首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 134 毫秒
1.
生物三相流化床处理COD废水工艺条件研究   总被引:2,自引:0,他引:2  
采用生物三相流化床处理含Cu-COD废水,研究了载体的选择和生物挂膜条件、及废水停留时间、容积负荷、气水比、温度和pH值等工艺条件与COD去除率的关系。结果表明,在控制适宜条件下,对于含Cu2~3mg/l,COD 1500~2500mg/l的染化行业废水,采用生物流化床法处理,排放水Cu可达0.52~0.82mg/l,COD为145~175mg/l,COD去除率可达92%~93%。  相似文献   

2.
聚醚废水处理工艺研究   总被引:3,自引:0,他引:3       下载免费PDF全文
研究了中和混凝-厌氧十好氧-生物活性炭组合工艺,在不同工况和运行参数条件下处理聚醚废水的效果.结果表明,中和混凝能有效地降低生物处理的污泥负荷,调节pH值6.7,聚合氯化铝的投加量为l00mg/L时.聚醚废水COD去除率可达28%,当进水的COD为3000~4000mg/L时,聚醚废水经此组合工艺处理后,COD的总去除率达96%以上,出水COD值约150mg/L.  相似文献   

3.
本文报导采用生物厌氧消化和好氧净化处理相结合的生物系统工程处理屠宰废水的试验,在常温(25±1℃)条件下,厌氧进水COD2200-2500mg/L,厌氧一级处理采用UASB生物反应器,HRT8h,有机负荷平均6.95kgCOD/m~3·d,其COD去除率70~80%,产气率为1.2~1.3L/L·d,CH_4含量平均60%以上;经厌氧——好氧联合试验处理,其COD总去除率可达90%以上,出水COD≤200mg/L。  相似文献   

4.
采用网捕凝聚法对含Cu为1730~3820mg/l、COD为3984~5480mg/l的有机络合铜废水的处理工艺条件进行了研究。经实验室放大试验表明,在严格控制pH7.0~7.5条件下,加入凝聚剂生成絮体晶核来实现网捕凝聚,可使出水中铜为0.2~2.0mg/l,然后采用生物流化床对此废水进行生物降解,可使排放水中铜和COD达到或接近排放标准。  相似文献   

5.
生化-氧化偶合絮凝法处理含季铵盐高浓度有机工业废水   总被引:1,自引:0,他引:1  
采用厌氧-好氧-氧化偶合絮凝工艺处理特种有机废水,研究了在不同运行参数条件下处理废水的效果。结果表明,在进水COD为2500~3000mg/L范围内,经厌氧-二级好氧处理,COD总去除率可达95%,再通过氧化偶合絮凝处理,出水COD可降至80mg/L以下,COD总去除率可高达97%以上,达到工业废水排放标准。   相似文献   

6.
不锈钢-铝电极电絮凝处理含铜废水的试验研究   总被引:2,自引:0,他引:2  
采用不锈钢-铝为电极的电絮凝法对含铜废水进行了处理试验研究,模拟废水铜离子浓度为150 mg/L,以废水中的铜离子浓度和COD去除率为考察指标,在电流密度为15 mA/cm2、极板间距为3 cm、pH值为7、电解时间为120 min的条件下,Cu2+的去除率平均能达到99%以上,COD的去除率亦能达到97%;在此基础上,应用于实际的电路板腐蚀液废水的处理试验,发现Cl-浓度在200 mg/L以上时,对废水先进行相关预处理也能达到较好的处理效果,该研究对进一步探讨Cl-对电絮凝的影响机理有一定的借鉴意义。  相似文献   

7.
用厌氧酸化预处理焦化废水的研究   总被引:9,自引:0,他引:9  
在采用色谱-质谱(GC/MS)联用仪分析北京焦化厂废水中有机物组分及浓度的基础上,研究厌氧酸化对焦化废水可生物处理性能的影响,并探讨厌氧酸化作为焦化废水好氧生物处理预处理的可行性。试验结果表明,焦化废水经6h厌氧酸化,12h好氧曝气,COD去除率可达90%以上,比未用厌氧酸化预处理的COD去除率提高近40%。当焦化废水进水COD为1780mg/l时,出水COD可降至158mg/l。  相似文献   

