首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 265 毫秒
1.
Recently, we measured the concentrations of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) in soil and herbage samples collected in the vicinity of a municipal solid waste incinerator (MSWI) from Tarragona (Catalonia, Spain). Since these concentrations could be increased by the presence of other emission sources of PCDD/Fs in the same area in which the MSWI is placed, the main goal of the present study was to determine the PCDD/F congener profiles in the soil and vegetation samples collected in 1996 and again in 1997 near to the facility and to compare with those from samples collected in a close area outside of direct emissions of the plant. From an accurate inspection of the PCDD/F congener profiles, it was concluded that PCDD/F emissions from the MSWI here examined are neither the only nor the main responsible for the presence of PCDD/Fs in the samples of environmental matrices collected in the area under direct influence of the plant.  相似文献   

2.
Emission of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) by municipal solid waste incinerators (MSWI) is an issue of great concern. In 1997, an adaptation to the EU legislation on pollutant emissions from the stack was carried out in an MSWI from Tarragona (Catalonia, Spain). As a result, PCDD/F emissions were significantly reduced. The aim of this study was to determine the current levels of PCDD/Fs in soil and vegetation samples collected near the facility and to compare these levels with those obtained in previous surveys (1996 and 1997). In the period 1997-1999, PCDD/F concentrations in vegetation samples were significantly decreased (60%). By contrast, the levels of PCDD/Fs in soil samples increased slightly (14%, P > 0.05) during the same period. An exhaustive analysis of the present data indicates that other emission sources of PCDD/Fs have also a notable environmental impact on the area under direct influence of the MSWI.  相似文献   

3.
In 2005 and 2006, the levels of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), polychlorinated biphenyls (PCBs) and metals (As, Be, Cd, Co, Cr, Cu, Mn, Ni, Pb, Sn, Tl and V) were measured in air samples collected in an industrial area of Sant Adrià del Besòs (Barcelona, Catalonia, Spain) where a municipal solid waste incinerator (MSWI) is placed, and in a background/control area. In general terms, concentrations of all environmental pollutants were higher at the industrial site. No significant seasonal/temporal variations were observed in any of the areas. No Pearson correlation was found between the PCDD/F concentrations and the environmental conditions of the two sampling periods considered. Principal component analyses (PCA) were performed to get information on the relationship among samples, pollutants, and emission sources. The results indicate that the MSWI of S. Adrià de Besòs is not a significant emission source of the above compounds for the area under its direct influence. Moreover, a notable difference in the PCDD/F congener profiles was found between ambient air and stack gas emissions, indicating that the current levels of PCDD/Fs are more related to other potential emissions sources rather than to those from the MSWI.  相似文献   

4.
In April 1996 and 1998, the concentrations of polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) were determined in 40 herbage samples collected in the neighborhood of a hazardous waste incinerator (HWI) under construction in Constanti (Catalonia, Spain). In April 2000, 20 months after the HWI began operating, herbage samples were again collected at the same sampling points in which samples had been taken in the previous surveys. PCDD/F concentrations ranged between 0.13 and 0.65 ng I-TEQ/kg (dry matter), with a median and mean values of 0.29 and 0.32 ng I-TEQ/kg (dry matter), respectively. The results were compared with those obtained in the 1996 (median, 0.53 ng I-TEQ/kg; mean, 0.61 ng I-TEQ/kg) and the 1998 (median, 0.23 ng I-TEQ/kg; mean, 0.31 ng I-TEQ/kg) surveys. While in the period 1996-1998 a significant decrease (49%, P < 0.001) in the mean PCDD/F levels was noted, in the period 1998-2000 an increase of 3% (P > 0.05) was found in the concentrations of PCDD/Fs. The analysis of the results suggests two potential hypotheses: either the emissions of PCDD/Fs from the HWI are not negligible, or the current PCDD/F emissions from other sources near the HWI remained at similar levels to those reached in 1998. Anyhow, an exhaustive evaluation of the present data shows an absence of notable PCDD/F contamination by the HWI in the area under its direct influence. It seems also probable that the decline in the atmospheric levels of PCDD/Fs due other emission sources of PCDD/Fs in this area is currently stopped.  相似文献   

