首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 281 毫秒
1.
Combined chemical and biological oxidation of penicillin formulation effluent   总被引:12,自引:0,他引:12  
Antibiotic formulation effluent is well known for its important contribution to environmental pollution due to its fluctuating and recalcitrant nature. In the present study, the chemical treatability of penicillin formulation effluent (average filtered COD(o)=830 mg/l; average soluble COD(o)=615 mg/l; pH(o)=6.9) bearing the active substances penicillin Amoxicillin Trihydrate (C(16)H(19)N(3)O(5)S.3H(2)O) and the beta-lactamase inhibitor Potassium Clavulanate (C(8)H(8)KNO(5)) has been investigated. For this purpose, the penicillin formulation effluent was subjected to ozonation (applied ozone dose=2500 mg/(lxh)) at varying pH (2.5-12.0) and O(3)+H(2)O(2) (perozonation) at different initial H(2)O(2) concentrations (=2-40 mM) and pH 10.5. According to the experimental results, the overall Chemical Oxygen Demand (COD) removal efficiency varied between 10 and 56% for ozonation and 30% (no H(2)O(2)) and 83% (20 mM H(2)O(2)) for the O(3)+H(2)O(2) process. The addition of H(2)O(2) improved the COD removal rates considerably even at the lowest studied H(2)O(2) concentration. An optimum H(2)O(2) concentration of 20 mM existed at which the highest COD removal efficiency and abatement kinetics were obtained. The ozone absorption rate ranged between 53% (ozonation) and 68% (perozonation). An ozone input of 800 mg/l in 20 min was sufficient to achieve the highest BOD(5)/COD (biodegradability) ratio (=0.45) and BOD(5) value (109 mg/l) for the pre-treated penicillin formulation effluent. After the establishment of optimum ozonation and perozonation conditions, mixtures of synthetic domestic wastewater+raw, ozonated and perozonated penicillin formulation effluent were subjected to biological activated sludge treatment at a food-to-microorganisms (F/M) ratio of 0.23 mg COD/(mg MLSSxd), using a consortium of acclimated microorganisms. COD removal efficiencies of the activated sludge process were 71, 81 and 72% for pharmaceutical wastewater containing synthetic domestic wastewater mixed with either raw, ozonated or perozonated formulation effluent, respectively. The ultimate COD value obtained after 24-h biotreatment of the synthetic domestic wastewater+pre-ozonated formulation effluent mixture was around 100 mg/l instead of 180 mg/l which was the final COD obtained for the wastewater mixture containing raw formulation effluent, indicating that pre-ozonation at least partially removed the non-biodegradable COD fraction of the formulation effluent.  相似文献   

2.
Large and repeated manure applications can exceed the P sorption capacity of soil and increase P leaching and losses through subsurface drainage. The objective of this study was to evaluate the fate of P applied with increasing N rates in dairy wastewater or poultry litter on grassland during a 4-yr period. In addition to P recovery in forage, soil-test phosphorus (STP) was monitored at depths to 180 cm in a Darco loamy sand (loamy, siliceous, semiactive, thermic Grossarenic Paleudults) twice annually. A split-plot arrangement of a randomized complete block design comprised four annual N rates (0, 250, 500, and 1000 kg ha(-1)) for each nutrient source on coastal bermudagrass [Cynodon dactylon (L.) Pers.] over-seeded with ryegrass (Lolium multiflorum L. cv. TAM90). Increasing annual rates of N and P in wastewater and poultry litter increased P removal in forage (P = 0.001). At the highest N rate of each nutrient source, less than 13% of applied P was recovered in forage. The highest N rates delivered 8 times more P in wastewater or 15 times more P in poultry litter than was removed in forage harvests during an average year. Compared with controls, annual P rates up to 188 kg ha(-1) in dairy wastewater did not increase STP concentrations at depths below 30 cm. In contrast, the highest annual P rate (590 kg ha(-1)) in poultry litter increased STP above that of controls at depth intervals to 120 cm during the first year of sampling. Increases in STP at depths below 30 cm in the Darco soil were indicative of excessive P rates that could contribute to nonpoint-source pollution in outflows from subsoil through subsurface drainage.  相似文献   

