首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 187 毫秒
1.
This study examined the indoor concentrations of a wide range of volatile organic compounds (VOCs) in currently built new apartments every month over a 24-month period and the source characteristics of indoor VOCs. The indoor total VOC (TVOC) concentrations exhibited a decreasing tendency over the 24-month follow-up period. Similar to TVOCs, the median indoor concentrations of 33 of 40 individual VOCs (all except for naphthalene and six halogenated VOCs) revealed decreasing tendencies. In contrast, the indoor concentrations of the six halogenated VOCs did not reveal any definite trend with time. Moreover, the indoor concentrations of those halogenated VOCs were similar to the outdoor concentrations, suggesting the absence of any notable indoor sources of halogenated VOCs. For naphthalene (NT), the indoor concentrations were significantly higher than the outdoor concentrations, suggesting the presence of indoor NT source(s). The floor/wall coverings (39 %) were the most influential indoor source of indoor VOCs, followed by household cleaning products (32 %), wood paneling/furniture (17 %), paints (7 %), and moth repellents (5 %).  相似文献   

2.
A 3-year research project was established in 1999 to create numerical reference data for material emissions during the time of construction and during the first year. Seven buildings, representing the present construction practice in Finland, were investigated. Material emissions were measured by using the field and laboratory cell (FLEC) during the time of construction, in the newly finished, and in the 6- and 12-month-old buildings. The emission rates for volatile organic compounds (VOCs), formaldehyde, and ammonia were determined.The highest total VOCs (TVOC) emissions were measured in the newly finished buildings from the ceiling structure and from some of the PVC floor coverings. These emissions were up to 1300–2000 μg m−2 h−1. Individual VOCs with emission rates above 50 μg m−2 h−1 included 2-(2-butoxyethoxy) ethanol and its acetate, C4–C16-substituted alkylbenzenes, and xylenes. The mean TVOC emission decreased at least to the Finnish M1-class level (200 μg m−2 h−1) from all surfaces and in all the buildings in 6–12 months. The ammonia and formaldehyde emissions from the ceiling structure were 20–60 μg m−2 h−1 in the newly finished buildings and the M1-levels (30/50 μg m−2 h−1) were exceeded in some cases. These emissions even increased in some buildings during the follow-up period indicating the difference between emissions measured in the laboratory and on site from real structures. Reference values based on the means and 95th percentile are presented to be utilised in both quality control and while investigating indoor air quality problems which are suspected to be caused by a defect structure.  相似文献   

3.
Basing on the material emission data obtained in a test chamber, chemical mass balance (CMB) was used to assess the source apportionment of volatile organic compound (VOC) concentrations in three newly built timber frame houses. CMB has been proven to be able to discriminate the source contributions for two contrasted environmental conditions (with and without ventilation). The shutdown of the ventilation system caused an increase in the VOC concentrations due to the increased contribution of indoor surface materials like the door material and furniture explaining together over 65% of total VOCs. While the increase in formaldehyde concentration is mainly due to furniture (contribution of 70%), the increase in α-pinene concentration is almost exclusively attributable to the emission of door material (up to 84%). The apportionment of VOC source contributions appears as highly dependent on the position of source materials in the building (surface materials or internal materials) and the ventilation conditions explaining that the concentrations of compounds after the shutdown of ventilation system do not increase in equivalent proportion. Knowledge of indoor sources and its contributions in real conditions may help in the selection of materials and in the improvement of construction operations to reduce the indoor air pollution.  相似文献   

