1.
分体式膜-生物反应器在废水处理中的工艺条件   总被引:14,自引:3,他引:11  
对分体式膜-生物反应器(RMBR)处理废水进行了研究.进水CODCr:312~584mg/L,RMBR的出水CODCr在运行4d后<15 mg/L并稳定.向生物反应器添加0.5g/L(混合液)的粉末活性炭(PAC)后出水CODCr<4.22mg/L.膜侧污水流速在0.9~1.9m/s范围内,临界膜通量随膜侧污水流速的增大而增大.添加PAC,组合添加PAC和Al2(SO4)3·18 H2O均可有效提高临界膜通量.在膜侧流速1.9m/s的条件下,临界膜通量从72L/(m2·h)分别增至76L/(m2·h)和81 L/(m2·h)在22℃~30℃范围内,每升高1℃可提高膜通量1.9%.在连续运行100d中,RMBR可在无任何物理,化学清洗的条件下运行14d而透膜压力无增大,膜通量不降低.对于已污染的膜,水清洗、水碱共间清洗、水碱酸共同清洗可分别恢复至新膜膜通量的47%、83%、94%.  相似文献   

2.
采用具有自由端的梳状中空纤维膜-生物反应器处理污水,考察了其膜污染控制性能.结果发现,如果将膜污染定义为恒压操作下的膜通量下降,膜组件b比膜组件a易获得更大的膜通量,具有更优异的抗污染效果.含膜组件b的MBR在温度为22~26℃,污泥浓度为7 500~10 500  mg/L,曝气量为200 L/h,抽停时间比为9 min/1 min,压力为0.02 MPa的条件下连续运行47 d,膜通量维持在4.0~8.0  L·(m2·h)-1,其间不需要任何水力或化学清洗.由于这种膜组件易充分发挥曝气的作用,不易污染,因而所需曝气量较小,并且当抽停时间比从12 min/1 min变化到6 min/1 min,膜通量差别不大.对膜的清洗试验表明,水力清洗+化学清洗+乙醇浸泡是最有效的清洗方法.水力清洗+化学清洗后,较之水力清洗,中空纤维膜表面上的胶团数目和面积大大减少,膜孔变得更加清晰.  相似文献   

3.
动态膜-生物反应器对城市污水的处理   总被引:43,自引:9,他引:34  
范彬  黄霞  文湘华  于妍 《环境科学》2002,23(6):51-56
应用动态膜原理,以0.1mm孔径的普通筛网代替固定膜材料构成一体式动态膜-生物反应器(DMBR)处理实际城市污水.HRT=3.5h时,出水水质良好.DMBR在小于数cm的液位差下自流出水,出水中的SS最高检测值为4.05mg/L,但在多数情况下为0.在MLSS约7000~8000mg/L下,当动态膜通量为14.9L/(m2·h)时,出水水头仅为5.8mm;27d连续运行,出水水头没有明显改变.动态膜对反应器上清液中的COD和TOC的平均去除率分别为28.74%和36.9%.当溶解氧浓度大于2~3mg/L时,氨氮去除率大于96%.  相似文献   

4.
好氧颗粒污泥膜生物反应器的运行特性   总被引:6,自引:0,他引:6  
以人工合成模拟废水对好氧颗粒污泥膜生物反应器(MBR)的运行特性和膜污染进行了研究.结果表明:在HRT为6h,溶氧浓度为4~6mg.L-1,COD的容积负荷为7.24kg·(m3·d)-1的条件下,COD的去除率可达96%以上.当NH3-N的容积负荷为0.17kg·(m3·d)-1时,NH3-N的去除率可达60%.COD/N比的变化,对好氧颗粒污泥MBR的COD及NH3-N去除率基本没有影响.稳定运行过程时,MBR中好氧颗粒污泥浓度(MLSS)基本维持在14~16mg·L-1.较高的污泥浓度和颗粒污泥内部缺氧和厌氧环境的存在,使MBR中硝化和反硝化过程能同时存在.同时,比较了2种不同形态的活性污泥(颗粒污泥和絮状污泥)在MBR运行过程中膜通量的变化趋势,结果表明,颗粒污泥MBR膜通量的下降速度明显比絮状污泥MBR的下降速度慢很多,且通过空气反冲或用水清洗即可使通量基本恢复.  相似文献   