5.
Cheng PS  Hsu MS  Ma E  Chou U  Ling YC 《Chemosphere》2003,52(9):1389-1396
Levels of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) were determined in twenty-one ambient air samples, eight soil samples and two stack gas samples, collected near or in a municipal solid waste incinerator (MSWI) in Hsinchu, Taiwan. A systematic decrease of PCDD/Fs in the ambient air from the northeastern area was observed. PCDD/Fs levels measured in the ambient air range from 0.058 to 0.127 pg-TEQ/m3. Higher PCDD/Fs levels in the ambient air were found during winter. In addition, PCDD/Fs levels measured in the soil range from 0.524 to 5.02 pg-TEQ/g d.m. Principal component analysis (PCA) and hierarchical cluster analysis (HCA) did not provide sufficient evidence that the environmental PCDD/Fs contamination was caused by emissions from the Hsinchu MSWI. An unknown PCDD/Fs source was proposed using congener profile analysis and supported by both PCA and HCA.  相似文献   

6.
Floret N  Lucot E  Badot PM  Mauny F  Viel JF 《Chemosphere》2007,68(8):1419-1426
Since 1971, a municipal solid waste incinerator (MSWI) with high dioxin emission levels has been in operation in Besan?on, France. We recently found a 2.3-fold risk of non-Hodgkin's lymphoma in the highest exposure zone using a Gaussian-type dispersion model as a proxy for dioxin exposure. However, the sources of PCDD/Fs in this area are a matter of controversy. The aim of this survey was therefore to examine the nature of the PCDD/F soil contamination in the surroundings of the MSWI to characterize whether more than one potential emission source could explain the presence of the PCDD/Fs. PCDD/F congener profiles were determined in 75 soil samples collected in the vicinity of the MSWI. They were compared according to the most environmentally impacted zones and to various spatial contrasts. PCDD/F concentrations ranged from 0.25 to 28.06 pg WHO-TEQ g(-1). Two different clustering algorithms identified the same main cluster (consisting of 73 samples). The remaining two soil samples composed either one, or two clusters. All clusters showed similar congener profiles. Moreover, no contrast was observed for congener distributions between complex and simple topographies, inside and outside the city boundary, the two most and the two least exposed areas, reflecting a common fingerprint. Congener profiles indicate that the area under influence of the MSWI is not subject to other point sources of PCDD/Fs. Since, the most polluting combustion chambers were recently shut down and replaced by a new one with up-to-date pollution control, slowly decreasing dioxin concentrations in the soils are to be expected.  相似文献   

7.
This study was designed to evaluate soil and air (gas and particle) transfer of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) to vegetation in residential and industrial areas. In a first part, soil-vegetation transfer was assessed. The levels of PCDD/Fs in 120 soil and 120 herbage samples collected from 1996 to 2002 in an industrial area of Montcada (Barcelona, Spain), near a municipal solid waste incinerator (MSWI), were determined. Some additional individual samples were also evaluated. It was concluded that high soil concentrations, which are not at steady state with the air layer above it, show a tendency for PCDD/Fs to escape via volatilization. In a second part of the study, air-vegetation transfer was examined. PCDD/F concentrations from 24 herbage samples were used, while PCDD/F concentrations were also measured in seven high-volume air samples and seven passive air-vapor samples. Scavenging coefficients (m3 air "sampled"/g grass d.m.) ranged from 1.9 to 11.3 m3/g. A good trend with K(OA) was observed for PCDDs (R=0.82), while it was lower for PCDFs (R=0.55). The current results corroborate that PCDD/F concentrations in vegetation are associated with atmospheric deposition. For the highest substituted PCDD/F congeners, the air-particle uptake from plants is the principal pathway. In regions impacted by combustion emission sources, PCDD/F gas-particle partitioning is influenced by a higher concentration of particles in the air. Particles and associated particle-bound PCDD/Fs would sorb to leaf surfaces, and are subject to removal via wash off. However, in areas where emissions to air are not very notable, vapor absorption would be the principal source of vegetation pollution. The results of this investigation can have a potential interest in risk assessment studies and environmental fate models.  相似文献   

