首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
利用厌氧反应器与好氧MBR组合工艺处理印染废水,探讨了水力停留时间(HRT)对其处理效果的影响.结果表明,在溶解氧(DO)浓度为1.8~2.6mg/L的条件下,HRT为7.5、4.5和2.5h时,反应器对COD的去除效率分别为88.7%~96.5%、87.3%~97.2%和81%~92%,出水COD的浓度分别为78.9~51.2,81.6~50.8,93.4~65.8mg/L.试验同时考察了不同HRT条件下,活性污泥浓度(MLSS)对COD去除率的影响.结果表明,在试验条件下,本工艺中一体化膜生物反应器中最佳污泥浓度应控制在6500mg/左右.  相似文献   

2.
AMBBR工艺处理城市污水   总被引:1,自引:0,他引:1  
袁辉洲  邹原  张鹏  朱佳 《环境工程》2012,30(1):30-34,82
通过对厌氧移动床生物膜反应器处理南方热带亚热带地区城市生活污水的试验研究,采用好氧-厌氧两个阶段进行挂膜试验以缩短挂膜时间,探讨了水力停留时间(HRT)、pH值、填料填充率对反应器处理效果的影响。试验结果表明:在HRT为12 h,进水ρ(COD)为300 mg/L,ρ(氨氮)为15 mg/L,50%的填料填充率,pH=7的工艺条件下,装置对COD去除率为51.2%,对氨氮去除率为40.8%,对TN去除率为38.1%。  相似文献   

3.
对气提反应器处理生活污水进行了试验研究,探讨了生物膜的形成和水力停留时间及曝气量时中低浓度生活污水处理效果的影响.结果表明:最优条件是在HRT为6h,曝气量为0.6 m3/h,进水COD和NH4+-N质量浓度分剐为240.2~298.7 mg/L和29.1~68.9 mg/L条件下,平均COD去除率为83%,NH4+-N去除率为95.1%.  相似文献   

4.
为提高煤矿生活污水脱氮效果并优化反应方式,采用限氧曝气生物膜反应器进行试验研究,分析了污染物去除效果和主要影响因素。结果表明:在第一反应室DO为1.5~2 mg/L、第二反应室DO为1~1.5 mg/L、HRT为3.13 h、ρ(COD)=69.8~85.2 mg/L、ρ(NH4+-N)=14. 6~17.9 mg/L、ρ(TN)=17.3~21.2 mg/L的进水条件下,反应器出水COD、NH4+-N、TN最大质量浓度分别为18.3 mg/L、0.23 mg/L和8.92 mg/L,平均去除率分别为80.8%、99.3%和59.3%,同步硝化反硝化效率(SND率)为45.4%~56.5%;在2.78 h≤HRT≤4.17 h范围内,反应器出水COD和NH4+-N浓度达到GB 3838—2002Ⅲ类标准要求,出水ρ(TN)10 mg/L且SND率达到52%。  相似文献   

5.
针对制革综合废水有机污染浓度高的特点,采用厌氧折流板反应器(ABR)-曝气生物滤池(BAF)新工艺处理,试验研究了ABR和BAF的启动以及水力停留时间(HRT)、有机负荷及其他因素对处理效果的影响。试验结果表明:ABR在HRT为12 h、水温25~37℃,BAF在HRT为2.5 h、DO≥2.0 mg/L的条件下,组合工艺对制革综合废水的COD平均去除率达88%,出水COD、SS、色度、总铬等指标达DB 44/26—2001《广东省地方标准水污染物排放限值》一级标准。  相似文献   

6.
膜生物反应器处理毛纺废水的中试研究   总被引:30,自引:2,他引:28  
采用中试规模(10t/d)的厌氧-好氧膜生物反应器(A/O MBR)处理毛纺印染废水.当HRT为7h,进水COD、BOD5分别为179~358mg/L和44.8~206mg/L,试验系统对COD、BODs、色度、浊度的平均去除率分别为92.1%、98.4%、60.7%、98.9%,出水水质浓度或指标值分别为20.2mg/L、1.6mg/L、25倍、0.51 NTU.出水水质指标达到建设部生活杂用水水质标准(CJ25.1-89).A/O MBR工艺处理毛纺印染废水技术可行、操作简单、易于管理,可为工业规模应用提供技术参考.  相似文献   

