首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 656 毫秒
1.
This paper describes a methodology used for designing louvered fins. Louvered fins are commonly used in many compact heat exchangers to increase the surface area and initiate new boundary layer growth. Detailed measurements can be accomplished with computational models of these louvered fins to gain a better understanding of the flow field and heat distribution. The particular louver geometry studies for this work have a louver angle of 23° and fin count of 17 fpi.

The flow and heat transfer characteristics for three-dimensional mixed convection flows in a radiator flat tube with louvered fins are analyzed numerically. A three-dimensional model is developed to investigate flow and conjugate heat transfer in the copper-based car radiator. The model was produced with the commercial program FLUENT. The theoretical model has been developed and validated by comparing the predictions of the model with available experimental data. The thermal performance and temperature distribution for the louvered fins were analyzed and a procedure for optimizing the geometrical design parameter is presented.

One fin specification among the various flat tube exchangers is recommended by first considering the heat transfer and pressure drop. The effects of variation of coolant flow conditions and external air conditions on the flow and the thermal characteristics for the selected radiator are investigated also. The results will be used as fundamental data for tube design by suggesting specifications for car radiator tubes.  相似文献   

2.
A model is developed to predict the evaporative heat transfer coefficient in a horizontal tube-falling evaporator and has been applied to evaluate overall performance of a desalination unit. Performance variation with different parameters like operation temperature, type of water distribution system, mass flow rate of distilled water inside the exchanger are analyzed. It has been observed that the model is able to predict the trends of heat transfer characteristics of the evaporator reasonably well. However, at low liquid film flow rate conditions, the model overpredicts the heat transfer characteristics marginally. In order to improve the evaporative exchanger performance, it is observed that preheating of the liquid film before injection into the evaporator is desirable. Calculations are also performed to estimate the value of overall heat transfer coefficient for a typical desalination unit.  相似文献   

3.
Abstract

In this work, gas flow and heat transfer have been numerically investigated and analyzed for both cathode/anode ducts of proton exchange membrane (PEM) fuel cells. The simulation is conducted by solving a set of conservation equations for the whole domain consisting of a porous medium, solid structure, and flow duct. A generalized extended Darcy model is employed to investigate the flow inside the porous layer. This model accounts for the boundary-layer development, shear stress, and microscopic inertial force as well. Effects of inertial coefficient, together with permeability, effective thermal conductivity, and thickness of the porous layer on gas flow and heat transfer are investigated.  相似文献   

4.
Heat pipe cooling is widely used in computer processors. Advances in microprocessor technology have resulted in reduced heat transfer surface area. Maintaining an efficient cooling process is therefore challenging. The main goal of this experimental study is to perform a parametric study on heat pipe performance using nanofluids. Nanofluids of 1 and 3 vol% of alumina nanoparticles of 20–50 nm diameters in deionized water versus deionized water as a base fluid were considered in the present study. The nanofluids are prepared in our laboratory using two-step method. The nanofluids thermal properties are measured to confirm the properties enhancement that could indicate a corresponding performance enhancement of the heat pipe. A 10 mm inner diameter, 200 mm long brass tube with 50 mm long evaporator, and 50 mm long water cooled condenser were used. Heat pipe wall temperature is reduced with nanofluids as is the temperature difference between the evaporator and condenser. The thermal diffusivity of the nanofluids is increased by 10%. The pipe pressure in case of deionized water was higher than the corresponding one for the nanofluids by 20–32%.  相似文献   

5.
The effect of heat resistance and heat leakage on the optimal performance of finite time heat engines is investigated in this paperbased on a generalized heat transfer law q ∞ Δ(Tn). The analytical relation between optimal power output and efficiency for steady-state flow irreversible heat engines is derived. The analysis includes the optimal performance characteristics of several types of heat engines with different loss item and different heat transfer laws. A numerical example is provided for illustrating the power output versus efficiency characteristics. Results shown that the heat transfer law does affect the performance of these heat engines.  相似文献   

