首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 312 毫秒
1.
环境监测实验室常使用不同方法进行重复检测作为检测结果质量保证的手段之一。据此对测定水中总铁的两种方法 -邻菲啰啉分光光度法和火焰原子吸收法在校准曲线和检出限、方法精密度和准确度等进行了全面比较,得出两者校准曲线相关性均较好,检出限均为0.03 mg/L,精密度RSD均小于5%,加标回收率均在90%~105%。两者的测定结果无显著性差异。  相似文献   

2.
Xie Y  Zhu Y  Xu FL  Liu X  Xue B  Tao S 《Chemosphere》2007,66(10):1878-1883
A new method was proposed to determine pyrene in mucus, which combined the synchronous fluorimetry with the multiple standard addition method (SFMSA). The method was used to determine pyrene in mucus directly without pretreatment. The method detection limit (MDL) for pyrene in mucus was measured as 0.47 ng/ml with a relative standard deviation of 12.7% (n = 7). The standard addition graph was linear in the range 0.05-50.00 ng/ml (r(2) = 0.9989). SFMSA was validated using a GC/MS method as a reference method, and nice agreement was found. The pyrene in mucus can be directly monitored by SFMSA without solvent extraction of samples. This indicates that SFMSA is more timesaving, less laborious and cheaper than the GC/MS method with solvent extraction. SFMSA has lower MDL and higher average recovery than the GC/MS method.  相似文献   

3.
对土壤中8种有机氯农药(α-HCH、β-HCH、γ-HCH、δ-HCH、p,p’-DDE、p,p’-DDD、o,p’-DDT、p,p’-DDT)进行了分析,使用加速溶剂萃取(ASE)仪对土壤样品中的目标组分进行萃取、凝胶渗透色谱(GPC)仪对萃取液净化、双塔双柱同时进样分析,采用双电子捕获检测器(ECD)同时定性定量测定。结果表明,该方法检测效果较好,8种有机氯农药的回收率在81.3%~88.6%,相对标准偏差为3.9%~5.7%,检出限为0.18~0.37μg/kg。与传统的方法相比,该方法操作简便、重复性好,定性定量更准确。  相似文献   

4.
Contamination and analytical variation can significantly hinder trace analysis of cyclic methyl volatile siloxanes (cVMS); potentially resulting in the report of false positives at concentrations approaching detection limits. To assess detection and variation associated with trace cVMS analysis in environmental matrices, a co-operative laboratory comparison for the analysis of octametylcyclotetrasiloxane (D4), decamethylcylcopentasiloxane (D5), and dodecametylcyclohexasiloxane (D6) in sediment and biota from the Svalbard Archipelago was conducted. Two definitions of detection limits were evaluated in this study; method detection limits (MDL, matrix defined) and limits of detection (LOD, solvent defined). D5 was the only cVMS detected above both LOD (0.08–0.81 ng g−1 ww) and MDL (0.47–2.36 ng g−1 ww) within sediment by all laboratories where concentrations ranged from 0.55 to 3.91 ng g−1 ww. The percentage of positive detects for D5 decreased by 80% when MDL was defined as the detection limit. D5 was also detected at the highest frequency among all laboratories in fish liver with concentrations ranging from 0.72 to 345 ng g−1 ww. Similar to sediment, percentage of positive detects for D5 decreased by 60% across all laboratories for fish livers when using MDL (0.68–3.49 ng g−1 ww). Similar observations were seen with both D4 and D6, indicating that sample matrix significantly contributes to analytical response variation. Despite differences in analytical methods used between laboratories, good agreement was obtained when using MDL to define detection limits. This study shows the importance of incorporating variation introduced by sample matrices into detection limit calculations to insure data accuracy of cVMS at low concentrations.  相似文献   

