首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 343 毫秒
1.
Biofiltration of high loads of ethyl acetate in the presence of toluene.   总被引:1,自引:0,他引:1  
To date, biofilters have been used primarily to control dilute, usually odorous, off-gases with relatively low volatile organic compound (VOC) concentrations (< 1 g m-3) and VOC loads (< 50 g m-3 hr-1). Recently, however, U.S. industry has shown an interest in applying biofilters to higher concentrations of VOCs and hazardous air pollutants (HAPs). In this study, the behavior of biofilters under high loads of binary VOC mixtures was studied. Two bench-scale biofilters were operated using a commercially available medium and a mixture of wood chips and compost. Both were exposed to varying mixtures of ethyl acetate and toluene. Concentration profiles and the corresponding removal efficiencies as a function of VOC loading were determined through frequent grab-sampling and GC analysis. Biofilter response to two frequently encountered operating problems--media dry-out and operating temperatures exceeding 40 degrees C--was also evaluated under controlled conditions. Microbial populations were also monitored to confirm the presence of organisms capable of degrading both major off-gas constituents. The results demonstrated several characteristics of biofilters operating under high VOC load conditions. Maximum elimination capacities for ethyl acetate were typically in the range of 200 g m-3 hr-1. Despite the presence of toluene degraders, the removal of toluene was inhibited by high loads of ethyl acetate. Several byproducts, particularly ethanol, were formed. Short-term dry-out and temperature excursions resulted in reduced performance.  相似文献   

2.
In the northeast of Italy, high volatile organic carbon (VOC) emissions originate from small-medium companies producing furniture. In these conditions it is difficult to propose a single, efficient, and economic system to reduce pollution. Among the various choices, the biofiltration method could be a good solution, because microbial populations possess multiple VOC degradation potentials used to oxidize these compounds to CO2. Starting from the air emissions of a typical industrial wood-painting plant, a series of experiments studied in vitro microbial degradation of each individual VOC. Isolated strains were then added to a laboratory-scale biofiltration apparatus filled with an organic matrix, and the different VOC behavior demonstrated the potential of single and/or synergic microbial removal actions. When a single substrate was fed, the removal efficiency of a Pseudomonas aeruginosa inoculated reactor was 1.1, 1.17, and 0.33 g m(-3) hr(-1), respectively, for xylene, toluene, and ethoxy propyl acetate. A VOC mixture composed of butyl acetate, ethyl acetate, diacetin alcohol, ethoxy propanol acetate, methyl ethyl ketone, methyl isobutyl ketone, toluene, and xylene was then fed into a 2-m(3) reactor treating 100 m3 hr(-1) of contaminated air. The reactor was filled with the same mixture of organic matrix, enriched with all of the isolated strains together. During reactor study, different VOC loading rates were used, and the behavior was evaluated continuously. After a short acclimation period, the removal efficiency was > 65% at VOC load of 150-200 g m(-3) hr(-1). Quantification of removal efficiencies and VOC speciation confirmed the relationship among removal efficiencies, compound biodegradability, and the dynamic transport of each mixture component within the organic matrix. Samples of the fixed bed were withdrawn at different intervals and the heterogeneous microbial community evaluated for both total and differential compound counts.  相似文献   

3.
A pilot apparatus of a regenerative catalytic oxidizer (RCO) equipped with two electrical heaters and two 20-cm i.d. x 200-cm height regenerative beds was used to treat methyl ethyl ketone (MEK) and toluene, respectively, in an airstream. The regenerative beds were packed with gravel (approximate particle size 1.25 cm, specific area 205 m2/m3, and specific heat capacity 840 J/kg degree C) as a solid regenerative material and K-type thermal couples for measuring solid and gas temperatures, respectively. The catalyst bed temperature was kept around 400 degrees C and the gas superficial velocity was operated at 0.234 m/sec. This investigation measured and analyzed distributions of solid and gas temperatures with operating time and variations of volatile organic compound (VOC) concentrations in the regenerative beds. The overall VOC removal efficiency exceeded 98% for MEK and 95% for toluene. Degradation of VOCs will exist for MEK on the surface of solid material (gravel) in the temperature range of 330-400 degrees C, but toluene does not exhibit this phenomenon.  相似文献   

