and Models-3 framework were used to estimate hourly O3 concentrations for 4-km resolution in the Maryland/Virginia/Delaware/Washington, DC, and northern Georgia domains. Results reveal that the spatial and temporal nature of compliance is considerably different under the 8-hr standard. In the modeling simulations, the 8-hr standard was exceeded 2-5.2 times more often and in a 1.8-16.2 times larger area than the 1-hr standard. The 8-hr standard was exceeded in areas that generally comply with the 1-hr standard and are not well covered by the monitoring network. These results imply that a larger population resides in areas with unhealthy O3 levels than noncompliance with the original 1-hr standard suggests. For the MD/VA/DE/DC domains, 80 and 98% of the total population live in areas with 8-hr National Ambient Air Quality Standards (NAAQS) exceedances for the 1990 and 1995 episodes, respectively.  相似文献   

6.
Air quality impacts of volatile organic compound (VOC) and nitrogen oxide (NOx) emissions from major sources over the northwestern United States are simulated. The comprehensive nested modeling system comprises three models: Community Multiscale Air Quality (CMAQ), Weather Research and Forecasting (WRF), and Sparse Matrix Operator Kernel Emissions (SMOKE). In addition, the decoupled direct method in three dimensions (DDM-3D) is used to determine the sensitivities of pollutant concentrations to changes in precursor emissions during a severe smog episode in July of 2006. The average simulated 8-hr daily maximum O3 concentration is 48.9 ppb, with 1-hr O3 maxima up to 106 ppb (40 km southeast of Seattle). The average simulated PM2.5 (particulate matter with an aerodynamic diameter <2.5 μm) concentration at the measurement sites is 9.06 μg m?3, which is in good agreement with the observed concentration (8.06 μg m?3). In urban areas (i.e., Seattle, Vancouver, etc.), the model predicts that, on average, a reduction of NOx emissions is simulated to lead to an increase in average 8-hr daily maximum O3 concentrations, and will be most prominent in Seattle (where the greatest sensitivity is??0.2 ppb per % change of mobile sources). On the other hand, decreasing NOx emissions is simulated to decrease the 8-hr maximum O3 concentrations in remote and forested areas. Decreased NOx emissions are simulated to slightly increase PM2.5 in major urban areas. In urban areas, a decrease in VOC emissions will result in a decrease of 8-hr maximum O3 concentrations. The impact of decreased VOC emissions from biogenic, mobile, nonroad, and area sources on average 8-hr daily maximum O3 concentrations is up to 0.05 ppb decrease per % of emission change, each. Decreased emissions of VOCs decrease average PM2.5 concentrations in the entire modeling domain. In major cities, PM2.5 concentrations are more sensitive to emissions of VOCs from biogenic sources than other sources of VOCs. These results can be used to interpret the effectiveness of VOC or NOx controls over pollutant concentrations, especially for localities that may exceed National Ambient Air Quality Standards (NAAQS).

Implications: The effect of NOx and VOC controls on ozone and PM2.5 concentrations in the northwestern United States is examined using the decoupled direct method in three dimensions (DDM-3D) in a state-of-the-art three-dimensional chemical transport model (CMAQ). NOx controls are predicted to increase PM2.5 and ozone in major urban areas and decrease ozone in more remote and forested areas. VOC reductions are helpful in reducing ozone and PM2.5 concentrations in urban areas. Biogenic VOC sources have the largest impact on O3 and PM2.5 concentrations.  相似文献   