3.
Constructed wetlands (CW) usually require large land areas for treating wastewater. This study evaluated the feasibility of applying CW with less land requirement by operating a group of microcosm wetlands at a hydraulic retention time (HRT) of less than 4 d in southern Taiwan. An artificial wastewater, simulating municipal wastewater containing 200 mg L(-1) of chemical oxygen demand (COD), 20 mg L(-1) of NH4+-N (AN), and 20 mg L(-1) of PO4(3-)-P (OP), was the inflow source. Three emergent plants [reed, Phragmites australis (Cav.) Trin. ex Steud.; water primrose, Ludwigia octovalvis (Jacq.) P.H. Raven; and dayflower, Commelina communis L.] and two floating plants [water spinach, Ipomoea aquatica Forssk.; and water lettuce, Pistia stratiotes L.] plants were tested. The planted systems showed more nutrient removal than unplanted systems; however, the type of macrophytes in CW did not make a major difference in treatment. At the HRTs of 2 to 4 d, the planted system maintained greater than 72,80, and 46% removal for COD, AN, and OP, respectively. For AN and OP removal, the highest efficiencies occurred at the HRT of 3 d, whereas maximum removal rates for AN and OP occurred at the HRT of 2 d. Both removal rates and efficiencies were reduced drastically at the HRT of 1 d. Removals of COD, OP, and AN followed first-order reactions within the HRTs of 1 to 4 d. The efficient removals of these constituents obtained with HRT between 2 and 4 d indicated the possibility of using a CW system for wastewater treatment with less land requirement.  相似文献   

4.
We tested the effect of nutrient inputs from wastewater treatment plants (WWTPs) on stream nutrient retention efficiency by examining the longitudinal patterns of ammonium, nitrate, and phosphate concentrations downstream of WWTP effluents in 15 streams throughout Catalonia (Spain). We hypothesized that large nutrient loadings would saturate stream communities, lowering nutrient retention efficiency (i.e., nutrient retention relative to nutrient flux) relative to less polluted streams. Longitudinal variation in ambient nutrient concentration reflected the net result of physical, chemical, or biological uptake and release processes. Therefore, gradual increases in nutrient concentration indicate that the stream acts as a net source of nutrients to downstream environments, whereas gradual declines indicate that the stream acts as a net sink. In those streams where gradual declines in nutrient concentration were observed, we calculated the nutrient uptake length as an indicator of the stream nutrient retention efficiency. No significant decline was found in dilution-corrected concentrations of dissolved inorganic nitrogen (DIN) and phosphate in 40 and 45% of streams, respectively. In the remaining streams, uptake length (estimated based on the decline of nutrient concentrations at ambient levels) ranged from 0.14 to 29 km (DIN), and from 0.14 to 14 km (phosphate). Overall, these values are longer (lower retention efficiency) than those from nonpolluted streams of similar size, supporting our hypothesis, and suggest that high nutrient loads affect fluvial ecosystem function. This study demonstrates that the efficiency of stream ecosystems to remove nutrients has limitations because it can be significantly altered by the quantity and quality of the receiving water.  相似文献   

5.
The remediation of biodiesel wastewater was carried out using chemical and electrochemical techniques. Initially the fatty acid methyl esters (FAME or biodiesel) and free fatty acids (FFA) were chemically removed from the wastewater using three types of mineral acids, H(2)SO(4), HNO(3) and HCl, at different pH values within the range of 1.0-8.0. Optimally, approximately 24.3 ml/l of FAME/FFA were removed from the wastewater when using H(2)SO(4) to set a final pH of 2.5 for 7 min. All pollutant levels were markedly reduced during this step. That is, approximately 38.94%, 76.32% and 99.36% of COD, BOD5 and oil & grease were respectively removed. The acidic aqueous phase left after the removal of the FAME/FFA phase was then treated by chemical- and electro-coagulation processes. The results demonstrated that both investigated treatment processes were effective for treating wastewater from a biodiesel production plant. The chemical coagulation provided a lower operating cost (1.11 USD/m(3)) compared with the electro-coagulation process (1.78 USD/m(3)). However, the latter process provided a better quality of wastewater compared with the former process, with the exception of the BOD levels.  相似文献   