5.
PES/PAN膜在MBR中膜污染机理及抗污染性能   总被引:2,自引:2,他引:0  
采用液-固相转化法,以聚醚砜(PES)、氯化锂(LiCl)、聚乙烯吡咯烷酮(PVP)和N,N-二甲基乙酰胺(DMAc)为原料制备PES膜,并在体系中添加聚丙烯腈(PAN)制备PES/PAN膜。在操作温度25℃,操作压力90KPa条件下制得的PES/PAN膜、自制PES膜和商品PES超滤膜分别为222L/(m·2h)左右,130L/(m·2h)左右,82L/(m·2h)左右。通过膜生物反应器中膜阻力的测定,表明膜污染主要由沉积层引起的,另一方面长期运行膜孔堵塞也是阻力增大的原因。在MBR中运行时,PES/PAN膜、自制PES膜和商品PES超滤膜膜通量的衰减速率分别为0.2559L/(m·2h·min)、0.3366L/(m·2h·min)、0.3539L/(m·2h·min),PES/PAN膜通量衰减最慢;在MBR中运行15d后,经过化学清洗,PES/PAN膜、自制PES膜和商品PES超滤膜纯水通量恢复率分别为83.75%、63.58%、61.32%,PES/PAN膜通量恢复率最大,抗污染性优于PES膜。  相似文献   

6.
机械清洗膜组件对膜通量影响的初步研究   总被引:2,自引:0,他引:2  
试验设计了强化机械清洗膜组件M1和机械清洗膜组件M2,通过正交试验考察了污泥浓度、曝气量、运行膜通量和抽吸时间:间歇时间对2组膜组件的膜过滤特性的影响.结果表明,M1膜组件可以弱化不利条件如高污泥浓度(MLSS)、高运行膜通量和低曝气强度的影响;曝气量和运行膜通量是影响膜比通量的主要因素;并得到一组较佳的操作条件组合:污泥浓度6g/L、曝气量0.5m3/h、抽吸时间和间歇时间的比为12:1.在此条件下长期运行试验表明,M1和M2膜通量均可以维持在40L/(h·m2).通过测定2组膜组件的阻力分布,表明机械清洗可以大大减弱膜面泥饼层污染.  相似文献   

7.
气升循环分体式膜生物反应器再生回用厕所污水的研究   总被引:20,自引:0,他引:20  
徐慧芳  樊耀波 《环境科学》2003,24(2):125-129
研究了分体浸没式膜生物反应器及其应用于厕所污水的再生回用.试验结果表明,在人水浓度COD440~970mg/L、BOD5 307~612mg/L、NH3-N59~111mg/L的情况下,出水水质稳定,平均COD<47mg/L、BOD5<8.5mg/L、NH3-N<20mg/L,处理水质达到建设部颁布的生活杂用水回用标准.研究了动力学参数污泥负荷、容积负荷和HRT对出水COD的影响,确定本试验较佳的污泥负荷和容积负荷分别为0.1kg/(kg·d)和1kg/(m3·d),HRT为7~8h.本文对污泥浓度、温度和产水时间与间歇时间比对膜通量的影响进行了测定与探讨.  相似文献   

8.
纳米Fe_3O_4强化混凝-Fenton氧化预处理垃圾渗滤液   总被引:1,自引:1,他引:0       下载免费PDF全文
采用纳米Fe_3O_4与Fe Cl3制备复合混凝剂,利用混凝沉淀-Fenton氧化工艺预处理垃圾渗滤液原水,研究其处理效果。结果表明:在纳米Fe_3O_4投加量为2 g/L,Fe Cl3投加量为1.4 g/L时制备的复合混凝剂,在p H值为6.5,转速为300 r/min下快速搅拌1 min,转速为100 r/min下慢速搅拌30 min,沉淀时间为30 min的条件下,COD去除率为56.8%,ρ(COD)可由5 240 mg/L降低到2 264 mg/L;利用Fenton氧化处理混凝处理出水,在H_2O_2的投加量为5.5 g/L,n(H_2O_2)∶n(Fe2+)=4,p H值为6,反应时间为80 min,反应温度为25℃的最佳条件下,COD和氨氮的去除率分别为55.7%和40.1%,最终出水ρ(COD)和ρ(氨氮)分别为1 003 mg/L和670 mg/L;该组合工艺对垃圾渗滤液有较好的处理效果,COD、色度和氨氮的去除率分别为80.8%、59.5%和76.2%。  相似文献   

