首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 72 毫秒
1.
Modeling houses as two coupled chambers, namely, the living area and basement, predicts more accurately the total indoor radon source flux from building materials and geology than a one-chamber model in houses with disparate radon concentrations. Three regional surveys found mean radon concentration ratios between basement and living area to range from 1.4 to 4.2, implying weak interchamber coupling in most cases. The invariability of second-order system parameters under steady infiltration but different initial conditions confirms the adequacy of the two-chamber model. The presence of a characteristic radon source flux was detected within the basements of two houses, in one case across different infiltration, coupling, and initial conditions. One-chamber models fit to two-chamber tracer gas data in one house show a source flux variation of a factor of 6 across changing coupling, while the two-chamber source flux variation was only a factor of 1.5. A substantial fraction of the apparent one-chamber living area source flux in these cases is the variable convective radon flux from the basement. The technique is not sensitive enough to detect living area source fluxes if either the interchamber coupling is strong or if the basement source flux is substantially larger.  相似文献   

2.
Radon gas emanating from underground can spread to adjoining closed areas. It can concentrate and reach levels which represent a risk to people's health. It is well known that radon presence in most areas depends mainly on the area's geological features. Indoor radon concentrations further depend on the type of structure, construction materials and the technology used for the building. Therefore, indoor radon monitoring is of primary importance for deciding whether remedial measures are to be adopted for reducing harmful concentrations. This approach has been tried by measuring radon concentration in an experimental building situated in Milan (Italy). This building situated in a geological area that is considered at low radon risk. The results were obtained after analysing radon concentration in indoor rooms, crawl spaces, soil gas and in the atmosphere outside and by measuring before and after adoption of remedial measures. The study shows that improper building design can give rise to higher indoor radon accumulation even in an area of poor radon exhalation. Furthermore, the results enable quantification of the effectiveness of the remedial measures.  相似文献   

3.
To quantify the effectiveness of Sub-Slab Depressurisation, widely used in the United Kingdom (U.K.) to mitigate indoor radon gas levels in residential properties, a study was made of radon concentration data collected from a set of 170 homes situated in Radon Affected Areas in Northamptonshire and neighbouring counties, remediated using conventional sump/pump technology. A high incidence of satisfactory remediation outcomes was achieved, with 100% of the houses remediated demonstrating post-remediation radon concentrations below the U.K. domestic Action Level of 200 Bq m(-3), while more than 75% of the sample exhibited radon mitigation factors (defined as the ratio of radon concentrations following and prior to remediation) <0.2. Two systematic trends are identified. Firstly, absolute radon concentration reduction following remediation is directly proportional to initial radon concentration, with a mean reduction factor of 0.96 and a residual component of around 75 Bq m(-3). Secondly, houses with lower initial radon concentrations demonstrate poorer (higher) mitigation factors. These observations support a model in which the total indoor radon concentration within a dwelling can be represented by two principal components, one susceptible to mitigation by sub-slab depressurisation, the other remaining essentially unaffected. The first component can be identified with radon emanating from the subsoil and bedrock geologies, percolating through the foundations of the dwelling as a component of the soil-gas, and potentially capable of being attenuated by sub-slab depressurisation or radon-barrier remediation technologies. The second contribution can be identified with radon emanating from materials used in the construction of the dwelling with a further contribution from the natural background level, and is essentially unaffected by ground-level remediation strategies. Modelling of a multi-component radon dependency using ground-radon attenuation factors derived from the experimental data, in conjunction with typical background and structural-radon levels, yields behaviour in good agreement with the observed dependence of mitigation factor on initial radon concentration.  相似文献   

4.
Radon daughter levels have been monitored in 12,000 Swedish dwellings during the last two years. In 1979 the Swedish Government introduced temporary limits for the radon daughter concentration in dwellings. For existing buildings this limit is 400 Bq/m3 (0.11 WL). Two different methods were used to monitor the radon daughter concentration. The majority of the houses presented in this paper were monitored using a track-etch detector; some houses were tested using a filter sampling technique while the ventilation rate was determined. Close to 15% of the investigated houses have a radon daughter concentration higher than 400 Bq/m3. The majority of these houses were one-family houses. Almost 10% of this group has a concentration above 1000 Bq/m3 (0.27 WL). The results from this study show that the two most important sources for radon in buildings are building materials and the ground.  相似文献   

5.
The measurement campaigns have been done in the rural community of Niska Banja, a spa town located in southern Serbia, to evaluate population exposure to natural radioactivity. After a screening survey in 200 houses, annual radon and thoron concentrations were measured in 34 houses, and in 2004 a detailed investigation was carried out at six houses with elevated indoor radon concentrations. The paper presents the results of these detailed measurements. The complementary techniques were applied to determine radon and thoron concentrations in indoor air, in soil gas, radon exhalation from soil, soil permeability, and indoor and outdoor gamma doses. Soil and water samples were collected and analysed in the laboratory. Indoor radon and thoron concentrations were found to be more than 1kBqm(-3) and 200Bqm(-3), respectively. Extremely high concentrations of soil-gas radon (>2000kBqm(-3)) and radon exhalation rates (1.5mBqm(-2)s(-1)) were observed. These results will be utilised to set up the methodology for a more systematic investigation.  相似文献   