8.
Oh JE  Choi SD  Lee SJ  Chang YS 《Chemosphere》2006,64(4):579-587
To examine the influence of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) emissions from a municipal solid waste incinerator (MSWI) on the environment, we measured the levels of PCDD/Fs in ambient air and soil samples collected near a MSWI in Bucheon, Korea. The PCDD/Fs concentrations in the ambient air samples ranged from 0.22 to 1.16 pg I-TEQm(-3) (13.39-75.16 pg m(-3)), with an average of 0.66 pg I-TEQ m(-3) (35.62 pg m(-3)). The soil samples contained between 1.25 and 74.98 pg I-TEQ g(-1) (38.15-3,303.33 pg g(-1)), with an average of 19.06 pg I-TEQ g(-1) (1,077.11 pg g(-1)). These levels were higher than those previously reported by other investigators in a number of surveys. The furan homologues predominated in the air samples and some soil samples, and the soil PCDD/Fs levels decreased with increasing distance from the MSWI. Comparison of the homologue patterns and a multivariate statistical analysis showed that PCDD/Fs emission from the MSWI directly affected the pattern of PCDD/Fs in air, while the PCDD/Fs patterns in soil differed according to the location relative to the MSWI, roads, and construction sites. These results collectively indicate that the MSWI was the major PCDD/Fs emission source in this area, but that unidentified combustion sources and vehicles might influence the environment to some extent.  相似文献   

9.
This study aims to evaluate the influence of start-up on polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) concentration in the stack flue gas of incinerators and its contributing PCDD/F emission. The PCDD/F emission of the first sample among three consecutive stack flue gas samples of five intermittent incinerators, which sampled at a stable combustion condition after start-up, is 2-3 times higher than the mean of the others. For verifying the PCDD/F characteristics of incinerators during start-up, one continuous MSWI was investigated for two years. The elevated PCDD/F emissions of the MSWI during start-up could reach 96.9 ng I-TEQN m(-3) and still maintained a high PCDD/F emission (40 times higher than the Taiwan emission limit) even 18 h after the injection of activated carbon, indicating the memory effect. Taking the MSWI for example, which consists of four incinerators, the estimated annual PCDD/F emission from normal operational conditions was 0.112 g I-TEQ. However, one start-up procedure can generate approximately 60% of the PCDD/F emissions for one whole year of normal operations. And the PCDD/F emission, which is the result of the start-ups of four incinerators, was at least two times larger than that of a whole year's normal operations, without consideration for the PCDD/F emission contributed by the long lasting memory effect.  相似文献   

10.
Samples of soil, sediment and pine needles from the Reggio Emilia area were analysed in order to estimate the environmental pollution caused by an MSWI. PCDD/PCDF, PCB, PAH and metals were analysed in the collected samples. The data obtained showed relatively low pollution levels. Indeed, the PCDD/PCDF and PCB data were comparable to the values usually found in the grazing areas of the European Union countries. Metal concentrations in soils and sediments may be related to local geological occurrences and to agricultural activities. PAH values are significantly lower than the limit values set by the Italian law.  相似文献   

11.
Xu MX  Yan JH  Lu SY  Li XD  Chen T  Ni MJ  Dai HF  Cen KF 《Chemosphere》2008,71(6):1144-1155
Isomer-specific data were investigated in order to identify the sources of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in agricultural soils, including Fluvo-aquic and paddy soils, in the vicinity of a Chinese municipal solid waste incineration (MSWI) plant. Homologue and isomer profiles of PCDD/Fs in soils were compared with those of potential sources, including combustion sources, i.e., MSWI flue gas and fly ash; and the impurities in agrochemicals, such as the pentachlorophenol (PCP), sodium pentachlorophenate (PCP-Na) and 1,3,5-trichloro-2-(4-nitrophenoxy) benzene (CNP). The results showed that the PCDD/F isomer profiles of combustion sources and agricultural soils were very similar, especially for PCDFs, although their homologue profiles varied, indicating that all the isomers within each homologue behave identically in the air and soil. Moreover, factor analysis of the isomer compositions among 33 soil samples revealed that the contamination of PCDD/Fs in agricultural soils near the MSWI plant were primarily influenced by the combustion sources, followed by the PCP/PCP-Na and CNP sources. This implication is consistent with our previous findings based on chemometric analysis of homologue profiles of soil and flue gas samples, and identifies PCP/PCP-Na as an additional important source of PCDD/Fs in the local area. This makes the similarities and differences of isomer profiles between Fluvo-aquic and paddy soils more explainable. It is, therefore, advisable to use isomer-specific data for PCDD/F source identifications where possible.  相似文献   