5.
用超细玻璃纤维滤膜采集杭州市某道路上机动车排放的苯并(a)芘,经超声萃取,高速离心后直接进HPLC分析。在选定的色谱条件下,苯并(a)芘与其他多环芳烃完全分离,绝对进样量在0.8~0.02 ng时线性良好,相关系数为0.99979,最小检出量0.8 pg,加标回收率87.5%~93.8%。  相似文献   

6.
MC analysis of biological tissue is considered to be very difficult due to the lack of validated methods. This is the primary limiting factor for monitoring potential risks in both the flesh of aquatic organisms and the aquatic ecosystem. In this study, an effective method to determine free MCs (MC-LR and MC-RR) in the muscle and liver tissues of freshwater cultured fish was developed using solid-phase extraction (SPE) and liquid chromatography-tandem mass spectrometry (LC/MS-MS). The extraction solvent, time of extraction, eluent and purification of the extract were optimized. Various SPE cartridges were also investigated. In this optimized analytical procedure, an 85% methanol/water solution (v/v) was selected as the extraction solvent, after which the extracts were purified by removing fats and proteins; a HLB cartridge was chosen for MCs enrichment; and 90% methanol containing 0.02% formic acid/water solution (v/v) was used as the eluent. Under the optimized pretreatment conditions and instrument parameters, good recoveries of MC-LR and MC-RR were obtained at three concentrations (0.5, 1.0 and 2.0 µg g?1 dry weight (DW)), with values ranging from 92.5 to 98.3% and 92.1 to 98.6%, respectively. The method detection limit (MDL) for muscle samples was 0.5 µg kg?1 and 0.4 µg kg?1 (DW) for MC-LR and MC-RR, respectively. The MDL for the liver samples was 0.8 µg kg?1 (DW) for both MC-LR and MC-RR. The developed procedure was successfully applied to analyze MCs in the muscle and liver of fish samples collected from a Chinese freshwater aquaculture pond during bloom seasons. The MC-LR concentrations ranged from below the MDL to 4.17 µg kg?1 and the MC-RR concentrations ranged from below the MDL to 2.64 µg kg?1.  相似文献   

7.
Classical methodology based on the application of filters for sampling, followed by extraction and analysis, introduces severe artifacts for semi-volatile compounds like ammonium nitrate. These filter methods do not meet the requirements for the assessment of the impact of aerosols on acidification, air quality and especially on the radiative balance, in terms of required speed, detection limits and selectivity. These artifacts are avoided by using a steam jet aerosol collector sampler, based on scavenging of aerosols by droplet formation, in combination with on-line analytical techniques such as ion-chromatography for nitrate and membrane separation followed by conductivity detection for ammonium. The SJAC sampler combines very low blanks with high efficiency of collection of particles. The ammonium detector and the IC system, based on 1-point internal standard calibration in combination with correction for curved calibration graphs, enables detection of ammonium and nitrate at background conditions, the detection limit is about 0.02 μg m−3 of ammonium and nitrate. Accuracy is, depending on ambient concentration, in the order of 5–10% relative, at a range of 0.05–50 μg m−3. The time resolution is 15–120 min, depending on required detection limit, and is short enough for continuously monitoring the chemical composition of aerosols. Quality assurance and quality control experiments and intercomparison experiments with classical filter methods, thermo-denuder systems, denuder difference methods and other continuous monitoring techniques have shown that the results are reliable. The instrument has successfully been employed in field campaigns in Europe and the US.  相似文献   

8.
Abstract

This paper describes a simple, inexpensive, highly sensitive, selective, and efficient electrochemical method to determine glyphosate (GLY) in samples of milk, orange juice, and agricultural formulation. The oxidation reaction on the electrode surface was electrochemically characterised by cyclic voltammetry (CV) and square wave voltammetry (SWV). The investigation of GLY at carbon paste electrode revealed a non-reversible oxidation peak at +0.95 V versus Ag/AgCl, which was used for electrochemical detection of GLY. The operating parameters (pH, frequency, step potential, and amplitude) were optimised in relation to the peak current intensity, and a calibration curve was set up in a concentration range of 4.40?×?10?8–2.80?×?10?6 mol L?1, with a detection limit of 2?×?10?9 mol L?1. After calibration curve was plotted, the developed procedure was applied to determine GLY in previously contaminated samples: milk and orange juice, and in a commercial formulation, obtaining recovery values between 98.31% and 103.75%. These results show that the proposed method can be used for GLY quantification in different samples with high sensitivity, specificity, stability, and reproducibility.  相似文献   