9.
新型管式动态膜生物反应器及处理垃圾渗滤液的研究   总被引:7,自引:0,他引:7  
研究了1种新型玻璃纤维管式动态膜生物反应器(DMBR)并考察其对垃圾渗滤液的处理效果.研究表明,动态膜生物反应器运行稳定,DMBR在重力自流出水下运行近80 d,在过滤压差为2?900 Pa的情况下,膜通量维持在3.75 L/(m2·h)左右,在膜组件的结构参数改进之后,膜通量有较大提高,在过滤压差为1 450 Pa下能较长时间稳定在6 L/(m2·h).本研究还考察了动态膜的过滤性能和系统处理效果,系统出水浊度在1.0 NTU以下,对COD、BOD5和NH+4-N的平均去除效率分别超过71%、96%和98%,动态膜对混合液上清液COD有19.34%的截留作用.  相似文献   

10.
文章采用生物碳纤维膜材料,考察了不同水力停留时间(HRT)、气水比对生物碳纤维膜处理生活污水效果的影响,优化和确定了该工艺的最佳运行参数,同时观察了最佳运行参数下生物碳纤维膜材料的膜污染问题。研究结果表明,在HRT=10 h,气水比=25∶1,污泥浓度为8 g/L时,该工艺达到最优的运行条件,此时反应器出水的化学需氧量(COD)、氨氮(NH4+-N)及浊度分别为15、1.0 mg/L、0.15NTU,处理效果良好,达到《城镇污水处理厂污染物排放标准》(GB 18918-2002)一级A排放标准,同时生物碳纤维膜反应器的膜清洗周期较长,膜污染情况较轻缓。证实了生物碳纤维膜工艺处理生活污水的可行性和优越性。  相似文献   

11.
Membrane fouling limits the effects of long-term stable operation of membrane bioreactor (MBR). Control of membrane fouling can extend the membrane life and reduce water treatment cost effectively. A pilot scale anoxic/aerobic-membrane bioreactor (A/O-MBR, 40 L/hr) was used to treat the hyperhaline municipal sewage from a processing zone of Tianjin, China. Impact factors including mixed liquid sludge suspension (MLSS), sludge viscosity (μup), microorganisms, extracellular polymeric substances (EPS), aeration intensity and suction/suspended time on membrane fouling and pollution control were studied. The relationships among various factors associated with membrane fouling were analyzed. Results showed that there was a positive correlation among MLSS, sludge viscosity and trans-membrane pressure (TMP). Considering water treatment efficiency and stable operation of the membrane module, MLSS of 5 g/L was suggested for the process. There was a same trend among EPS, sludge viscosity and TMP. Numbers and species of microorganisms affected membrane fouling. Either too high or too low aeration intensity was not conducive to membrane fouling control. Aeration intensity of 1.0 m3/hr (gas/water ratio of 25:1) is suggested for the process. A long suction time caused a rapid increase in membrane resistance. However, long suspended time cannot prevent the increase of membrane resistance effectively even though a suspended time was necessary for scale off particles from the membrane surface. The suction/suspended time of 12 min/3 min was selected for the process. The interaction of various environmental factors and operation conditions must be considered synthetically.  相似文献   

12.
膜-生物反应器运行条件对膜过滤特性的影响   总被引:58,自引:3,他引:55  
桂萍  黄霞  陈颍  文湘华  钱易 《环境科学》1999,20(3):38-41
试验采用膜抽吸压力的上升速率表征运行过程中膜过滤性能的变化。正交试验结果表明,缩短抽吸时间或延长暂停时间和增加曝气量均有利于减缓膜污染,但过短的抽吸时间、过长的暂停时间和过大曝气量不能进一步地减轻膜污染,因此应在保证一定产水量的前提下确定适宜的抽、停时间和曝气量。在污泥龄40d,污泥浓度稳定在5g/L左右的条件下,最佳组合操作条件为抽吸10min,停抽5min,曝气量4m^3/h。3个因素中抽吸时  相似文献   