4.
ABSTRACT

A pilot apparatus of a regenerative catalytic oxidizer (RCO) equipped with two electrical heaters and two 20-cm i.d. × 200-cm height regenerative beds was used to treat methyl ethyl ketone (MEK) and toluene, respectively, in an airstream. The regenerative beds were packed with gravel (approximate particle size 1.25 cm, specific area 205 m2/m3, and specific heat capacity 840 J/kg °C) as a solid regenerative material and K-type thermal couples for measuring solid and gas temperatures, respectively. The catalyst bed temperature was kept around 400 °C and the gas superficial velocity was operated at 0.234 m/sec. This investigation measured and analyzed distributions of solid and gas temperatures with operating time and variations of volatile organic compound (VOC) concentrations in the regenerative beds. The overall VOC removal efficiency exceeded 98% for MEK and 95% for toluene. Degradation of VOCs will exist for MEK on the surface of solid material (gravel) in the temperature range of 330-400 °C, but toluene does not exhibit this phenomenon.  相似文献   

5.
Cheng WH  Chou MS  Perng CH  Chu FS 《Chemosphere》2004,54(7):935-942
The single equilibration technique (SET) was adopted to determine the partitioning coefficients (pc) at an air-water interface for volatile organic compounds (VOCs), including ethanol, iso-propanol (IPA), iso-butanol (IBA), methyl ethyl ketone (MEK) and toluene, all extensively used in industrial processes. Standard SET procedures were established. The liquid concentrations (CL) of tested VOCs ranged from 10 to 125 mg l(-1) for alcohols and MEK, and from 0.5 to 20 mg l(-1) for toluene. The temperatures (Tw) of aqueous VOC solutions were maintained at 27, 32, 38 and 42 degrees C to determine the gaseous concentrations at equilibrium (Cg*) and pc of VOCs, using the formula pc=(Cg*/CL). Results reveal that the pc values of all tested components increase slowly with Tw given a constant CL, and that the pc of alcohols and MEK fall as CL increases at a constant Tw. In contrast, the pc of toluene is not significantly impacted by a variation in CL at a constant Tw. However, the effect of CL concentration has seldom been discussed. The heats of liquid and gaseous phase transfer (DeltaHtr) of VOC, and the highly linear regression (with squared correlation coefficients, R2, from 0.901 to 0.999) between lnCg* and Tw(-1) are also evaluated. The experimental results and the VOC mass transfer characteristics are helpful for evaluating the emission of VOC from the water surface of wastewater treatment facilities.  相似文献   

6.
Cai Z  Kim D  Sorial GA 《Chemosphere》2007,68(6):1090-1097
Two independent parallel trickling bed air biofilters (TBABs) ("A" and "B") with two different typical VOC mixtures were investigated. Toluene, styrene, methyl ethyl ketone (MEK), and methyl isobutyl ketone (MIBK) were the target VOCs in the mixtures. Biofilter "A" was fed equal molar ratio of the VOCs and biofilter "B" was fed a mixture based on EPA 2003 emission report. Backwashing and substrate starvation operation were conducted as biomass control. Biofilter "A" and "B" maintained 99% overall removal efficiency for influent concentration up to 500 and 300 ppmv under backwashing operating condition, respectively. The starvation study indicated that it can be an effective biomass control for influent concentrations up to 250 ppmv for biofilter "A" and 300 ppmv for "B". Re-acclimation of biofilter performance was delayed with increase of influent concentration for both biofilters. Starvation operation helped the biofilter to recover at low concentrations and delayed re-acclimation at high concentrations. Furthermore, re-acclamation for biofilter "B" was delayed due to its high toluene content as compared to biofilter "A". The pseudo first-order removal rate constant decreased with increase of volumetric loading rate for both biofilters. MEK and MIBK were completely removed in the upper 3/8 media depth. While biofilter depth utilization for the removal of styrene and toluene increased with increase of influent concentrations for both biofilters. However, toluene removal utilized more biofilter depth for biofilter "B" as compared to biofilter "A".  相似文献   