9.
Because the particulate organic carbon (OC) concentrations reported in U.S. Environment Protection Agency Speciation Trends Network (STN) data were not blank corrected, the OC blank concentrations were estimated using the intercept in particulate matter < or = 2.5 microm in aerodynamic diameter (PM2.5) regression against OC concentrations. The estimated OC blank concentrations ranged from 1 to 2.4 microg/m3 showing higher values in urban areas for the 13 monitoring sites in the northeastern United States. In the STN data, several different samplers and analyzers are used, and various instruments show different method detection limit (MDL) values, as well as errors. A comprehensive set of error structures that would be used for numerous source apportionment studies of STN data was estimated by comparing a limited set of measured concentrations and their associated uncertainties. To examine the estimated error structures and investigate the appropriate MDL values, PM2.5 samples collected at a STN site in Burlington, VT, were analyzed through the application of the positive matrix factorization. A total of 323 samples that were collected between December 2000 and December 2003 and 49 species based on several variable selection criteria were used, and eight sources were successfully identified in this study with the estimated error structures and min values among different MDL values from the five instruments: secondary sulfate aerosol (41%), secondary nitrate aerosol (20%), airborne soil (15%), gasoline vehicle emissions (7%), diesel emissions (7%), aged sea salt (4%), copper smelting (3%), and ferrous smelting (2%). Time series plots of contributions from airborne soil indicate that the highly elevated impacts from this source were likely caused primarily by dust storms.  相似文献   

10.
A sensitive and simple procedure is descrobed for the analysis of the mycotoxin patulin. The method involves extraction of patulin from the sample, silica gel column chromatographic clean-up, preparation of the aniline imine, thin-layer chromatographic separation on silica gel, hydrogen chloride hydrolysis of the imine, and fluorophore formation from the liberated aniline with fluorescamine. A linear calibration curve was obtained for the 10-100 ng range and the limit of detection was 5 ng. Recoveries of patulin from samples of apple juice spiked at 50-500 ppb were quantitative.  相似文献   

11.
Abstract

Because the particulate organic carbon (OC) concentrations reported in U.S. Environment Protection Agency Speciation Trends Network (STN) data were not blank corrected, the OC blank concentrations were estimated using the intercept in particulate matter ≤2.5 µm in aerodynamic diameter (PM2.5) regression against OC concentrations. The estimated OC blank concentrations ranged from 1 to 2.4 μg/m3 showing higher values in urban areas for the 13 monitoring sites in the northeastern United States. In the STN data, several different samplers and analyzers are used, and various instruments show different method detection limit (MDL) values, as well as errors. A comprehensive set of error structures that would be used for numerous source apportionment studies of STN data was estimated by comparing a limited set of measured concentrations and their associated uncertainties. To examine the estimated error structures and investigate the appropriate MDL values, PM2.5 samples collected at a STN site in Burlington, VT, were analyzed through the application of the positive matrix factorization. A total of 323 samples that were collected between December 2000 and December 2003 and 49 species based on several variable selection criteria were used, and eight sources were successfully identi?ed in this study with the estimated error structures and min values among different MDL values from the ?ve instruments: secondary sulfate aerosol (41%), secondary nitrate aerosol (20%), airborne soil (15%), gasoline vehicle emissions (7%), diesel emissions (7%), aged sea salt (4%), copper smelting (3%), and ferrous smelting (2%). Time series plots of contributions from airborne soil indicate that the highly elevated impacts from this source were likely caused primarily by dust storms.  相似文献   

