首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 58 毫秒
1.
• N-Cl-DCAM, an emerging N-DBP in drinking water was investigated. • A new BAC has a better removal efficiency for N-Cl-DCAM precursors than an old BAC. • N-Cl-DCAM precursors are more of low molecular weight and non-polar. • Adsorption of GAC plays a major role in removal of N-Cl-DCAM precursors by an O3-BAC. N-chloro-2,2-dichloroacetamide (N-Cl-DCAM) is an emerging nitrogenous disinfection by-product (N-DBP) which can occur in drinking water. In this study, an analytical method based on liquid chromatography with tandem mass spectrometry (LC-MS/MS) was developed to validate the concentration of N-Cl-DCAM, which was found to be 1.5 mg/L in the effluent of a waterworks receiving raw water from Taihu Lake, China. The changes of N-Cl-DCAM formation potential (N-Cl-DCAMFP) in the drinking water treatment process and the removal efficiency of its precursors in each unit were evaluated. Non-polar organics accounted for the majority of N-Cl-DCAM precursors, accounting for 70% of the N-Cl-DCAM FP. The effect of conventional water treatment processes on the removal of N-Cl-DCAM precursors was found to be unsatisfactory due to their poor performance in the removal of low molecular weight (MW) or non-polar organics. In the ozonation integrated with biological activated carbon (O3-BAC) process, the ozonation had little influence on the decrease of N-Cl-DCAM FP. The removal efficiency of precursors by a new BAC filter, in which the granular activated carbon (GAC) had only been used for four months was higher than that achieved by an old BAC filter in which the GAC had been used for two years. The different removal efficiencies of precursors were mainly due to the different adsorption capacities of GAC for individual precursors. Low MW or non-polar organics were predominantly removed by GAC, rather than biodegradation by microorganisms attached to GAC particles.  相似文献   

2.
● Abundance of MAGs carrying ARG-VF pairs unchanged in rivers after WWTP upgrade. ● Upgrade of WWTPs significantly reduced diversity of pathogenic genera in rivers. ● Upgrade of WWTPs reduced most VF (ARG) types carried by potential pathogens in rivers. ● Upgrade of WWTPs narrowed the pathogenic host ranges of ARGs and VFs in rivers. Wastewater treatment plants (WWTPs) with additional tertiary ultrafiltration membranes and ozonation treatment can improve water quality in receiving rivers. However, the impacts of WWTP upgrade (WWTP-UP) on pathogens carrying antibiotic resistance genes (ARGs) and virulence factors (VFs) in rivers remain poorly understood. In this study, ARGs, VFs, and their pathogenic hosts were investigated in three rivers impacted by large-scale WWTP-UP. A five-year sampling campaign covered the periods before and after WWTP-UP. Results showed that the abundance of total metagenome-assembled genomes (MAGs) containing both ARGs and VFs in receiving rivers did not decrease substantially after WWTP-UP, but the abundance of MAGs belonging to pathogenic genera that contain both ARGs and VFs (abbreviated as PAVs) declined markedly. Genome-resolved metagenomics further revealed that WWTP-UP not only reduced most types of VFs and ARGs in PAVs, but also effectively eliminated efflux pump and nutritional VFs carried by PAVs in receiving rivers. WWTP-UP narrowed the pathogenic host ranges of ARGs and VFs and mitigated the co-occurrence of ARGs and VFs in receiving rivers. These findings underline the importance of WWTP-UP for the alleviation of pathogens containing both ARGs and VFs in receiving rivers.  相似文献   

3.
• Published data was used to analyze the fate of ARGs in water treatment. • Biomass removal leads to the reduction in absolute abundance of ARGs. • Mechanism that filter biofilm maintain ARB/ARGs was summarized. • Potential BAR risks caused by biofiltration and chlorination were proposed. The bacterial antibiotic resistome (BAR) is one of the most serious contemporary medical challenges. The BAR problem in drinking water is receiving growing attention. In this study, we focused on the distribution, changes, and health risks of the BAR throughout the drinking water treatment system. We extracted the antibiotic resistance gene (ARG) data from recent publications and analyzed ARG profiles based on diversity, absolute abundance, and relative abundance. The absolute abundance of ARG was found to decrease with water treatment processes and was positively correlated with the abundance of 16S rRNA (r2 = 0.963, p<0.001), indicating that the reduction of ARG concentration was accompanied by decreasing biomass. Among treatment processes, biofiltration and chlorination were discovered to play important roles in shaping the bacterial antibiotic resistome. Chlorination exhibited positive effects in controlling the diversity of ARG, while biofiltration, especially granular activated carbon filtration, increased the diversity of ARG. Both biofiltration and chlorination altered the structure of the resistome by affecting relative ARG abundance. In addition, we analyzed the mechanism behind the impact of biofiltration and chlorination on the bacterial antibiotic resistome. By intercepting influent ARG-carrying bacteria, biofilters can enrich various ARGs and maintain ARGs in biofilm. Chlorination further selects bacteria co-resistant to chlorine and antibiotics. Finally, we proposed the BAR health risks caused by biofiltration and chlorination in water treatment. To reduce potential BAR risk in drinking water, membrane filtration technology and water boiling are recommended at the point of use.  相似文献   

