首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This paper investigates the impacts of building facades and ground heating on the wind flow and pollutant transport in street canyons using the computational fluid dynamic (CFD) technique. Street canyons of H/W (H representing the building height and W the street width) varied from 0.1 to 2, which covered the basic flow regimes of skimming flow (H/W=1 or 2), wake interference flow (H/W=0.5), and isolated roughness flow (H/W=0.1), were examined in a series of sensitivity tests. Heating that occurred on different surfaces, including ground surface and building façades, posed considerable effects on the street canyon wind flow and pollutant transport compared with those under isothermal conditions. The CFD results showed that the mechanically induced wind flow and pollutant transport were complicated by the buoyancy under temperature stratification. Individual street canyons of different H/W and surface-heating scenarios exhibited their unique wind flow structure and pollutant transport behaviors. Two counter-rotating vortices were calculated in the street canyons of H/W=1, in which the zone of higher pollutant concentration under isothermal conditions was switched from the leeward side to the windward side. In the street canyon of H/W=2, the recirculating wind pattern was perturbed by surface heating that led to the development of either one primary vortex or three closely coupled vortices. Because of the complicated wind structure, the zones of higher pollutant concentration located either on the leeward or windward ground level were subjected to the surface-heating scenarios. Only two vortices were developed inside the street canyon of H/W=0.5. The large primary vortex, centered inside the street canyon, extended above the roof level of the street canyon. Meanwhile, a small secondary vortex was found at the ground-level windward corner whose size results as a function of surface-heating configurations. Finally, in the street canyon of H/W=0.1, an isolated clockwise-rotating vortex was developed beside the leeward building while the wind in the windward side blew in the prevailing wind direction. As a result, air pollutant emitted at the street centerline was unlikely to be carried into the leeward vortex. Instead, it was dispersed rapidly on the windward side before being removed from the street canyon.  相似文献   

2.
A validated LES model was employed to simulate the street canyons of aspect ratio (AR) 3, 5, and 10. Three, five, and eight vertically aligned primary recirculations were found for the three cases, respectively, which showed decreasing strength with decreasing height. The ground-level wind speeds were found to be very small, making it extremely difficult for the ground-level pollutants to disperse. Local maxima of turbulence intensities were found at the interfaces between the primary recirculations and the shear layer. The pollutant trajectory followed the primary recirculations. High pollutant concentration and variance were found near the buildings where wind flowed upward. Large gradients of pollutant concentration and variance were also observed at the interfaces between the primary recirculations and the shear layer. Detailed analyses of concentration budget showed that the advection terms were responsible for pollutant redistribution within primary recirculations, while the turbulent transport terms were responsible for pollutant penetration between primary recirculations as well as pollutant removal from the street canyon.  相似文献   

3.
Recent observations of air pollutant concentrations measured within and above street canyons were used to study the average vertical profiles of vehicular pollutant concentrations in the urban environment. The idea of an exponential vertical concentration distribution, exp( −Bzq), resulted from a near ground-level source diffusing over flat terrain, was tentatively extended to the urban street canyons, where the empirical parameters B and q are generally dependent on the atmospheric stability and the aerodynamic characteristics of the canyon.  相似文献   

4.
The objective of this study is to investigate the air ventilation impacts of the so called “wall effect” caused by the alignment of high-rise buildings in complex building clusters. The research method employs the numerical algorithm of computational fluid dynamics (CFD – FLUENT) to simulate the steady-state wind field in a typical Hong Kong urban setting and investigate pollutant dispersion inside the street canyon utilizing a pollutant transport model. The model settings of validation study were accomplished by comparing the simulation wind field around a single building block to wind tunnel data. The results revealed that our model simulation is fairly close to the wind tunnel measurements. In this paper, a typical dense building distribution in Hong Kong with 2 incident wind directions (0° and 22.5°) is studied. Two performance indicators are used to quantify the air ventilation impacts, namely the velocity ratio (VR) and the retention time (Tr) of pollutants at the street level. The results indicated that the velocity ratio at 2 m above ground was reduced 40% and retention time of pollutants increased 80% inside the street canyon when high-rise buildings with 4 times height of the street canyon were aligned as a “wall” upstream. While this reduction of air ventilation was anticipated, the magnitude is significant and this result clearly has important implications for building and urban planning.  相似文献   