7.
Lee TH  Kim J  Kim MJ  Ryu HW  Cho KS 《Chemosphere》2006,63(2):315-322
With ketone pollution forming an ever-growing problem, it is important to identify a ketone-degrading microorganism and establish its effect. Here, a methyl ethyl ketone (MEK)-degrading bacterium, Pseudomonas sp. KT-3, was isolated and its MEK degradation characteristics were examined in liquid cultures and a polyurethane-packed biofilter. In liquid cultures, strain KT-3 could degrade other ketone solvents, including diethyl ketone (DK), methyl propyl ketone (MPK), methyl isopropyl ketone (MIPK), methyl isobutyl ketone (MIBK), methyl butyl ketone (MBK) and methyl isoamyl ketone (MIAK). The maximum specific growth rate (mumax) of the isolate was 0.136 h(-1) in MEK medium supplemented with MEK as a sole carbon source, and kinetically, the maximum removal rate (Vm) and saturation constant (Km) for MEK were 12.28 mM g(-1)DCW h(-1) (DCW: dry cell weight) and 1.64 mM, respectively. MEK biodegradation by KT-3 was suppressed by the addition of MIBK or acetone, but not by toluene. In the tested biofilter, KT-3 exhibited a>90% removal efficiency for MEK inlet concentrations of around 500 ppmv at a space velocity (SV) of 150 h(-1). The elimination capacity of MEK was more influenced by SV than by the inlet concentration. Kinetic analysis showed that the maximum MEK removal rate (Vm) was 690 g m(-3) h(-1) and the saturation constant (Km) was 490 ppmv. Collectively, these results indicate the polyurethane sequencing batch biofilter with Pseudomonas sp. KT-3 will provide an excellent performance in the removal of gaseous MEK.  相似文献   

8.
ABSTRACT

This research investigated and compared the use of both bench- and pilot-scale biofilters to determine the effectiveness of controlling styrene, methyl ethyl ketone (MEK), and acetone emissions from an industrial gas waste stream. Critical operating parameters, including contaminant loading rate, temperature, and empty bed contact time, were manipulated in both the laboratory and field. At steady-state conditions, the bench and pilot-scale biofilters showed a 99% removal efficiency for styrene when the contaminant loading rate was less than 50 g m-3hr-1 and 40 g m-3hr-1, respectively. Although few data points were collected in the pilot-scale reactor where the styrene load was greater than 40 g m-3hr-1, the total organic contaminant load including both MEK and acetone typically ranged between 50 g m-3hr-1 and 80 g m-3hr-1. Greater than 99% removal efficiencies were observed for acetone and MEK in the pilot-scale biofilter at all evaluated loading rates. Also studied were biofilter acclimation and re-acclimation periods. In inoculated bench and pilot biofilter systems, microbial acclimation to styrene was achieved in less than five days. In comparison, no MEK degrading microbial inoculum was added, so during the first months of pilot-scale biofilter operation, MEK removal efficiencies lagged behind those noted with styrene.  相似文献   