13.
An anaerobic/oxic membrane bioreactor (A/O MBR) was used for treatment of dyeing wastewater from a woolen mill.COD and color of the wastewater were 54-473 mg/L and 40-400 dilution time (DT) respectively. The ratio of BOD5/COD was less than 0.13. By the A/O MBR process, the average removal of COD, BOD5, color and turbidity was 82%, 96%, 71% and 99%, respectively. The average COD, BOD5, color and turbidity of effluent was 37 nag/L, 0.8 mg/L, 40 DT and 0.44 NUT respectively. The effluent COD met the local standard of reuse water in Beijing, China. The average COD volume load of the anaerobic biological tank was 0. 0483 kgCOD/(m3·d) and that of the aeration tank of the MBR was 0. 3589 kgCOD/(m3·d). The sludge load of the MBR was 0.19 kgCOD/(kg· MLSS· d) on average and the maximum of that was 0.4 kgCOD/( kg· MLSS· d).The flux of the A/O membrane bioreactor could be remained at larger than 50 L/(h· m2· 0.1MPa). The results indicated that A/O membrane bioreactor has technical feasibility for treatment of woolen mill wastewater.  相似文献   

14.
一体式膜生物反应器污水资源化技术研究   总被引:3,自引:1,他引:3  
膜生物反应器是高效的污水处理工艺,但其高气水比运行条件产生的动力消耗与国外膜组件昂贵的价格成为膜生物反应器在我国应用的主要限制因素。为此本研究采用分体曝气形式,选择国产高抗污性能PVDF中空纤维膜,设计了间歇式膜生物反应器,研究了污泥浓度、曝气量和水力停留时间对一体式膜生物反应器去除污染物效果的影响。在低气水比条件下,MBR处理生活污水的研究表明,出水COD<50mg/L,BOD<10mg/L,NH3—N<20mg/L,浊度<3NTU,悬浮固体浓度为零,优于生活杂用水水质标准(CJ25.1-89)。  相似文献   

15.
采用平板陶瓷膜中试装置处理石化废水,分析了处理效果与膜污染情况,获得了平板陶瓷膜稳定运行条件下的工艺参数。结果表明:在COD为50~100 mg/L、浊度为2~11 NTU的进水条件下,平板陶瓷膜出水COD与浊度分别为20~42 mg/L和0.05~0.2 NTU,与双层过滤器+中空纤维超滤工艺出水水质较为接近;在运行通量40 L/(m 2·h)、反洗周期45 min、反洗时间60 s的条件下,采用浓度为100~150 mg/L的次氯酸钠每7小时进行1次化学清洗,平板陶瓷膜系统运行较为稳定。  相似文献   

16.
IntroductionThedyeingwastewaterofwoolenmillcontainsalotkindsofpollutants,suchasacidicdyes,dispersedyes,mordantdyes,auxiliaries,saltsandsoon .Theeffluentsfromwastewatertreatmentplantsfortreatmentofthedyeingwastewaterofwoolenmillswithnormalbiologicalproce…  相似文献   

17.
以除油后的实际餐厨废水为原料,在高温(50±1)℃条件下利用浸没式纤维膜生物反应器(AnMBR)进行连续厌氧消化试验,以水力停留时间(HRT)20d启动,HRT 15d运行,直到发生膜污染,试验共进行了50d.研究了反应器启动和运行期间的发酵特性和膜过滤性能.研究表明,反应器30d完成了启动,在HRT 15d条件下,甲烷产量达到578L/kgVSin,COD和挥发性固体(VS)去除率均达到94%以上,膜出水总挥发性脂肪酸(TVFA)浓度为(103±77) mg/L,其中乙酸浓度为(98±28) mg/L.系统pH 8.26,具有良好的稳定性.膜通量设定为9L/(m2·h),运行30d后发生了明显的膜污染,伴随着反应器内挥发性悬浮固体(VSS)浓度由8.1g/L逐渐增加到18/L.在处理高浓度餐厨废水时,AnMBR可以短时间启动且在8.5kgCOD/(m3·d)的高负荷条件下稳定运行,反应器中污泥浓度和溶解性微生物产物的增加导致膜过滤性能下降是导致膜污染的主要因素.  相似文献   