4.
• Real ML-GFW with high salinity and high organics was degraded by O3/H2O2 process. • Successful optimization of operation conditions was attained using RSM based on CCD. • Single-factor experiments in advance ensured optimal experimental conditions. • The satisfactory removal efficiency of TOC was achieved in spite of high salinity. • The initial pH plays the most significant role in the degradation of ML-GFW. The present study reports the use of the O3/H2O2 process in the pretreatment of the mother liquor of gas field wastewater (ML-GFW), obtained from the multi-effect distillation treatment of the gas field wastewater. The range of optimal operation conditions was obtained by single-factor experiments. Response surface methodology (RSM) based on the central composite design (CCD) was used for the optimization procedure. A regression model with Total organic carbon (TOC) removal efficiency as the response value was established (R2 = 0.9865). The three key factors were arranged according to their significance as: pH>H2O2 dosage>ozone flow rate. The model predicted that the best operation conditions could be obtained at a pH of 10.9, an ozone flow rate of 0.8 L/min, and H2O2 dosage of 6.2 mL. The dosing ratio of ozone was calculated to be 9.84 mg O3/mg TOC. The maximum removal efficiency predicted was 75.9%, while the measured value was 72.3%. The relative deviation was found to be in an acceptable range. The ozone utilization and free radical quenching experiments showed that the addition of H2O2 promoted the decomposition of ozone to produce hydroxyl radicals (·OH). This also improved the ozone utilization efficiency. Gas chromatography-mass spectrometry (GC-MS) analysis showed that most of the organic matters in ML-GFW were degraded, while some residuals needed further treatment. This study provided the data and the necessary technical supports for further research on the treatment of ML-GFW.  相似文献   

5.
Extracellular DNA structure damaged by chlorination was characterized. Integrity of extracellular ARG genetic information after chlorination was determined. Typical chlorine doses will likely effectively diminish extracellular DNA and ARGs. Plasmid DNA/ARGs were less readily broken down than genomic DNA. The Bioanalyzer methodology effectively documented damage incurred to DNA. There is a need to improve understanding of the effect of chlorine disinfection on antibiotic resistance genes (ARGs) in order to advance relevant drinking water, wastewater, and reuse treatments. However, few studies have explicitly assessed the physical effects on the DNA. Here we examined the effects of free chlorine (1–20 mg Cl2/L) on extracellular genomic, plasmid DNA and select ARGs. Chlorination was found to decrease the fluorometric signal of extracellular genomic and plasmid DNA (ranging from 0.005 to 0.05 mg/mL) by 70%, relative to a no-chlorine control. Resulting DNA was further subject to a fragment analysis using a Bioanalyzer, indicating that chlorination resulted in fragmentation. Moreover, chlorine also effectively deactivated both chromosomal- and plasmid-borne ARGs, mecA and tetA, respectively. For concentrations >2 mg Cl2//L × 30 min, chlorine efficiently reduced the qPCR signal when the initial concentration of ARGs was 105 copies/mL or less. Notably, genomic DNA and mecA gene signals were more readily reduced by chlorine than the plasmid-borne tetA gene (by ~2 fold). Based on the results of qPCR with short (~200 bps) and long amplicons (~1200 bps), chlorination could destroy the integrity of ARGs, which likely reduces the possibility of natural transformation. Overall, our findings strongly illustrate that chlorination could be an effective method for inactivating extracellular chromosomal- and plasmid-borne DNA and ARGs.  相似文献   