4.
In 1997, Homeswest in western Australia and Murdoch University developed a project to construct low-allergen houses (LAHs) in a newly developed suburb. Before the construction of LAHs, all potential volatile organic compound (VOC) emission materials used in LAHs are required to be measured to ensure that they are low total VOC (TVOC) emission materials. This program was developed based on this purpose. In recent times, the number of complaints about indoor air pollution caused by VOCs has increased. A number of surveys of indoor VOCs have indicated that many indoor materials contribute to indoor air pollution. Although some studies have been conducted on the characteristics of VOC emissions from adhesives, most of them were focused on VOC emissions from floor adhesives. Few measurements of VOC emissions from adhesives used for wood, fabrics, and leather are available. Furthermore, most research on VOC emissions from adhesives has been done in countries with cool climates, where ventilation rates in the indoor environment are lower than those in Mediterranean climates, due to energy conservation. VOCs emitted from adhesives have not been sufficiently researched to prepare an emission inventory to predict indoor air quality and to determine both exposure levels for the Australian population and the most appropriate strategies to reduce exposure. An environmental test chamber with controlled temperature, relative humidity, and airflow rate was used to evaluate emissions of TVOCs from three adhesives used frequently in Australia. The quantity of TVOC emissions was measured by a gas chromatography/flame ionization detector. The primary VOCs emitted from each adhesive were detected by gas chromatography/mass spectrometry. The temporal change of TVOC concentrations emitted from each adhesive was tested. A double-exponential equation was then developed to evaluate the characteristics of TVOC emissions from these three adhesives. With this double-exponential model, the physical processes of TVOC emissions can be explained, and a variety of emission parameters can be calculated. These emission parameters could be used to estimate real indoor TVOC concentrations in Mediterranean climates.  相似文献   

5.
Bioprocesses, such as biofiltration, are commonly used to treat industrial effluents containing volatile organic compounds (VOCs) at low concentrations. Nevertheless, the use of biofiltration for indoor air pollution (IAP) treatment requires adjustments depending on specific indoor environments. Therefore, this study focuses on the convenience of a hybrid biological process for IAP treatment. A biofiltration reactor using a green waste compost was combined with an adsorption column filled with activated carbon (AC). This system treated a toluene-micropolluted effluent (concentration between 17 and 52 µg/m3), exhibiting concentration peaks close to 733 µg/m3 for a few hours per day. High removal efficiency was obtained despite changes in toluene inlet load (from 4.2 × 10?3 to 0.20 g/m3/hr), which proves the hybrid system’s effectiveness. In fact, during unexpected concentration changes, the efficiency of the biofilter is greatly decreased, but the adsorption column maintains the high efficiency of the entire process (removal efficiency [RE] close to 100%). Moreover, the adsorption column after biofiltration is able to deal with the problem of the emission of particles and/or microorganisms from the biofilter.
ImplicationsIndoor air pollution is nowadays recognized as a major environmental and health issue. This original study investigates the performance of a hybrid biological process combining a biofilter and an adsorption column for removal of indoor VOCs, specifically toluene.  相似文献   

6.
With recent improvements to living standards and renovations to many residential buildings, a large volume of new building materials have been utilized throughout China. Formaldehyde and other kinds of VOC pollutants, such as benzene, toluene and xylene found in new building materials, however, emit gases that may lead to some direct or potential health problems. Bake-out with dilution ventilation technology has the potential to shorten emission cycles of indoor air pollution, by which off-gassing from building materials can be reduced. In this paper, a test chamber was used to represent a newly renovated residential room in China. Experiments were conducted to study the applicability of the technology for removing of formaldehyde, benzene, toluene and xylene. A numerical method was used to simulate a 1 m3-chamber-TVOC removing amount under different operating conditions and the concentration change of TVOC during the bake-out exhaust dilution process. The effects of bake-out temperatures and times, ventilation times, and air change rates on removal are also discussed.

Implications: VOCs are the main study objective in this paper. With higher baking temperature, longer baking time and longer ventilation time, the removal efficiency is higher in experiment. Removal content of TVOC increases with the increasing number of ACH. With the consideration of energy consumption, it is more reasonable to choose a ventilation time of 4 hours if ACH is 1.2 times/h.  相似文献   