6.
The Influence of mixed and pure working fluids on the performance of organic Rankine cycles (ORCs) is discussed. Specifically, the performance of mixed and pure working fluids is analyzed based on certain characteristics of low-temperature heat source and heat sink. A method of selecting binary zeotropic mixed working fluids that match with different heat sinks is introduced. Thermodynamic processes of ORCs for various heat sources are simulated in Matlab. The performance characteristics of pure and mixed working fluids are compared under different inlet temperatures and temperature gradients of sensible heat sources. The results demonstrate that when the initial temperature of a heat source is lower and its temperature gradient is higher, and the temperature gradient of the heat sink is higher, mixed working fluids have better performance than pure working fluids. However, for the opposite heat source and heat sink situations, pure working fluids perform better. Mixtures with low critical temperature components exhibit the best performance among all working fluids when the temperature gradient of the heat source is large. The analysis also shows that introduction of a recuperator may reduce the cycle efficiency when the heat source temperature is low and the temperature gradient of the heat source is large.  相似文献   

7.
This article presents a heat dynamic model for prediction of the indoor temperature in an office building. The model has been used in several flexible load applications, where the indoor temperature is allowed to vary around a given reference to provide power system services by shifting the heating of the building in time. This way the thermal mass of the building can be used to absorb energy from renewable energy source when available and postpone heating in periods with lack of renewable energy generation. The model is used in a model predictive controller to ensure the residential comfort over a given prediction horizon.  相似文献   

8.
In this communication, a new design of solar-energy-based water distillation cum drying unit with parabolic reflector has been designed, fabricated, and tested. Bitter gourd and potato slices are chosen as a drying commodity. Thermal performance of the developed system has been evaluated based on the experimental results and using linear regression analysis. Heat transfer coefficients (convective, evaporative, and radiative) for solar distillation system have been observed to be 2.48–4.09, 13.25–52.38, and 8.75–9.66 W/m2°C, respectively. Overall thermal efficiency and exergy efficiency for the distillation system has been found to be 18.77% and 1.2%, respectively. The convective heat transfer coefficient for potato slices are observed higher for initial hours and decreases as the day progresses. The average convective heat transfer coefficients for bitter gourd and potato slices have been observed as 2.18 and 5.04 W/m2°C, respectively. Experimental error in terms of percent uncertainty for bitter gourd and potato slices are found to be 42.93% and 37.06%, respectively. The present design of solar distillation and drying in a single unit could be beneficial for the development of remote, arid, and rural areas.  相似文献   

9.
Artificially roughened solar air heater has been topic in research for the last 30 years. Prediction of heat transfer and fluid flow processes of an artificially roughened solar air heater can be obtained by three approaches: theoretical, experimental, and computational fluid dynamics (CFD). This article provides a comprehensive review of the published literature on the investigations of artificially roughened solar air heater. In the present article, an attempt has been made to present holistic view of various roughness geometries used for creating artificial roughness in solar air heater for heat transfer enhancement. This extensive review reveals that quite a lot of work has been reported on design of artificially roughened solar air heater by experimental approach but only a few studies have been done by theoretical and CFD approaches. Finally this article presents a comparative study of thermo-hydraulic performance of 21 different types of artificial roughness geometries attached on the absorber plate of solar air heater in terms of thermo-hydraulic performance parameter. Heat transfer and friction factor correlations developed by various investigators for different types of artificially roughened solar air heaters have also been reported in this article.  相似文献   

10.
An experimental study has been carried out to analyze the effect of inclined ribs used as roughness element on heat transfer along its friction characteristics. The roughness parameters include relative roughness pitch (P/e) ranges from 4–16, relative roughness height (e/Dh) ranges from 0.021–0.043 and angle of attack (α) ranges from 30° to 75°. The Reynolds number (Re) lies in the range of 4500–28000. The heat transfer and friction factor data obtained from the experiment and it is compared with the data obtained from smooth duct under the same conditions. Considerable augmentation was observed in heat transfer and friction over the smooth duct. Correlation was also developed for Nusselt number (Nu) and friction factor (f) as a function of roughness and flow parameter.  相似文献   