6.
The scope for using Tellus Project airborne gamma-ray spectrometer and soil geochemical data to predict the probability of houses in Northern Ireland having high indoor radon concentrations is evaluated, in a pilot study in the southeast of the province, by comparing these data statistically with in-house radon measurements. There is generally good agreement between radon maps modelled from the airborne radiometric and soil geochemical data using multivariate linear regression analysis and conventional radon maps which depend solely on geological and indoor radon data. The radon maps based on the Tellus Project data identify some additional areas where the radon risk appears to be relatively high compared with the conventional radon maps. One of the ways of validating radon maps modelled on the Tellus Project data will be to carry out additional indoor measurements in these areas.  相似文献   

7.
The aim of this work was to make a comparison of indoor radon concentrations in dwellings and in soil air in the area of two geological formations in the Suwa?ki region (Poland). The mean arithmetic airborne concentration was found to be the highest (301 Bq m (-3)) in the basements of buildings in the gravel and sand areas, whereas in the boulder clay areas it reached 587 Bq m (-3). Out of 54 measurements of radon concentrations performed at the ground floor, in eight cases concentrations were found to exceed 200 Bq m (-3) - permissible radon level in new-built houses in Poland and in three cases these values were even higher than 400 Bq m (-3). The highest radon levels were noted in houses with earthen basement floors and with direct entrance from the basement to rooms or kitchens. The mean arithmetic radon concentration in the soil air in the sandy and gravel formations was 39.7 kBq m (-3) and in clay formation it was 26.5 kBq m (-3). Higher radon levels were also found in the water obtained from household wells reaching 8367 Bq m (-3) as compared with tap water (2690 Bqm (-3)). The mean indoor concentration for the whole area under study was found to be 169.4 Bq m (-3), which is higher than the mean value for Poland (49.1 Bq m (-3)) by a factor of 3.5.  相似文献   

8.
Although United Kingdom (UK) Building Regulations applicable to houses constructed since 1992 in Radon Affected Areas address the health issues arising from the presence of radon in domestic properties and specify the installation of radon-mitigation measures during construction, no legislative requirement currently exists for monitoring the effectiveness of such remediation once construction is completed and the houses are occupied. To assess the relative effectiveness of During-Construction radon reduction and Post-Construction remediation, radon concentration data from houses constructed before and after 1992 in Northamptonshire, UK, a designated Radon Affected Area, was analysed. Post-Construction remediation of 73 pre-1992 houses using conventional fan-assisted sump technology proved to be extremely effective, with radon concentrations reduced to the Action Level, or below, in all cases. Of 64 houses constructed since 1992 in a well-defined geographical area, and known to have had radon-barrier membranes installed during construction, 11% exhibited radon concentrations in excess of the Action Level. This compares with the estimated average for all houses in the same area of 17%, suggesting that, in some 60% of the houses surveyed, installation of a membrane has not resulted in reduction of mean annual radon concentrations to below the Action Level. Detailed comparison of the two data sets reveals marked differences in the degree of mitigation achieved by remediation. There is therefore an ongoing need for research to resolve definitively the issue of radon mitigation and to define truly effective anti-radon measures, readily installed in domestic properties at the time of construction. It is therefore recommended that mandatory testing be introduced for all new houses in Radon Affected Areas.  相似文献   

9.
Sweden introduced limits and gave recommendations for decreasing the indoor radon daughter concentrations in 1980. The resulting experiences are summarized. From 1979 to 1987, measurements were carried out by the local authorities in about 58 000 out of 3.9 million homes in Sweden, and 5300 homes were found to have levels exceeding the limit for existing houses, or 400 Bq/m3 of equilibrium equivalent concentration of radon (EER). This may be about 13% of the estimated 40 000 homes with levels exceeding 400 Bq/m3. Very high levels, up to 28 000 Bq/m3, have been found. According to the local authorities, in one third of the homes found with levels exceeding the limit (1921 homes) certain reconstruction and other measures have been taken in order to decrease the levels. In reality, measures have been carried out in more houses. The methods depend on the radon source. The average reductions found for respective methods are reported. The local authorities can require a check of the radon daughter concentrations in newly built houses when they suspect that the concentrations exceed the limit of 70 Bq/m3. In 11% of the measured homes built during 1981 to 1985, the levels were above the limit for newly built houses. In 1.4% of these houses, the limit for existing houses, 400 Bq/m3, had been exceeded. The strategy to decrease both the collective dose to the population and the individual dose is discussed.  相似文献   

10.
Significantly elevated radon concentrations were found in several adjacent houses in Clinton, New Jersey. The United States Environmental Protection Agency screened 56 of the houses and selected 10 for demonstration of radon-reduction techniques. Each of the 10 houses received an intensive radon diagnostic evaluation before a house-specific radon reduction plan was developed. Depressurization effects caused by temperature differentials and the operation of mechanical equipment were quantified. Before and after radon reduction plans were implemented, radon concentrations were determined by charcoal canisters and continuous radon monitors. A variety of sealing and subslab depressurization techniques were applied to the 10 houses. Radon concentrations were reduced by over 95% in all 10 houses. The cost of applying radon reduction techniques ranged from $1500 to $8500 per house. House construction characteristics were described which contributed to the high cost of radon reduction. In summary, the 10-house radon reduction demonstration in Clinton, New Jersey was successful in showing homeowners with similar house types some effective ways of reducing radon concentrations.  相似文献   

