1.
Personal 48-hr exposures of 15 randomly selected participants as well as microenvironment concentrations in each participant's residence and workplace were measured for 16 carbonyl compounds during summer-fall 1997 as a part of the Air Pollution Exposure Distributions within Adult Urban Populations in Europe (EXPOLIS) study in Helsinki, Finland. When formaldehyde and acetaldehyde were excluded, geometric mean ambient air concentrations outside each participant's residence were less than 1 ppb for all target compounds. Geometric mean residential indoor concentrations of carbonyls were systematically higher than geometric mean personal exposures and indoor workplace concentrations. Additionally, residential indoor/outdoor ratios indicated substantial indoor sources for most target compounds. Carbonyls in residential indoor air correlated significantly, suggesting similar mechanisms of entry into indoor environments. Overall, this study demonstrated the important role of non-traffic-related emissions in the personal exposures of participants in Helsinki and that comprehensive apportionment of population risk to air toxics should include exposure concentrations derived from product emissions and chemical formation in indoor air.  相似文献   

2.
Twenty-one carbonyl compounds were measured simultaneously at four hotel ballrooms in urban Guangzhou during the autumn, 2002. In each ballroom, measurements were carried out in business hours in the evening (20:30–24:00) on 7 consecutive days without any disturbance of the ballroom's normal operation. Nineteen out of the 21 target carbonyl compounds were identified in indoor and outdoor air. In the outdoor environment, formaldehyde was the most abundant carbonyl, followed by acetaldehyde, and there existed a strong correlation between formaldehyde and acetaldehyde. In the indoor air, however, acetaldehyde was the most abundant carbonyl, its concentrations seemed to be affected significantly by smoking. The indoor concentrations of carbonyls were found higher than their outdoor counterparts with only a few exceptions. Further studies concerning the indoor/outdoor ratios and mutual correlation of the carbonyls indicated that apart from direct emission from indoor materials and infiltration of outdoor air, other anthropogenic sources, e.g. tobacco smoke, also significantly contributed to carbonyl compounds. The possible sources of some high molecular weight carbonyls, e.g. nonanaldehyde, were also discussed briefly. Preliminary estimate of the exposures and risks due to carbonyls in the ballrooms was made, which indicated that long-term exposure in such places might cause increased chance of developing cancers.  相似文献   