7.
EGSB反应器处理链霉素有机废水工业性试验研究   总被引:4,自引:0,他引:4  
本文介绍了在厌氧中温发酵 (35± l℃ )条件下 ,采用膨胀颗粒污泥床 (EGSB)反应器日处理 2 0 0 t链霉素有机废水的工业性试验研究。试验结果表明 :在控制低浓度进料 ,COD在 2 0 0 0~ 70 0 0 mg/L、COD/SO2 - 4=7~ 1 0的条件下 ,有效地降低了毒性物质的抑制作用 ,使反应器成功启动并培养出颗粒污泥 ;当进料 COD在 70 0 0~ 1 30 0 0 mg/L,HRT为 3~ 5h,p H值为 6.8~ 7.2时 ,COD去除率可达75% ,反应器容积负荷最高可达 1 5.8kg COD/(m3.d) ,而 SO2 - 4去除率可有效地控制在 60 %~ 70 % ,实现了 EGSB反应器对链霉素废水中有机物和硫酸盐的有效去除。  相似文献   

8.
SBR反应器内短程硝化系统快速启动及影响因素研究   总被引:7,自引:0,他引:7  
探讨了采用序批式反应器(SBR)快速启动自养短程硝化系统的方法,研究了溶解氧(DO)、pH、温度、外加有机碳源对自养短程消化系统的影响。以硝化污泥接种反应器(SBR),在纯自养条件下利用高浓度溶解氧1.0~1.6mg/L和中温(35±1)℃达到亚硝酸氮的快速积累。结果表明,在进水氨氮浓度为280~300mg/L,HRT为12h,控制pH值为7.5~8.5、温度在(28±1)℃、溶解氧浓度为0.8~1.2mg/L条件下,氨氮去除率达到90%以上,亚硝酸氮积累率高达95%。试验证明投加有机碳源(COD)50mg/L左右时,不会对短程硝化系统产生影响,且能实现较高氨氮去除率和稳定的亚硝酸氮积累率。  相似文献   

9.
常温下内循环厌氧反应器的启动研究   总被引:1,自引:0,他引:1  
宋倩  马邕文 《环境工程》2010,28(1):14-16
研究了内循环厌氧反应器(IC反应器)在常温下处理葡萄糖配水的启动特性。结果表明:在运行温度为25~35℃的条件下,反应器经70 d启动完成,且IC反应器具有较好的处理效果,反应器内能形成大量的颗粒污泥。启动完成后,进水COD浓度在3 000 mg/L左右时,COD去除率一直保持在95%以上,出水COD浓度维持在200 mg/L左右。当HRT为5.8 h,容积负荷为11.9 kg/(m3.d)时,出水VFA低于200 mg/L,产气量为33 L/d,反应器运行正常。  相似文献   

10.
内循环移动床生物膜反应器的研究与应用   总被引:2,自引:0,他引:2  
对传统移动床生物膜反应器进行改进,开发了内循环移动床生物膜反应器,通过处理模拟生活污水的研究,考察了反应器去除有机物和脱氮的能力。结果表明,在填料投加率为35%、进水COD为200~800mg/L、HRT为6h、有机负荷为0.8~3.2kg/(m.3d)的条件下,系统COD的去除率在89%以上;同时反应器具有良好的同步硝化反硝化脱氮能力,在DO为2.0mg/L、C/N为25、HRT为6h的条件下,NH4-N和TN的平均去除率分别可以达到98%和93%。另外,内循环移动床生物膜反应器与移动床生物膜反应器的对比实验结果表明,前者对COD和氮的去除效果都优于后者。  相似文献   

11.
膜生物反应器处理高浓度含酚废水研究   总被引:1,自引:0,他引:1  
将膜生物反应器(MBR)用于高浓度含酚废水的处理中,探讨了进水中苯酚浓度、水力停留时间和污泥浓度对膜生物反应器处理含酚废水效果的影响。实验结果表明:经过42d驯化后,可以在高浓度含酚废水中正常运行,MBR系统对COD和氨氮的去除率分别可达98%和80.6%。当苯酚浓度为134mg/L时,处理的最佳水力停留时间为3h,最佳污泥浓度(MLSS)为7367mg/L。  相似文献   

12.
High strength refractory organic stream is produced during the production of 2-phenylamino-3-methyl-6-di-n-butylaminofluoran (One Dye Black 2,abbr.ODB 2),a novel heat-sensitive material with a promising market.In this study,a combination of acidification- precipitation,primary biological treatment,Fenton's oxidation and another biological treatment was successfully used for the removal of COD from 18000-25000 mg/L to below 200 mg/L from the ODB 2 production wastewater in a pilot experiment.A COD removal of 70%-80% was achieved by acidification-precipitation under a pH of 2.5-3.0.The first step biodegradation permitted an average COD removal of 70% under an hydraulic residence time (HRT) of 30 h.By batch tests,the optimum conditions of Fenton's oxidation were acquired as:Fe~(2 ) dose 6.0 mmol/L;H_2O_2 dose 3000 mg/L;and reaction time 6 h.The second step biological treatment could ensure an effluent COD below 200 mg/L under an HRT of 10 h following the Fenton's treatment.  相似文献   