9.
When present in the vadose zone, potentially toxic nitrate and perchlorate anions can be persistent sources of groundwater contamination. Gaseous electron donor injection technology (GEDIT), an anaerobic variation of petroleum hydrocarbon bioventing, involves injecting electron donor gases, such as hydrogen or ethyl acetate, into the vadose zone, to stimulate biodegradation of nitrate and perchlorate. Laboratory microcosm studies demonstrated that hydrogen and ethanol promoted nitrate and perchlorate reduction in vadose zone soil and that moisture content was an important factor. Column studies demonstrated that transport of particular electron donors varied significantly; ethyl acetate and butyraldehyde were transported more rapidly than butyl acetate and ethanol. Nitrate removal in the column studies, up to 100%, was best promoted by ethyl acetate. Up to 39% perchlorate removal was achieved with ethanol and was limited by insufficient incubation time. The results demonstrate that GEDIT is a promising remediation technology warranting further validation.  相似文献   

10.
A polysulfone microporous membrane module was investigated for control of 1-butanol-contaminated gas streams. A diurnal loading condition, using two different butanol concentrations, was used to simulate start-up and stop conditions associated with shift work. The membrane module was also used to remove 1-butanol from air under continuous loading conditions in a bioreactor. The reactors were seeded with a mixed bacterial consortium capable of butanol biodegradation. Biokinetic parameters for butanol utilization were determined for the culture to be a maximum specific utilization rate (k) equal to 4.3 d(-1) and a half saturation constant (Ks) equal to 8.9 mg L(-1). A biofilter running only with diurnal loading conditions giving a "40-hr work-week" had an average 1-butanol removal rate of 29% (111 ppm, 74 gm(-3) hr(-1)) from a 350-ppm influent at the end of an 8-hr operational day. End-of-day removal varied between 4 and 67% during the operational period. With continuous steady-state operation followed by placement on a diurnal loading schedule and influent butanol concentrations increased to 700 ppm, butanol removal averaged 38% (269 ppm, 145 gm-3 hr(-1)). Under continuous loading, steady-state conditions, 1-butanol removal from the airstream was greater than 99% (200 ppm, 73 gm-3 hr(-1)). These results suggest that the bioreactor can be operated on a diurnal schedule or 40-hr week operational schedule without any decline in performance.  相似文献   

11.
不同洗脱剂对有机氯农药污染场地土壤修复效果比较   总被引:4,自引:1,他引:3  
为了筛选出能有效修复有机氯农药污染土壤的洗脱剂,选取了16种洗脱剂对2种复合有机氯农药(六六六(HCHs)和滴滴涕(DDTs)、氯丹和灭蚁灵)污染场地土壤进行超声洗脱修复。结果表明,对于HCHs和DDTs复合污染土壤,乙酸乙酯和丙酮对HCHs的洗脱率最高,分别为87.6%和87%,其余有机溶剂对其洗脱率也在70%以上。乙酸乙酯和丙酮对于DDT仍为最优,分别为86.9%与78.4%,其余有机试剂对DDT的洗脱率在60%以上。相对于有机溶剂,表面活性剂对HCHs和DDTs复合污染土壤的洗脱效果不好,总洗脱率均低于4%。同样,对于氯丹和灭蚁灵复合污染土壤,有机溶剂的洗脱效果也明显优于表面活性剂。有机溶剂对灭蚁灵的洗脱率,除了正丙醇较低(63.5%)外,其余均在80%左右。对氯丹的洗脱率,除石油醚(59.6%)、正己烷(49.3%)和正丙醇(42%),其余均在70%以上。相同摩尔浓度的表面活性剂中,吐温80对氯丹的洗脱率为54%,环糊精为20%,鼠李糖脂和曲拉通100为13%左右,其余则小于5%,吐温80对灭蚁灵的洗脱率为29.6%,曲拉通100的为12.4%,鼠李糖脂为5.7%,其余则更低。因此,高效低毒的有机试剂,如乙酸乙酯、丙酮和乙醇等可作为有机氯农药污染土壤修复的首选。  相似文献   