12.
Lee SJ  Choi SD  Jin GZ  Oh JE  Chang YS  Shin SK 《Chemosphere》2007,68(5):856-863
Municipal solid waste incinerators (MSWIs) have been shown to be important sources of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). The emission of PCDD/Fs by MSWIs is a controversial subject in human health risk assessment. In this study the effect of a MSWI on a residential area was assessed before and after the installation of an additional treatment system for flue gas. This additional treatment system resulted in a dramatic decrease in PCDD/F concentrations in stack flue gas samples by 99.98%, while the concentrations in air decreased by approximately 50% (36,500 and 0.75 pg I-TEQ m(-3) for air in 1999; 3.5 and 0.38 pg I-TEQ m(-3) in 2002; 1.6 and 0.076 pg I-TEQ m(-3) in 2005 for stack gas and air, respectively). Considering the congener distributions of PCDD/Fs between stack flue gas and air samples, the study area seemed to have been contaminated by other urban sources as well as the MSWI. ISC3 model results support the conclusion that this incinerator became only a minor contributor to the study area after installation of the supplementary systems. This resulted from both proper MSWI operation using modern technology and additional sources of contaminants in this region. Finally, PCDD/F uptake by humans through inhalation of contaminated air was estimated. Assuming that inhalation exposure contributes 10% of total exposure, total exposure was lower than WHO guidelines. These results confirm that proper operation and maintenance of the incinerator led to a reduction in emissions and potential health impacts of PCDD/Fs.  相似文献   

13.
Polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDDs/Fs) were analyzed in samples of the emissions from a secondary aluminum smelter (ALS) and soil samples around the plant. The purpose was to estimate the impact of the emissions on the surrounding environment.PCDD/F soil concentrations were higher in the proximity of the plant, exceeding the limit adopted in Italy in soils for green areas and residential uses and the upper limit of several reference concentrations. The most contaminated sites were less than 500 m from the plant and the dioxin concentration with the distance from the ALS.Principal component analysis (PCA) showed that emissions from the ALS were the source of PCDD/F contamination in the soils closest to the plant. Multivariate data analyses such as PCA are therefore useful to identify sources of emission causing contamination.  相似文献   

14.
《Chemosphere》2012,86(11):1719-1724
Polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDDs/Fs) were analyzed in samples of the emissions from a secondary aluminum smelter (ALS) and soil samples around the plant. The purpose was to estimate the impact of the emissions on the surrounding environment.PCDD/F soil concentrations were higher in the proximity of the plant, exceeding the limit adopted in Italy in soils for green areas and residential uses and the upper limit of several reference concentrations. The most contaminated sites were less than 500 m from the plant and the dioxin concentration with the distance from the ALS.Principal component analysis (PCA) showed that emissions from the ALS were the source of PCDD/F contamination in the soils closest to the plant. Multivariate data analyses such as PCA are therefore useful to identify sources of emission causing contamination.  相似文献   

15.
One goal of the Swedish survey project is to discover possible sources of PCDD/F. Bottom sediment and pike were sampled at various sites near different types of industries along the coast line of two lakes and one river. The results show background levels of PCDD/F in some lakes which can only be explained by atmospheric input. In some lakes paper mill emissions of chlorinated PCDD/F give high levels of local contamination (≈1 ng/g IG) within short distances (<1 km) from the source. PCDD/F from paper mill effluents are transported long distances and traces can be detected over the entire lake area. The PCDD/F levels in pike are correlated with levels in the underlying sediment.  相似文献   