7.
A real-time air quality forecasting system (Eta-Community Multiscale Air Quality [CMAQ] model suite) has been developed by linking the National Centers for Environmental Estimation Eta model to the U.S. Environmental Protection Agency (EPA) CMAQ model. This work presents results from the application of the Eta-CMAQ modeling system for forecasting ozone (O3) over the Northeastern United States during the 2002 New England Air Quality Study (NEAQS). Spatial and temporal performance of the Eta-CMAQ model for O3 was evaluated by comparison with observations from the EPA Air Quality System (AQS) network. This study also examines the ability of the model to simulate the processes governing the distributions of tropospheric O3 on the basis of the intensive datasets obtained at the four Atmospheric Investigation, Regional Modeling, Analysis, and Estimation (AIRMAP) and Harvard Forest (HF) surface sites. The episode analysis reveals that the model captured the buildup of O3 concentrations over the northeastern domain from August 11 and reproduced the spatial distributions of observed O3 very well for the daytime (8:00 p.m.) of both August 8 and 12 with most of normalized mean bias (NMB) within +/- 20%. The model reproduced 53.3% of the observed hourly O3 within a factor of 1.5 with NMB of 29.7% and normalized mean error of 46.9% at the 342 AQS sites. The comparison of modeled and observed lidar O3 vertical profiles shows that whereas the model reproduced the observed vertical structure, it tended to overestimate at higher altitude. The model reproduced 64-77% of observed NO2 photolysis rate values within a factor of 1.5 at the AIRMAP sites. At the HF site, comparison of modeled and observed O3/nitrogen oxide (NOx) ratios suggests that the site is mainly under strongly NOx-sensitive conditions (>53%). It was found that the modeled lower limits of the O3 production efficiency values (inferred from O3-CO correlation) are close to the observations.  相似文献   

8.
To improve U.S. air quality, there are many regulations on-the-way (OTW) and on-the-books (OTB), including mobile source California Low Emission Vehicle third generation (LEV III) and federal Tier 3 standards. This study explores the effects of those regulations by using the U.S. Environmental Protection Agency's (EPA) Community Multiscale Air Quality (CMAQ) model for 8-hr ozone concentrations in the western and eastern United States in the years 2018 and 2030 during a month with typical high ozone concentrations, July. Alterations in pollutant emissions can be due to technological improvements, regulatory amendments, and changes in growth. In order to project emission rates for future years, the impacts of all of these factors were estimated. This study emphasizes the potential light-duty vehicle emission changes by year to predict ozone levels. The results of this study show that most areas have decreases in 8-hr ozone concentrations in the year 2030, although there are some areas with increased concentrations. Additionally, there are areas with 8-hr ozone concentrations greater than the current U.S. National Ambient Air Quality Standard level, which is 75 ppb.

Implications:

To improve U.S. air quality, many regulations are on the way and on the books, including mobile source California LEV III and federal Tier 3 standards. This study explores the effects of those regulations for 8-hr ozone concentrations in the western and eastern United States in the years 2018 and 2030. The results of this study show that most areas have decreases in 8-hr ozone concentrations in 2030, although there are some areas with increased concentrations. Additionally, there are areas with 8-hr ozone concentrations greater than the current U.S. National Ambient Air Quality Standard level.  相似文献   


9.
The updated regulatory framework for demonstrating that future 8-hr ozone (O3) design values will be at or below the National Ambient Air Quality Standards (NAAQS) provides guidelines for the development of a State Implementation Plan (SIP) that includes methods based on photochemical modeling and analytical techniques. One of the suggested approaches is the relative reduction factor (RRF) for estimating the efficacy of emission reductions. In this study, the sensitivity of model-predicted responses towards emission reductions to the choice of meteorology and chemical mechanisms was examined. While the different modeling simulations generally were found to be in agreement on whether predicted future-year design values would be above or below the NAAQS for 8-hr O3 at a majority of the monitoring locations in the eastern United States, differences existed for a small percentage of monitors (approximately 6.4%). Another issue investigated was the ability of the attainment demonstration procedure to predict changes in monitored O3 design values. A retrospective analysis was performed by comparing predicted O3 design values from model simulations using emission estimates for 1996 and 2001 with monitored O3 design values for 2001. Results indicated that an average gross error of approximately 5 ppb was present between modeled and observed design values and that, at approximately 27% of all sites, model-predicted and observed design values disagreed as to whether the design value was above or below the NAAQS. Retrospective analyses such as the one presented in this study can provide valuable insights into the strengths and limitations of modeling and analysis techniques used to predict future design values over time periods of a decade or more for the purpose of developing SIPs. Furthermore, such analyses could provide avenues for improvement and added confidence in the use of the RRF approach for addressing attainment of the NAAQS.  相似文献   