6.
• Annual AOCs in MBR effluents were stable with small increase in warmer seasons. • Significant increase in AOC levels of tertiary effluents were observed. • Coagulation in prior to ozonation can reduce AOC formation in tertiary treatment. • ∆UV254 and SUVA can be surrogates to predict the AOC changes during ozonation. As water reuse development has increased, biological stability issues associated with reclaimed water have gained attention. This study evaluated assimilable organic carbon (AOC) in effluents from a full-scale membrane biological reactor (MBR) plant and found that they were generally stable over one year (125–216 µg/L), with slight increases in warmer seasons. After additional tertiary treatments, the largest increases in absolute and specific AOCs were detected during ozonation, followed by coagulation-ozonation and coagulation. Moreover, UV254 absorbance is known to be an effective surrogate to predict the AOC changes during ozonation. Applying coagulation prior to ozonation of MBR effluents for removal of large molecules was found to reduce the AOC formation compared with ozonation treatment alone. Finally, the results revealed that attention should be paid to seasonal variations in influent and organic fraction changes during treatment to enable sustainable water reuse.  相似文献   

7.
Sludge digestion is critical to control the spread of ARGs from wastewater to soil. Fate of ARGs in three pretreatment-AD processes was investigated. UP was more efficient for ARGs removal than AP and THP in pretreatment-AD process. The total ARGs concentration showed significant correlation with 16S rRNA gene. The bacteria carrying ARGs could be mainly affiliated with Proteobacteria. Sewage sludge in the wastewater treatment plants contains considerable amount of antibiotic resistance genes (ARGs). A few studies have reported that anaerobic digestion (AD) could successfully remove some ARGs from sewage sludge, but information on the fate of ARGs in sludge pretreatment-AD process is still very limited. In this study, three sludge pretreatment methods, including alkaline, thermal hydrolysis and ultrasonic pretreatments, were compared to investigate the distribution and removal of ARGs in the sludge pretreatment-AD process. Results showed that the ARGs removal efficiency of AD itself was approximately 50.77%, and if these three sludge pretreatments were applied, the total ARGs removal efficiency of the whole pretreatment-AD process could be improved up to 52.50%–75.07%. The ultrasonic pretreatment was more efficient than alkaline and thermal hydrolysis pretreatments. Although thermal hydrolysis reduced ARGs obviously, the total ARGs rebounded considerably after inoculation and were only removed slightly in the subsequent AD process. Furthermore, it was found that the total ARGs concentration significantly correlated with the amount of 16S rRNA gene during the pretreatment and AD processes, and the bacteria carrying ARGs could be mainly affiliated with Proteobacteria.  相似文献   

8.
• Distribution of ARGs in decentralized sewage facilities were investigated. • Bacitracin-ARGs were most predominant ARGs in rural wastewater. • ARGs were identified in bacterial and viral community. • ARGs of rpoB, drfE, gyrA and parC were both correlated with bacteria and phages. • More attention should be paid to the risk of spreading ARG by phages. The distribution of antibiotic resistance genes (ARGs) has been intensively studied in large-scale wastewater treatment plants and livestock sources. However, small-scale decentralized sewage treatment facilities must also be explored due to their possible direct exposure to residents. In this study, six wastewater treatment facilities in developed rural areas in eastern China were investigated to understand their risks of spreading ARGs. Using metagenomics and network analysis tools, ARGs and bacterial and viral communities were identified in the influent (INF) and effluent (EFF) samples. The dominant ARGs belonged to the bacitracin class, which are different from most of municipal wastewater treatment plants (WWTPs). The dominant hosts of ARGs are Acidovorax in bacterial communities and Prymnesiovirus in viral communities. Furthermore, a positive relationship was found between ARGs and phages. The ARGs significantly correlated with phages were all hosted by specific genera of bacteria, indicating that phages had contributed to the ARG’s proliferation in sewage treatment facilities. Paying significant concern on the possible enhanced risks caused by bacteria, viruses and their related ARGs in decentralized sewage treatment facilities is necessary.  相似文献   

