1.
The University of Arizona and the Pima County Air Pollution Control District conducted a comparison study of the following aerosol samplers: a standard high-volume sampler, a high-volume sampler fitted with a size selective inlet, and a dichotomous virtual impactor. Over sixty samples were collected with the colocated samplers during the first six months of 1981. The concentration (μg/m3) of suspended particulate matter and of sulfate was determined for all the samples, while the concentration of four lithophilic elements (Ca, Fe, Mg, and K) was determined on one third of the samples. Well-defined linear relationships for suspended particulate matter and sulfate were found to exist between each of the three sample collection methods over the concentrafion range encountered in this study. For these samples, there were significant differences in the particulate mass and large particle lithophilic element concentrations collected by each device. However, sulfate values obtained from the three samplers were in excellent agreement with each other. This suggests that the inlet collection efficiency for large particles differs significantly for these three sampling devices. Since the size selective inlet and the dichotomous virtual impactor samplers are each designed for collection of inhalable particles (particles of 15 μm aerodynamic diameter and smaller), they would have been expected to measure approximately equivalent particle mass concentrations. Thus, these differences are important to those interested in selecting a method for measuring airborne particle mass concentrations.  相似文献   

2.
Considerable interest is currently directed toward atmospheric visibility and its relationship to particle size and mass concentration. Previous work has been limited to heavily polluted urban areas, and visibility studies have not included particle size characterization. An air sampling program was carried out in a nonurban, low pollution area to relate: (a) total particulate mass concentration measured with a high-volume sampler, (b) particulate mass size distribution measured with aerodynamic size selective samplers, and (c) visual range measured by the integrating nephelometer. For low suspended particulate mass concentrations, the following relationship was defined between visual range (Lv) and mass concentration (M ? μg/m3):  相似文献   

3.
ABSTRACT

From 1993 through 1998, Wedding or Graseby high-volume PM10 samplers were collocated with tapered element oscillating microbalance (TEOM) samplers at three sites at Owens Lake, CA. The study area is heavily impacted by windblown dust from the dry Owens Lake bed, which was exposed as a result of water diversions to the city of Los Angeles. A dichotomous (dichot) sampler and three collocated Partisol samplers were added in 1995 and 1999, respectively. U.S. Environmental Protection Agency (EPA) operating procedures were followed for all samplers, except for a Wedding sampler that was not cleaned for the purpose of this study. On average, the TEOM and Partisol samplers agreed to within 6%, and the dichot, Graseby, and Wedding samplers measured lower PM10 concentrations by about 10, 25, and 35%, respectively. Surprisingly, the “clean” Wedding sampler consistently measured the same concentration as the “dirty” Wedding sampler through 85 runs without cleaning. The finding that the Graseby and Wedding high-volume PM10 samplers read consistently lower than the TEOM, Partisol, and dichot samplers at Owens Lake is consistent with PM10 sampler comparisons done in other fugitive dust areas, and with wind tunnel tests showing that sampler cut points can be significantly lower than 10 um under certain conditions. However, these results are opposite of the bias found for TEOM samplers in areas that have significant amounts of volatile particles, where the TEOM reads low due to the vaporization of particles on the TEOM's heated filter. Coarse particles like fugitive dust are relatively unaffected by the filter temperature. This study shows that in the absence of volatile particles and in the presence of fugitive dust, a different systematic bias of up to 35% exists between samplers using dichot inlets and high-volume samplers, which may cause the Graseby and Wedding PM10 samplers to undermeasure PM10 by up to 35% when the PM10 is predominantly from coarse particulate sources.  相似文献   

4.
ABSTRACT

In recent years, scientific discussion has included the influence of thermodynamic conditions (e.g., temperature, relative humidity, and filter face velocity) on PM retention efficiency of filter-based samplers and monitors. Method-associated thermodynamic conditions can, in some instances, dramatically influence the presence of particle-bound water and other light-molecular-weight chemical components such as particulate nitrates and certain organic compounds. The measurement of fine particle mass presents a new challenge for all PM measurement methods, since a relatively greater fraction of the mass is semi-volatile.

