首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 140 毫秒
1.
采用SBR-ASBR组合工艺处理实际生活污水,SBR中考察缺氧/好氧时间比及温度对部分亚硝化(partial nitritation,PN)的作用,ASBR中研究COD/NO2--N(C/N)对厌氧氨氧化(anaerobic ammonium oxidation,ANAMMOX)协同反硝化脱氮除碳的影响.①控制温度为25℃,在缺氧/好氧时间比为30 min:30 min,单周期交替3次时,NO2--N积累率(NiAR)于第22 d为98.06%,比亚硝态氮产生速率(SNiPR,以N/VSS计)为0.28g·(g·d)-1,同步硝化反硝化去除的TN和COD分别为12.29 mg·L-1和110.36mg·L-1.②在缺氧/好氧时间比为30 min:30 min下,温度为15℃时,丝状菌大量繁殖,污泥活性和沉降性变差;温度为30℃时,NH4+-N转化为NO2--N比例为86.83%,造成出水NH4+-N浓度过低,不能为厌氧氨氧化提供合适基质浓度;温度为25℃时,出水NH4+-N和NO2--N浓度分别为31.58 mg·L-1和35.04mg·L-1,匹配厌氧氨氧化基质比.③组合工艺脱氮性能良好,出水TN、NH4+-N和COD浓度分别稳定在13.13、4.83和69.96mg·L-1,去除率分别为83.10%、93.64%和75.11%.调节ASBR进水C/N为2.5、2.0和1.5时,C/N为2.0时厌氧氨氧化协同反硝化脱氮除碳性能最佳,出水NH4+-N、NO2--N、NO3--N和COD分别为0.09、0.25、1.04和32.73mg·L-1.  相似文献   

2.
BACF处理高氨氮进水的硝化与反硝化作用   总被引:4,自引:1,他引:3  
采用生物活性炭滤池(BACF)深度处理高NH4+-N微污染水源水.结果表明,BACF对NH4+-N的去除率与进水NH4+-N浓度有关,当进水NH4+-N<1.0mg/L时,去除率达95%以上;当进水NH4+-N较高(1.5~4.9mg/L范围)、进水DO≤10mg/L时,去除率随进水浓度的增加而下降,最低降到30%左右.限制生物活性炭滤池硝化作用的主要因素是进水的DO,由于硝化菌与异养菌的共同竞争,在滤床0.4m深度内DO被消耗殆尽,出水DO基本为0(小于0.2mg/L),滤床被自然分成好氧区与缺氧区,在好氧区发生硝化与有机物的降解反应,在缺氧区则发生反硝化反应,由于碳源受限,反硝化反应进行得不彻底,造成滤池出水NO2--N升高.在缺氧区内除存在反硝化菌外,还存在好氧的硝化菌与异养菌.  相似文献   

3.
简捷硝化—反硝化过程处理焦化废水的研究   总被引:17,自引:0,他引:17       下载免费PDF全文
耿艳楼  钱易 《环境科学》1993,14(3):2-6,41
简捷硝化-反硝化过程处理焦化废水具有去除负荷高、出水浓度低、可节省反硝化碳源等优点.试验表明,当系统进水COD、NH_3-N和TN浓度分别为1204.8、274.3和443mg/L,系统总水力停留时间为26.2h时,系统出水COD、NH_3-N、NO_~-2-N、NO_3~--N和TN浓度分别为36.3、12.1、9.25、2.46和44.4mg/L.试验结果还证明本文所采用的系统确实处于简捷硝化-反硝化状态.  相似文献   

4.
为探究深水水库沉积物微生物功能特征及利用价值,于2019年在实验室对小湾水库表层沉积物微生物进行了驯化分离,并分析了其中一株细菌的脱氮效率.结果表明,分离出的细菌XW731经鉴定属于假单胞菌属(Pseudomonas sp.),是一种贫营养型好氧反硝化菌;在分别以NH4+-N、NO3--N和NO2--N为唯一氮源时,该菌对NH4+-N、NO3--N和NO2--N去除率分别为33.6%、68.5%和9.1%;以NH4+-N和NO3--N为氮源时,对NH4+-N和NO3--N去除率分别为66.4%、89.6%,同步硝化反硝化能力更强.将该菌投加到两种城市微污染水体后测试表明,该菌对城市河道水体的NH4+-N和NO3--N去除率分别为38.3%和42.4%,对城市降雨水体的NH4+-N和NO3--N去除率分别为22.2%和7.7%.  相似文献   