12.
An improved ion chromatographic (IC) method has been developed for the separation of nitrate in filter extracts in the presence of high concentrations of nitrite. This analytical method was successfully used for an indirect measurement of ozone (O3) in outdoor and indoor air, following its collection using a nitrite-impregnated passive sampler. The limit of detection and the limit of quantification, using the modified IC method, were 6 microg l(-1) (3sigma) and 20 microg l(-1) (10sigma), respectively. Improved detection limits and low baseline noise were obtained with the use of eluent generator and high-capacity ion exchange column. The optimized method was used for assessing O3 concentration in both indoor and outdoor environments of 28 child care centers (CCCs) located in different parts of Singapore. The O3 concentrations ranged from 0.1 to 11.95 parts per billion (ppb) in indoor and from 3.2 to 21.7 ppb in outdoor environments during the study period. It was found that, among the CCCs investigated in this study, air-conditioned CCCs and those located in close proximity to traffic emissions had significantly lower O3 concentrations indoors.  相似文献   

13.
The activated sludge respiration inhibition test is an important bacterial test system for the determination of bacterial toxicity of chemical compounds. The exposure period recommended by OECD 209 and ISO 8192 protocols is 30 and 180 min. A modified version of the test was developed which allowed a prolonged incubation period of 27 h to enhance the possibilities of the test system. The test system with the prolonged incubation time was evaluated by the recommended reference compound 3.5-dichlorophenol and showed an EC50 of 6.3 mgl(-1) with a coefficient of variation of 12.7%. Furthermore, the use of an open test system was evaluated showing a comparable toxicity but a higher coefficient of variation than the closed test system. A storage of activated sludge for several days accompanied by a daily feed with OECD nutrient solution should be avoided, for it can cause a decreased sensitivity of the inoculum. Different statistical fit procedures were tested indicating that Weibull fit procedures were superior for extended data sets covering a wide range of concentrations whereas Gamma and Probit fits were appropriate for smaller data sets mainly restricted to the linear part of the dose response curve.  相似文献   

14.
Specific factors of a baseline 222Rn detector installed at Cape Point, South Africa, were studied with the aim of improving its performance. Direct sunlight caused air turbulence within the instrument, resulting in 13.6% variability of the calibration factor. Shading the instrument eliminated this effect. A residual temperature dependence of the calibration factor was reduced to negligible levels with an improved photomultiplier tube. A superior detector head permits field servicing of the instrument, and has reduced one component of the instrumental background by a factor of 2. The other component probably constitutes thoron emissions from the stainless steel walls. The detection limit of the instrument could be reduced from its current 33 to 20 mBq m−3 if the thoron were to be eliminated.  相似文献   

15.
A simple and straightforward method for simultaneous determination of residues of 13 pesticides in honey samples (acrinathrin, bifenthrin, bromopropylate, cyhalothrin-lambda, cypermethrin, chlorfenvinphos, chlorpyrifos, coumaphos, deltamethrin, fluvalinate-tau, malathion, permethrin and tetradifon) from different pesticide classes has been developed and validated. The analytical method provides dissolution of honey in water and an extraction of pesticide residues by n-Hexane followed by clean-up on a Florisil SPE column. The extract was evaporated and taken up by a solution of an injection internal standard (I-IS), ethion, and finally analyzed by capillary gas chromatography with electron capture detection (GC-µECD). Identification for qualitative purpose was conducted by gas chromatography with triple quadrupole mass spectrometer (GC-MS/MS). A matrix-matched calibration curve was performed for quantitative purposes by plotting the area ratio (analyte/I-IS) against concentration using a GC-µECD instrument. According to document No. SANCO/12571/2013, the method was validated by testing the following parameters: linearity, matrix effect, specificity, precision, trueness (bias) and measurement uncertainty. The analytical process was validated analyzing blank honey samples spiked at levels equal to and greater than 0.010 mg/kg (limit of quantification). All parameters were satisfactorily compared with the values established by document No. SANCO/12571/2013. The analytical performance was verified by participating in eight multi-residue proficiency tests organized by BIPEA, obtaining satisfactory z-scores in all 70 determinations. Measurement uncertainty was estimated according to the top-down approaches described in Appendix C of the SANCO document using the within-laboratory reproducibility relative standard deviation combined with laboratory bias using the proficiency test data.  相似文献   