6.
Nutrient removal from domestic strength synthetic wastewater by an alternating pumped flow sequencing batch biofilm reactor (APFSBBR) was investigated in this laboratory study. The APFSBBR comprised two reactor tanks (Reactors 1 and 2) with two identical biofilm modules of vertical tubular plastic media with a high specific surface area, one in each tank. The APFSBBR was operated in cycles of four phases: fill, anaerobic, aerobic, and draw. During the fill phase, Reactor 1 was half-filled with domestic strength synthetic wastewater. During the subsequent anaerobic phase, most of the phosphorus release took place from the submerged biofilm in this reactor. In the aerobic phase, the wastewater was circulated by pumps between Reactors 1 and 2, resulting in denitrification at the start of the aerobic phase due to low oxygen concentrations, followed by nitrification and luxury uptake of phosphorus when oxygen concentrations increased. During the draw phase, Reactor 2 was half-emptied of the treated water. At the chemical oxygen demand (COD), total nitrogen (TN), and total phosphorus (TP) loading rates on the total biofilm area of 3.20 g COD, 0.33 g TN, and 0.06 g TP m(-2) d(-1), the removal efficiencies were 97, 85, and 92% for COD, TN, and TP, respectively.  相似文献   

7.
Biological treatment of landfill leachate usually results in low nutrient removals because of high chemical oxygen demand (COD), high ammonium-N content and the presence of toxic compounds such as heavy metals. Landfill leachate with high COD content was pre-treated by coagulation-flocculation with lime followed by air stripping of ammonia at pH=12. Nutrient removal from pre-treated leachate was carried out using a lab-scale sequencing batch reactor (SBR). Three different operations consisting of different numbers of steps were tested and their performances were compared. These operations were the three-step anaerobic (An)/anoxic (Ax)/oxic (Ox); the four-step (An/Ox/Ax/Ox), and the five-step (An/Ax/Ox/Ax/Ox) operations with total residence time of seven hours each. Experiments were carried out using three consecutive operations with a total cycle time of 21 h at a constant sludge age of 10 days. The lowest effluent nutrient levels were realized by using the five-step operation which resulted in effluent COD, NH4-N and PO4-P contents of 1,400, 107 and 65 mg l(-1), respectively, at the end of 21 h. Addition of domestic wastewater (1/1, v/v) and powdered activated carbon (PAC, 1 g l(-1)) to the pre-treated leachate improved nutrient removals in the five-step SBR operation, resulting in 75% COD, 44% NH4-N and 44% PO4-P removals after 21 hours of operation.  相似文献   

8.
Chlorate release into the environment occurs with its manufacture and use. Biological reduction of chlorate offers an attractive option to decrease this release. A hydrogen gas-lift reactor with microorganisms attached to pumice particles was used for the treatment of wastewater containing high concentrations of chlorate. The microorganisms used chlorate as an electron acceptor and hydrogen gas as a reducing agent. After a start-up period of only a few weeks, chlorate reduction rates of 3.2 mmol L(-1) h(-1) were achieved during continuous operation. During this period, a hydrogen consumption rate of 14.5 mmol L(-1) h(-1) was observed. Complete removal of chlorate was maintained at hydraulic retention times of 6 h. This study clearly demonstrates the potential of hydrogen gas-lift bioreactors for the treatment of chlorate-containing waste streams.  相似文献   