13.
High strength refractory organic stream is produced during the production of 2-phenylamino-3-methyl-6-di-n-butylaminofluoran (One Dye Black 2, abbr. ODB 2), a novel heat-sensitive material with a promising market. In this study, a combination of acidificationprecipitation, primary biological treatment, Fenton's oxidation and another biological treatment was successfully used for the removal of COD from 18000-25000 mg/L to below 200 mg/L from the ODB 2 production wastewater in a pilot experiment. A COD removal of 70%-80% was achieved by acidification-precipitation under a pH of 2.5-3.0. The first step biodegradafion permitted an average COD removal of 70% under an hydraulic residence time (HRT) of 30 h. By batch tests, the optimum conditions of Fenton's oxidation were acquired as: Fe^2+ dose 6.0 mmol/L; H2O2 dose 3000 mg/L; and reaction time 6 h. The second step biological treatment could ensure an effluent COD below 200 mg/L under an HRT of 10 h following the Fenton's treatment.  相似文献   

14.
The pilot-scale experimental apparatus and the procedure of the chemical and biological flocculation process to verify the feasibility in treating Shanghai municipal sewage were introduced in this paper. In addition, the biological function of the process was discussed. The results of optimal running showed that in the reaction tank, the concentration of mixed liquor suspended solid(MLSS) was 2 g/L, hydraulic retention time(HRT) was 35 min, dosage of liquid polyaluminium chloride(PAC) was 60 mg/L, and the concentration of polyacrylamide(PAM) was 0.5 mg/L. The effluent average concentrations of CODcr, TP, SS and BOD5 were 50 mg/L, 0.62 mg/L, 18 mg/L, and 17 mg/L, respectively. These were better than the designed demand. In addition, the existence of biological degradation in this system was proven by several methods. The removal efficiencies of the chemical and biological flocculation process were 20% higher than that of the chemical flocculation process above at the same coagulant dosage. The treatment process under different situations was evaluated on a pilot-scale experiment, and the results provided magnificent parameters and optimal condition for future operation of the plant.  相似文献   

15.
泳动床/好氧颗粒污泥新技术处理生活污水的特性研究   总被引:8,自引:0,他引:8  
张岩  王永胜  白玉华  陈晨  吕鑑  张杰 《环境科学》2007,28(10):2249-2254
基于生物膜法和活性污泥法的联合工艺技术,开发了泳动床/好氧颗粒污泥污水处理新技术.试验阶段,泳动床/好氧颗粒污泥技术表现出高效处理生活污水和实现污泥减量的显著特性.在水力停留时间HRT为3.2 h, COD负荷与NH+4-N负荷分别为2.03  kg/(m·d) 和0.52  kg/(m·d)时,分别获得COD 90.9%和NH+4-N 98.3%的平均去除效果.系统运行16 d开始出现好氧颗粒污泥,颗粒呈球形、椭球形和棒形,试验阶段混合液悬浮固体浓度MLSS最高达5 640 mg/L, MLVSS/MLSS平均高达0.87.此外,镜检表明好氧颗粒污泥与生物膜均聚集大量的原生动物和后生动物,形成较长和较稳定的食物链,有利于污泥减量,运行过程中污泥产率(MLSS/CODremoved)为0.175 5,仅为普通好氧工艺的50%左右.  相似文献   

16.
MBR工艺处理高盐度废水试验   总被引:3,自引:0,他引:3  
采用MBR工艺对高盐度废水处理的影响因素进行研究。试验条件如下:污水中海水比例为50%,COD为700~800 mg/L,氨氮为80~100 mg/L,HRT为12 h,污泥浓度为7~8 g/L。试验结果表明:在高盐度条件下,采用低溶解氧(DO为1~2 mg/L),COD和氨氮的平均去除率可分别达到91.91%和91.44%;但氨氮负荷提高到0.4 kg/(m3.d)左右时,其平均去除率仅为62.47%。通过降低DO浓度和提高进水氨氮浓度可以使亚硝化率达到50%以上,但不能保持稳定的亚硝酸盐积累。  相似文献   