3.
BACKGROUND, AIM AND SCOPE: All across Europe, people live and work in indoor environments. On average, people spend around 90% of their time indoors (homes, workplaces, cars and public transport means, etc.) and are exposed to a complex mixture of pollutants at concentration levels that are often several times higher than outdoors. These pollutants are emitted by different sources indoors and outdoors and include volatile organic compounds (VOCs), carbonyls (aldehydes and ketones) and other chemical substances often adsorbed on particles. Moreover, legal obligations opposed by legislations, such as the European Union's General Product Safety Directive (GPSD) and Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH), increasingly require detailed understanding of where and how chemical substances are used throughout their life-cycle and require better characterisation of their emissions and exposure. This information is essential to be able to control emissions from sources aiming at a reduction of adverse health effects. Scientifically sound human risk assessment procedures based on qualitative and quantitative human exposure information allows a better characterisation of population exposures to chemical substances. In this context, the current paper compares inhalation exposures to three health-based EU priority substances, i.e. benzene, formaldehyde and acetaldehyde. MATERIALS AND METHODS: Distributions of urban population inhalation exposures, indoor and outdoor concentrations were created on the basis of measured AIRMEX data in 12 European cities and compared to results from existing European population exposure studies published within the scientific literature. By pooling all EU city personal exposure, indoor and outdoor concentration means, representative EU city cumulative frequency distributions were created. Population exposures were modelled with a microenvironment model using the time spent and concentrations in four microenvironments, i.e. indoors at home and at work, outdoors at work and in transit, as input parameters. Pooled EU city inhalation exposures were compared to modelled population exposures. The contributions of these microenvironments to the total daily inhalation exposure of formaldehyde, benzene and acetaldehyde were estimated. Inhalation exposures were compared to the EU annual ambient benzene air quality guideline (5 microg/m3-to be met by 2010) and the recommended (based on the INDEX project) 30-min average formaldehyde limit value (30 microg/m3). RESULTS: Indoor inhalation exposure contributions are much higher compared to the outdoor or in-transit microenvironment contributions, accounting for almost 99% in the case of formaldehyde. The highest in-transit exposure contribution was found for benzene; 29.4% of the total inhalation exposure contribution. Comparing the pooled AIRMEX EU city inhalation exposures with the modelled exposures, benzene, formaldehyde and acetaldehyde exposures are 5.1, 17.3 and 11.8 microg/m3 vs. 5.1, 20.1 and 10.2 microg/m3, respectively. Together with the fact that a dominating fraction of time is spent indoors (>90%), the total inhalation exposure is mostly driven by the time spent indoors. DISCUSSION: The approach used in this paper faced three challenges concerning exposure and time-activity data, comparability and scarce or missing in-transit data inducing careful interpretation of the results. The results obtained by AIRMEX underline that many European urban populations are still exposed to elevated levels of benzene and formaldehyde in the inhaled air. It is still likely that the annual ambient benzene air quality guideline of 5 microg/m3 in the EU and recommended formaldehyde 30-min average limit value of 30 microg/m3 are exceeded by a substantial part of populations living in urban areas. Considering multimedia and multi-pathway exposure to acetaldehyde, the biggest exposure contribution was found to be related to dietary behaviour rather than to inhalation. CONCLUSIONS: In the present study, inhalation exposures of urban populations were assessed on the basis of novel and existing exposure data. The indoor residential microenvironment contributed most to the total daily urban population inhalation exposure. The results presented in this paper suggest that a significant part of the populations living in European cities exceed the annual ambient benzene air quality guideline of 5 microg/m3 in the EU and recommended (INDEX project) formaldehyde 30-min average limit value of 30 microg/m3. RECOMMENDATIONS AND PERSPECTIVES: To reduce exposures and consequent health effects, adequate measures must be taken to diminish emissions from sources such as materials and products that especially emit benzene and formaldehyde in indoor air. In parallel, measures can be taken aiming at reducing the outdoor pollution contribution indoors. Besides emission reduction, mechanisms to effectively monitor and manage the indoor air quality should be established. These mechanisms could be developed by setting up appropriate EU indoor air guidelines.  相似文献   

4.
Abstract

Personal 48-hr exposures of 15 randomly selected participants as well as microenvironment concentrations in each participant’s residence and workplace were measured for 16 carbonyl compounds during summer–fall 1997 as a part of the Air Pollution Exposure Distributions within Adult Urban Populations in Europe (EXPOLIS) study in Helsinki, Finland. When formaldehyde and acetaldehyde were excluded, geometric mean ambient air concentrations outside each participant’s residence were less than 1 ppb for all target compounds. Geometric mean residential indoor concentrations of carbonyls were systematically higher than geometric mean personal exposures and indoor workplace concentrations. Additionally, residential indoor/outdoor ratios indicated substantial indoor sources for most target compounds. Carbonyls in residential indoor air correlated significantly, suggesting similar mechanisms of entry into indoor environments. Overall, this study demonstrated the important role of non-traffic-related emissions in the personal exposures of participants in Helsinki and that comprehensive apportionment of population risk to air toxics should include exposure concentrations derived from product emissions and chemical formation in indoor air.  相似文献   