9.
In Ireland, no database detailing the design, influent loading rates or performance of constructed wetlands (CWs) exists. On account of this, they are designed without any protocol based on empirical data. The aim of this paper was to provide the first published data on the performance of free-water surface flow (FWSF) CWs treating primary and secondary-treated municipal wastewater, and agricultural dairy soiled water (DSW) in Ireland. In total, the performance of thirty-four FWSF CWs, comprising fourteen CWs treating primary-treated municipal wastewater, thirteen CWs treating secondary-treated municipal wastewater, and seven CWs treating DSW, were examined. In most CWs, good organic, suspended solids (SS) and nutrient removal was measured. At an average organic loading rate (OLR) of 10 and 9 g biochemical oxygen demand (BOD) m(-2) d(-1), CWs treating primary and secondary wastewater removed 95 and 84% of influent BOD. Constructed wetlands treating DSW had an average BOD removal of 98%. At average SS loading rates of 6 and 14 g m(-2) d(-1), CWs treating primary and secondary wastewater had a 96 and an 82% reduction, and produced a final effluent with a concentration of 14 and 13 mg L(-1). Constructed wetlands treating DSW produced a final effluent of 34 mg L(-1) (94% reduction). Similar to other studies, all CWs examined had variable performance in ammonium-N (NH(4)(+)-N) removal, with average removals varying between 37% (for CWs treating secondary wastewater) and 88% (for CWs treating DSW). Variable ortho-phosphorus (PO(4)(3-)-P) removal was attributable to different durations of operation, media types and loading rates.  相似文献   

10.
The management of dewatered wastewater sludge is a major issue worldwide. Sludge disposal to landfills is not sustainable and thus alternative treatment techniques are being sought. The objective of this work was to determine optimal mixing ratios of dewatered sludge with other organic amendments in order to maximize the degradability of the mixtures during composting. This objective was achieved using mixture experimental design principles. An additional objective was to study the impact of the initial C/N ratio and moisture contents on the co-composting process of dewatered sludge. The composting process was monitored through measurements of O(2) uptake rates, CO(2) evolution, temperature profile and solids reduction. Eight (8) runs were performed in 100 L insulated air-tight bioreactors under a dynamic air flow regime. The initial mixtures were prepared using dewatered wastewater sludge, mixed paper wastes, food wastes, tree branches and sawdust at various initial C/N ratios and moisture contents. According to empirical modeling, mixtures of sludge and food waste mixtures at 1:1 ratio (ww, wet weight) maximize degradability. Structural amendments should be maintained below 30% to reach thermophilic temperatures. The initial C/N ratio and initial moisture content of the mixture were not found to influence the decomposition process. The bio C/bio N ratio started from around 10, for all runs, decreased during the middle of the process and increased to up to 20 at the end of the process. The solid carbon reduction of the mixtures without the branches ranged from 28% to 62%, whilst solid N reductions ranged from 30% to 63%. Respiratory quotients had a decreasing trend throughout the composting process.  相似文献   

11.
Land application of wastewater has become an important disposal option for food-processing plants operating year-round. However, there are concerns about nutrient leaching from winter wastewater application on frozen soils. In this study, P and N leaching were compared between nongrowing season application of tertiary-treated wastewater plus growing season application of partially treated wastewater (NGS) vs. growing season application of partially treated wastewater (GS) containing high levels of soil P. As required by the Minnesota Pollution Control Agency (MPCA), the wastewater applied to the NGS fields during October through March was treated such that it contained < or =6 mg L(-1) total phosphorus (TP), < or =10 mg L(-1) NO3-N, and < or =20 mg L(-1) total Kjeldahl nitrogen (TKN). The only regulation for wastewater application during the growing season (April through September) was that cumulatively it did not exceed the agronomic N requirements of the crop in any sprayfield. Application of tertiary-treated wastewater during the nongrowing season plus partially treated wastewater during the growing season did not significantly increase NO3-N leaching compared with growing season application of nonregulated wastewater. However, median TP concentration in leachate was significantly higher from the NGS (3.56 mg L(-1)) than from the GS sprayfields (0.52 mg L(-1)) or nonirrigated sites (0.52 mg L(-1)). Median TP leaching loss was also significantly higher from the NGS sprayfields (57 kg ha(-1)) than from the GS (7.4 kg ha(-1)) or control sites (6.9 kg ha(-1)). This was mainly due to higher hydraulic loading from winter wastewater application and limited or no crop P uptake during winter. Results from this study indicate that winter application of even low P potato-processing wastewater to high P soils can accelerate P leaching. We conclude that the regulation of winter wastewater application on frozen soils should be based on wastewater P concentration and permissible loading. We also recommend that winter irrigation should take soil P saturation into consideration.  相似文献   