5.
The mechanism of pollutant dispersion in idealized city models is investigated numerically by the introduction of a uniformly distributed pollutant source at street pedestrian level. We first study three short city forms with a single main street or two crossing streets, characterized by street length/street height ratios of L/H = 6 or 7 and a street height/street width ratio of H/W = 1, including a sharp-edged round city model, a smooth-edged round city model, and a sharp-edged square city model. For short city models with a single street and a parallel approaching wind, pollutant dilution mainly depends on the horizontal flow rate which decreases along the street. This decreasing rate is smallest for the smooth-edged round city model, which results in the lowest street concentrations. For city models with two crossing streets and the approaching wind parallel to the main street, the differences in overall city form result in different dispersion processes. For a sharp-edged round city model with two crossing streets, an approaching wind slightly non-parallel to the main street generates a lower pollutant concentration in the entire street volume. We also studied a sharp-edged round city model with one narrow street (L/H = 6; H/W = 6.7), finding that the uniformly distributed pollutants are transported from two street entries to the city centre, and are then removed out across the street roof. In contrast to the short city models we studied a single-street sharp-edged long rectangular city model (L/H = 21.7; H/W = 1) in which the horizontal flow rate remained nearly constant in a region far from the two entries. Within this region the turbulence across the street roof contributed more to the pollutant removal than vertical mean flows.  相似文献   

6.
A two-dimensional numerical model for simulating airflow and pollutant dispersion inside an urban street canyon was first developed using the FLUENT code, and then it was validated against a wind tunnel experiment. Then the effects of strength and position of pollutant sources on pollutant dispersion within an urban street canyon were investigated numerically. The numerical results showed that the dimensionless pollutant concentrations within the urban street canyon were independent from the source strength. The results also revealed that the pollutant distributions inside the urban street canyon with a two-lane road were influenced significantly by the positions of the two sources: 1) the closer the two sources were to the street center of the canyon, the lower the pollutant concentrations on the leeward wall and at the human respiration level in the leeward footpath became; 2) the pollutant concentrations on the windward wall and at the human respiration level in the windward footpath were not sensitive to the locations of the two sources as long as the source on the windward lane was situated outside the small recirculation zone at the bottom corner of the canyon windward wall; 3) the pollutant concentrations on the lower parts of the windward and leeward walls as well as in the two footpaths increased greatly when the two sources were moved from outside into the small recirculation zones.  相似文献   

7.
Reactive pollutant dispersion in an urban street canyon with a street aspect ratio of one is numerically investigated using a computational fluid dynamics (CFD) model. The CFD model developed is a Reynolds-averaged Navier–Stokes equations (RANS) model with the renormalization group (RNG) k–ε turbulence model and includes transport equations for NO, NO2, and O3 with simple photochemistry. An area emission source of NO and NO2 is considered in the presence of background O3 and street bottom heating (ΔT=5 °C) with an ambient wind perpendicular to the along-canyon direction. A primary vortex is formed in the street canyon and the line connecting the centers of cross-sectional vortices meanders over time and in the canyon space. The cross-canyon-averaged temperature and reactive pollutant concentrations oscillate with a period of about 15 min. The averaged temperature is found to be in phase with NO and NO2 concentrations but out of phase with O3 concentration. The photostationary state defect is small in the street canyon except for near the roof level and the upper downwind region of the canyon and its local minimum is observed near the center of the primary vortex. The budget analysis of NO (NO2) concentration shows that the magnitude of the advection or turbulent diffusion term is much larger (larger) than that of the chemical reaction term and that the advection term is largely balanced by the turbulent diffusion term. On the other hand, the budget analysis of O3 concentration shows that the magnitude of the chemical reaction term is comparable to that of the advection or turbulent diffusion term. The inhomogeneous temperature distribution itself affects O3 concentration to some extent due to the temperature-dependent photolysis rate and reaction rate constant.  相似文献   