7.
Jo WK  Kim JD 《Chemosphere》2010,81(10):1272-1279
The present study measured the levels of 24 selected volatile organic compounds (VOCs) in the personal air samples obtained from graduate students attending the college of natural sciences (GSNSs) or social science (GSSSs) during their daily activities on campus along with associated indoor and outdoor air samples. In addition, the sources of their personal exposure were characterized using multivariate statistical models. In the personal samples of GSNSs and GSSSs, 16 and 15 different VOCs were always detected, respectively. The personal exposure of five chlorinated hydrocarbons and six aromatics was significantly higher for GSNSs than for GSSSs. Consistently, the indoor levels of these compounds were higher for GSNSs (in research and laboratory rooms) than for GSSSs (in research rooms). However, the personal exposure of two aromatic VOCs (1,2,4- and 1,3,5-trimethylbenzene) was higher for GSSSs. Moreover, the personal exposure of the five chlorinated and six aromatic compounds was significantly correlated with VOC concentrations both in the research and laboratory rooms of GSNSs and with those in the research rooms of GSSSs. For certain VOCs, outdoor sources were also a major contributor to the personal exposure of both GSNSs and GSSSs. The multivariate models identified five factors that accounted for 81% of the total variance and four factors that explained 76% of the total variance. It was further suggested that multiple indoor sources in research rooms such as office equipment, building finishing materials, and air fresheners were the main source for the personal exposure to VOCs for GSNSs, whereas building finishing materials were the main source for GSSSs.  相似文献   

8.
To better understand the contribution of biogenic volatile organic compounds to the formation of secondary organic aerosol (SOA) in high mountain regions, ambient aerosols were collected at the summit of Mt. Tai (1534 m, a.s.l.), Central East China (CEC) during the Mount Tai Experiment 2006 campaign (MTX2006) in early summer. Biogenic SOA tracers for the oxidation of isoprene, α/β-pinene, and β-caryophyllene were measured using gas chromatography/mass spectrometry. Most of the biogenic SOA tracers did not show clear diurnal variations, suggesting that they are formed during long-range atmospheric transport or over relatively long time scales. Although isoprene- and α/β-pinene-derived SOA tracers did not correlate with levoglucosan (a biomass burning tracer), β-caryophyllinic acid showed a good correlation with levoglucosan, indicating that crop residue burning may be a source for this acid. Total concentrations of isoprene oxidation products are much higher than those of α/β-pinene and β-caryophyllene oxidation products. The averaged ratio of isoprene to α/β-pinene oxidation products (Riso/pine) was 4.9 and 6.7 for the daytime and nighttime samples, respectively. These values are among the highest in the aerosols reported in different geographical regions, which may be due to the large isoprene fluxes and relatively high levels of oxidants such as OH in CEC. Using a tracer-based method, we estimated the concentrations of secondary organic carbon (SOC) derived from isoprene, α/β-pinene, and β-caryophyllene to be 0.42–3.1 μgC m?3 (average 1.6 μgC m?3) during the daytime and 0.11–4.2 μgC m?3 (1.7 μgC m?3) during the nighttime. These values correspond to 2.9–23% (10%) and 3.2–28% (9.8%) of the total OC concentrations, in which isoprene-derived SOC accounts for 58% and 63% of total SOC during the daytime and nighttime, respectively. This study suggests that isoprene is a more significant precursor for biogenic SOA than α/β-pinene and β-caryophyllene at high altitudes in CEC.  相似文献   

9.
We conducted a comparative study on the indoor air quality for Japan and China to investigate aromatic volatile organic compounds (VOCs) in indoor microenvironments (living room, bedroom, and kitchen) and outdoors in summer and winter during 2006–2007. Samples were taken from Shizuoka in Japan and Hangzhou in China, which are urban cities with similar latitudes. Throughout the samplings, the indoor and outdoor concentrations of many of the targeted VOCs (benzene, toluene, ethylbenzene, xylenes, and trimethylbenzenes) in China were significantly higher than those in Japan. The indoor concentrations of VOCs in Japan were somewhat consistent with those outdoors, whereas those in China tended to be higher than those outdoors. Here, we investigated the differences in VOC concentrations between Japan and China. Compositional analysis of indoor and outdoor VOCs showed bilateral differences; the contribution of benzene in China was remarkably higher than that in Japan. Significant correlations (p < 0.05) for benzene were observed among the concentrations in indoor microenvironments and between the outdoors and living rooms or kitchens in Japan. In China, however, significant correlations were observed only between living rooms and bedrooms. These findings suggest differences in strengths of indoor VOC emissions between Japan and China. The source characterizations were also investigated using principal component analysis/absolute principal component scores. It was found that outdoor sources including vehicle emission and industrial sources, and human activity could be significant sources of indoor VOC pollution in Japan and China respectively. In addition, the lifetime cancer risks estimated from unit risks and geometric mean indoor concentrations of carcinogenic VOCs were 2.3 × 10?5 in Japan and 21 × 10?5 in China, indicating that the exposure risks in China were approximately 10 times higher than those in Japan.  相似文献   