16.
Background, aim, and scope  The primary aim of this study was to explore the variations in PCDD/F levels and homologue profiles of Baltic surface sediments by comprehensively analyzing polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) in samples from a large number of sites, encompassing not only previously known hotspot areas, but also sites near other potential PCDD/F sources, in pristine reference areas (in which there was no industrial activity) and offshore sites. Materials and methods  Surface sediment samples (146 in total) were collected at various points along the Swedish coast and offshore areas. In addition, bulk deposition was sampled, monthly, at a single site in northern Sweden during 1 year. The concentrations of tetra- through octa-substituted CDD/Fs were determined in both matrices. Results  Highly elevated concentrations of PCDD/Fs were found at many sites in coastal areas and concentrations were also slightly elevated in some offshore areas. Homologue profiles varied substantially amongst samples from coastal sites, while those from offshore and other pristine sediments were relatively similar. The offshore sediments showed different profiles from those observed in the deposition samples. Sediment levels of PCDD/Fs were not generally significantly correlated to organic carbon levels, except in some pristine areas. Comparison of data obtained in this and previous studies suggest that both their levels and profiles are similar today to those observed 20 years ago in coastal and offshore areas. The only detected trend is that their levels appear to have decreased slightly in the offshore area of the Bothnian Sea. Discussion  The localization of hotspot areas along the coast, the lack of consensus between PCDD/F profiles of sediments and general background, and their weak correlations with organic carbon suggest that PCDD/Fs in the study area largely originate from local/regional emissions. However, due to complicating factors such as sediment dynamics and land upheaval, it is not possible to conclude whether these pollutants derive from recent emissions or from a combination of recent emissions and re-distribution of previous inputs. Conclusions  The results show that: elevated levels of PCDD/Fs are present in both coastal and offshore areas of the Baltic Sea, the major hotspots are close to the shore, and there are large variations in profiles, indicating that local emissions are (or have been) the major causes of pollution. Recommendations and perspectives  In order to identify other hotspot areas and trace sources, comprehensive analysis of PCDD/Fs in surface sediments is needed in all areas of the Baltic Sea that have not been previously investigated. The high levels of PCDD/Fs observed in surface sediments also indicate a need to elucidate whether they are due mainly to current emissions or a combination of recent pollution and re-distribution of historically deposited pollutants. To do so, better understanding of sediment dynamics and present-day inputs, such as riverine inputs, industrial effluents, and leakage from contaminated soil is required. There are indications that contaminated sediments have a regional impact on fish contamination levels. However, as yet there is no statistically robust evidence linking contaminated sediments with elevated levels in Baltic biota. It should also be noted that the Baltic Sea is being massively invaded by the deep-burrowing polychaete Marenzielleria ssp., whose presence in sediments has been shown to increase water concentrations of hydrophobic pollutants. In awareness of this, it is clear that high levels in sediments cannot be ignored in risk assessments. In order to investigate the emission trends more thoroughly, analysis of PCDD/Fs in offshore sediment cores throughout the Baltic Sea is also recommended. Electronic supplementary material  The online version of this article (doi:) contains supplementary material, which is available to authorized users.  相似文献   

17.
One option of recycling used contaminated packaging is to recover its high energy content. This can be performed in a normal multi-fuel power plant by co-combustion of packaging-derived fuel (PDF) or refuse-derived fuel (RDF) with fossil fuels, such as coal or peat. This work includes the results of 17 co-combustion tests and an evaluation of the results by the Principal Component Analysis (PCA) and the Partial Least Squares Projections to Latent Structures (PLS). PCA and PLS calculations showed that especially Pb, but also Cr, and Cu correlated with lower chlorinated furans (PCDFs) in the fly ash. Correlation between Sn and lower chlorinated dioxins (PCDDs) in the fly ash was also noticed. CO and PAH emission in the flue gas correlated with total PCDD/Fs in the flue gas. In a real full-scale combustion process, a single parameter in fuel, flue gas or a combustion parameter did not provide a guide to PCDD/F formation or to a level of the total PCDD/F emission, but correlations between different parameters and PCDD/Fs could be found. Although PDFs and RDF had catalytic heavy metals and chlorine, the co-combustion results showed that they can be co-combusted with peat and coal in a fluidized-bed boiler at least up to 26 % with very low total PCDD and PCDF emissions.  相似文献   