5.
原水添加比例对猪场废水厌氧消化液后处理的影响   总被引:12,自引:1,他引:12  
采用序批式反应器(SBR)处理猪场废水厌氧消化液,研究添加原水(配水)比例对处理性能的影响.连续动态试验表明,配水30%的处理,出水NH3-N浓度低,一般在10 mg/L以下;配水10%、20%处理的出水NH3-N浓度逐渐升高,至试验结束时,出水NH3-N分别达300 mg/L和80 mg/L左右.主要是因为配水30%的反应系统,pH能稳定在7.7左右,而配水10%、20%的反应系统,pH逐渐下降直至降到5.5以下.1个运行周期的监测表明,配水10%、20%、30%的处理,NO-2-N峰值、NH3-N低值分别出现在曝气第4 h、第3 h、第2 h.配水比例越大,NH3-N氧化速度越快,原因是配水比例越高,反硝化程度越高,系统pH也越高.批式反硝化试验表明,BOD5/TN越高,反硝化速率越快.动态和批式试验都说明,消化液好氧后处理系统正常运行的配水比必须达到30%以上.  相似文献   

6.
生物沸石床污水脱氮效果及机理   总被引:33,自引:4,他引:29  
研究了生物沸石床对模拟村镇生活污水中各形态氮及COD等污染物的去除效果结果表明,生物沸石床对NH3--N去除效果明显且稳定,去除率大于95%,对NO3--N的去除则受水力停留时间的影响较大从机理分析,生物沸石对NH3-N的去除主要依靠化学吸附、离子交换以及生物硝化的协同作用,而对NO3--N的去除主要依赖反硝化作用.生物沸石的硝化作用明显,并受溶解氧浓度限制,沸石床中部沸石硝化强度只有表层沸石的1/2;其反硝化能力则随实验条件中C/N的不同而变化明显,当COD/TN=5时,反硝化作用最强,在时间变化规律上,前6h反硝化速率最大.  相似文献   

7.
环流曝气塔中生物脱氮过程的研究   总被引:3,自引:0,他引:3  
利用环流曝气塔进行同时硝化/反硝化(sND)脱氮实验.实验中,分别采用不同降解性能的碳源以及采用不同的碳源投加方式,研究反应器内的脱氮过程,监测处理过程中NOx--N浓度和溶解氧DO的变化.实验显示,在COD 800mg/L+800mg/L的分批加料方式下,NH4+-N的降解得到加强,出水中NH4+-N浓度低于3mg/L;利用较难降解物质作为碳源时,利于反应器内低溶解氧条件的出现,促进了反硝化的进行,实验在采用醇类碳源时脱氮效果好于葡萄糖的情况.  相似文献   

8.
水解酸化-反硝化-硝化组合工艺处理土霉素废水的效果   总被引:7,自引:0,他引:7  
采用水解酸化 反硝化 硝化的组合工艺对土霉素废水进行实验室规模连续处理 ,水解酸化和反硝化均采用上向流污泥床 ,硝化采用2个使用不同填料的生物膜反应器 ,稳定运行 70d .当进水COD和NH4+-N浓度分别为2200~3000mg/L和400~460mg/L时 ,该系统在总水力停留时间为56h的条件下 ,稳定实现80%以上的COD和TN去除率 .生物处理出水经48mg/L聚合硫酸铁(以铁计)处理后COD降至293mg/L,实现了废水的达标排放.  相似文献   

9.
赵丹  于德爽  李津  汪晓晨 《环境科学学报》2013,33(11):3007-3016
从稳定运行的ASBR厌氧氨氧化反应器中分离筛选出一株在缺氧和好氧条件下均具有高效反硝化能力的菌株ZD8,该菌株为假单胞属(Pseudomonas sp.),大小2 μm×0.25 μm,无鞭毛和芽孢.实验结果表明,缺氧条件下,ZD8最适合的碳源为柠檬酸钠;当C/N为10时,具有最佳的反硝化效果.菌株ZD8在缺氧条件下不具有硝化能力.在好氧条件下菌株ZD8获得最佳反硝化效果的C/N为22,最适合pH范围是7.2~9.9.菌株ZD8在好氧条件下具有高效的异养硝化能力,NH4+-N平均去除速率为8.3 mg·L-1·h-1.当以KNO3为氮源时ZD8的反硝化速率为13.1 mg·L-1·h-1;而以NaNO2为氮源时,其反硝化速率为6.98 mg·L-1·h-1.在同时存在NH4+-N和NO3--N或NH4+-N和NO2--N的系统中,菌株ZD8均首先利用NH4+-N发生硝化作用,NH4+-N的存在对反硝化具有抑制作用,并且NH4+-N对NO2--N的反硝化抑制作用更强;在同时存在NO3--N和NO2--N的系统中,菌株ZD8优先利用NO3--N进行好氧反硝化脱氮.  相似文献   