10.
The rapid development of large-scale livestock husbandry has caused serious air pollution problems (e.g., The Tuzuoqi demonstration farm belonging to the Yili Group. The farm is located in the suburb of Hohhot City in northern China). In this study, the gases in typical areas of a large-scale dairy farm were sampled and measured for volatile organic compounds (VOCs), hydrogen sulfide, and ammonia concentrations. Fifty-two species of VOCs were identified. The VOCs emitted from the cowshed mainly consisted of halogenated hydrocarbons (16,960 µg/m3), ketones (15,700 µg/m3), esters (9889 µg/m3), and sulfur compounds (3677 µg/m3). The VOCs from the oxidation pond were mainly composed of halogenated hydrocarbons (21,940 µg/m3) and ketones (3589 µg/m3). The VOCs from the solid–liquid separation tank comprised halogenated hydrocarbons (32,010 µg/m3), ketones (7169 µg/m3), and sulfur compounds (1003 µg/m3). The highest concentrations of ammonia and hydrogen sulfide were obtained from the milking parlor and solid–liquid separation tank, respectively. The ammonia concentration declined gradually due to the superposition of ammonia emitted from the cowshed and milking parlor. Analysis results of the influences of distance and meteorological factors on the dispersion of ammonia and hydrogen sulfide suggested that the dilution factors decreased with increasing distance from the emission source. Within distance ranges of 0–10 and 10–25 m, the concentration dilution factors were positively correlated with wind speed and temperature but negatively correlated with humidity and atmospheric pressure. The results of our work can provide a theoretical basis for the prevention and control of odorous gases in large-scale livestock farms.

Implications: Gases in typical areas of a large-scale dairy farm were sampled, and a total of 52 species of VOCs were identified. The highest concentrations of ketones, sulfur compounds, and esters were obtained at the cowshed (15,700, 3677, and 9889 µg/m3, respectively). Within the distance ranges of 0–10 and 10–25 m, the concentration dilution factors were positively correlated with wind speed and temperature.  相似文献   


11.
The fungi and bacterial levels of the indoor air environments of 77 office buildings were measured in winter and a comparison was made between the buildings with microbe sources in their structures and those without such sources. Penicillium, yeasts, Cladosporium and non-sporing isolates were the commonest fungi detected in the indoor air and in settled dust, in both the mould-damaged and control buildings. Aspergillus ochraceus, Aspergillus glaucus and Stachybotrys chartarium were found only in environmental samples from the mould-damaged buildings. Some other fungi, with growth requiring of water activity, aw, above 0.85, occurred in both the reference and mould-damaged buildings, but such fungi were commoner in the latter type of buildings. The airborne concentrations of Penicillium, Aspergillus versicolor and yeasts were the best indicators of mould damage in the buildings studied. Penicillium species and A. versicolor were also the most abundant fungi in the material samples. This study showed that the fungi concentrations were very low (2–45 cfu m−3 90% of the concentrations being <15 cfu m−3) in the indoor air of the normal office buildings. Although the concentration range of airborne fungi was wider for the mould-damaged buildings (2–2470 cfu m−3), only about 20% of the samples exceeded 100 cfu m−3. The concentrations of airborne bacteria ranged from 12 to 540 cfu m−3 in the control buildings and from 14 to 1550 cfu m−3 in the mould-damaged buildings. A statistical analysis of the results indicated that bacteria levels are generally <600 cfu m−3 in office buildings in winter and fungi levels are <50 cfu m−3. These normal levels are applicable to subarctic climates for urban, modern office buildings when measurements are made using a six-stage impactor. These levels should not be used in evaluations of health risks, but elevated levels may indicate the presence of abnormal microbe sources in indoor air and a need for additional environmental investigations.  相似文献   