The tapered element oscillating microbalance (TEOM) continuous PM monitor is a U.S. Environmental Protection Agency (EPA) PM10 equivalent method (EQPM-1090-079). Several hundred of these monitors are deployed throughout the United States. The TEOM monitor has the unique characteristic of providing direct PM mass measurement without the calibration uncertainty inherent in mass surrogate methods. In addition, it provides high-precision, near-real-time continuous data automatically. Much attention has been given to semi-volatile species retention of the TEOM method.

While using this monitor, it is desirable to maintain as low an operating temperature as practical and to remove unwanted particle-bound water. A new sample equilibration system (SES) has been developed to allow conditioning of the PM sample stream to a lower humidity and temperature level. The SES incorporates a special low-particle-loss Nafion dryer. This paper discusses the configuration and theory of the SES. Performance results include high time-resolved PM2.5 data comparison between a 30 °C sample stream TEOM monitor with SES and a standard 50 °C TEOM monitor. In addition, 24-hr integrated data are compared with data collected using an EPA PM2.5 Federal Reference Method (FRM)-type sampler. The SES is a significant development because it can be applied easily to existing TEOM monitors.  相似文献   

5.
The purpose of this paper is to describe instrumentation to aerodynamically size suspended particulates found in ambient air and to summarize results of field testing utilizing the new technique.

A four-stage, multiorifice high-volume fractionating impactor with backup filter, which can be operated as a component of the standard high-volume sampler, collects particulate matter in five separate aerodynamic size ranges: 7 micrometer (μm) or larger, 3.3 to 7 μm, 2.0 to 3.3 μm, 1.1 to 2.0 μm, and 0.01 to 1.1 μm.

Comparative field tests utilizing duplicate sampling techniques were conducted to determine the feasibility of using the size fractionator on a routine basis in field operations. Verification of the actual particle size separation was not undertaken; however, earlier tests utilizing laboratory-generated aerosols have been performed with satisfactory results.

The results of field tests indicate that the fractionator can be used to determine the aerodynamic size distribution of particulate matter. A glass fiber surface with a pH of 11.0 was found to adsorb atmospheric acid gases during sampling and thus gave erroneous mass concentration results when compared to the standard high-volume sampler. Glass fiber filters with a pH of 6.5 eliminated the acid gas adsorption.  相似文献   

6.
This article concerns the control of emissions from a local dolomite plant through a series of corrective measures. With a new State regulation on particulate emissions (process weight table) passed in 1965, and with a new local control program, a goal was established toward which control measures were directed. Inplant investigations revealed that measures would be necessary to eliminate emissions from the pulverizer and conveyor belts. In order to meet State requirements, a better method of collection for the dryer was required. In order to evaluate the effect of these changes on the ambient air, dustfall jars and high-volume air samplers were used and stack sampling was conducted at and around the local dolomite plant and also at another such plant in Venice, Fla. Through successive control and testing, emission factors for dolomite plants, as well as reduction of plant emissions and resident complaints, were established.  相似文献   

7.
Abstract

Passive samplers have been shown to be an inexpensive alternative to direct sampling. Diffusion denuders have been developed to measure the concentration of species such as ammonia (NH3), which is in equilibrium with particulate ammonium nitrate. Conventional denuder sampling that inherently requires air pumps and, therefore, electrical power. To estimate emissions of NH3 from a fugitive source would require an array of active samplers and meteorological measurements to estimate the flux. A recently developed fabric denuder was configured in an open tube to passively sample NH3 flux. Passive and active samplers were collocated at a dairy farm at the California State University, Fresno, Agricultural Research Facility. During this comparison study, NH3 flux measurements were made at the dairy farm lagoon before and after the lagoon underwent acidification. Comparisons were made of the flux measurements obtained directly from the passive flux denuder and those calculated from an active filter pack sampler and wind velocity. The results show significant correlation between the two methods, although a correction factor needed to be applied to directly compare the two techniques. This passive sampling approach significantly reduces the cost and complexity of sampling and has the potential to economically develop a larger inventory base for ambient NH3 emissions.  相似文献   

8.
This paper describes the results of a study to determine the total mass and the mass distribution of atmospheric aerosols, especially that mass associated with particles greater than 10 μm diameter. This study also determined what fraction of the total aerosol mass a standard high-volume air sampler collects and what fraction and size interval settle out on a dust fall plate. A special aerosol sampling system was designed for this study to obtain representative samples of large airborne particles. A suburban sampling site was selected because no local point sources of aerosols existed nearby. Samples were collected under various conditions of wind velocity and direction to obtain measurements on different types of aerosols.