5.
Personal 48-hr exposures to formaldehyde and acetaldehyde of 15 randomly selected participants were measured during the summer/autumn of 1997 using Sep-Pak DNPH-Silica cartridges as a part of the EXPOLIS study in Helsinki, Finland. In addition to personal exposures, simultaneous measurements of microenvironmental concentrations were conducted at each participant's residence (indoor and outdoor) and workplace. Mean personal exposure levels were 21.4 ppb for formaldehyde and 7.9 ppb for acetaldehyde. Personal exposures were systematically lower than indoor residential concentrations for both compounds, and ambient air concentrations were lower than both indoor residential concentrations and personal exposure levels. Mean workplace concentrations of both compounds were lower than mean indoor residential concentrations. Correlation between personal exposures and indoor residential concentrations was statistically significant for both compounds. This indicated that indoor residential concentrations of formaldehyde and acetaldehyde are a better estimate of personal exposures than are concentrations in ambient air. In addition, a time-weighted exposure model did not improve the estimation of personal exposures above that obtained using indoor residential concentrations as a surrogate for personal exposures. Correlation between formaldehyde and acetaldehyde was statistically significant in outdoor microenvironments, suggesting that both compounds have similar sources and sinks in ambient urban air.  相似文献   

6.
Carbonyls emitted from essential oils can affect the air quality when they are used in indoors, especially under poor ventilation conditions. Lavender, lemon, rose, rosemary, and tea tree oils were selected as typical and popular essential oils to investigate in terms of composition, thermal characteristics and fifteen carbonyl constituents. Based on thermogravimetric (TG) analysis, the activation energy was 7.6–8.3 kcal mol?1, the reaction order was in the range of 0.6–0.7 and the frequency factor was 360–2838 min?1. Formaldehyde, acetaldehyde, acetone, and propionaldehyde were the dominant carbonyl compounds, and their concentrations were 0.034–0.170 ppm. The emission factors of carbonyl compounds were 2.10–3.70 mg g?1, and acetone, propionaldehyde, acetaldehyde, and formaldehyde accounted for a high portion of the emission factor of carbonyl compounds in essential oil exhaust. Some unhealthy carbonyl species such as formaldehyde and valeraldehyde, were measured at low-temperature during the vaporization of essential oils, indicating a potential effect on indoor air quality and human health.  相似文献   

7.
The characteristics of carbonyl compounds (carbonyls) including concentrations, major sources, and personal exposure were investigated for 29 vehicles including taxi, bus and subway in Beijing. It was found that the taxis (Xiali, TA) and buses (Huanghe, BA) fueled by gasoline with longer service years had the higher indoor carbonyl levels (178±42.7 and 188±31.6 μg m−3) while subways energized by electricity without exhaust and the jingwa buses (BB) driven in the suburb had the lower levels with total concentrations of 98.5±26.3 and 92.1±20.3 μg m−3, respectively. Outdoor carbonyls of taxi cars and buses were nearly at the same level with their total concentrations varying from 80 to 110 μg m−3. The level of outdoor subways carbonyls was equal with the ambient air levels. Exhaust leakage, indoor material emissions, photochemical formation, and infiltration of outdoor air were considered to be the major sources to in-vehicle carbonyls. Personal exposures and cancer risk to formaldehyde and acetaldehyde were calculated for professional bus and taxi drivers, respectively. Taxi drivers had the highest cancer risk with personal exposure to formaldehyde and acetaldehyde of 212 and 243 μg day−1, respectively. The public concern should pay considerable attention to professional drivers’ health.  相似文献   

8.
Airborne carbonyls were characterized from emitted indoor coal combustion. Samples were collected in Xuanwei (Yunnan Province), a region in China with a high rate of lung cancer. Eleven of 19 types of samples (58%) demonstrated formaldehyde concentrations higher than the World Health Organization exposure limit (a 30-min average of 100 μg m?3). Different positive significant correlations between glyoxal/methylglyoxal and formaldehyde/acetaldehyde concentrations were observed, suggesting possible different characteristics in emissions between two pairs of carbonyl compounds. A sample in the highest inhalation risk shows 29.2 times higher risk than the lowest sample, suggesting different coal sampling locations could contribute to the variation of inhalation risk. Inhabitants in Xuanwei also tend to spend more time cooking and more days per year indoors than the national average. The calculated cancer risk ranged from 2.2–63 × 10?5, which shows 13 types of samples at high-risk level. Cumulative effect in combination with different carbonyls could have contributed to the additive actual inhalation cancer risk. There is a need to explicitly address the health effects of environmentally relevant doses, considering life-long exposure in indoor dwellings.  相似文献   