12.
The fluorotelomer alcohols (FTOHs) have been detected in various environmental compartments, including indoor and outdoor air, in North America and Europe. In our previous studies, FTOHs were detected at a relative higher concentration in outdoor air in the Keihan (Kyoto–Osaka, one of the major industrial zones) area, Japan compared to reported data. The exposure level of FTOHs in indoor air in the Keihan area remains unclear. In the present study, indoor air FTOH concentrations were investigated using a passive air sampler containing activated carbon felts. The indoor air sampling was conducted in 49 households of the Keihan area, during winter and summer 2008. Most samples contained 6:2 FTOH, 8:2 FTOH, 10:2 FTOH and 8:2 FTOAc. The median concentration of 8:2 FTOH (5.84 ng m?3) was highest among fluorotelomers, followed by those of 10:2 FTOH (1.12 ng m?3), 6:2 FTOH (0.29 ng m?3), and others. Significant correlations among fluorotelomers were observed in collected samples. The association between housing conditions and 8:2 FTOH concentrations showed that samples collected from bed rooms have higher 8:2 FTOH concentrations than those collected from other locations. In addition, samples collected in winter showed lower levels of 8:2 FTOH than those collected in summer. These findings suggest that 8:2 FTOH is the predominant component among fluorotelomers in indoor air, and that there are emission sources of fluorotelomers in indoor environments of the Keihan area. Further investigations into the origins of fluorotelomers are needed to evaluate indoor contamination with fluorotelomers.  相似文献   

13.
Abstract

Biofiltration of periodically fluctuating concentrations of an α-pinene-laden waste gas was investigated to treat both high-frequency and low-frequency fluctuations. The effects of periodic concentration fluctuations on biofilter performance were measured. Controlled variables of periodic operation included cycle period and amplitude. The cycle period ranged from 10 min to 6 days, with the inlet α-pinene concentration fluctuating between 0 and 100 parts per million volume. At high-frequency concentration cycling (i.e., on the order of minutes), both cyclic and constant concentration biofilters maintained similar long-term performance with an average removal efficiency of 77% at an averaged loading rate of 29 g α-pinene/m3 bed/hr. A first approximation suggests kinetics that are time-independent, indicating that steady-state data can be used to predict transient behavior at this time scale. Cyclic biofilter operation with a cycle period of 24 hr (with equal on/off time) was achievable for biofilters without a significant loss in performance. At longer time scales, cyclic biofilter performance decreased at the restart of the ON cycle. The recovery time to previous levels of performance increased with increasing cycle period; the recovery time was less than 1 hr for a cycle period of 24 hr and between 6 and 8 hr for a cycle period of 6 days.  相似文献   

14.
A total of 34 volatile organic compounds (VOCs) were measured in the indoor of laboratories, offices and classrooms of the Chemical Engineering Department of Hacettepe University in Ankara in 2 week-day passive sampling campaigns. The average concentrations ranged from 0.77 to 265 μg m?3 at the different indoor sites, with the most abundant VOC found to be toluene (119.6 μg m?3), followed by styrene (21.24 μg m?3), 2-ethyltoluene (17.11 μg m?3), n-hexane (10.21 μg m?3) and benzene (9.42 μg m?3). According to the factor analysis, the evaporation of solvents used in the laboratories was found to be the dominant source.  相似文献   