12.
选用以曝气生物流化池(ABFT)技术为核心、辅助以物理化学方法的工业化技术,对兰州石化公司高氨氮污水和高浓度有机废水进行了处理。处理结果显示:外排废水监测项目中pH值、悬浮物、COD、BOD5、氨氮、石油类、硫化物、氰化物、挥发酚的平均浓度均低于污水综合排放标准(GB8978-1996)的一级标准,其中:氨氮值仅为0.412mg/L,COD值为63.87mg/L。对COD、氨氮、硫化物、挥发酚、悬浮物等的去除率达到90%以上,石油类和BOD5的去除率也达到75%以上,取得了良好的效果。  相似文献   

13.
Bentonite clay has been used for the adsorption of Fe(II) from aqueous solutions over a concentration range of 80-200 mg/l, shaking time of 1-60 min, adsorbent dosage from 0.02 to 2 g and pH of 3. The process of uptake follows both the Langmuir and Freundlich isotherm models and also the first-order kinetics. The maximum removal (>98%) was observed at pH of 3 with initial concentration of 100 mg/l and 0.5 g of bentonite. The efficiency of Fe(II) removal was also tested using wastewater from a galvanized pipe manufacturing industry. More than 90% of Fe(II) can be effectively removed from the wastewater by using 2.0 g of the bentonite. The effect of cations (i.e. zinc, manganese, lead, cadmium, nickel, cobalt, chromium and copper) on the removal of Fe(II) was studied in the concentration range of 10-500 mg/l. All the added cations reduced the adsorption of Fe(II) at high concentrations except Zn. Column studies have also been carried out using a certain concentration of wastewater. More than 99% recovery has been achieved by using 5 g of the bentonite with 3M nitric acid solution.  相似文献   

14.
The effect of using ground tire rubber (GTR) as an adsorptive material in the removal of a 2:1:1 weight mixture of n-butyl acetate, toluene and m-xylene by using a peat biofilter under different intermittent conditions was investigated. The performance of two identical size biofilters, one packed with fibrous peat alone and the other with a 3:1 (vol) fibrous peat and GTR mixture, was examined for a period of four months. Partition coefficients of both materials were measured. Values of 53, 118 and 402 L kg(-1) were determined for n-butyl acetate, toluene and m-xylene in peat, respectively; and values of 40, 609 and 3035 L kg(-1) were measured for the same compounds in GTR. Intermittent load feeding of 16 h per day, 5 days per week working at an EBRT of 60 s and an inlet VOC concentration of 0.3 g C m(-1), resulted in removal efficiencies higher than 90% for both biofilters, indicating that the addition of GTR did not adversely affect the behavior of the bioreactor. Full removal of n-butyl acetate was obtained for both biofilters. GTR improved the removal of the aromatics in the first part of the biofilter, facilitating lower penetration of the toluene and m-xylene into the bed. A 31-day starvation period was applied and intermittent operation subsequently restarted. In both biofilters, high removal efficiencies after a re-acclimation period of two days were achieved. A shock loading test related to 1-h peaks of three- and four-fold increases in its baseline concentration (0.30 g C m(-3)) was applied in both biofilters. For the biofilter packed with the peat and GTR mixture, attenuation greater than 60% was observed in the maximum outlet concentration when compared to the biofilter packed with peat alone.  相似文献   