Study measurements show that atmospheric particulate matter has a bimodal mass distribution. Mass associated with large particles mainly ranged from 5 to 100 μm in size, while mass associated with small particles ranged from an estimated 0.03 to 5 μm in size. Combined, these two distributions produced a bimodal mass distribution with a minimum around 5 μm diameter. The high-volume air sampler was found to collect most of the total aerosol mass, not just that fraction normally considered suspended particulate. Dust fall plates did not provide a good or very useful measure of total aerosol mass. The two fundamental processes of aerosol formation, condensation and dispersion appear to account for the formation of a bimodal mass distribution in both natural and anthropogenic aerosols. Particle size distribution measurements frequently are in error because representative samples of large airborne particles are not obtained. Considering this descrepancy, air pollution regulations should specify or be based upon an upper particle size limit.  相似文献   

9.
The precision and accuracy of the determination of particu-late sulfate and fluoride, and gas phase SO2 and HF are estimated from the results obtained from collocated replicate samples and from collocated comparison samples for high-and low-volume filter pack and annular diffusion denuder samplers. The results of replicate analysis of collocated samples and replicate analyses of a given sample for the determination of spherical aluminosilicate fly ash particles have also been compared. Each of these species is being used in the chemical mass balance source apportionment of sulfur oxides in the Grand Canyon region as part of Project MOHAVE, and the precision and accuracy analyses given in this paper provide input to that analysis. The precision of the various measurements reported here is ±1.8 nmol/m3 and ±2.5 nmol/m3 for the determination of SO2 and sulfate, respectively, with an annular denuder. The precision is ±0.5 nmol/m3 and ±2.0 nmol/m3 for the determination of the same species with a high-volume or low-volume filter pack. The precision for the determination of the sum of HF(g) and fine particulate fluoride is ±0.3 nmol/m3. The precision for the determination of aluminosilicate fly ash particles is ±100 particles/m3. At high concentrations of the various species, reproducibility of the various measurements is ±10% to ±14% of the measured concentration. The concentrations of sulfate determined using filter pack samplers are frequently higher than those determined using diffusion denuder sampling systems. The magnitude of the difference (e.g., 2-10 nmol sulfate/m3) is small, but important relative to the precision of the data and the concentrations of particulate sul-fate present (typically 5-20 nmol sulfate/m3). The concentrations of SO2(g) determined using a high-volume cascade impactor filter pack sampler are correspondingly lower than those obtained with diffusion denuder samplers. The concentrations of SOx (SO2(g) plus particulate sulfate) determined using the two samplers during Project MOHAVE at the Spirit Mountain, NV, and Hopi Point, AZ, sampling sites were in agreement. However, for samples collected at Painted Desert, AZ, and Meadview, AZ, the concentrations of SOx and SO2(g) determined with a high-volume cascade impactor filter pack sampler were frequently lower than those determined using a diffusion denuder sampling system. These two sites had very low ambient relative humidity, an average of 25%. Possible causes of observed differences in the SO2(g) and sulfate results obtained from different types of samplers are given.  相似文献   

10.
From 1993 through 1998, Wedding or Graseby high-volume PM10 samplers were collocated with tapered element oscillating microbalance (TEOM) samplers at three sites at Owens Lake, CA. The study area is heavily impacted by windblown dust from the dry Owens Lake bed, which was exposed as a result of water diversions to the city of Los Angeles. A dichotomous (dichot) sampler and three collocated Partisol samplers were added in 1995 and 1999, respectively. U.S. Environmental Protection Agency (EPA) operating procedures were followed for all samplers, except for a Wedding sampler that was not cleaned for the purpose of this study. On average, the TEOM and Partisol samplers agreed to within 6%, and the dichot, Graseby, and Wedding samplers measured lower PM10 concentrations by about 10, 25, and 35%, respectively. Surprisingly, the "clean" Wedding sampler consistently measured the same concentration as the "dirty" Wedding sampler through 85 runs without cleaning. The finding that the Graseby and Wedding high-volume PM10 samplers read consistently lower than the TEOM, Partisol, and dichot samplers at Owens Lake is consistent with PM10 sampler comparisons done in other fugitive dust areas, and with wind tunnel tests showing that sampler cut points can be significantly lower than 10 microns under certain conditions. However, these results are opposite of the bias found for TEOM samplers in areas that have significant amounts of volatile particles, where the TEOM reads low due to the vaporization of particles on the TEOM's heated filter. Coarse particles like fugitive dust are relatively unaffected by the filter temperature. This study shows that in the absence of volatile particles and in the presence of fugitive dust, a different systematic bias of up to 35% exists between samplers using dichot inlets and high-volume samplers, which may cause the Graseby and Wedding PM10 samplers to undermeasure PM10 by up to 35% when the PM10 is predominantly from coarse particulate sources.  相似文献   