15.
Shin SH  Jo WK 《Chemosphere》2012,89(5):569-578
The present study investigated the indoor concentrations of selected volatile organic compounds (VOCs) and formaldehyde and their indoor emission characteristics in newly-built apartments at the pre-occupancy stage. In total, 107 apartments were surveyed for indoor and outdoor VOC concentrations in two metropolitan cities and one rural area in Korea. A mass balanced model was used to estimate surface area-specific emission rates of individual VOCs and formaldehyde. Seven (benzene, ethyl benzene, toluene, m,p-xylene, o-xylene, n-hexane, and n-heptane) of 40 target compounds were detectable in all indoor air samples, whereas the first five were detected in all outdoor air samples. Formaldehyde was also predominant in the indoor air samples, with a high detection frequency of 96%. The indoor concentrations were significantly higher than the outdoor concentrations for aromatics, alcohols, terpenes, and ketones. However, six halogenated VOCs exhibited similar concentrations for indoor and outdoor air samples, suggesting that they are not major components emitted from building materials. It was also suggested that a certain portion of the apartments surveyed were constructed by not following the Korean Ministry of Environment guidelines for formaldehyde emissions. Toluene exhibited the highest emission rate with a median value of 138 μg m−2 h−1. The target compounds with median emission rates greater than 20 μg m−2 h−1 were toluene, 1-propanol, formaldehyde, and 2-butanone. The wood panels/vinyl floor coverings were the largest indoor pollutant source, followed by floorings, wall coverings, adhesives, and paints. The wood panels/vinyl floor coverings contributed nearly three times more to indoor VOC concentrations than paints.  相似文献   

16.
Indoor air quality (IAQ) in schools is a matter of concern because children are most vulnerable and sensitive to pollutant exposure. Conservation of energy at the expense of ventilation in heating, ventilation, and air conditioning (HVAC) systems adversely affects IAQ. Extensive use of new materials in building, fitting, and refurbishing emit various pollutants such that the indoor environment creates its own discomfort and health risks. Various schools in Kuwait were selected to assess their IAQ. Comprehensive measurements of volatile organic compounds (VOCs) consisting of 72 organic compounds consisting of aliphatic (C3–C6), aromatic (C6–C9), halogenated (C1–C7), and oxygenated (C2–C9) functional groups in indoor air were made for the first time in schools in Kuwait. The concentrations of indoor air pollutants revealed hot spots (science preparation rooms, science laboratories, arts and crafts classes/paint rooms, and woodworking shops/decoration rooms where local sources contributed to the buildup of pollutants in each school. The most abundant VOC pollutant was chlorodifluoromethane (R22; ClF2CH), which leaked from air conditioning (AC) systems due to improper operation and maintenance. The other copious VOCs were alcohols and acetone at different locations due to improper handling of the chemicals and their excessive uses as solvents. Indoor carbon dioxide (CO2) levels were measured, and these levels reflected the performance of HVAC systems; a specific rate or lack of ventilation affected the IAQ. Recommendations are proposed to mitigate the buildup of indoor air pollutants at school sites.

Implications: Indoor air quality in elementary schools has been a subject of extreme importance due to susceptibility and sensibility of children to air pollutants. The schools were selected based on their surrounding environment especially downwind direction from the highly industrialized zone in Kuwait. Extensive sampling from different sites in four schools for comprehensive VOCs and CO2 were completed for an extended period of over a year. Different hot spots were identified where leaked refrigerant and inadequate handling of laboratory solvents contributed to the high VOCs in the respective locations. CO2 levels reflected HVAC performance and poor ventilation. A list of recommendations has been proposed to eradicate these high levels of air pollution.  相似文献   


17.
Residential interior door positions influence the pollutant concentrations that result from short-term indoor sources, such as cigarettes, candles, and incense. To elucidate this influence, we reviewed past studies and conducted new experiments in three residences: a single-story 714 m3 ranch-style house, a 510 m3 two-story split-level house, and a 200 m3 two-story house. During the experiments, we released sulfur hexafluoride or carbon monoxide tracer gas over short periods (≤30 min) and measured concentrations in the source room and at least one other (receptor) room for various interior door opening positions. We found that closing a door between rooms effectively prevented transport of air pollutants, reducing the average concentration in the receptor room relative to the source room by 57–100% over exposure periods of 1–8 h. When intervening doors were partially or fully open, the reduction in average concentrations ranged from 3% to 99%, varying as a function of door opening width and the distance between source and receptor rooms.  相似文献   