8.
针对印刷线路板综合废水p H低,Cu、Ni、氨氮含量高等特点,采用铁碳催化内电解结合A/O组合工艺进行废水处理。最佳条件下,一级催化内电解对总铜去除率可达99.6%,由179.7 mg/L降低至0.71 mg/L;对总镍去除率为62.7%,由0.83 mg/L降至0.31 mg/L。二级催化内电解对总铜去除率达96.3%,降低至0.026 mg/L;对总镍去除率达92.6%,降低至0.023 mg/L。两级铁碳内电解对COD和TP去除率为53.3%和91.2%。经过A/O系统处理后,最终出水ρ(COD)<44 mg/L、ρ(TP)<0.21 mg/L、ρ(TN)<14 mg/L、ρ(NH+4-N)<1.6 mg/L、ρ(总铜)<0.02 mg/L、ρ(总镍)<0.016 mg/L,可达到GB 18918—2002《城镇污水处理厂污染物排放标准》一级A标准。  相似文献   

9.
采用臭氧催化剂联合处理养猪场废水,通过试验得到最佳工艺参数。在最佳试验条件下,进水COD为9500 mg/L,氨氮为1488 mg/L,经处理后出水COD平均去除率为96.1%,氨氮去除率为95%,各项主要指标可达GB18596-2001畜禽业养殖污染物排放标准。  相似文献   

10.
二氧化氯催化氧化处理酸性深绿B染料废水研究   总被引:2,自引:0,他引:2  
本文对二氧化氯化学氧化体系和二氧化氯催化氧化体系处理酸性深绿B染料废水进行了试验研究,结果表明:单用二氧化氯化学氧化体系处理COD为840 mg/L的酸性深绿B染料废水时,最佳反应pH值为1,氧化剂经济用量为1 500 mg ClO2/L废水,反应时间为60 min,COD去除率可达52%左右;当采用二氧化氯与自制催化...  相似文献   

11.
焦化废水生物流化床系统脱氮中试研究   总被引:6,自引:0,他引:6  
杨平  王彬  石炎福 《环境工程》2002,20(4):14-17
以厌氧流化床、缺氧流化床作生物反应器 ,聚合物多孔高分子颗粒作微生物固定化载体 ,采用厌氧 缺氧 好氧工艺进行了焦化废水处理中试研究。结果表明 :当系统稳定运行时 ,进水NH3 N、CODCr、酚平均浓度为 5 39 5mg L、14 88mg L、2 4 7 7mg L时 ,出水NH3 N、CODCr酚平均浓度分别为 14 3mg L、2 5 2 4mg L、0 2mg L ;厌氧流化床、缺氧流化床反应器中存在厌氧氨氧化反应 ,在这 2个阶段NH3 N分别去除 9 8%和 3 3%。该生物流化床系统脱氮技术对现有焦化废水活性污泥法处理系统的改造具有指导意义  相似文献   

12.
以含铜废水为处理对象,将流化床和固定床两种诱导结晶反应器进行对比试验。结果表明:当进水含铜浓度为20 mg/L时,流化床反应器出水含铜量为0~2 mg/L,出水含铜量在0~11 mg/L;利用SEM-EDS可以发现,流化床形成的结晶产物生长致密、晶形明确、产物纯度高,固定床形成的结晶产物在载体表面分布不均、结构疏松,纯度较低。  相似文献   

13.
三相生物流化床处理高浓度丙烯酸丁酯生产废水   总被引:1,自引:1,他引:0  
采用三相生物流化床工艺处理模拟丙烯酸丁酯生产废水,考察了进水丙烯酸浓度、对甲基苯磺酸浓度、容积负荷、水力停留时间对废水处理效果的影响.结果表明,该工艺适合于丙烯酸丁酯废水的高负荷处理.进水中100 mg/L丙烯酸及50 mg/L的对甲基苯磺酸对生物流化床中未经驯化的微生物具有明显的毒害作用,经过2周左右的驯化,毒害作用...  相似文献   

14.
A new anaerobic reactor, Jet-loop anaerobic fluidized bed (JLAFB), was designed for treating high-sulfate wastewater. The treatment characteristics, including the effect of influent COD/SO42 ratio and alkalinity and sulfide inhibition in reactors, were discussed for a JLAFB and a general anaerobic fiuidized bed (AFB) reactor used as sulfate-reducing phase and methane-producing phase, respectively, in two-phase anaerobic digestion process. The formation of granules in the two reactors was also examined. The results indicated that COD and sulfate removal had different demand of influent COD/SO4^2- ratios. When total COD removal was up to 85%, the ratio was only required up to 1.2, whereas, total sulfate removal up to 95% required it exceeding 3.0. The alkalinity in the two reactors increased linearly with the growth of influent alkalinity. Moreover, the change of influent alkalinity had no significant effect on pH and volatile fatty acids (VFA) in the two reactors. Influent alkalinity kept at 400-500 mg/L could meet the requirement of the treating process. The JLAFB reactor had great advantage in avoiding sulfide and free-H2S accumulation and toxicity inhibition on microorganisms. When sulfate loading rate was up to 8. 1 kg/(m^3.d), the sulfide and free-H2S concentrations in JLAFB reactor were 58.6 and 49.7 mg/L, respectively. Furthermore, the granules, with offwhite color, ellipse shape and diameters of 1.0-3.0 mm, could be developed in JLAFB reactor. In granules, different groups of bacteria were distributed in different layers, and some inorganic metal compounds such as Fe, Ca, Mg etc. were found.  相似文献   