16.
This study was undertaken to validate the “quick, easy, cheap, effective, rugged and safe” (QuEChERS) method using Golden Delicious and Starking Delicious apple matrices spiked at 0.1 maximum residue limit (MRL), 1.0 MRL and 10 MRL levels of the four pesticides (chlorpyrifos, dimethoate, indoxacarb and imidacloprid). For the extraction and cleanup, original QuEChERS method was followed, then the samples were subjected to liquid chromatography-triple quadrupole mass spectrometry (LC-MS/MS) for chromatographic analyses. According to t test, matrix effect was not significant for chlorpyrifos in both sample matrices, but it was significant for dimethoate, indoxacarb and imidacloprid in both sample matrices. Thus, matrix-matched calibration (MC) was used to compensate matrix effect and quantifications were carried out by using MC. The overall recovery of the method was 90.15% with a relative standard deviation of 13.27% (n = 330). Estimated method detection limit of analytes blew the MRLs. Some other parameters of the method validation, such as recovery, precision, accuracy and linearity were found to be within the required ranges.  相似文献   

17.
A rapid Biacore biosensor immunoassay of 4-nonylphenols was developed. Two types of antibodies were used in the study: polyclonal antibodies with high cross-reactivity towards technical 4-nonylphenol and a monoclonal antibody very specific to 4-n-nonylphenol. 9-(p-Hydroxyphenyl)nonanoic acid was immobilized onto surface of a sensor chip. The best assay sensitivity was achieved using a flow rate of 50 microl min(-1) and injection time of 2 min. For the assay incorporating monoclonal antibodies a limit of detection 2 ng ml(-1) for 4-n-nonylphenol was achieved. With polyclonal antibodies one order lower sensitivity was observed for 4-nonylphenols. High background level of calibration curve for technical 4-nonylphenol was decreased by using IgG fraction of polyclonal antibodies in combination with lower amount of immobilised 9-(p-hydroxyphenyl)nonanoic acid. Sensitivity of the assay was improved by using a chip with a new derivative on a surface-N-aminobutyl [2-(4-hydroxyphenyl)ethylamine] (limit of detection--5 ng ml(-1)). Applicability of the developed assays to ecological monitoring was checked in experiments using shellfish samples. 4-n-Nonylphenol from spiked samples was extracted into hexane followed by clean-up on NH2 SPE columns. Calibration curves generated for cockles, mussels and oyster samples were identical (limit of detection about 10 ng g(-1)) whereas for scallop samples a slight decrease (about 5-10%) of absolute response was observed. In the assay using the monoclonal antibody specific to 4-n-nonylphenol 31 shellfish samples were found to be negative. Results obtained with polyclonal antibodies indicated that two scallop samples contained a quantity of 4-nonylphenols. The developed biosensor assay could be applied for shellfish analysis as a preliminary screening method.  相似文献   