15.
This paper investigated the biodegradation kinetics of 4-chlorophenol (4-CP) and 2,4-dichlorophenol (2,4-DCP) separately in batch reactors and mixed in sequencing batch reactors (SBRs). Batch reactor experiments showed that both 4-CP and 2,4-DCP began to inhibit their own degradation at 53 and 25 mg l(-1), respectively, and that the Haldane equation gave a good fit to the experimental data because r(2) values were higher than 0.98. The maximum specific degradation rates (q(m)) were 130.3 and 112.4 mg g(-1) h for 4-CP and 2,4-DCP, respectively. The values of the half saturation (K(s)) and self-inhibition constants (K(i)) were 34.98 and 79.74 mg l(-1) for 4-CP, and 13.77 and 44.46 mg l(-1) for 2,4-DCP, respectively. The SBR was fed with a mixture of 220 mg l(-1) of 4-CP, 110 mg l(-1) of 2,4-DCP, and 300 mg l(-1) of peptone as biogenic substrate at varying feeding periods (0-8h) to evaluate the effect of feeding time on the performance of the SBR. During SBR operation, in addition to self-inhibition, 4-CP degradation was strongly and competitively inhibited by 2,4-DCP. The inhibitory effects were particularly pronounced during short feeding periods because of higher chlorophenol peak concentrations in the reactor. The competitive inhibition constant (K(ii)) of 2,4-DCP on 4-CP degradation was 0.17 mg l(-1) when the reactor was fed instantaneously (0 h feeding). During longer feedings, increased removal/loading rates led to lower chlorophenol peak concentrations at the end of feeding. Therefore, in multi-substrate systems feeding time plus reaction time should be determined based on both degradation kinetics and substrate interaction. During degradation, the meta cleavage of 4-chlorocatechol resulted in accumulation of a yellowish color because of the formation of 5-chloro-2-hydroxymuconic semialdehyde (CHMS), which was further metabolized. Isolation and enrichment of the chlorophenols-degrading culture suggested Pseudomonas sp. and Pseudomonas stutzeri to be the dominant species.  相似文献   

16.
The passive nutrient flux meter (PNFM) is introduced for simultaneous measurement of both water and nutrient flux through saturated porous media. The PNFM comprises a porous sorbent pre-equilibrated with a suite of alcohol tracers, which have different partitioning coefficients. Water flux was estimated based on the loss of loaded resident tracers during deployment, while nutrient flux was quantified based on the nutrient solute mass captured on the sorbent. An anionic resin, Lewatit 6328 A, was used as a permeable sorbent and phosphate (PO4(3-)) was the nutrient studied. The phosphate sorption capacity of the resin was measured in batch equilibration tests as 56 mg PO4(3-) g(-1), which was determined to be adequate capacity to retain PO4(3-) loads intercepted over typical PNFM deployment periods in most natural systems. The PNFM design was validated with bench-scale laboratory tests for a range of 9.8 to 28.3 cm d(-1) Darcy velocities and 6 to 43 h deployment durations. Nutrient and water fluxes measured by the PNFM averaged within 6 and 12% of the applied values, respectively, indicating that the PNFM shows promise as a tool for simultaneous measurement of water and nutrient fluxes.  相似文献   

17.
Subsurface tile drain flows can be a major s ource of nurient loss from agricultural landscapes. This study quantifies flows and nitrogen and phosphorus yields from tile drains at three intensively grazed dairy pasture sites over 3- to 5-yr periods and evaluates the capacity of constructed wetlands occupying 0.66 to 1.6% of the drained catchments too reduce nutrient loads. Continuous flow records are combined with automated flow-proportional sampling of nutrient concentrations to calculate tile drain nutrient yields and wetland mass removal rates. Annual drainage water yields rangedfrom 193 to 564 mm (16-51% of rainfall) at two rain-fed sites and from 827 to 853 mm (43-51% of rainfall + irrigation) at an irrigated site. Annually, the tile drains exported 14 to 109 kg ha(-1) of total N (TN), of which 58 to 90% was nitrate-N. Constructed wetlands intercepting these flows removed 30 to 369 gTN m(-2) (7-63%) of influent loadings annually. Seasonal percentage nitrate-N and TN removal were negatively associated with wetland N mass loadings. Wetland P removal was poor in all wetlands, with 12 to 115% more total P exported annually overall than received. Annually, the tile drains exported 0.12 to 1.38 kg ha of total P, of which 15 to 93% was dissolved reactive P. Additional measures are required to reduce these losses or provide supplementary P removal. Wetland N removal performance could be improved by modifying drainage systems to release flows more gradually and improving irrigation practices to reduce drainage losses.  相似文献   