9.
The history of China’s municipal wastewater management is revisited. The remaining challenges in wastewater sector in China are identified. New concept municipal wastewater treatment plants are highlighted. An integrated plant of energy, water and fertilizer recovery is envisaged. China has the world’s largest and still growing wastewater sector and water market, thus its future development will have profound influence on the world. The high-speed development of China’s wastewater sector over the past 40 years has forged its global leading treatment capacity and innovation ability. However, many problems were left behind, including underdeveloped sewers and sludge disposal facilities, low sustainability of the treatment processes, questionable wastewater treatment plant (WWTP) effluent discharge standards, and lacking global thinking on harmonious development between wastewater management, human society and the nature. Addressing these challenges calls for fundamental changes in target design, policy and technologies. In this mini-review, we revisit the development history of China’s municipal wastewater management and identify the remaining challenges. Also, we highlight the future needs of sustainable development and exploring China’s own wastewater management path, and outlook the future from several aspects including targets of wastewater management, policies and technologies, especially the new concept WWTP. Furthermore, we envisage the establishment of new-generation WWTPs with the vision of turning WWTP from a site of pollutant removal into a plant of energy, water and fertilizer recovery and an integrated part urban ecology in China.  相似文献   

10.
• Quantitative global ARGs profile in dialysis water was investigated. • Totally 35 ARGs were found in the dialysis treatment train. • 29 ARGs (highest) were found in carbon filtration effluent. erm and mtrD-02 occurred in the final effluent. • The effluent was associated with health risks even after RO treatment. Dialysis water is directly related to the safety of hemodialysis patients, thus its quality is generally ensured by a stepwise water purification cascade. To study the effect of water treatment on the presence of antibiotic resistance genes (ARGs) in dialysis water, this study used propidium monoazide (PMA) in conjunction with high throughput quantitative PCR to analyze the diversity and abundance of ARGs found in viable bacteria from water having undergone various water treatment processes. The results indicated the presence of 35 ARGs in the effluents from the different water treatment steps. Twenty-nine ARGs were found in viable bacteria from the effluent following carbon filtration, the highest among all of the treatment processes, and at 6.96 Log (copies/L) the absolute abundance of the cphA gene was the highest. Two resistance genes, erm (36) and mtrD-02, which belong to the resistance categories macrolides-lincosamides-streptogramin B (MLSB) and other/efflux pump, respectively, were detected in the effluent following reverse osmosis treatment. Both of these genes have demonstrated the potential for horizontal gene transfer. These results indicated that the treated effluent from reverse osmosis, the final treatment step in dialysis-water production, was associated with potential health risks.  相似文献   

11.
Reviewed the change of ARGs and ARB in full-scale urban drinking water systems. Conventional processes are more promising than BAC process in ARGs removal. Mechanisms of ARGs enrichment and spread in BAC filter and DWDSs are discussed. Raise the need of future research on ARGs and ARB change in building plumbing systems. Antibiotic resistance in aquatic environment has become an important pollution problem worldwide. In recent years, much attention was paid to antibiotic resistance in urban drinking water systems due to its close relationship with the biosafety of drinking water. This review was focused on the mechanisms of antibiotic resistance, as well as the presence, dissemination and removal of antibiotic resistant bacteria (ARB) and antibiotic resistance genes (ARGs) in the urban drinking water system. First, the presence of ARB and ARGs in the drinking water source was discussed. The variation of concentration of ARGs and ARB during coagulation, sedimentation and filtration process were provided subsequently, in which filtration was proved to be a promising technology to remove ARGs. However, biological activated carbon (BAC) process and drinking water distribution systems (DWDSs) could be incubators which promote the antibiotic resistance, due to the enrichment of ARGs and ARB in the biofilms attached to the active carbon and pipe wall. Besides, as for disinfection process, mechanisms of the inactivation of ARB and the promotion of conjugative transfer of ARGs under chlorine, ozone and UV disinfection were described in detail. Here we provide some theoretical support for future researches which aim at antibiotic resistance controlling in drinking water.  相似文献   