11.
In recent years, scientific discussion has included the influence of thermodynamic conditions (e.g., temperature, relative humidity, and filter face velocity) on PM retention efficiency of filter-based samplers and monitors. Method-associated thermodynamic conditions can, in some instances, dramatically influence the presence of particle-bound water and other light-molecular-weight chemical components such as particulate nitrates and certain organic compounds. The measurement of fine particle mass presents a new challenge for all PM measurement methods, since a relatively greater fraction of the mass is semi-volatile. The tapered element oscillating microbalance (TEOM) continuous PM monitor is a U.S. Environmental Protection Agency (EPA) PM10 equivalent method (EQPM-1090079). Several hundred of these monitors are deployed throughout the United States. The TEOM monitor has the unique characteristic of providing direct PM mass measurement without the calibration uncertainty inherent in mass surrogate methods. In addition, it provides high-precision, near-real-time continuous data automatically. Much attention has been given to semi-volatile species retention of the TEOM method.  相似文献   

12.
Abstract

Protocols have been developed and applied for the generation of aerosols that are likely to be comparable to those encountered in field settings for the calibration of easily transportable/portable real-time particle monitors. Aerosols generated were simulated environmental tobacco smoke, cedar wood smoke, cooking oil fumes, and propane stove particles. The time-integrated responses of three nephelometers and a monitor for particle-bound polynuclear aromatic hydrocarbons (PAH) were compared with gravimetric respirable suspended particulate matter (RSP) in a controlled-atmosphere chamber. In general, the monitor responses increased linearly with increasing mass concentration. However, the two monitors that reported mass per volume concentrations tended to overreport the actual RSP concentrations by factors up to 4.4. The real-time PAH monitor did not respond to cooking oil fumes, indicative of little PAH being present in the aerosol. One of the monitors that has been used in a variety of studies reported in the literature (DustTrak) was collocated with gravimetric RSP samplers in several hospitality venues in the Louisville, KY, area. Field studies indicated that the units overreported actual RSP concentrations by factors of 2.6–3.1, depending on whether the sampling was conducted in the nonsmoking or smoking sections of the facilities.  相似文献   

13.
Abstract

Chemical composition and particle size data for particulate emissions from stationary sources are required for environmental health effect assessments, air chemistry studies and for air quality modeling investigations such as source apportionment. The Information presented In this paper is directed to those individuals concerned with these environmental Investigations. In this study, particulate emissions from a group of non-ferrous smelters have been physically and chemically characterized. Emission samples were collected at the baghouse outlets from smelter furnaces and at smelter acid plant stacks at three locations; a zinc, a lead, and a copper smelter.

Mass emission rate determinations were made by EPA reference methods. Cascade impactors were used to collect in-stack samples for particle size distribution measurements. Particulate samples for chemical characterization were collected on membrane filters for analysis by X-ray fluorescence spectroscopy. Development of measurement techniques required to determine the elemental composition of the total mass and sized fractions of the emission are discussed. Results of the tests at the three smelters include total mass and elemental emission rates, particle size distribution, and the elemental composition of the total particulate mass and of sized fractions from both the smelter furnaces and acid plants. The results obtained at the copper smelter may not be representative of the emissions at the many copper smelters where reverbatory furnaces have been replaced.  相似文献   