12.
ABSTRACT

Although the appropriate supply of nutrients has been extensively researched, more information is required on the effects of nutrients in treating gaseous volatile organic compounds (VOCs) in biofiltration. In this study, the effects of phosphorous and trace metals on gaseous toluene and methyl ethyl ketone (MEK) removal were investigated. The transfer of nutrients from the irrigation liquid to the packed bed, and the consumption and holding amount of nutrients in the packing material were observed during biofiltration. Under conditions of 20–24 s of empty bed residence time, MEK removal was 95% or more in all conditions of the biofiltration reactors, whereas toluene removal was affected by the operating conditions of the reactors. Consumption ratio of phosphorus to carbon was from 1.7 × 10?4 to 1.1 × 10?3 in the steady state of VOC removal under the conditions of this study. When gaseous VOC treatment was restarted after nine days of shutdown, a significant decline in toluene removal was observed by the reactor in which phosphorus supply was approximately one fifth of the amount in another reactor. Two types of irrigation systems, soaking and spraying, were compared and soaking irrigation achieved a more even distribution of nutrients held inside the packed bed. Soaking irrigation was expected to lead to higher VOC removal capacity by this distribution effect of nutrients, but toluene removal in the reactor with this irrigation was lower than that in the reactor with spraying irrigation. One of the possible reasons for this was the inhibition of nutrients transfer in the bottom part of the reactor. The trend of transfer in all ingredients from the irrigation liquid to the packed bed was synchronized on the whole; however, this transfer relatively tended to be high in nitrate and sodium and low in ammonium and phosphate.

Implications: A major concern about using biofiltration systems to treat VOCs is the uncertainty regarding the appropriate nutrient supply to the filter bed to preserve microbial activity. This study showed that all the elements, except nitrogen, were retained sufficiently in the filter bed when a proper composition of nutrient solution was used for irrigation; however, phosphate addition may be needed when restarting a reactor from a prolonged period of shutdown. Distinct differences in the amount of transfer to the filter bed for different ingredients are probable, and may have to be taken into account when operating biofiltration reactors.  相似文献   

13.
Ethanol fuel production is growing rapidly in the rural Midwest, and this growth presents potential environmental impacts. In 2002, the U.S. Environmental Protection Agency (EPA) and the Minnesota Pollution Control Agency (MPCA) entered into enforcement actions with 12 fuel ethanol plants in Minnesota. The enforcement actions uncovered underreported emissions and resulted in consent decrees that required pollution control equipment be installed. A key component of the consent decrees was a requirement to conduct emissions tests for volatile organic compounds (VOCs) with the goal of improving the characterization and control of emissions. The conventional VOC stack test method was thought to underquantify total VOC emissions from ethanol plants. A hybrid test method was also developed that involved quantification of individual VOC species. The resulting database of total and speciated VOC emissions from 10 fuel ethanol plants is relatively small, but it is the most extensive to date and has been used to develop and gauge compliance with permit limits and to estimate health risks in Minnesota. Emissions were highly variable among facilities and emissions units. In addition to the variability, the small number of samples and the presence of many values below detection limits complicate the analysis of the data. To account for these issues, a nested bootstrap procedure on the Kaplan-Meier method was used to calculate means and upper confidence limits. In general, the fermentation scrubbers and fluid bed coolers emitted the largest mass of VOC emissions. Across most facilities and emissions units ethanol was the pollutant emitted at the highest rate. Acetaldehyde, acetic acid, and ethyl acetate were also important emissions from some units. Emissions of total VOCs, ethanol, and some other species appeared to be a function of the beer feed rate, although the relationship was not reliable enough to develop a production rate-based emissions factor.  相似文献   