18.
A nationwide study of indoor air concentrations of 26 VOCs was conducted in Canada in 1991. The study design was based upon random selection of private residences from 1986 Census data and incorporated a temporal stratification feature that allowed sampling of residences in each of four regions of the country at different times of the year with equal probability. Average 24 h concentrations of 26 VOCs in 754 residences were obtained by a passive monitoring method. Initially, climatic parameters were found to have the second highest relative weight among 14 factors identified by factor analysis. Further analysis by linear regression showed that individual VOC concentrations and average outdoor temperature or relative humidity were poorly correlated (r > 0.13). Detailed analysis of the data from four regions of Canada also gave poor correlations between household VOC concentrations and temperature or relative humidity. Concentrations of all 26 VOCs averaged 7.8 μg m−3 in winter, 10.3 μg m−3 in spring, 4.4 μg m−3 in summer and 10.8μ m−3 in fall. The highest concentrations of individual compounds averaged 84μm−3 for toluene in the spring and 42 μg m−3 in the fall, and 44 μg m−3 for decane in the spring and 48 μg m−3 in the fall. Segregation of the results into outdoor temperature ranges of 0°C, 0–15 and > 15°C gave mean indoor VOC concentrations of 10.3, 9.8 and 50μgm−3, respectively. Further examination of the results revealed that the likely presence of sources within homes had a far greater influence on indoor concentrations than ventilation which is partly influenced by climate.  相似文献   

19.
The present work investigated the levels of total volatile organic compounds (TVOC) and benzene, toluene, ethylbenzene, m/p-xylene, and o-xylene (BTEX) in different microenvironments in the library of Jawaharlal Nehru University in summer and winter during 2011–2012. Carcinogenic and non-carcinogenic health risks due to organic compounds were also evaluated using US Environmental Protection Agency (USEPA) conventional approaches. Real-time monitoring was done for TVOC using a data-logging photo-ionization detector. For BTEX measurements, the National Institute for Occupational Safety and Health (NIOSH) standard method which consists of active sampling of air through activated charcoal, followed by analysis with gas chromatography, was performed. Simultaneously, outdoor measurements for TVOC and BTEX were carried out. Indoor concentrations of TVOC and BTEX (except benzene) were higher as compared to the outdoor for both seasons. Toluene and m/p-xylene were the most abundant organic contaminant observed in this study. Indoor to outdoor (I/O) ratios of BTEX compounds were generally greater than unity and ranged from 0.2 to 8.7 and 0.2 to 4.3 in winter and summer, respectively. Statistical analysis and I/O ratios showed that the dominant pollution sources mainly came from indoors. The observed mean concentrations of TVOC lie within the second group of the Molhave criteria of indoor air quality, indicating a multifactorial exposure range. The estimated lifetime cancer risk (LCR) due to benzene in this study exceeded the value of 1?×?10?6 recommended by USEPA, and the hazard quotient (HQ) of non-cancer risk came under an acceptable range.  相似文献   

20.
A comprehensive assessment of indoor carbonyl compounds for the academic staff, workers, and students was conducted on a university campus in Xiamen, China. A total of 15 representative environment categories, including 12 indoor workplaces and three residential units, were selected. The potential indoor pollution sources were identified based on the variability in the molar compositions and correlation analyses for the target carbonyls. Furnishing materials, cooking emissions, and electronic equipment, such as photocopiers, can generate various carbonyls in the workplace. Comparison studies were conducted in the clerical offices, demonstrating that off-gases from wooden furniture and lacquer coatings, environmental tobacco smoke (ETS), and the use of cleaning reagents elevated the indoor carbonyl levels. The measured concentrations of formaldehyde and acetaldehyde in most locations surpassed the exposure limit levels. The lifetime cancer hazard risk (R) associated with formaldehyde was above the concern risk level (1 × 10?6) in all of the workplaces. The results indicate that formaldehyde exposure is a valid occupational health and safety concern. Wooden furniture and refurbishing materials can pose serious health threats to occupants. The information in this study could act as a basis for future indoor air quality monitoring in Mainland China.
Implications:A university campus represents a microscale city environment consisting of all the working, living, and commercial needs of staff and students. The scope of this investigation covers 21 hazardous carbonyl species based on samples collected from 15 categories of workplaces and residential building in a university campus in southern China. Findings of the study provide a comprehensive assessment of indoor air quality with regards to workers’ health and safety. No similar study has been carried out in China.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号