12.
A two-stage BTF system was established treating odorous off-gas mixture from a WWTP. The two-stage BTF system showed resistance for the lifting load of H2S and VOSC. Miseq Illumina sequencing showed separated functional microbial community in BTFs. Avoiding H2S inhibition and enhancement of VOSC degradation was achieved. Key control point was discussed to help industrial application of the system. Simultaneous removal of hydrogen sulfide (H2S) and volatile organic sulfur compounds (VOSCs) in off-gas mixture from a wastewater treatment plant (WWTP) is difficult due to the occasional inhibitory effects of H2S on VOSC degradation. In this study, a two-stage bio-trickling filter (BTF) system was developed to treat off-gas mixture from a real WWTP facility. At an empty bed retention time of 40 s, removal efficiencies of H2S, methanethiol, dimethyl sulfide, and dimethyl disulfide were 90.1, 88.4, 85.8, and 61.8%, respectively. Furthermore, the effect of lifting load shock on system performance was investigated and results indicated that removal of both H2S and VOSCs was slightly affected. Illumina Miseq sequencing revealed that the microbial community of first-stage BTF contained high abundance of H2S-affinity genera including Acidithiobacillus (51.43%), Metallibacterium (25.35%), and Thionomas (8.08%). Analysis of mechanism demonstrated that first stage of BTF removed 86.1% of H2S, mitigating the suppression on VOSC degradation in second stage of BTF. Overall, the two-stage BTF system, an innovative bioprocess, can simultaneously remove H2S and VOSC.  相似文献   

13.
Antibiotic-resistant bacteria and antibiotic resistance genes are in water bodies. UV/chlorination method is better to remove ARGs than UV or chlorination alone. Research on UV/hydrogen peroxide to eliminate ARGs is forthcoming. UV-based photocatalytic processes are effective to degrade ARGs. Antibiotic-resistant bacteria (ARB) and antibiotic resistance genes (ARGs) have been recognized as one of the biggest public health issues of the 21st century. Both ARB and ARGs have been determined in water after treatment with conventional disinfectants. Ultraviolet (UV) technology has been seen growth in application to disinfect the water. However, UV method alone is not adequate to degrade ARGs in water. Researchers are investigating the combination of UV with other oxidants (chlorine, hydrogen peroxide (H2O2), peroxymonosulfate (PMS), and photocatalysts) to harness the high reactivity of produced reactive species (Clž·, ClOž·ž, Clž2·ž, žž·OH, and SOž4ž·€) in such processes with constituents of cell (e.g., deoxyribonucleic acid (DNA) and its components) in order to increase the degradation efficiency of ARGs. This paper briefly reviews the current status of different UV-based treatments (UV/chlorination, UV/H2O2, UV/PMS, and UV-photocatalysis) to degrade ARGs and to control horizontal gene transfer (HGT) in water. The review also provides discussion on the mechanism of degradation of ARGs and application of q-PCR and gel electrophoresis to obtain insights of the fate of ARGs during UV-based treatment processes.  相似文献   

14.
Green source Ep was extracted from marine alga waste. The molecule model structure of Ep was studied and constructed. PAC-Ep coagulation system improves the efficiency of removal efficiency. Synergistic effects between NPs and HA make a big difference to enhance efficiency. Mechanism is charge neutralization, hydrogen bonding and adsorbing-complexing Enteromorpha polysaccharide (Ep) extracted from alga a novel green coagulant aid for nanoparticles (NPs) and heavy metal ions removal and the structure of EP was intensively studied in this study. The integration of Ep with polyaluminum chloride (PAC-Ep) coagulants exhibited higher coagulation performance than that of the polyaluminum chloride (PAC) because of the negatively charged NPs suspension and humic aid (HA) solution. Significant high removal efficiencies of dissolved organic matter (94.1%), turbidity (99.3%) and Zn ions (69.3%) were achieved by the PAC-Ep coagulants. The dual-coagulation properties of PAC-Ep for different pollutants was based on multiple mechanisms, including (i) Al3+ charge neutralization; (ii) hydroxy aluminum hydroxyl bridging formed polynuclearhydroxy complexes bridge and sweep colloidal particles; (iii) adsorption and bridging of Ep chain for the NPs and heavy metal ions. Results indicated that the destabilization of colloid was induced by the coexisting HA and higher removal was achieved as ions adsorption was enhance in the presence of HA complexation. On the basis of that, the extraction of polysaccharide is a promising candidate for its high coagulation performance in water treatment.  相似文献   