8.
For the first time until now, the results from a prediction model (Atmospheric Dispersion Modelling System (ADMS)-Road) of pollutant dispersion in a street canyon were compared to the results obtained from biomonitors. In particular, the instrumental monitoring of particulate matter (PM10) and the biomonitoring of 14 polycyclic aromatic hydrocarbons (PAHs) and 11 metals by Quercus ilex leaves and Hypnum cupressiforme moss bags, acting as long- and short-term accumulators, respectively, were carried out. For both PAHs and metals, similar bioaccumulation trends were observed, with higher concentrations in biomonitors exposed at the leeward canyon side, affected by primary air vortex. The major pollutant accumulation at the leeward side was also predicted by the ADMS-Road model, on the basis of the prevailing wind direction that determines different exposure of the street canyon sides to pollutants emitted by vehicular traffic. A clear vertical (3, 6 and 9 m) distribution gradient of pollutants was not observed, so that both the model and biomonitoring results suggested that local air turbulences in the street canyon could contribute to uniform pollutant distribution at different heights.  相似文献   

9.
This paper is concerned with the motion of air within the urban street canyon and is directed towards a deeper understanding of pollutant dispersion with respect to various simple canyon geometries and source positions. Taking into account the present days typical urban configurations, three principal flow regimes “isolated roughness flow”, “skimming flow” and “wake interference flow” (Boundary Layer Climates, 2nd edition, Methuen, London) and their corresponding pollutant dispersion characteristics are studied for various canopies aspect ratios, namely relative height (h2/h1), canyon height to width ratio (h/w) and canyon length to height ratio (l/h). A field-size canyon has been analyzed through numerical simulations using the standard k-ε turbulence closure model. It is found that the pollutant transport and diffusion is strongly dependent upon the type of flow regime inside the canyon and exchange between canyon and the above roof air. Some rules of thumbs have been established to get urban canyon geometries for efficient dispersion of pollutants.  相似文献   

10.
This paper is concerned with the motion of air within the urban street canyon and is directed towards a deeper understanding of pollutant dispersion with respect to various simple canyon geometries and source positions. Taking into account the present days typical urban configurations, three principal flow regimes “isolated roughness flow”, “skimming flow” and “wake interference flow” (Boundary Layer Climates, 2nd edition, Methuen, London) and their corresponding pollutant dispersion characteristics are studied for various canopies aspect ratios, namely relative height (h2/h1), canyon height to width ratio (h/w) and canyon length to height ratio (l/h). A field-size canyon has been analyzed through numerical simulations using the standard k-ε turbulence closure model. It is found that the pollutant transport and diffusion is strongly dependent upon the type of flow regime inside the canyon and exchange between canyon and the above roof air. Some rules of thumbs have been established to get urban canyon geometries for efficient dispersion of pollutants.  相似文献   

11.
In this study, numerical modelling of the flow and concentration fields has been undertaken for a deep street canyon in Naples (Italy), having aspect ratio (i.e. ratio of the building height H to the street width W) H/W = 5.7. Two different modelling techniques have been employed: computational fluid dynamics (CFD) and operational dispersion modelling. The CFD simulations have been carried out by using the RNG k? turbulence model included in the commercial suite FLUENT, while operational modelling has been conducted by means of the WinOSPM model. Concentration fields obtained from model simulations have been compared with experimental data of CO concentrations measured at two vertical locations within the canyon. The CFD results are in good agreement with the experimental data, while poor agreement is observed for the WinOSPM results. This is because WinOSPM was originally developed and tested for street canyons with aspect ratio H/W ≌ 1. Large discrepancies in wind profiles simulated within the canyon are observed between CFD and OSPM models. Therefore, a modification of the wind profile within the canyon is introduced in WinOSPM for extending its applicability to deeper canyons, leading to an improved agreement between modelled and experimental data. Further development of the operational dispersion model is required in order to reproduce the distinct air circulation patterns within deep street canyons.  相似文献   

12.
NOx and NO2 concentrations were measured at different locations in a city centre of an urban zone (Population 450 000) in order to study the variation of the outdoor exposure at pedestrian level. These measurements were carried out to understand the influence of traffic emissions at each measured site. The observations were done during four weeks in winter, including several days with high pollution levels. The results at different locations have been used to analyse criteria recommended for locating observation sites in a monitoring network. No large differences in background pollution averaged over several weeks have been found throughout the city centre, even during pollution peaks. Measurements were also carried out inside one street canyon. The contribution of the street traffic to the NO=NOx−NO2 concentrations observed at side-walk has been found important, i.e., several times the background level. On the other hand, the majority of observed NO2 pollution is due to the contribution of background pollution within the street. The pollutant excess at pedestrian level is strongly correlated to the street traffic emission and to the atmospheric turbulence observed at roof level. Application of a box model to the street data demonstrates that such models can be useful to estimate the pollutant accumulation within the street.  相似文献   