9.
There is a lack of data for health risk assessment of long term personal exposure to certain ubiquitous air pollutants present particularly in urban atmospheres. The relationship between ambient background concentrations and personal exposure is often unknown. A pilot campaign to measure indoor concentrations, outdoor concentrations and personal exposure to benzene, formaldehyde and acetaldehyde was conducted in a medium sized French town. A strong contribution to total personal exposure was observed from indoor sources, especially for formaldehyde and acetaldehyde, suggesting that indoor sources are dominant for these compounds. For benzene, the average personal exposure exceeded a 10 μgm?3 limit value, although this was not the case for the ambient background concentration. For formaldehyde, the limit level was also exceeded. Observations suggest that true personal exposure cannot be determined directly from measurements pertaining from fixed ambient background monitoring stations. It is hoped that this will be taken into consideration by the bodies responsible for monitoring air pollution and the future European Air Quality Directive.  相似文献   

10.
Shin SH  Jo WK 《Chemosphere》2012,89(5):569-578
The present study investigated the indoor concentrations of selected volatile organic compounds (VOCs) and formaldehyde and their indoor emission characteristics in newly-built apartments at the pre-occupancy stage. In total, 107 apartments were surveyed for indoor and outdoor VOC concentrations in two metropolitan cities and one rural area in Korea. A mass balanced model was used to estimate surface area-specific emission rates of individual VOCs and formaldehyde. Seven (benzene, ethyl benzene, toluene, m,p-xylene, o-xylene, n-hexane, and n-heptane) of 40 target compounds were detectable in all indoor air samples, whereas the first five were detected in all outdoor air samples. Formaldehyde was also predominant in the indoor air samples, with a high detection frequency of 96%. The indoor concentrations were significantly higher than the outdoor concentrations for aromatics, alcohols, terpenes, and ketones. However, six halogenated VOCs exhibited similar concentrations for indoor and outdoor air samples, suggesting that they are not major components emitted from building materials. It was also suggested that a certain portion of the apartments surveyed were constructed by not following the Korean Ministry of Environment guidelines for formaldehyde emissions. Toluene exhibited the highest emission rate with a median value of 138 μg m−2 h−1. The target compounds with median emission rates greater than 20 μg m−2 h−1 were toluene, 1-propanol, formaldehyde, and 2-butanone. The wood panels/vinyl floor coverings were the largest indoor pollutant source, followed by floorings, wall coverings, adhesives, and paints. The wood panels/vinyl floor coverings contributed nearly three times more to indoor VOC concentrations than paints.  相似文献   

11.
The use of both oxygenated fuels in carbon monoxide (CO) nonattainment areas and reformulated gasoline in ozone nonattainment areas has been mandated by the 1990 Clean Air Act Amendments. Methanol has been proposed as an alternative fuel for CO nonattainment areas. Its use will potentially increase indoor methanol inhalation exposure resulting from the evaporation of methanol vapor from methanol-fueled vehicles parked in residential garages. Indoor air concentrations of methanol, benzene, and toluene were measured in a residential home with an attached garage. The effects of vehicle emission control devices (charcoal canister hose connection); home heating, ventilation, and air conditioning (HVAC) fans; ambient air, garage, and fuel tank temperatures; and wind speed were examined. The disconnection of the charcoal canister hose, which simulates a spent evaporative emission control device, resulted in elevated benzene, toluene, and methanol concentrations in the garage and attached home. Higher fuel tank temperatures resulted in higher benzene and toluene concentrations in the garage, but not methanol. The concentrations for all compounds in the garage and concentrations of benzene and toluene in the adjacent room were lower when the HVAC fan was on than when it was off, while the concentrations of all three compounds in the rest of the house were higher, although these differences were not statistically significant. Thus, the portion of the population that parks cars in garages attached to homes will experience increased methanol exposures if methanol is used as an automotive fuel.  相似文献   