10.
补充碳源提取液对人工湿地脱氮作用的影响   总被引:6,自引:1,他引:5  
为了提高人工湿地的脱氮效率,在不同条件下分别对美人蕉、香蒲及稻杆进行稀硫酸水解,以获得相应碳源提取液.正交实验表明,稀硫酸浓度的提高和水解时间的增加都会导致碳源释碳能力的提高,稻杆在5%稀硫酸溶液中水解30 min以上,释碳能力最高.通过观察,前2 d是系统脱氮反应高峰时段.对以NH4+-N和NO3--N为氮源的脱氮过程,随C/N比升高,NO3--N和TN去除率增长明显;而NH4+-N受溶解氧制约,去除有限;随C/N比升高,碳源对系统溶解氧的竞争会进一步抑制硝化反应的彻底进行.而对以NO3--N为氮源的反硝化过程,补充碳源对TN和NO3--N的去除有明显作用;TN去除率由54%提高到95%,NO3--N去除率由48%提高到96%;中间产物NO2--N的积累与NO3--N去除率有关;当NO3--N去除率较高时,NO2--N无积累.此外,基质反硝化强度也随C/N比升高呈上升趋势,湿地填料细沙层的反硝化强度略高于碎石层.  相似文献   

11.
For urban wastewater treatment, we conducted a novel four-stage step-feed wastewater treatment system combined with a fluidized bed laboratory experiment to investigate chemical oxygen demand (COD), NH4+-N, and total nitrogen (TN) removal performance. The removal rates of COD, NH4+-N and TN were 88.2%, 95.7%, and 86.4% with effluent concentrations of COD, NH4+-N and TN less than 50, 8, and 10 mg/L, respectively. Biomass and bacterial activities were also measured, with results showing more nitrobacteria in the activated sludge than in the biofilm; however, bacterial activity of the biofilm biomass and the activated sludge were similar. Nitrogen concentrations during the process were also detected, with simultaneous nitrification and denitrification found to be obvious.  相似文献   

12.
邵林广  陈斌  黄霞  钱易 《环境科学》1994,15(6):51-53
用内填YDT弹性立体填料的水解(酸化)-缺氧-好氧固定床生物膜系统焦化废水。结果:当进水COD和NH3-N浓度分别为1065mg/L和253mg/L,系统水力停留时间(HRT)为33.5h,混合液回流比为3.6时,出水COD约为180mg/L,NH3-N为5mg/L,COD和NH3-N的去除率分别达83%和98%。  相似文献   

13.
添加原水改善SBR工艺处理猪场废水厌氧消化液性能   总被引:26,自引:7,他引:19  
采用序批式反应器(SBR)工艺直接处理猪场废水厌氧消化液,处理系统的效率较低,COD去除率仅有10%左右,NH4+-N去除率70%左右;处理出水水质较差,出水COD高于1 000mg/L,出水NH4+-N在200mg/L左右;处理系统的工作不稳定,效能逐渐恶化.在猪场废水厌氧消化液中添加部分未经厌氧消化的猪场废水(原水),处理系统的处理效率明显提高,COD去除率高于80%,出水COD降到250~350mg/L;NH4+-N去除率高于99%,出水NH4+-N小于10mg/L;处理系统的稳定性也得到增强.添加原水后,猪场废水厌氧消化液的BOD5/COD比值从0.19上升到0.54,BOD5/TN比值从0.28上升到2.04,增加了微生物生长和反硝化所需的碳源,强化了反硝化作用,不仅提高了总氮去除效率,而且通过回补碱度,维持了处理系统的pH值稳定.  相似文献   

14.
针对某一城市污水处理厂"混合型城市污水"的特征,以厂区曝气沉砂池出水作为处理对象,设计一套A2/O工艺强化脱氮除磷中试装置。当进水COD、NH3-N、TN、TP的平均质量浓度分别为594,25.0,37.6,7.66 mg/L时,经A2/O工艺强化处理后,出水COD、NH3-N、TN、TP的平均质量浓度分别为46.7,5.5,12.73,0.7 mg/L,对COD、NH3-N、TN、TP的平均去除率分别达91.51%、79.73%、65.78%和88.65%,出水水质达GB 18918—2002《城镇污水处理厂污染物排放标准》一级标准,取得了良好的污染物去除和脱氮除磷效果,且当系统稳定运行时总体出水水质相对稳定。  相似文献   