10.
Three modeling approaches, the U.S. Environmental Protection Agency’s (EPA) Community Multiscale Air Quality (CMAQ) zero-out, the Comprehensive Air quality Model with extensions (CAMx) zero-out, and the CAMx probing tools ozone source apportionment tool (OSAT), were used to project the contributions of various source categories to future year design values for summer 8-hr average ozone concentrations at selected U.S. monitors. The CMAQ and CAMx zero-out or brute-force approaches predicted generally similar contributions for most of the source categories, with some small differences. One of the important findings from this study was that both the CMAQ and CAMx zero-out approaches tended to apportion a larger contribution to the “other” category than the OSAT approach. For the OSAT approach, this category is the difference between the total emissions and the sum of the tracked emissions and consists of non-U.S. emissions. For the zero-out approach, it also includes the effects of nonlinearities in the system because the sum of the sensitivities of all sources is not necessarily equal to the sum of their contributions in a nonperturbed environment. The study illustrates the strengths and weaknesses of source apportionment approaches, such as OSAT, and source sensitivity approaches, such as zero-out. The OSAT approach is suitable for studying source contributions, whereas the zero-out approach is suitable for studying response to emission changes. Future year design values of summer 8-hr average ozone concentrations were projected to decrease at all the selected monitors for all the simulations in each city, except at the downtown Los Angeles monitor. Both the CMAQ and CAMx results showed all modeled locations project attainment in 2018 and 2030 to the current National Ambient Air Quality Standards (NAAQS) level of 75 ppb, except the selected Los Angeles monitor in 2018 and the selected San Bernardino monitor in 2018 and 2030.
Implications:This study illustrates the strengths and weaknesses of three modeling approaches, CMAQ zero-out, CAMx zero-out, and OSAT to project contributions of various source categories to future year design values for summer 8-hr average ozone concentrations at selected U.S. monitors. The OSAT approach is suitable for studying source contributions, whereas the zero-out approach is suitable for studying response to emission changes. Future year design values of summer 8-hr average ozone concentrations were projected to decrease, except at the downtown Los Angeles monitor. Comparing projections with the current NAAQS (75 ppb) show attainment everywhere, except two locations in 2018 and one location in 2030.  相似文献   

11.
An updated version of the Statewide Air Pollution Research Center (SAPRC) chemical mechanism (SAPRC07C) was implemented into the Community Multiscale Air Quality (CMAQ) version 4.6. CMAQ simulations using SAPRC07C and the previously released version, SAPRC99, were performed and compared for an episode during July-August, 2000. Ozone (O3) predictions of the SAPRC07C simulation are generally lower than those of the SAPRC99 simulation in the key areas of central and southern California, especially in areas where modeled concentrations are greater than the federal 8-hr O3 standard of 75 parts per billion (ppb) and/or when the volatile organic compound (VOC)/nitrogen oxides (NOx) ratio is less than 13. The relative changes of ozone production efficiency (OPE) against the VOC/NOx ratio at 46 sites indicate that the OPE is reduced in SAPRC07C compared with SAPRC99 at most sites by as much as approximately 22%. The SAPRC99 and SAPRC07C mechanisms respond similarly to 20% reductions in anthropogenic VOC emissions. The response of the mechanisms to 20% NOx emissions reductions can be grouped into three cases. In case 1, in which both mechanisms show a decrease in daily maximum 8-hr O3 concentration with decreasing NOx emissions, the O3 decrease in SAPRC07C is smaller. In case 2, in which both mechanisms show an increase in O3 with decreasing NOx emissions, the O3 increase is larger in SAPRC07C. In case 3, SAPRC07C simulates an increase in O3 in response to reduced NOx emissions whereas SAPRC99 simulates a decrease in O3 for the same region. As a result, the areas where NOx controls would be disbeneficial are spatially expanded in SAPRC07C. Although the results presented here are valuable for understanding differences in predictions and model response for SAPRC99 and SAPRC07C, the study did not evaluate the impact of mechanism differences in the context of the U.S. Environmental Protection Agency's guidance for using numerical models in demonstrating air quality attainment. Therefore, additional study is required to evaluate the full regulatory implications of upgrading air quality models to SAPRC07.  相似文献   