15.
实验采用Fenton反应-中和-厌氧菌法处理某高盐度工业废水,考察了各因素对COD去除率的影响。实验结果表明,Fenton反应处理该工业废水的最佳条件是:n(H2O2):n(COD)=2:1,n(H2O2):n(Fe2+)=4:1,pH=3,反应时间采用120 min。Fenton处理后废水COD由24 230 mg/L下降到13 020 mg/L,去除率达到46.26%;所得反应液用Ca(OH)2中和沉淀后COD值降低到11 060 mg/L,去除率为15.05%;最后废水经稀释后进行厌氧菌降解处理,COD为1 625 mg/L的废水经厌氧菌6天处理后降为466 mg/L,去除率为71.32%,达到GB8978-1996中规定的COD三级排放标准。  相似文献   

16.
硫酸盐生物还原法处理含锌废水   总被引:19,自引:1,他引:18  
研究了用硫酸盐还原菌处理含锌废水的污泥床工艺及影响运行的主要因素,结果表明,该工艺可在进水COD和锌浓度分别为320mg/L与100mg/L时有效运行,有机物和Zn^2+的去除率分别以73.8%和99.63%,大水力滞留时间降至6h时,Zn^2+的去除率仍可达94.55%,进水Zn^2+浓度低于500mg/L,时装置可以稳定运行,而当浓度达到600mg/L时,硫酸盐原菌受到Zn^2+的明显毒害。当  相似文献   

17.
膜生物反应器处理毛纺废水的中试研究   总被引:30,自引:2,他引:28  
采用中试规模(10t/d)的厌氧-好氧膜生物反应器(A/O MBR)处理毛纺印染废水.当HRT为7h,进水COD、BOD5分别为179~358mg/L和44.8~206mg/L,试验系统对COD、BODs、色度、浊度的平均去除率分别为92.1%、98.4%、60.7%、98.9%,出水水质浓度或指标值分别为20.2mg/L、1.6mg/L、25倍、0.51 NTU.出水水质指标达到建设部生活杂用水水质标准(CJ25.1-89).A/O MBR工艺处理毛纺印染废水技术可行、操作简单、易于管理,可为工业规模应用提供技术参考.  相似文献   

18.
尝试一种新型结构的生物三相流化床工程化应用于磁电器制品厂的洗涤废水和漂染厂高浓度印染废水的处理 ,处理规模分别为 2 40m3 d和 2 5 0 0m3 d。采用A O2 的流化床组合工艺 ,在总HRT低于 2 4h的操作条件下 ,当洗涤废水进水CODCr负荷为 2 3~ 2 6kg m3·d ,BOD5负荷为 0 72~ 0 95kg m3·d的情况下 ,出水CODCr、BOD5、SS及油分的平均浓度分别为 43 5 0mg L、18 90mg L、2 1 0mg L及 0 86mg L。当印染废水的进水CODCr、BOD5负荷为 3 8~5 8kg m3·d和 1 3~ 1 8kg m3·d时 ,出水CODCr、BOD5浓度分别低于 90mg L和 35mg L。其处理出水均达到了国家一级排放标准。选用的新工艺运行管理方便 ,出水稳定 ,处理费用为 0 6~ 0 8元 t,且基本无污泥产生 ,证明该技术符合清洁生产的环保新概念。实践证明 ,新型生物三相流化床具有体积负荷大 ,抗冲击能力强 ,处理效率高的特点  相似文献   

19.
以固定化微藻颗粒为原料,通过搭建流化床反应器强化微藻对氨氮(NH4+-N)的去除,设计了藻种、污水上升流速、光周期和光照强度四组单一变量实验,系统地研究了不同条件下微藻去除NH4+-N的能力.结果表明,当以固定化斜生栅藻为原料、污水上升流速为6.8m/h、光周期为8:16h和光照强度为4800Lux时,NH4+-N去除效果最优(96.7%).在最优操作条件下,探究了COD为200mg/L时微藻去除NH4+-N的潜力,结果表明,当NH4+-N初始浓度不高于50mg/L时,NH4+-N去除率高于95%.本实验建立了一套半连续微藻流化床实验方法,该方法显著减弱了微藻在生物同化过程中对有机碳源的依赖性,为低COD条件下微藻生物脱氮工艺的设计提供了技术参考和理论基础.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号