15.
本研究构建了厌氧膜生物反应器(AnMBR)-部分亚硝化/厌氧氨氧化(PN/Anammox)污水处理工艺,以探究AnMBR-PN/A工艺处理效果最佳的水力停留时间(HRT).AnMBR将厌氧生物处理与膜分离技术相结合实现有机物去除,AnMBR出水NH4+-N通过PN部分转化为NO2--N,最终通过NO2--N氧化剩余NH4+-N去除.实验结果表明:在HRT=11.2 h时,AnMBR-PN/A工艺化学需氧量(COD)去除率稳定在97%以上,COD转化为CH4效率超过77.5%,总氮(TN)去除率为78%,出水COD和TN浓度分别低于14和11 mg·L-1.AnMBR段COD去除率达到95%,平均甲烷产率为0.39 L·L-1·d-1.PN段实现了NO2--N的高效积累,其出水中NO2-/NH4+为0.91±0.11.Anammox段出水中的NO2--N、NH4+-N和NO3--N浓度分别低于1.0、4.9和5.1 mg·L-1.高通量测序结果表明PN段氨氧化菌主要为Nitrosomonas,丰度为7.09%,Anammox段主要微生物为Candidatus Brocadia,丰度高达21.01%.本研究构建的AnMBR-PN/A工艺实现了污水处理过程的高效能源回收和深度自养脱氮,研究成果为工程应用提供了理论支撑.  相似文献   

16.
城市高污染水体生物生态处理技术研究   总被引:2,自引:0,他引:2  
针对城市高污染水体的特点,建成了粉煤灰基质滤料生物过滤与复合水生植物滤床组合处理系统。生物过滤在有机物和氨氮的去除方面起主要作用,磷则主要是通过人工湿地去除。运行结果表明,组合工艺出水COD、TP、NH3-N、TN平均浓度分别为16.35 mg/L、0.08 mg/L、2.68 mg/L、15.63 mg/L,均满足《城市污水再生利用——城市杂用水水质》(GB/T18920-2002)标准要求。  相似文献   

17.
基因工程菌生物强化MBR工艺处理阿特拉津试验研究   总被引:11,自引:6,他引:5  
刘春  黄霞  孙炜  王慧 《环境科学》2007,28(2):417-421
以生活污水为共基质,考察了基因工程菌在MBR和活性污泥反应器中对阿特拉津的生物强化处理效果,以及生物强化处理对污泥性状的影响.结果表明,基因工程菌在MBR中对阿特拉津具有很好的生物强化处理效果,阿特拉津平均出水浓度为0.84 mg/L,平均去除率为95%,最大去除负荷可以达到70 mg/(L·d).生物强化的MBR对生活污水中COD的平均去除率为71%,COD平均出水浓度65 mg/L,COD容积负荷增加对COD去除效果有一定影响;对生活污水中的氨氮具有很好的去除效果,氨氮平均出水浓度为1.1 mg/L,平均去除率为97%,最大氨氮去除负荷为143 mg/(L·d).与普通MBR污泥相比,生物强化MBR污泥的硝化活性和亚硝化活性略高,碳氧化活性略低,因此表现出氨氮处理效果很好,COD处理效果略差.阿特拉津的存在会对污泥性状产生影响,可能是造成污泥碳氧化活性低的原因.  相似文献   

18.
研究一体化连续流间歇曝气膜生物反应器(IMBR)处理低C/N城市污水的工艺效能。试验结果表明:反应器在曝气2 h、搅拌2 h的运行模式下,对COD、NH4+-N、TN和SS的平均去除率分别达到了87%,83.4%,75.4%和97.81%,各出水质量浓度平均值分别为17.5,4.59,7.63和2 mg/L,出水水质达到了GB/T18920-2002《城市污水再生利用城市杂用水水质》标准。  相似文献   

19.
探究NH4+-N冲击对微压反应器(MPR)污染物去除效率的影响,通过提高单周期瞬时进水NH4+-N浓度至40,50 mg/L,对MPR进行冲击。结果表明:常规负荷下,MPR具有良好的污染物去除效果。冲击周期降解历时数据显示,在进水40 mg/L NH4+-N冲击周期内进水ρ(COD)、ρ(NH4+-N)、ρ(TP)分别为192.58,40.96,2.52 mg/L,出水分别为38.16,0.70,0.26 mg/L,去除效果无显著变化,出水TN浓度上升至16.04 mg/L。增加NH4+-N冲击浓度至50 mg/L,冲击周期内NH4+-N降解速率不变,反硝化速率提高,出水ρ(NH4+-N)、ρ(TN)升高至4.95,17.62 mg/L,TN降解主要受碳源不足影响;TP去除效果无变化,冲击后57个周期内除磷系统受到影响,出水TP出现较大波动,最高浓度达到2.6 mg/L。以上结果表明,MPR系统受到NH4+-N冲击后1个周期内,脱氮性能即可恢复,说明冲击对脱氮系统造成了可逆的短期影响,但对除磷系统造成不可逆的长期影响。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号