14.
A suspended-growth bioreactor (SGB) was operated for the treatment of a gaseous stream mimicking emissions generated at a leather industrial company. The main volatile organic compounds (VOCs) present in the gaseous stream consisted of 1-methoxy-2-propanol, 2,6-dimethyl-4-heptanone, 2-butoxyethanol, toluene and butylacetate. A microbial consortium able to degrade these VOCs was successfully enriched. A laboratory-scale SGB was established and operated for 210-d with an 8h cycle period and with shutdowns at weekends. Along this period, the SGB was exposed to organic loads (OL) between 6.5 and 2.3 x 10(2) g h(-1) m(-3). Most of the compounds were not detected at the outlet of the SGB. The highest total VOC removal efficiency (RE) (ca 99%) was observed when an OL of 1.6 x 10(2) g h(-1) m(-3) was fed to the SGB. The maximum total VOC elimination capacity (1.8 x 10(2) g h(-1) m(-3)) was achieved when the OL applied to the SGB was 2.3 x 10(2) g h(-1) m(-3). For all the operating conditions, the SGB showed high levels of degradation of toluene and butylacetate (RE approximately equal to 100%). This study also revealed that recirculation of the gaseous effluent improved the performance of the SGB. Overall, the SGB was shown to be robust, showing high performance after night and weekend shutdown periods.  相似文献   

15.
Modeling variations of medium porosity in rotating drum biofilter   总被引:1,自引:0,他引:1  
Yang C  Chen H  Zeng G  Yu G  Liu X  Zhang X 《Chemosphere》2009,74(2):245-249
Rotating drum biofilters (RDBs) mounted with reticulated polyurethane sponge media has showed high removal efficiencies over a long period of time when used for volatile organic compound (VOC) removal. Due to the accumulation of biomass within the sponge medium, the porosity of a filter bed usually changes dynamically, which makes it difficult to predict and to control. In this paper, the porosity of a multi-layer RDB bed was investigated by a diffusion-reaction model in which biofilm growth and decay were taken into account at the pore scale of the sponge medium. Temporal and spatial changes of porosity were studied under various organic loadings and gas empty bed contact times (EBCTs). The porosity of the biofilter bed was assumed to be a function of biofilm thickness, and all the pores were assumed to be uniform. Toluene was selected as the model VOC. The model was solved using numerical methods through the MATLAB software. Results show that the porosity decreased with increased time of operation, increased toluene loading, or decreased gas EBCT value. The porosity in the outermost medium layer was less than that in the inner medium layers. Toluene removal efficiencies and porosities calculated from this model correlated with the experimental data well. Porosity variation was proposed to be an indicator for prediction of biofilter performance in biofilters as a consequence.  相似文献   

16.
以实际生活污水为处理对象,考察了传统进水/曝气和改良型分段进水的交替缺氧-好氧(A/O)2种运行模式对CAST工艺的快速启动及脱氮除磷性能稳定维持的影响。结果表明,传统进水/曝气运行模式下,系统达到最佳营养物去除性能所需启动时间30 d,稳定运行阶段TN平均去除80.66%,磷的去除率维持在66.30%左右;采用改良型交替运行模式,反应器达到稳定运行状态仅需18 d,系统稳定运行时TN平均去除81.36%,磷去除率稳定维持在90%以上,出水磷浓度在0.3 mg/L以下,出水水质达到国家污水综合排放标准一级A(GB8978-2002)。研究还发现,传统运行模式下,由低温引起的污泥沉降性能变差导致系统污泥严重流失,反应器几乎丧失污染物去除性能;而低温对交替运行模式下的反应器除磷性能几乎没有影响,总氮去除则因氨氮不完全硝化而大大降低。  相似文献   