12.
Visibility degradation, one of the most noticeable indicators of poor air quality, can occur despite relatively low levels of particulate matter when the risk to human health is low. The availability of timely and reliable visibility forecasts can provide a more comprehensive understanding of the anticipated air quality conditions to better inform local jurisdictions and the public. This paper describes the development of a visibility forecasting modeling framework, which leverages the existing air quality and meteorological forecasts from Canada’s operational Regional Air Quality Deterministic Prediction System (RAQDPS) for the Lower Fraser Valley of British Columbia. A baseline model (GM-IMPROVE) was constructed using the revised IMPROVE algorithm based on unprocessed forecasts from the RAQDPS. Three additional prototypes (UMOS-HYB, GM-MLR, GM-RF) were also developed and assessed for forecast performance of up to 48 hr lead time during various air quality and meteorological conditions. Forecast performance was assessed by examining their ability to provide both numerical and categorical forecasts in the form of 1-hr total extinction and Visual Air Quality Ratings (VAQR), respectively. While GM-IMPROVE generally overestimated extinction more than twofold, it had skill in forecasting the relative species contribution to visibility impairment, including ammonium sulfate and ammonium nitrate. Both statistical prototypes, GM-MLR and GM-RF, performed well in forecasting 1-hr extinction during daylight hours, with correlation coefficients (R) ranging from 0.59 to 0.77. UMOS-HYB, a prototype based on postprocessed air quality forecasts without additional statistical modeling, provided reasonable forecasts during most daylight hours. In terms of categorical forecasts, the best prototype was approximately 75 to 87% correct, when forecasting for a condensed three-category VAQR. A case study, focusing on a poor visual air quality yet low Air Quality Health Index episode, illustrated that the statistical prototypes were able to provide timely and skillful visibility forecasts with lead time up to 48 hr.

Implications: This study describes the development of a visibility forecasting modeling framework, which leverages the existing air quality and meteorological forecasts from Canada’s operational Regional Air Quality Deterministic Prediction System. The main applications include tourism and recreation planning, input into air quality management programs, and educational outreach. Visibility forecasts, when supplemented with the existing air quality and health based forecasts, can assist jurisdictions to anticipate the visual air quality impacts as perceived by the public, which can potentially assist in formulating the appropriate air quality bulletins and recommendations.  相似文献   