11.
An untreated sewage source heat pump system directly makes use of the urban raw sewage instead of that treated by a sewage plant. At present In China, most systems adopt the indirect mode for avoiding the harmful effect of the sewage on the heat pump unit. In this article a direct-mode untreated sewage source heat pump system, which shows less theoretical analysis of the mathematical model, is theoretically designed and analyzed to simulate the system dynamic characteristics in the heating mode. The results show that the system COP changes from 4.1 to 3.4 and the heating capacity from 9.5 to 15.3 kW when the sewage inlet temperature is 12°C and the frequency increases from 18 to 32 HZ. The condenser heat-transfer coefficient increases with the frequency reducing while the change trend of evaporator heat-transfer coefficient is the opposite. The highest values of them are 303 and 1617 W.m?2?K?1, respectively. The frequency control simulation supplies the operation adjustment with theoretical instructions and some reference values.  相似文献   

12.
在高低温低气压试验中,由于空气稀薄,其温度均匀性试验已经无法用空气对流来实现了,只能通过的辐射和传导来实现和达到试验温度的均匀。在这种试验状况下,往往试验所得的温度、湿度的均匀性偏差很大。要实现较好的温度均匀性十分困难。我们将高真空领域中的热沉技术即辐射换热方式,运用到高(低)温低气压试验箱中,通过多个几何平面的辐射和传导,达到较为理想的试验参数。  相似文献   

13.
ABSTRACT

In this study, a three-dimension (3D) computational model was proposed to investigate the flow and heat transfer characteristics of the intake grilles of two different fuel cell vehicles. The models of the intake grilles were constructed according to the actual sizes of two vehicles, namely, Roewe 950 and Toyota Mirai, considering the heat dissipation unit to simplify the heat transfer model of the vehicle. The results showed that relative to Roewe 950, Mirai intake air flow rate was approximately 10% higher, the heat transfer capacity was approximately 7% higher, and the intake grille area was larger. The coolant outlet temperature of Mirai was lower than that of Roewe 950, which was beneficial for the long term and stable operation of a fuel cell. This comparative study provided guidance for the intake grille and radiator design of fuel cell vehicles. The only difference between fuel cell vehicles on the market and conventional vehicles was that in the former, the internal combustion engine was replaced with a fuel cell stack, which had insufficient heat transfer capacity because of the reducing temperature difference. Increasing the intake grille area and the heat exchange capacity of the radiator were the key issues for the development of fuel cell vehicles. In this study, an optimal window opening angle of the radiator fin of 23° provided a maximal heat transfer coefficient.  相似文献   

14.
International concern about the environmental implications of climate change coupled with increasing demand for energy to fuel modern society has lead to growing interest in using renewable energy sources as alternatives to conventional sources. The work presented in this paper compares two types of solar collector integrated into louvred shading devices. In addition to protecting glazed spaces in buildings from excessive solar gain, the collector would provide the flexibility to produce systems customized for collecting heat over a temperature-range appropriate to particular building services applications at various climates/locations. This would allow considerable savings to be made in primary energy consumption and lead to a reduction in global warming impact. Two solar absorbers, based on different techniques of heat exchange, were tested experimentally. The first was based on a direct heat exchange technique, and the second used heat pipe technology. Various comparisons were made and it was concluded that the heat pipe solar louvre collector was the preferred device.  相似文献   

15.
城市热岛效应的研究模型   总被引:6,自引:0,他引:6  
卢曦 《环境技术》2003,21(5):43-46
城市热岛不但影响城市气候,而且严重影响城市的大气环境,城市发展的多样性决定了城市热岛的复杂性、研究模型的多样性。本文通过对城市热岛常用的研究模型进行了分析、比较,为城市热岛研究模型的选择和进一步研究城市热岛的机理以及城市热岛对城市环境的影响提供了参考依据。  相似文献   