12.
In response to community concerns, the air quality impact of imploding a 22-story building in east Baltimore, MD, was studied. Time- and space-resolved concentrations of indoor and outdoor particulate matter (PM) (nominally 0.5-10 microm) were measured using a portable nephelometer at seven and four locations, respectively. PM10 levels varied in time and space; there was no measurable effect observed upwind of the implosion. The downwind peak PM10 levels varied with distance (54,000-589 microg/m3) exceeding pre-implosion levels for sites 100 and 1130 m 3000- and 20-fold, respectively. Estimated outdoor 24-hr integrated mass concentrations varied from 15 to 72 microg/m3. The implosion did not result in the U.S. Environmental Protection Agency (EPA) National Ambient Air Quality Standard (NAAQS) for PM10 being exceeded. X-ray fluorescence analysis indicated that the elemental composition was dominated by crustal elements: calcium (57%), silicon (23%), aluminum (7.6%), and iron (6.1%). Lead was above background but at a low level (0.17 microg/m3). Peak PM10 concentrations were short-lived; most sites returned to background within 15 min. No increase in indoor PM10 was observed even at the most proximate 250 m location. These results demonstrate that a building implosion can have a severe but short-lived impact on community air quality. Effective protection is offered by being indoors or upwind.  相似文献   

13.
ABSTRACT

The use of both oxygenated fuels in carbon monoxide (CO) nonattainment areas and reformulated gasoline in ozone nonattainment areas has been mandated by the 1990 Clean Air Act Amendments. Methanol has been proposed as an alternative fuel for CO nonattainment areas. Its use will potentially increase indoor methanol inhalation exposure resulting from the evaporation of metha-nol vapor from methanol-fueled vehicles parked in residential garages. Indoor air concentrations of metha-nol, benzene, and toluene were measured in a residential home with an attached garage. The effects of vehicle emission control devices (charcoal canister hose connection); home heating, ventilation, and air conditioning (HVAC) fans; ambient air, garage, and fuel tank temperatures; and wind speed were examined.

The disconnection of the charcoal canister hose, which simulates a spent evaporative emission control device, resulted in elevated benzene, toluene, and metha-nol concentrations in the garage and attached home. Higher fuel tank temperatures resulted in higher benzene and toluene concentrations in the garage, but not methanol. The concentrations for all compounds in the garage and concentrations of benzene and toluene in the adjacent room were lower when the HVAC fan was on than when it was off, while the concentrations of all three compounds in the rest of the house were higher, although these differences were not statistically significant. Thus, the portion of the population that parks cars in garages attached to homes will experience increased methanol exposures if methanol is used as an automotive fuel.  相似文献   

14.
Indoor and outdoor carbonyl concentrations were measured simultaneously in 12 urban dwellings in Beijing, Shanghai, Guangzhou, and Xi’an, China in summer (from July to September in 2004) and winter (from December 2004 to February 2005). Formaldehyde was the most abundant indoor carbonyls species, while formaldehyde, acetaldehyde and acetone were found to be the most abundant outdoor carbonyls species. The average formaldehyde concentrations in summer indoor air varied widely between cities, ranging from a low of 19.3 μg m−3 in Xi’an to a high of 92.8 μg m−3 in Beijing. The results showed that the dwellings with tobacco smoke, incense burning or poor ventilation had significantly higher indoor concentrations of certain carbonyls. It was noticed that although one half of the dwellings in this study installed with low emission building materials or furniture, the carbonyls levels were still significantly high. It was also noted that in winter both the indoor and outdoor acetone concentrations in two dwellings in Guangzhou were significantly high, which were mainly caused by the usage of acetone as industrial solvent in many paint manufacturing and other industries located around Guangzhou and relatively longer lifetime of acetone for removal by photolysis and OH reaction than other carbonyls species. The indoor carbonyls levels in Chinese dwellings were higher than that in dwellings in the other countries. The levels of indoor and ambient carbonyls showed great seasonal differences. Six carbonyls species were carried out the estimation of indoor source strengths. Formaldehyde had the largest indoor source strength, with an average of 5.25 mg h−1 in summer and 1.98 mg h−1 in winter, respectively. However, propionaldehyde, crotonaldehyde and benzaldehyde had the weakest indoor sources.  相似文献   