14.
This paper deals with the development design, and trial application of a sampling train to gather a relatively large amount of particulate sample in a short period of time. With air pollution sources installing control equipment to reduce emissions to the required low levels, it becomes necessary to use a sampling device which can collect a representative sample in a reasonable period of time. Some of the sampling trains currently being specified are expensive, awkward, and nearly impossible to use under field conditions. The high-volume train overcomes ail of these shortcomings and has some additional advantages. It uses the same glass fiber filter that is specified for ambient air particulate sampling so the emission test results are directly comparable to ambient air sampling data. The laboratories currently weighing and analyzing the glass filters need no additional equipment for the emission sampling analysis. The sample collected by the high-volume probe may be analyzed microscopically for size and characteristics of the particles. This is very important if control equipment is to be specified for the process or source. The high-volume sampler was evaluated on field tests of wood fired boilers, incinerators, wigwam burners, asphalt batching plants, seed cleaning plants, and wood fiber filtration systems. The results of several typical tests using the sampler on these sources are included in the paper.  相似文献   

15.
The present study was carried out with the aim of evaluating the performance of six different aerosol samplers in terms of mass concentration, particle size distribution, and mass fraction for the international size-sampling conventions. The international size-sampling criteria were defined as inhalable, thoracic, and respirable mass fractions with 50% cutoff at an aerodynamic equivalent diameter of 100 μm, 10 μm, and 4 μm, respectively. Two Andersen, four total suspended particulate (TSP), two RespiCon, four PM10, two DustTrak, and two SidePak samplers were selected and tested to quantitatively estimate human exposure in a carefully controlled particulate matter (PM) test chamber. The overall results indicate that (1) Andersen samplers underestimate total suspended PM and overestimate thoracic and respirable PM due to particle bounce and carryover between stages, (2) TSP samplers provide total suspended PM as reference samplers, (3) TSP samplers quantified by a coulter counter multisizer provide no information below an equivalent spherical diameter of 2 μm and therefore underestimate respirable PM, (4) RespiCon samplers are free from particle bounce as inhalable samplers but underestimate total suspended PM, (5) PM10 samplers overestimate thoracic PM, and (6) DustTrak and SidePak samplers provide relative PM concentrations instead of absolute PM concentrations.  相似文献   

16.
The concentrations of polychlorinated dibenzo-p-dioxins and furans (PCDD/Fs), polychlorinated biphenyls (PCBs) and polychlorinated naphthalenes (PCNs) were determined in air samples collected at four sampling sites located in two zones of Barcelona (Spain): near a municipal solid waste incinerator (MSWI) and a combined cycle power plant (3 sites), and at a background/control site. Samples were collected using high-volume active samplers. Moreover, 4 PUF passive samplers were deployed at the same sampling points during three months. For PCDD/Fs, total WHO-TEQ values were 27.3 and 10.9 fg WHO-TEQm(-3) at the urban/industrial and the background sites, respectively. The sum of 7 PCB congeners and the Sigma PCN levels were also higher at the industrial site than at the background site. In order to compare active and passive sampling, the accumulated amounts of PCDD/Fs, PCBs and PCNs in the four passive air samplers, as well as the total toxic equivalents in each sampling site were also determined. To assess the use of PUF passive samplers as a complementary tool for PCDD/F, PCB and PCN monitoring, sampling rates were calculated in accordance with the theory of passive air samplers. PUF disks allowed establishing differences among zones for the POP levels, showing that they can be a suitable method to determine POP concentrations in air in areas with various potential emission sources. Although both particle and gas phase were sorbed by the PUFs, data of gas phase congeners are more reproducible.  相似文献   

17.
Abstract

This paper reports on the performance of the Kimoto 180 sampler and the Wedding ambient PM10 beta gauge sampler. Monodisperse ammonium fluorescein test particles were generated in the laboratory and used to determine the penetration curve of the Kimoto 180 cyclonic inlet. It was found that the actual DpaSOof the Kimoto 180 inlet, 3.5 (xm, is much lower than the designated standard value, 10 um. In the field test, the two beta gauge samplers were collocated with an Andersen SA1200 high-volume sampler to compare their measured daily average PM10 concentrations.