13.
A two-dimensional numerical model for evaluating the wind flow and pollutant dispersion within a street canyon was first developed using the FLUENT code, which was then validated against a wind tunnel experiment. Then, the effects of the upstream building width and upwind building arrangement on the airflow and pollutant dispersion inside an isolated street canyon were investigated numerically. The numerical results revealed that: (1) the in-canyon vortex center shifts downwards as the upstream building width increases; (2) the recirculation zone covers the entire upstream building roof for the cases when W/H = 0.5, 1.0, 1.5, and 2.0 (W is the upstream building width and H is the building height), whereas the flow reattaches the upstream building roof for the cases when W/H = 2.5 and 3.0; (3) when the upstream building width is shorter than the critical width WC (= 2H), an increase in the upstream building width leads to an increase in the pollution level on the leeward wall of the canyon and a decrease in the roof-level concentrations at the upstream building; (4) when the upstream building width is longer than the critical width, the roof-level concentrations at the upstream building are negligibly small and the pollution level on the leeward wall of the canyon is almost unaffected by a further increase in the upstream building width; (5) when the buildings are placed upwind of the canyon, the flow attaches the upstream building roof and, therefore, almost none of the pollutants are distributed on the upstream building roof; and (6) the pollution levels inside the canyon and on the downstream building roof increase significantly with the number of upwind buildings.  相似文献   

14.
A large eddy simulation (LES) model that accounts for chemical reactions between oxides of nitrogen and ozone has been used to investigate the effect of local shading within an idealised street canyon on pollutant concentrations. It has shown that local shading can have a substantial impact on kerbside concentrations (>6 ppb difference for some situations presented) and that this may need to be taken into account to set up numerical model runs as well as sampling sites. A sensitivity study has been performed to investigate the effect of various governing parameters. A strong influence was found for the actual reduction of the photolytic rate constant within the shaded areas. A near linear relationship appeared between the reduction and the effect on pollutant concentrations. The chemical regime above and within the street canyon (determined by background concentrations aloft and emission rates at the ground) was also shown to be of high importance. The geometrical layout of the shading within the canyon and the wind speed in the canyon was shown to affect the spatial distribution of the shading effect rather than its overall magnitude.  相似文献   

15.
Due to heavy traffic emissions within an urban environment, air quality during the last decade becomes worse year by year and hazard to public health. In the present work, numerical modeling of flow and dispersion of gaseous emissions from vehicle exhaust in a street canyon were investigated under changes of the aspect ratio and wind direction. The three-dimensional flow and dispersion of gaseous pollutants were modeled using a computational fluid dynamics (CFD) model which was numerically solved using Reynolds-averaged Navier–Stokes (RANS) equations. The diffusion flow field in the atmospheric boundary layer within the street canyon was studied for different aspect ratios (W/H?=?1/2, 3/4, and 1) and wind directions (θ?=?90°, 112.5°, 135°, and 157.5°). The numerical models were validated against wind tunnel results to optimize the turbulence model. The numerical results agreed well with the wind tunnel results. The simulation demonstrated that the minimum concentration at the human respiration height within the street canyon was on the windward side for aspect ratios W/H?=?1/2 and 1 and wind directions θ?=?112.5°, 135°, and 157.5°. The pollutant concentration level decreases as the wind direction and aspect ratio increase. The wind velocity and turbulence intensity increase as the aspect ratio and wind direction increase.  相似文献   

16.
The dispersion model, ADMS-Urban, alongside the statistical modelling technique, generalized additive modelling, have been used to predict hourly NOx and nitrogen dioxide (NO2) concentrations at a busy street canyon location and the results compared with measurements. Generalized additive models (GAMs) were constructed for NO2 and NOx concentrations using input data required to run ADMS-Urban. Bivariate polar plots have been produced from the wind flow (speed and direction) and pollution data (measured and predicted concentrations) to provide further information regarding the complex wind-pollutant interactions in an urban street canyon. The predictions made with the GAMs show excellent agreement with measured concentrations at this location, reproducing both the magnitude of NOx and NO2 concentrations and also the wind speed-wind direction dependence of pollutant sources within the canyon. However, the predictions made with ADMS-Urban under-estimated the measured NOx by 11% and NO2 by 21% and there are clear differences in the bivariate polar plots. Several sensitivity tests were carried out with ADMS-Urban in an attempt to produce predictions in closer agreement to those measured at Gillygate. Increasing the primary NO2 fraction in ADMS-Urban (from 10% to 20%) had a considerable effect on the predictions made with this model, increasing NO2 predictions by ∼20%. However, the bivariate plots still showed major differences to those of the measurements. This work illustrates that generalized additive modelling is a useful tool for investigating complex wind-pollutant interactions within a street canyon.  相似文献   