13.
This paper provides a performance evaluation of the real-time, CONUS-scale National Air Quality Forecast Capability (NAQFC) that supported, in part, its transition into operational status. This evaluation focuses primarily on discrete forecasts for the maximum 8-h O3 concentrations covering the 4-month period, June through September, 2007, using measurements obtained from EPA's AIRNow network. Results indicate that the 2007 NAQFC performed as well or better than previous configurations, despite the expansion of the forecast domain into the western half of the nation that is dominated by complex terrain. The mean, domain-wide, season-long correlation was 0.70. When examined over time, the domain-wide correlations exhibit a fairly consistent nature, with values exceeding 0.60 (0.70) over 90% (55%) of the days. The NAQFC systematically over-predicted the 8-h O3 concentrations, continuing a trend established by earlier NAQFC configurations, though to a lesser degree. The summer-long mean forecast value of 53.2 ppb was 4.2 ppb higher than the observed value, resulting in a domain-wide Normalized Mean Bias (NMB) of 8.7%. Most of the over-prediction is associated with observed concentrations less than 50 ppb. In fact the model tends to under-predict when concentrations exceed 70 ppb. As with the bias, the error associated with the latest configuration was also lower. The summer-long Root Mean Square Error of 13.0 ppb (Normalized Mean Error (NME) = 20.4%) represented marked improvements over earlier forecasts. Examination of the spatial distribution of both the NMB and NME reveals that the NAQFC was generally within 25% for the NME and 25% for the NMB over a majority of the domain. Several areas of poorer performance, where the NMB and NME often exceed 25% and in some cases 50%, were noted. These areas include southern California, where the NAQFC tended to under-predict concentrations (especially on weekends) and the southeast Atlantic and Gulf coasts regions, where the model over-predicted. Subsequent analysis revealed that the incorrect temporal allocation of precursor emissions was likely the source of the under-prediction in southern California, while inaccurate simulation of PBL heights likely contributed to the over-prediction in the coastal regions.  相似文献   

14.
Data from the 1990 San Joaquin Valley Air Quality Study/Atmospheric Utility Signatures, Predictions, and Experiments (SJVAQS/AUSPEX) field program in California's San Joaquin Valley (SJV) suggest that both urban and rural areas would have difficulty meeting an 8-hr average O3 standard of 80 ppb. A conceptual model of O3 formation and accumulation in the SJV is formulated based on the chemical, meteorological, and tracer data from SJVAQS/AUSPEX. Two major phenomena appear to lead to high O3 concentrations in the SJV: (1) transport of O3 and precursors from upwind areas (primarily the San Francisco Bay Area, but also the Sacramento Valley) into the SJV, affecting the northern part of the valley, and (2) emissions of precursors, mixing, transport (including long-range transport), and atmospheric reactions within the SJV responsible for regional and urban-scale (e.g., down-wind of Fresno and Bakersfield) distributions of O3. Using this conceptual model, we then conduct a critical evaluation of the meteorological model and air quality model. Areas of model improvements and data needed to understand and properly simulate O3 formation in the SJV are highlighted.  相似文献   

15.
ABSTRACT

A 15-year (1981-95) climatology for the diurnal maximum ozone concentration (DMOC) was developed using 1-hr average ozone concentrations in the Baltimore-Washington area, which was made up of four regions: Baltimore, Washington, non-urban Maryland, and non-urban northern Virginia. The DMOC time series for each of these regions were divided into four terms representing different behavioral time scales: the long-term mean; the mean in-tra-annual perturbation; the interannual perturbation; and the synoptic perturbation. The urban regions had smaller values of the long-term mean ozone, but the annual range was larger. The values of the interannual perturbation were largest in the summer, when ozone production is significant, and smallest in the late winter and early spring. The interannual perturbation in the summer in the four regions consistently had positive departures in 1983, 1988, and 1991, and it had negative departures in 1981, 1984, 1985, 1989, 1990, and 1992. Summers with large positive interannual departures experienced a large number of ozone exceedances (i.e., relative to the 1-hr National Ambient Air Quality Standard of 125 parts per billion [ppb]), and summers with large negative departures experienced few or no exceedances. About 50% of the exceedances had concentrations ranging in value from 125-135 ppb, and about 75% had concentrations from 125-145 ppb.  相似文献   