18.
After entry into force of the Stockholm Convention and Aarhus Protocol and in order to implement the upcoming European legal background, the European countries are asked to apply control measures to reduce the release of persistent organic pollutants (POPs) such as dioxins and furans (PCDD/PCDF) and polychlorinated biphenyls as well as to establish POPs release inventories. In this perspective, development of measuring techniques of emissions is a focal issue in acquiring useful information. In this paper, results of various measurement campaigns at different municipal waste incineration (MWI) plants using long-term automated sampling of PCDD/PCDF are presented. The samples collected from both manual and automated campaigns were analyzed following the European Standard EN-1948:2006 by high-resolution gas chromatograph/high-resolution mass spectrometer. Performances of two different commercial systems have been investigated. Anomalous values occurred during one long-term campaign (22.16 pg I-toxic equivalent (TEQ)/Nm(3)), compared to average values (4-5 pg I-TEQ/Nm(3)) of the MWI. At this maximum value, a main occurrence of abnormal and instable operating conditions has been found. Sampling based on long-term basis was found to be more reliable to monitor PCDD/PCDF emissions than occasional short-term sampling. Nevertheless, the results of long-term campaigns demonstrate that emission levels detected in 15-30 days campaigns, when unsteady operating conditions can occur, as start-up and shut down, are not immediately comparable to the typical levels in a 6-8 h, when operating conditions are generally stable. Moreover, there are often differences observed in the congener profiles between short- and long-term campaigns.  相似文献   

19.
Incremental lifetime health risks due to polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/F) emitted from municipal waste incineration (MSWI) facilities were evaluated for resident population in the area of the plant. Risk assessment was performed through a multipathway combined probabilistic/deterministic approach for analyzing the effects of uncertainty and intrinsic variability of the main PCDD/F emission related parameters on final predicted values. Exposure through direct inhalation of contaminated air, soil ingestion, soil dermal contact and diet were considered, with the propagation of the variability of input parameters throughout the evaluation performed with Monte Carlo simulation techniques. The application to a case study representative of two different technological scenarios (modern facilities equipped with BAT - Best Available Technology - and older incinerators) in a location site typical of Northern Italy situation results in median values of the maximum individual excess risk on the order of 10(-9) and 10(-7) for most recent and older plant configurations, respectively. Corresponding ratios for the 90th and 10th percentile values are around 7 and 9. Individual risk estimates derived for the same scenarios from conventional deterministic approaches, where large conservative assumptions are normally adopted for compensating the lack of knowledge about uncertainty, are essentially comparable with maximum values resulting from the probabilistic approach, thus leading to situations with extreme and very low probabilities of occurrence. PCDD/F health risks from MSWI emissions might thus result largely overestimated if real emission characteristics are not properly considered in the assessment procedure. Sensitivity analysis for identifying the contribution of different input parameters on final predicted risk variance indicates, for the area considered in the simulation, a prevailing influence of PCDD/F stack concentration, with exposures arising from soil deposition phenomena substantially negligible: this latter result further points out the requirements for a very careful identification of base input data values for PCDD/F stack concentrations, at least for those situations where plants are located nearby urban areas.  相似文献   

20.
This report presents results of emission measurements of polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) in the flue gas of seven oil, nine gas, and two wood firing systems under laboratory conditions. The burn rate of the combustion was in the range of the rated useful heat output. Two additional test series varied the amount of combustion air and thus the heat output. The PCDD/PCDF emissions for oil- and gas-fired boilers are in the range of 0.0020-0.0142 ng I-TEQ/m3 (referring to 3% O2 in the dry flue gas). No correlation between the combustion technique and the PCDD/PCDF emissions could be established. In the tests with the wood-fired furnaces PCDD/PCDF concentrations in the flue gas ranging from 0.014 to 0.076 ng I-TEQ/m3 (referring to 13% O2 in the dry flue gas) were found. A significant correlation between the firing rate of the heating insert and the measured PCDD/PCDF concentrations was found. On examination of three typical 2,3,7,8-CDD/CDF congener profiles, a comparable pattern could be observed with natural gas and light fuel oil. The congener distribution for wood combustion is considerably different.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号