18.
Treatment of low-strength soluble wastewater (COD approximately 500 mg/L) was studied using an eight chambered anaerobic baffled reactor (ABR). At pseudo steady-state (PSS), the average total and soluble COD values (COD(T) and COD(S)) at 8h hydraulic retention time (HRT) were found to be around 50 and 40 mg/L, respectively, while at 10h HRT average COD(T) and COD(S) values were of the order of 47 and 37 mg/L, respectively. COD and BOD (3 day, 27 degrees C) removal averaged more than 90%. Effluent conformed to Indian standards laid down for BOD (less than 30 mg/L). Reactor effluent characteristics exhibited very low values of standard deviation indicating excellent reactor stability at PSS in terms of effluent characteristics. Based on mass balance calculations, more than 60% of raw wastewater COD was estimated to be recovered as CH(4) in the gas phase. Compartment-wise profiles indicated that most of the BOD and COD got reduced in the initial compartments only. Sudden drop in pH (7.8-6.7) and formation of volatile fatty acids (VFA) (53-85 mg/L) were observed in the first compartment due to acidogenesis and acetogenesis. The pH increased and VFA concentration decreased longitudinally down the reactor. Residence time distribution (RTD) studies revealed that the flow pattern in the ABR was neither completely plug-flow nor perfectly mixed. Observations from scanning electron micrographs (SEM) suggest that distinct phase separation takes place in an ABR.  相似文献   

19.
The literature has paid scarce attention to the modeling of the denitrification-anaerobic digestion process in packed bed biofilm tubular reactors used to treat wastewater. The present study obtained a steady-state model for industrial salmon fishery wastewater treatment in a biofilm tubular reactor, including pH as a variable and the effect of biomass on hydrolysis. The axial profile of the reactor components and process efficiency were predicted with deviations below 6%. The optimal operating zone for the process was found at hydraulic retention time (HRT)>1.5d and inlet protein concentration (S(prot,0))<3000 mgTOCL(-1). Based on our results, we concluded that the removal of organic matter and nitrogen compounds depended mainly on HRT. The effluent pH was mainly affected by the C/N ratio, where a decrease increases pH. Organic matter removal was related with the anaerobic digestion process, while denitrification influenced mostly nitrate and nitrite removal.  相似文献   

20.
ABSTRACT: A comparison of municipal wastewater treatment plant (WWTP) and nonpoint source nutrient loads to Wisconsin's 14,927 inland lakes was performed. Only 65 of the 2,925 Wisconsin lakes having surface areas of at least eight ha and a maximum depth of at least 2.4 m had one or more WWTP's located within 40 km upstream; 99 of Wisconsin's 477 WWTP's were identified to be upstream of these 65 lakes. WWTP total nitrogen and total phosphorus loads to these 65 lakes were estimated using per capita influent loads and removal efficiencies based on wastewater treatment types. Nonpoint source nutrient loads were calculated utilizing nutrient export coefficients derived specifically for Wisconsin. Total nitrogen inputs to the lakes were dominated by nonpoint sources. The effectiveness of various phosphorus control programs to produce water quality improvements visible to the public was estimated to be as follows (going from most to least effective): municipal phosphorus removal and agricultural reductions, municipal phosphorus removal alone, agricultural reduction plus phosphate detergent ban, agricultural reductions alone, and phosphate detergent ban alone. The last option would not be expected to produce water quality improvement visible to the public in any Wisconsin lakes. The differences between the distributions in Wisconsin of population and inland lakes highlights the need to consider regional characteristics in any statewide water quality management plan.  相似文献   