18.
In this work the development, validation and application of method using Solid Phase Microexctration (SPME) for the analyses of five pollutants (phenol, 2-nitrophenol, 2,4-dimethylphenol, 2,4-dichlorophenol and 4-chloro, 3-methyl phenol) in supplying water, using gas chromatography (GC) with flame ionization detector (FID) is described. The optimal conditions obtained for SPME were: fiber type: Poliacrylate (PA); extraction time: 40 minutes; extraction temperature: 70°C; amount of salt added to sample (NaCl): 15%; desorption temperature: 8 minutes. The parameters studied in the method validation were: limit of detection (0.3 and 3.5 μ g.L? 1); precision, measured by the variation coefficient (between 2.1 and 8.8%); calibration curve and linearity, by using the external standardization method (between 1 and 50 50 μ g.L? 1). After the methodology development, samples of water collected in Atibaia River (São Paulo - Brazil) were analyzed, using the optimized methodology. Three water samples collected in the rain season showed a peak with retention time close to 4-chloro, 3 methyl phenol further analyzed by Gas Chromatography-Mass Spectrometry for the identity confirmation. In spite of the fact that none target compounds were found in the river water samples analyzed, the presence of two phenols different from those investigated (p-terc butyl phenol; butylated hydroxytoluene) were detected. These results together with the results of the limit of detection (that showed to be lower than the maximum concentration of phenols demanded by different environment control agencies), and the results of the validation, indicate the applicability of this method for the analysis of selected phenols in river water samples.  相似文献   

19.
In this work the development, validation and application of method using Solid Phase Microexctration (SPME) for the analyses of five pollutants (phenol, 2-nitrophenol, 2,4-dimethylphenol, 2,4-dichlorophenol and 4-chloro, 3-methyl phenol) in supplying water, using gas chromatography (GC) with flame ionization detector (FID) is described. The optimal conditions obtained for SPME were: fiber type: Poliacrylate (PA); extraction time: 40 minutes; extraction temperature: 70 degrees C; amount of salt added to sample (NaCl): 15%; desorption temperature: 8 minutes. The parameters studied in the method validation were: limit of detection (0.3 and 3.5 microg.L(- 1)); precision, measured by the variation coefficient (between 2.1 and 8.8%); calibration curve and linearity, by using the external standardization method (between 1 and 50 50 microg.L(- 1)). After the methodology development, samples of water collected in Atibaia River (S?o Paulo - Brazil) were analyzed, using the optimized methodology. Three water samples collected in the rain season showed a peak with retention time close to 4-chloro, 3 methyl phenol further analyzed by Gas Chromatography-Mass Spectrometry for the identity confirmation. In spite of the fact that none target compounds were found in the river water samples analyzed, the presence of two phenols different from those investigated (p-terc butyl phenol; butylated hydroxytoluene) were detected. These results together with the results of the limit of detection (that showed to be lower than the maximum concentration of phenols demanded by different environment control agencies), and the results of the validation, indicate the applicability of this method for the analysis of selected phenols in river water samples.  相似文献   

20.
Dieldrin is a hydrophobic organochlorine insecticide that is persistent in the environment. The fate and transport of dieldrin in trees is important both in the context of potential remediation, as well as food chain impacts through dieldrin transport to shoots and leaves. Experiments were conducted to measure the degree of dieldrin partitioning to plant tissue and the potential for biodegradation of dieldrin in the microbe rich tree rhizosphere. Dieldrin was analyzed in water and plant tissue using headspace solid-phase microextraction (SPME) coupled with gas chromatography. Poplar and willow saplings planted in soil and watered with 10 microgl(-1) dieldrin for up to 9 months showed no adverse effects due to dieldrin exposure and no dieldrin was observed in plant shoots with a method detection limit (MDL) of 7 ngg(-1). One-week hydroponic tests of poplar saplings exposed to aqueous dieldrin also showed no detection of dieldrin in shoots, with an average of 66% of the dieldrin partitioned to the plant roots and an overall mass balance recovery of 76% in the plant-water system. The root concentration factor (RCF) was found to be 30+/-3 ml water g(-1) root. Biodegradation of dieldrin was not observed in an aqueous batch bioreactor containing 8 microgl(-1) dieldrin, nutrients and bacteria from the root zone of a poplar sapling that had been exposed to dieldrin for 9 months. These results show that planting trees is likely to be safe and potentially useful at sites containing low-levels of dieldrin in groundwater.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号