17.
Zhao Y  Ren N  Wang A 《Chemosphere》2008,72(2):233-242
The roles of fermentative acidogenic bacteria and sulfate-reducing bacteria (SRB) in lactate degradation and sulfate reduction in a sulfidogenic bioreactor were investigated by traditional chemical monitoring and culture-independent methods. A continuously stirred tank reactor fed with synthetic wastewater containing lactate and SO(2-)(4) at 35 degrees C, 10h of hydraulic retention time was used. The results showed that sulfate removal efficiency reached 99%, and sulfide and acetate were the main end products after 20 d of operation. 16S rRNA gene based clone libraries and single-strand conformation polymorphism profiles demonstrated that the proportion of SRB increased from 16% to 95%, and that Desulfobulbus spp., Desulfovibrio spp., Pseudomonas spp. and Clostridium spp. formed a stable, dominant community structure. The decreasing COD/SO(2-)(4) ratio had little effect on the community pattern except that Pseudomonas spp. and Desulfobulbus spp. increased slightly. The addition of molybdate to the influent significantly changed the microbial community, sulfate removal efficiency and the pattern of end products. Clostridium spp., Bacteroides spp. and Ruminococcus spp. became the dominant community members. The main end products switched from acetate to ethanol and then to propionate with the oxidation-reduction potentials increasing from -420 to -290 mV. A lactate degradation pathway was deduced: lactate served as the electronic donor for Desulfovibrio spp., or was fermented by Clostridium spp. and Bacteroides spp. to produce propionate or ethanol, which were subsequently utilized by Desulfobulbus spp. and Desulfovibrio spp. The acidotrophic SRB oxidized part of the acetate finally.  相似文献   

18.
生物过滤塔处理实验室废气   总被引:1,自引:0,他引:1  
研究了生物过滤塔处理实验室排放的模拟混合废气,考察了反应器对苯、甲苯、二甲苯、乙醇、丙酮、乙酸乙酯和甲烷等废气的去除效果。运行结果表明,在设备稳定运行期间,进气中总挥发性有机物(TVOCs)的浓度为124~380 mg/m3,而出气浓度在10~40 mg/m3,去除效率保持在85%以上。实验室废气中的多种污染物在生物过滤塔中去除机理不同,亲水性污染物的去除效率高于疏水性污染物。通过系统关停后重启,污染物的去除效果在第2天就能恢复,这为生物过滤塔处理实验室废气过程的停运检修或者系统闲置提供了可行性。  相似文献   

19.
Characterization of compost biofiltration media.   总被引:5,自引:0,他引:5  
The effect of compost quality on performance of biofiltration media was investigated. Three types of compost media were characterized in terms of their key properties, including pH, total organic carbon (TOC) and nitrogen, moisture content, oxygen uptake rates and heterotrophic and fungal plate counts. Laboratory-scale biofilter columns were each filled with a different compost medium mixed with buffer and a bulking agent. The columns were operated with a volatile organic compound (VOC) mixture consisting of ethyl alcohol, butyraldehyde, ethyl acetate, and 1,1-diethoxybutane and subjected to various operating conditions. After 13 months, the columns were sampled and post-characterization of the media was performed. A mixture of biosolids/horse manure compost, which had a high initial microbial activity, had the shortest acclimation period. Best overall performance, however, was observed with yard waste compost, which was the most stable medium. Media hydrophobicity was a key factor in long-term performance. Significant changes in compost structure, moisture content, pH, volatile solids, oxygen uptake rates, and microbial population densities were observed over the course of the study. Analyses of organic nitrogen content showed that significant amounts of nitrogen were not depleted from the media.  相似文献   

20.
A detailed characterisation of the incoming wastewater and a performance evaluation were carried out for the domestic wastewater treatment plant of Erzincan City. Conventional characterisation results showed that Erzincan has a medium strength wastewater quality. Structural characterisation of the chemical oxygen demand (COD) indicated that the biodegradable fraction of the total COD was 64.7%. The soluble inert fraction was computed as 10.9% of the total COD. In Erzincan, an activated sludge plant provides secondary treatment using Carrousel treatment units. Because some operational problems, such as sludge bulking and foaming, have been experienced, and performance failures related to carbonaceous matter removal have been recorded many times, a new operational strategy suitable for this type of treatment plant was developed. In the new strategy, the sludge age was kept at 22 days, intermittent aeration was abandoned and replaced by continuous aeration, and the sludge recycle ratio was increased to 1.35 from 0.85. The developed operational strategy showed its merit in that previous operational problems largely disappeared and COD concentrations remained below the Turkish discharge limits of 100 mg/l and the NH4 removal rate was in the range 87–95%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