15.
A comprehensive assessment of indoor carbonyl compounds for the academic staff, workers, and students was conducted on a university campus in Xiamen, China. A total of 15 representative environment categories, including 12 indoor workplaces and three residential units, were selected. The potential indoor pollution sources were identified based on the variability in the molar compositions and correlation analyses for the target carbonyls. Furnishing materials, cooking emissions, and electronic equipment, such as photocopiers, can generate various carbonyls in the workplace. Comparison studies were conducted in the clerical offices, demonstrating that off-gases from wooden furniture and lacquer coatings, environmental tobacco smoke (ETS), and the use of cleaning reagents elevated the indoor carbonyl levels. The measured concentrations of formaldehyde and acetaldehyde in most locations surpassed the exposure limit levels. The lifetime cancer hazard risk (R) associated with formaldehyde was above the concern risk level (1 × 10?6) in all of the workplaces. The results indicate that formaldehyde exposure is a valid occupational health and safety concern. Wooden furniture and refurbishing materials can pose serious health threats to occupants. The information in this study could act as a basis for future indoor air quality monitoring in Mainland China.
Implications:A university campus represents a microscale city environment consisting of all the working, living, and commercial needs of staff and students. The scope of this investigation covers 21 hazardous carbonyl species based on samples collected from 15 categories of workplaces and residential building in a university campus in southern China. Findings of the study provide a comprehensive assessment of indoor air quality with regards to workers’ health and safety. No similar study has been carried out in China.  相似文献   

16.

Background, aims, and scope

Preschool indoor air quality (IAQ) is believed to be different from elementary school or higher school IAQ and preschool is the first place for social activity. Younger children are more susceptible than higher-grade children and spend more time indoors. The purpose of this study was to compare the indoor air quality by investigating the concentrations of airborne particulates and gaseous materials at preschools in urban and rural locations in Korea.

Methods

We investigated the concentrations of airborne particulates and gaseous materials in 71 classrooms at 17 Korean preschools. For comparison, outdoor air was sampled simultaneously with indoor air samples. Airborne concentrations of total suspended particulates, respirable particulates, lead, asbestos, total volatile organic compounds and components, formaldehyde, and CO2 were measured with National Institute for Occupational Safety and Health and/or Environmental Protection Agency analytical methods.

Results

The concentration profiles of the investigated pollutants in indoor and urban settings were higher than those in outdoor and rural areas, respectively. The ratios of indoor/outdoor concentrations (I/O) of particulates and gaseous pollutants were characterized in urban and rural preschools. Total dust concentration was highest in urban indoor settings followed by urban outdoor, rural indoor, and rural outdoor locations with an I/O ratio of 1.37 in urban and 1.35 in rural areas. Although I/O ratios of lead were close to 1, lead concentrations were much higher in urban than in rural areas. The I/O ratio of total VOCs was 2.29 in urban and 2.52 in rural areas, with the highest level in urban indoor settings. The I/O ratio of formaldehyde concentrations was higher in rural than in urban areas because the outdoor rural level was much lower than the urban concentration. Since an I/O ratio higher than 1 implies the presence of indoor sources, we concluded that there are many indoor sources in preschools.

Conclusions

We confirmed that pollutants in indoor and urban settings were higher than those in outdoor and rural areas, respectively. Preschool children are expected to spend more time inside preschool facilities and therefore to be more exposed to pollutants. As far as we know, preschool IAQ is different from elementary school or higher school IAQ. Also, they are more vulnerable than higher-grade children. We found that the indoor and urban concentration profiles of the studied pollutants in preschools were higher than those in outdoor and rural areas. We believe that our findings may be useful for understanding the potential health effects of exposure and intervention studies in preschools.  相似文献   