The low Dpa50 of the Kimoto 180 inlet serves to explain why its daily average PM10 concentrations were much lower than the actual PM10 concentrations found in the field study. In addition, the PM10 concentrations of the Kimoto 180 beta gauge sampler were found to be seriously affected by the water vapor content of the ambient air. In contrast, the daily average PM10 concentrations of the Wedding beta gauge sampler were found to be more accurate, and influences by ambient conditions were insignificant  相似文献   

18.
A receptor model of positive matrix factorization (PMF) was used to identify the emission sources of fine and coarse particulates in Bandung, a city located at about 150 km south-east of Jakarta. Total of 367 samples were collected at urban mixed site, Tegalega area, in Bandung City during wet and dry season in the period of 2001–2007. The samples of fine and coarse particulate matter were collected simultaneously using dichotomous samplers and mini-volume samplers. The Samples from dichotomous Samplers were analyzed for black carbon and elements while samples from mini-volume samplers were analyzed for ions. The species analyzed in this study were Na, Mg, Al, Si, K, Ca, Ti, Cr, Mn, Fe, Ni, Cu, Pb, Cl?, NO3?, SO42?, and NH4+. The data were then analyzed using PMF to determine the source factors. Different numbers of source factors were found during dry and wet season. During dry season, the main source factors for fine particles were secondary aerosol (NH4)2SO4, electroplating industry, vehicle emission, and biomass burning, while for coarse particles, the dominant source factors were electroplating industry, followed by aged sea salt, volcanic dust, soil dust, and lime dust. During the wet season, the main source factors for fine particulate matter were vehicle emission and secondary aerosol. Other sources detected were biomass burning, lime dust, soil and volcanic dust. While for coarse particulate matter, the main source factors were sulphate-rich industry, followed by lime dust, soil dust, industrial emission and construction dust.  相似文献   

19.
ABSTRACT

Measurements collected using five real-time continuous airborne particle monitors were compared to measurements made using reference filter-based samplers at Bakers-field, CA, between December 2, 1998, and January 31, 1999. The purpose of this analysis was to evaluate the suitability of each instrument for use in a real-time continuous monitoring network designed to measure the mass of airborne particles with an aerodynamic diam less than 2.5 μm (PM2.5) under wintertime conditions in the southern San Joaquin Valley. Measurements of airborne particulate mass made with a beta attenuation monitor (BAM), an integrating nephelometer, and a continuous aerosol mass monitor (CAMM) were found to correlate well with reference measurements made with a filter-based sampler. A Dusttrak aerosol sampler overestimated airborne particle concentrations by a factor of ~3 throughout the study. Measurements of airborne particulate matter made with a tapered element oscillating microbalance (TEOM) were found to be lower than the reference filter-based measurements by an amount approximately equal to the concentration of NH4NO3 observed to be present in the airborne particles. The performance of the Dusttrak sampler and the integrating nephelometer was affected by the size distribution of airborne particulate matter. The performance of the BAM, the integrating nephelometer, the CAMM, the Dusttrak sampler, and the TEOM was not strongly affected by temperature, relative humidity, wind speed, or wind direction within the range of conditions encountered in the current study. Based on instrument performance, the BAM, the integrating nephelometer, and the CAMM appear to be suitable candidates for deployment in a real-time continuous PM2.5 monitoring network in central California for the range of winter conditions and aerosol composition encountered during the study.  相似文献   

20.
ABSTRACT

A multi-system, high-volume, parallel plate diffusion dénuder Brigham Young University Organic Sampling System (BIG BOSS) was tested using collocated samplers at the Pico Rivera Monitoring Station of the South Coast Air Quality Management District, South Coast Air Basin, in September 1994. Six-hr daytime and 9-hr nighttime samples were collected with a flow of about 200 L/min through each of the three systems designed to collect particles smaller than 2.5, 0.8, and 0.4 mm in a diffusion denuder sampler. Efficiency for the removal of gas phase organic compounds by the diffusion denuder was evaluated using both theoretical predictions and field measurements. Both measured and calculated data indicate high denuder efficiency for the removal of gas phase aromatic and paraffinic compounds. The precision of the BIG BOSS was evaluated using collocated samplers. The precision of determination of total carbon and elemental carbon retained by a quartz filter or of semi-volatile carbonaceous material lost from particles during sampling averaged ±7%. The precision of determination of individual organic compounds averaged ±10%. An average of 42 and 62% of the particulate organic material was semi-volatile organic compounds (SVOCs) lost from particles during sampling for daytime and nighttime samples, respectively. This “negative” sampling artifact was an order of magnitude larger than the “positive” quartz filter artifact due to adsorption of gas phase organic material. Daytime concentrations of fine particulate elemental carbon and nonvolatile organic carbon were higher than nighttime concentrations, but nighttime fine particles contained more semi-volatile organic material than daytime.  相似文献   