17.
Concentrations and turbulent fluxes of accumulation mode particles were measured during the 2004–2005 ‘Canopy and Aerosol Particle Interaction in Toulouse Urban Layer’ project (CAPITOUL) at the top of two intersecting street canyons and in the urban boundary layer (UBL) in Toulouse, France. Particle numbers were strongly affected by boundary layer depth and showed limited sensitivity to local emissions. Differences in the diurnal patterns of particle numbers were observed between the finer fraction (0.3–0.4 μm) and coarser fraction (1.6–2.0 μm) of accumulation mode particles, indicating different processes of formation, evolution and transportation may be dominant. Highest particle numbers were observed in the narrow street canyon which had more limited local emissions and comparatively small particle fluxes. However, the improved ventilation rate in the wider canyon was also associated with the downward mixing of particles into the street canyon from the UBL. The results from this study clearly illustrate the temporal and spatial variability of particle numbers and fluxes in the urban atmosphere.  相似文献   

18.
This study presents a comparison between measured and modelled particle number concentrations (PNCs) in the 10–300 nm size range at different heights in a canyon. The PNCs were modelled using a simple modelling approach (modified Box model, including vertical variation), an Operational Street Pollution Model (OSPM) and Computational Fluid Dynamics (CFD) code FLUENT. All models disregarded any particle dynamics. CFD simulations have been carried out in a simplified geometry of the selected street canyon. Four different sizes of emission sources have been used in the CFD simulations to assess the effect of source size on mean PNC distributions in the street canyon. The measured PNCs were between a factor of two and three of those from the three models, suggesting that if the model inputs are chosen carefully, even a simplified approach can predict the PNCs as well as more complex models. CFD simulations showed that selection of the source size was critical to determine PNC distributions. A source size scaling the vehicle dimensions was found to better represent the measured PNC profiles in the lowest part of the canyon. The OSPM and Box model produced similar shapes of PNC profile across the entire height of the canyon, showing a well-mixed region up to first ≈2 m and then decreasing PNCs with increased height. The CFD profiles do correctly reproduce the increase from road level to a height of ≈2 m; however, they do not predict the measured PNC decrease higher in the canyon. The PNC differences were largest between idealised (CFD and Box) and operational (OSPM) models at upper sampling heights; these were attributed to weaker exchange of air between street and roof-above in the upper part of the canyon in the CFD calculations. Possible reasons for these discrepancies are given.  相似文献   

19.
ABSTRACT

The aim of this paper is to show that a photochemical box model could describe the air pollution diurnal profiles within a typical street canyon in the city of Athens. As sophisticated three-dimensional dispersion models are computationally expensive and they cannot serve to simulate pollution levels in the scale of an urban street canyon, a suitably modified three-layer photochemical box model was applied. A street canyon of Athens with heavy traffic was chosen to apply the aforementioned model. The model was used to calculate pollutant concentrations during two days with meteorological conditions favoring pollutant accumulation. Road traffic emissions were calculated based on existing traffic load measurements. Meteorological data, as well as various pollutant concentrations, in order to compare with the model results, were provided by available measurements. The calculated concentrations were found to be in good agreement with measured concentration levels and show that, when traffic load and traffic composition data are available, this model can be used to predict pollution episodes. It is noteworthy that high concentrations persisted, even after additional traffic restriction measures were taken on the second day because of the high pollution levels.  相似文献   

20.
A two-dimensional, steady, kε turbulence model was used to investigate the high Reynolds number skimming flow field of an urban street canyon. We describe the critical canyon width-to-height ratios that distinguish a cascade of vortex patterns that form in an urban street canyon. Details of the flow field are reported that includes the structure of the mean flow field, turbulent kinetic energy, turbulent length scale, turbulent eddy viscosity, and Reynolds stress for three typical different aspect ratios, W/H, of a street canyon. The consequences of vortex layering on vertical transport are explored.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