15.
• UV/O3 process had higher TAIC mineralization rate than O3 process. • Four possible degradation pathways were proposed during TAIC degradation. • pH impacted oxidation processes with pH of 9 achieving maximum efficiency. • CO32– negatively impacted TAIC degradation while HCO3 not. • Cl can be radicals scavenger only at high concentration (over 500 mg/L Cl). Triallyl isocyanurate (TAIC, C12H15N3O3) has featured in wastewater treatment as a refractory organic compound due to the significant production capability and negative environmental impact. TAIC degradation was enhanced when an ozone(O3)/ultraviolet(UV) process was applied compared with the application of an independent O3 process. Although 99% of TAIC could be degraded in 5 min during both processes, the O3/UV process had a 70%mineralization rate that was much higher than that of the independent O3 process (9%) in 30 min. Four possible degradation pathways were proposed based on the organic compounds of intermediate products identified during TAIC degradation through the application of independent O3 and O3/UV processes. pH impacted both the direct and indirect oxidation processes. Acidic and alkaline conditions preferred direct and indirect reactions respectively, with a pH of 9 achieving maximum Total Organic Carbon (TOC) removal. Both CO32– and HCO3 decreased TOC removal, however only CO32– negatively impacted TAIC degradation. Effects of Cl as a radical scavenger became more marked only at high concentrations (over 500 mg/L Cl). Particulate and suspended matter could hinder the transmission of ultraviolet light and reduce the production of HO· accordingly.  相似文献   

16.
• SMX was mainly degraded by hydrolysis, isoxazole oxidation and double-bond addition. • Isoxazole oxidation and bond addition products were formed by direct ozonation. • Hydroxylated products were produced by indirect oxidation. • NOM mainly affected the degradation of SMX by consuming OH rather than O3. • Inhibitory effect of NOM on SMX removal was related to the components’ aromaticity. Sulfamethoxazole (SMX) is commonly detected in wastewater and cannot be completely decomposed during conventional treatment processes. Ozone (O3) is often used in water treatment. This study explored the influence of natural organic matters (NOM) in secondary effluent of a sewage treatment plant on the ozonation pathways of SMX. The changes in NOM components during ozonation were also analyzed. SMX was primarily degraded by hydrolysis, isoxazole-ring opening, and double-bond addition, whereas hydroxylation was not the principal route given the low maximum abundances of the hydroxylated products, with m/z of 269 and 287. The hydroxylation process occurred mainly through indirect oxidation because the maximum abundances of the products reduced by about 70% after the radical quencher was added, whereas isoxazole-ring opening and double-bond addition processes mainly depended on direct oxidation, which was unaffected by the quencher. NOM mainly affected the degradation of micropollutants by consuming OH rather than O3 molecules, resulting in the 63%–85% decrease in indirect oxidation products. The NOM in the effluent were also degraded simultaneously during ozonation, and the components with larger aromaticity were more likely degraded through direct oxidation. The dependences of the three main components of NOM in the effluent on indirect oxidation followed the sequence: humic-like substances>fluvic-like substances>protein-like substances. This study reveals the ozonation mechanism of SMX in secondary effluent and provides a theoretical basis for the control of SMX and its degradation products in actual water treatment.  相似文献   

17.
Specific second-order rate constants were determined for 5-FU and CAP with ozone. Reaction sites were confirmed by kinetics, Fukui analysis, and products. The olefin moiety was the main ozone reaction site for 5-FU and CAP. Carboxylic acids comprised most of the residual TOC for 5-FU. Ozonation removed the toxicity associated with 5-FU and products but not CAP. Anticancer drugs (ADs) have been detected in the environment and represent a risk to aquatic organisms, necessitating AD removal in drinking water and wastewater treatment. In this study, ozonation of the most commonly used antimetabolite ADs, namely 5-fluorouracil (5-FU) and its prodrug capecitabine (CAP), was investigated to determine reaction kinetics, oxidation mechanisms, and residual toxicity. The specific second-order rate constants between aqueous ozone and 5-FU, 5-FU, 5-FU2, CAP, and CAP were determined to be 7.07(±0.11)×104 M1·s1, 1.36(±0.06)×106 M1·s1, 2.62(±0.17)×107 M1·s1, 9.69(±0.08)×103 M1·s1, and 4.28(±0.07)×105 M1·s1, respectively; furthermore, the second-order rate constants for OH reaction with 5-FU and CAP at pH 7 were determined to be 1.85(±0.20)×109 M1·s1 and 9.95(±0.26)×109 M1·s1, respectively. Density functional theory was used to predict the main ozone reaction sites of 5-FU (olefin) and CAP (olefin and deprotonated secondary amine), and these mechanisms were supported by the identified transformation products. Carboxylic acids constituted a majority of the residual organic matter for 5-FU ozonation; however, carboxylic acids and aldehydes were important components of the residual organic matter generated by CAP. Ozone removed the toxicity of 5-FU to Vibrio fischeri, but the residual toxicity of ozonated CAP solutions exhibited an initial increase before subsequent removal. Ultimately, these results suggest that ozone is a suitable technology for treatment of 5-FU and CAP, although the residual toxicity of transformation products must be carefully considered.  相似文献   