16.
Abstract

This article describes a novel flat plate heat-pipe solar collector, namely, the hybrid heat-pipe solar collector. An analytical model has been developed to calculate the collector efficiency as well as simulate the heat transfer processes occurring in the collector. The effects of heat pipes/absorber, top cover, flue gas channel geometry, and flue gas temperature and flow rate, on the collector efficiency were investigated based on three modes of operation, i.e., solar only operation, solar/exhaust gas combined, and solar, exhaust gas and boiler combined. Experimental testing of the collector was also carried out for each of these modes of operation under real climatic conditions. The results were used to estimate the efficiency of the collector and determine the relation between the efficiency and general external parameter. The modeling and experimental results were compared and a correlation factor was used to modify the theoretical predictions. It was found that the efficiency of the collector was increased by about 20–30% compared to a conventional flat-plate heat pipe solar collector.  相似文献   

17.
The performance characteristics of a solar air heater can effectively be improved by providing artificial roughness in the form of protrusions and dimples of various shapes, sizes, and orientations on the underside of heated surface. An extensive literature review on artificial roughness elements has been carried and the correlations developed for heat transfer and friction factor for roughened solar air collector have been discussed and presented in this paper. The performance parameter has also been computed and compared with various kinds and shapes of roughness geometries using correlations developed by various investigators. The optimum values of the roughness parameters obtained by several investigators have also been discussed.  相似文献   

18.
The paper presents the novel design of double glazing helical coil solar cavity receiver for solar thermal applications. Performance model has been developed for the experimental setup based on energy balance equations. The results obtained were compared with horizontal tube receiver for the same experimental setup. The result shows that the 87.96% improvement in the convective heat transfer coefficient for the double glazing helical coil solar cavity receiver. Maximum conversion efficiency achieved is 21% more than that would be obtained for horizontal tube receiver. This paper also investigates how the quality of vacuum degraded with the temperature of the glass cover.  相似文献   

19.
Abstract: A numerical model has been developed to simulate the hydraulic and heat transfer properties of a stormwater detention pond, as part of a simulation tool to evaluate thermal pollution of coldwater streams from stormwater runoff. The model is dynamic (unsteady) and based on principles of fluid mechanics and heat transfer. It is driven by hourly weather data, and specified inflow rates and temperatures. To calibrate and validate the pond model field data were collected on a commercial site in Woodbury, Minnesota. The relationship between pond inflow and outflow rates to precipitation was effectively calibrated using continuously recorded pond levels. Algorithms developed for surface heat transfer in lakes were found to be applicable to the pond with some modification, resulting in agreement of simulated and observed pond surface temperature within 1.0°C root mean square error. The use of an unshaded pond for thermal mitigation of runoff from paved surfaces was evaluated using the pond model combined with simulated runoff from an asphalt parking lot for six years of observed rainfall events. On average, pond outflow temperature was 1.2°C higher than inflow temperature, but with significant event‐to‐event variation. On average, the pond added heat energy to runoff from an asphalt parking lot. Although the pond added total heat energy to runoff, it did reduce the rate of heat outflow from the pond by an order of magnitude due to reductions in volumetric outflow rate compared with the inflow rate. By reducing the rate of heat flow, the magnitude of temperature impacts in a receiving stream were also reduced, but the duration of impacts was increased.  相似文献   

20.
Conventional solar photovoltaic (PV) module converts the light component of solar radiation into electrical power, and heat part is absorbed by module increasing its operating temperature. Combined PV module and heat exchanger generating both electrical and thermal powers is called as hybrid photovoltaic/thermal (PV/T) solar system. The paper presents the design of a PV/T collector, made with thin film PV technology and a spiral flow absorber, and a simulation model, developed through the system of several mathematical equations, to evaluate the performance of PV/T water collectors. The effect of various parameters on the thermal and electrical efficiency has been investigated to obtain optimum combination of parameters. Finally, a numerical simulation has been carried out for the daily and annual yield of the proposed PV/T collector, and comparison with a standard PV module is discussed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