16.
The prediction of spatial variation of the concentration of a pollutant governed by various sources and sinks is a complex problem. Gaussian air pollutant dispersion models such as AERMOD of the United States Environmental Protection Agency (USEPA) can be used for this purpose. AERMOD requires steady and horizontally homogeneous hourly surface and upper air meteorological observations. However, observations with such frequency are not easily available for most locations in India. To overcome this limitation, the planetary boundary layer and surface layer parameters required by AERMOD were computed using the Weather Research and Forecasting (WRF) Model (version 2.1.1) developed by the National Center for Atmospheric Research (NCAR). We have developed a preprocessor for offline coupling of WRF with AERMOD. Using this system, the dispersion of respirable particulate matter (RSPM/PM10) over Pune, India has been simulated. Data from the emissions inventory development and field-monitoring campaign (13–17 April 2005) conducted under the Pune Air Quality Management Program of the Ministry of Environment and Forests (MoEF), India and USEPA, have been used to drive and validate AERMOD. Comparison between the simulated and observed temperature and wind fields shows that WRF is capable of generating reliable meteorological inputs for AERMOD. The comparison of observed and simulated concentrations of PM10 shows that the model generally underestimates the concentrations over the city. However, data from this single case study would not be sufficient to conclude on suitability of regionally averaged meteorological parameters for driving Gaussian models like AERMOD and additional simulations with different WRF parameterizations along with an improved pollutant source data will be required for enhancing the reliability of the WRF–AERMOD modeling system.  相似文献   

17.
Taipei, the capital city of Taiwan, lies in a basin, and its topography prevents the dispersion of pollutants in the city. As a continuation of our air quality study, from February 1999 through June 1999, we measured the concentrations of SO2 at six different locations and of formaldehyde at five locations using a differential optical absorption spectrometer (DOAS). The average concentration of SO2 varied from 3.5 to 6.6 ppb. The average concentration was highest at Toucheng because of its proximity to point sources. The level in Hsientien was close to that in Toucheng, with Hsinyu showing the lowest concentrations. The DOAS and the Taiwan Air Quality Monitoring Network (TAQMN) measurements for SO2 were highly correlated (r2 > 0.9) for Toucheng, Panchiao, and Hsientien. However, DOAS SO2 concentrations were 2 times higher for Hsientien and slightly lower for Panchiao than the TAQMN concentrations were. The average concentration of formaldehyde varied from 7 to 10 ppb. Diurnal variation of formaldehyde closely followed the variation of ozone, especially when the 1-hr peak ozone concentration was > 60 ppb. Photochemical formation accounted for the ambient levels of formaldehyde in Taipei. Concentration of formaldehyde became significant on days when O3 concentration was high. Our results indicate that DOAS can replace conventional measurement techniques.  相似文献   

18.
This study comprehensively characterizes hourly fine particulate matter (PM(2.5)) concentrations measured via a tapered element oscillating microbalance (TEOM), beta-gauge, and nephelometer from four different monitoring sites in U.S. Environment Protection Agency (EPA) Region 5 (in U.S. states Illinois, Michigan, and Wisconsin) and compares them to the Federal Reference Method (FRM). Hourly characterization uses time series and autocorrelation. Hourly data are compared with FRM by averaging across 24-hr sampling periods and modeling against respective daily FRM concentrations. Modeling uses traditional two-variable linear least-squares regression as well as innovative nonlinear regression involving additional meteorological variables such as temperature and humidity. The TEOM shows a relationship with season and temperature, linear correlation as low as 0.7924 and nonlinear model correlation as high as 0.9370 when modeled with temperature. The beta-gauge shows no relationship with season or meteorological variables. It exhibits a linear correlation as low as 0.8505 with the FRM and a nonlinear model correlation as high as 0.9339 when modeled with humidity. The nephelometer shows no relationship with season or temperature but a strong relationship with humidity is observed. A linear correlation as low as 0.3050 and a nonlinear model correlation as high as 0.9508 is observed when modeled with humidity. Nonlinear models have higher correlation than linear models applied to the same dataset. This correlation difference is not always substantial, which may introduce a tradeoff between simplicity of model and degree of statistical association. This project shows that continuous monitor technology produces valid PM(2.5) characterization, with at least partial accounting for variations in concentration from gravimetric reference monitors once appropriate nonlinear adjustments are applied. Although only one regression technically meets new EPA National Ambient Air Quality Standards (NAAQS) Federal Equivalent Method (FEM) correlation coefficient criteria, several others are extremely close, showing optimistic potential for use of this nonlinear adjustment model in garnering EPA NAAQS FEM approval for continuous PM(2.5) sampling methods.  相似文献   