17.
采用了膜生物膜工艺处理含盐羧甲基纤维素生产废水。接种污泥为普通污泥,经驯化使其适应含盐废水,在污泥驯化阶段,生物膜表现出极佳的盐度冲击后恢复能力。通过较长的水力停留时间(5~15 d)和较低的COD有机负荷(平均1.6 kg/(m3·d)左右),生物膜COD去除率基本达90%。膜池内,悬浮固体浓度基本保持在5 000 mg/L以内;通过聚偏氟乙烯中空纤维膜过滤,出水悬浮固体浓度保持在5 mg/L以内。膜污染可通过重复的气水反洗和定期的化学清洗得以缓解。  相似文献   

18.
The lack and pollution of water resource make wastewater reuse necessary. The pilot scale long-term tests for submerged membrane bioreactor were conducted to treat the effluents of anaerobic or aerobic treatment process for the high-strength Chinese traditional medicine wastewater. This article was focused on the feasibility of the wastewater treatment and reuse at shorter hydraulic retention time (HRT) of 5.0, 3.2 and 2.13 h. MLSS growth, membrane flux, vacuum values and chemical cleaning periods were also investigated. The experimental results of treating two-phase anaerobic treatment effluent demonstrated that the CODfilt was less than 100 mg/L when the influent COD was between 500-10000 mg/L at HRT of 5.0 h, which could satisfy the normal discharged standard in China. The experimental results to treat cross flow aerobic reactor effluent demonstrated that the average value of CODfilt was 17.28 mg/L when the average value of influent COD was 192.84 mg/L at HRT of 2.13 h during 106 d, which could completely meet the normal standard for water reuse. The maximum MLSS and MLVSS reached 24000 and 14500 mg/L at HRT of 3.2 h respectively. Membrane flux had maximal resume degrees of 94.7% at vacuum value of 0.02 MPa after cleaning. Chemical cleaning periods of membrane module were 150 d. A simulation model of operational parameters was also established based on the theory of back propagation neural network and linear regression of traditional mathematical model. The simulation model showed that the optimum operational parameters were suggested as follows: HRT was 5.0 h, SRT was 100 d, the range of COD loading rate was between 10.664-20.451 kg/(m3.d), the range of MLSS was between 7543-13694 mg/L.  相似文献   

19.
利用厌氧折流板反应器,分别考察了反应器启动,及不同COD/SO42-比值和硫酸盐负荷对模拟废水中SO42-去除的影响。实验在(32±0.1)℃,pH为6.06.5的条件下连续运行。结果表明:ABR经过约90 d的启动驯化阶段后,进水硫酸盐及COD浓度分别为1 500 mg/L和3 000 mg/L,水力停留时间为12 h条件下,硫酸盐去除率达到了92%。固定COD/SO42-比值为2.5时,随着进水SO42-浓度的增加(1 5006.5的条件下连续运行。结果表明:ABR经过约90 d的启动驯化阶段后,进水硫酸盐及COD浓度分别为1 500 mg/L和3 000 mg/L,水力停留时间为12 h条件下,硫酸盐去除率达到了92%。固定COD/SO42-比值为2.5时,随着进水SO42-浓度的增加(1 5003 500 mg/L),SO42-去除率逐渐下降,最低为60%,相反SO42-去除速率随着硫酸盐浓度的增加而增加,最大为7.98 kg(/m3.d);维持恒定的硫酸盐浓度(1 500 mg/L),逐渐缩短水力停留时间以提高反应器中硫酸盐负荷,SO42-去除率呈现先上升后下降的复杂变化趋势,当水力停留时间为6 h时,SO42-去除率达到最大;随着COD/SO42-比值的提高,硫酸盐去除能力增强,且反应体系对硫酸盐负荷的耐受能力也逐渐增强。  相似文献   

20.
UBF-物理化学组合工艺处理Zn5-ASA医药废水的研究   总被引:1,自引:0,他引:1  
采用砂滤-UBF厌氧-絮凝沉淀工艺处理高浓度Zn5-ASA医药废水。实验结果表明,对于COD为8000-10000mg/L,色度7000-9000倍的Zn5-ASA废水,加石灰乳和H2SO4预调,经砂滤柱过滤后,COD会去除20%左右;再进以聚丙烯环为填料的厌氧UBF反应器,HRT为10.57h,COD去除率达83%-89%;出水再经化学絮凝沉淀后,无色透明,COD浓度远小于1000mg/L,符合GB8978-96三级排放标准要求,且色度小于10倍。  相似文献   