18.
• Pore structure affects biologically activated carbon performance. • Pore structure determines organic matter (OM) removal mechanism. • Microbial community structure is related to pore structure and OM removal. Optimizing the characteristics of granular activated carbon (GAC) can improve the performance of biologically activated carbon (BAC) filters, and iodine value has always been the principal index for GAC selection. However, in this study, among three types of GAC treating the same humic acid-contaminated water, one had an iodine value 35% lower than the other two, but the dissolved organic carbon removal efficiency of its BAC was less than 5% away from the others. Iodine value was found to influence the removal of different organic fractions instead of the total removal efficiency. Based on the removal and biological characteristics, two possible mechanisms of organic matter removal during steady-state were suggested. For GAC with poor micropore volume and iodine value, high molecular weight substances (3500–9000 Da) were removed mainly through degradation by microorganisms, and the biodegraded organics (soluble microbial by-products,<3500 Da) were released because of the low adsorption capacity of activated carbon. For GAC with higher micropore volume and iodine value, organics with low molecular weight (<3500 Da) were more easily removed, first being adsorbed by micropores and then biodegraded by the biofilm. The biomass was determined by the pore volume with pore diameters greater than 100 μm, but did not correspond to the removal efficiency. Nevertheless, the microbial community structure was coordinate with both the pore structure and the organic removal characteristics. The findings provide a theoretical basis for selecting GAC for the BAC process based on its pore structure.  相似文献   

19.
• Hydrothermal treatment can greatly improve resource recovery from sewage sludge. • tCOD removal during WO was ~55% compared with ~23% after TH. • TOC solubilization during hydrothermal treatment followed first-order kinetics. • Solids and carbon balance confirmed loss of organics during thermal hydrolysis. • Reaction pathways for thermal hydrolysis and wet oxidation are proposed. We evaluated the effect of hydrothermal pretreatments, i.e., thermal hydrolysis (TH) and wet oxidation (WO) on sewage sludge to promote resource recovery. The hydrothermal processes were performed under mild temperature conditions (140°C–180°C) in a high pressure reactor. The reaction in acidic environment (pH= 3.3) suppressed the formation of the color imparting undesirable Maillard’s compounds. The oxidative conditions resulted in higher volatile suspended solids (VSS) reduction (~90%) and chemical oxygen demand (COD) removal (~55%) whereas TH caused VSS and COD removals of ~65% and ~27%, respectively at a temperature of 180°C. During TH, the concentrations of carbohydrates and proteins in treated sludge were 400–1000 mg/L and 1500–2500 mg/L, respectively. Whereas, WO resulted in solids solubilization followed by oxidative degradation of organics into smaller molecular weight carboxylic acids such as acetic acid (~400–500 mg/L). Based on sludge transformation products generated during the hydrothermal pretreatments, simplified reaction pathways are predicted. Finally, the application of macromolecules (such as proteins), VFAs and nutrients present in the treated sludge are also discussed. The future study should focus on the development of economic recovery methods for various value-added compounds.  相似文献   

20.
The discharge characteristics during the degradation of MNZ by DBD were investigated. Increasing the discharge frequency can promote the degradation of MNZ. MNZ removal reaches 99.1% at the initial concentration of 40 ppm within 120 min. Coexisting organic matter inhibits the degradation of MNZ. The energy efficiency of DBD for MNZ removal is higher than other technologies. Degradation of metronidazole (MNZ) which is a representative and stable antibiotic by dielectric barrier discharge (DBD) in an aqueous solution has been studied. Effects of initial MNZ concentration, solution pH and coexisting organics on the degradation were investigated. The results illustrated that increasing the input power and the discharge frequency can improve the removal of MNZ. At low initial concentration, the removal of MNZ can reach up to 99.1%. Acidic and neutral conditions are more favorable for MNZ removal than alkaline condition in the early stage of degradation. However, the difference in MNZ removal between those in acidic or neutral media and that in alkaline one could be neglected with prolonging of the treatment time. Therefore, this method can be applied to MNZ degradation with a wide pH range. Coexisting organic matter in water can attenuate the removal to some extent. This study could provide valuable references for the degradation of nitroimidazole antibiotics by DBD.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