19.
An ozone (O3) exposure study was conducted in Nashville, TN, using passive O3 samplers to measure six weekly outdoor, indoor, and personal O3 exposure estimates for a group of 10- to 12-yr-old elementary school children. Thirty-six children from two Nashville area communities (Inglewood and Hendersonville) participated in the O3 sampling program, and 99 children provided additional time-activity information by telephone interview. By design, this study coincided with the 1994 Nashville/Middle Tennessee Ozone Study conducted by the Southern Oxidants Study, which provided enhanced continuous ambient O3 monitoring across the Nashville area. Passive sampling estimated weekly average outdoor O3 concentrations from 0.011 to 0.O30 ppm in the urban Inglewood community and from 0.015 to 0.042 ppm in suburban Hendersonville. The maximum 1- and 8-hr ambient concentrations encountered at the Hendersonville continuous monitor exceeded the levels of the 1- and 8-hr metrics for the O3 National Ambient Air Quality Standard. Weekly average personal O3 exposures ranged from 0.0013 to 0.0064 ppm (7-31% of outdoor levels). Personal O3 exposures reflected the proportional amount of time spent in indoor and outdoor environments. Air-conditioned homes displayed very low indoor O3 concentrations, and homes using open windows and fans for ventilation displayed much higher concentrations.  相似文献   

20.
The Models-3 Community Multiscale Air Quality (CMAQ) Modeling System and the Particulate Matter Comprehensive Air Quality Model with extensions (PMCAMx) were applied to simulate the period June 29-July 10, 1999, of the Southern Oxidants Study episode with two nested horizontal grid sizes: a coarse resolution of 32 km and a fine resolution of 8 km. The predicted spatial variations of ozone (O3), particulate matter with an aerodynamic diameter less than or equal to 2.5 microm (PM2.5), and particulate matter with an aerodynamic diameter less than or equal to 10 microm (PM10) by both models are similar in rural areas but differ from one another significantly over some urban/suburban areas in the eastern and southern United States, where PMCAMx tends to predict higher values of O3 and PM than CMAQ. Both models tend to predict O3 values that are higher than those observed. For observed O3 values above 60 ppb, O3 performance meets the U.S. Environmental Protection Agency's criteria for CMAQ with both grids and for PMCAMx with the fine grid only. It becomes unsatisfactory for PMCAMx and marginally satisfactory for CMAQ for observed O3 values above 40 ppb. Both models predict similar amounts of sulfate (SO4(2-)) and organic matter, and both predict SO4(2-) to be the largest contributor to PM2.5. PMCAMx generally predicts higher amounts of ammonium (NH4+), nitrate (NO3-), and black carbon (BC) than does CMAQ. PM performance for CMAQ is generally consistent with that of other PM models, whereas PMCAMx predicts higher concentrations of NO3-, NH4+, and BC than observed, which degrades its performance. For PM10 and PM2.5 predictions over the southeastern U.S. domain, the ranges of mean normalized gross errors (MNGEs) and mean normalized bias are 37-43% and -33-4% for CMAQ and 50-59% and 7-30% for PMCAMx. Both models predict the largest MNGEs for NO3- (98-104% for CMAQ 138-338% for PMCAMx). The inaccurate NO3- predictions by both models may be caused by the inaccuracies in the ammonia emission inventory and the uncertainties in the gas/particle partitioning under some conditions. In addition to these uncertainties, the significant PM overpredictions by PMCAMx may be attributed to the lack of wet removal for PM and a likely underprediction in the vertical mixing during the daytime.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号