17.
Salthammer T  Mentese S 《Chemosphere》2008,73(8):1351-1356
The level of carbonyl compounds in indoor air is crucial due to possible health effects and the high prevalence of their potential sources. Therefore, selecting a convenient and rapid analytical technique for the reliable detection of carbonyl compound concentrations is important. The acetyl acetone (acac) method is a widely used standard procedure for detecting gaseous formaldehyde. For measuring formaldehyde along with other carbonyl compounds, the DNPH-method is commonly applied. The recommended procedure for measuring volatile organic compounds (VOCs) is sampling on Tenax TA, followed by thermal desorption and GC/MS analysis. In this study, different analytical techniques for the quantification of formaldehyde, pentanal, and hexanal are critically compared. It was found that the acac- and DNPH-method are in very good agreement for formaldehyde. In contrast, the DNPH-method significantly underestimates indoor air concentrations of the higher aldehydes in comparison to sampling on Tenax TA, although both methods are strongly correlated. The reported results are part of the EURIMA-WKI study on levels of indoor air pollutants resulting from construction, building materials and interior decoration.  相似文献   

18.
Carbonyl compounds in the urban environment of Athens,Greece   总被引:6,自引:0,他引:6  
The concentration levels of 15 selected carbonyl compounds in 62 samples were determined at two sites in Athens basin from June to December 2000. Formaldehyde was the most abundant species (0.05-39 microg m(-3)), which comprised from 22% to 37% of the total measured compounds, followed by acetaldehyde (4.32-49 microg m(-3)), acetone/acrolein (0.64-198 microg m(-3)) and butanal (0.79-140 microg m(-3)). The mean formaldehyde/acetaldehyde and acetaldehyde/propanal molar ratios were calculated. No significant seasonal differences were observed for all the carbonyls. Photochemical production was found to weigh upon atmospheric levels for 83-93% in summer days, dropping below 33% in the winter. The importance of formaldehyde and acetaldehyde as a source of hydroxyl radicals in Athens was also assessed.  相似文献   

19.
The concentrations of C1–C8 carbonyl compounds were measured at two urban sites in Hong Kong from October 1997 to September 2000. The daily total carbonyl concentrations were found to range from 2.4 to 37 μg m−3. Formaldehyde was the most abundant species, which comprised from 36 to 43% of the total detected carbonyls, followed by acetaldehyde (18–21%) and acetone (8–20%). The highest 24-hour average concentrations measured were 10 and 7.7 μg m−3 for formaldehyde and acetaldehyde, respectively. Seasonal and temporal variations in the concentrations of formaldehyde and acetaldehyde were not obvious, but lowest concentrations often occurred from June to August. The mean formaldehyde/acetaldehyde molar ratios at the two sites in summer (2.8±1.1 and 2.5±1.2) were significantly higher (p⩽0.01) than those in winter periods (1.9±0.6 and 2.0±0.6). The phenomena were explained by influences of both photochemical reactions and local meteorological conditions. Better correlations between formaldehyde and acetaldehyde, and between NOx and each of the two major carbonyls were obtained in winter periods indicating direct vehicular emissions were the principal sources. The ambient formaldehyde and acetaldehyde concentrations in the urban atmosphere of Hong Kong were within the normal ranges reported in the literature for other urban sites world-wide.  相似文献   

20.
Highly portable, sensitive, and selective passive air samplers were used to investigate ambient volatile organic compound (VOC) levels at multiple sampling sites in an industrial city, Fuji, Japan. We determined the spatial distributions of 27 species of VOCs in three campaigns: Mar (cold season), May (warm season), and Nov (mild season) of 2004. In all campaigns, toluene (geometric mean concentration, 14.0microg/m3) was the most abundant VOC, followed by acetaldehyde (4.76microg/m3), and formaldehyde (2.58microg/m3). The spatial distributions for certain VOCs showed characteristic patterns: high concentrations of benzene and formaldehyde were typically found along major roads, whereas high concentrations of toluene and tetrachloroethylene (PCE) were usually found near factories. The spatial distribution of PCE observed was extremely consistent with the diffusion pattern calculated from Pollutant Release and Transfer Register data and meteorological data, indicated that passive air samplers are useful for determining the sources and distributions of ambient VOCs.  相似文献   