11.
Concentrations of airborne radon ranging from 0.05 to 135 pCi/L were found in houses in Maine. Tracketch cups were placed in five positions for 100 houses to determine integrated average radon concentrations over the period October 1980–May 1981. To investigate the association between elevated radon concentrations in well water and the indoor airborne radon concentrations, the radon in the water supplies of these houses was measured by liquid scintillation. Monitors of airborne radon, recording in intervals of 10 min for periods of 5–7 days, were used for dynamic studies in 18 houses, determining the component of airborne radon associated with major water uses, such as showers, laundry, and dishwashing, which liberate radon in bursts. House residents kept logs noting the time of major water uses. For some of the houses, ventilation rates ranging from 0.3 to 2 air changes per hour were determined by analysis of the dynamic data. The component of airborne radon associated with water sources was found to vary inversely with ventilation rate and directly with waterborne radon concentration, with 0.8 ± 0.2 pCi Rn/L air per nCi Rn/L water at a ventilation rate of 1.0 air change per hour. The data are pertinent to a study which has revealed significant correlations between county averages, from the National Cancer Institute, or age-adjusted cancer mortality rates in Maine and average values of radon concentrations in water for the counties.  相似文献   

12.
Results of indoor gamma radiation and radon measurements in 95 wooden dwellings located in a Norwegian thorium-rich carbonatite area using thermoluminescent dosemeters and CR-39 alpha track detectors, respectively, are reported together with a thorough analysis of the indoor data with regard to geological factors. Slightly enhanced radium levels and thorium concentrations of several thousands Bq kg(-1) in the carbonatites were found to cause elevated indoor radon-222 levels and the highest indoor gamma dose rates ever reported from wooden houses in Norway. An arithmetic mean indoor gamma dose rate of 200 nGy h(-1) and a maximum of 620 nGy h(-1) were obtained for the group of dwellings located directly on the most thorium-rich bedrock.  相似文献   

13.
Monitoring of radon, thoron and their daughter products was carried out in houses of Kumaun Himalaya, India using LR-115 plastic track detectors. The measurements were made in residential houses from June 1999 to May 2000 at a height of 2.5 m from ground level using a twin chamber radon dosimeter. The twin chamber radon dosimeter can record the values of radon, thoron and their decay products separately. Maximum and minimum indoor radon and thoron concentrations were evaluated and activity concentrations of radon and thoron daughters were estimated. The resulting dose rates due to radon, thoron and their decay products varied from 0.04 to 1.89 microSv/h. A detailed analysis of the distribution of radon, thoron and their decay products inside the house is also reported. The observed dose rates inside the houses of Kumaun Himalaya were found to be lower than the ICRP recommended value of 200 Bq/m3 and thus are within safe limits.  相似文献   

14.
In the beginning of 1990s within the framework of a national radon survey of more than 1500 points, radon measurements were performed in more than 100 houses located in Galicia region, in the Northwest area of Spain. The houses were randomly selected only bearing in mind general geological aspects of the region. Subsequently, a nationwide project called MARNA dealt with external gamma radiation measurements in order to draw a Spanish natural radiation map. The comparison in Galicia between these estimations and the indoor radon levels previously obtained showed good agreement. With the purpose of getting a confirmation of this relationship and also of creating a radon map of the zone, a new set of measurements were carried out in 2005. A total of 300 external gamma radiation measurements were carried out as well as 300 measurements of (226)Ra, (232)Th and (40)K content in soil. Concerning radon, 300 1-m-depth radon measurements in soil were performed, and indoor radon concentration was determined in a total of 600 dwellings. Radon content in soil gave more accurate indoor radon predictions than external gamma radiation or (226)Ra concentration in soil.  相似文献   

15.
A radon survey has been carried out around the town of Niska Banja (Serbia) in a region partly located over travertine formations, showing an enhanced level of natural radioactivity. Outdoor and indoor radon concentrations were measured seasonally over the whole year, using CR-39 diffusion type radon detectors. Outdoor measurements were performed at 56 points distributed over both travertine and alluvium sediment formations. Indoor radon concentrations were measured in 102 living rooms and bedrooms of 65 family houses. In about 50% of all measurement sites, radon concentration was measured over each season separately, making it possible to estimate seasonal variations, which were then used to correct values measured over different periods, and to estimate annual values. The average annual indoor radon concentration was estimated at over 1500 Bq/m3 and at about 650 Bq/m3 in parts of Niska Banja located over travertine and alluvium sediment formations, respectively, with maximum values exceeding 6000 Bq/m3. The average value of outdoor annual radon concentration was 57 Bq/m3, with a maximum value of 168 Bq/m3. The high values of indoor and outdoor radon concentrations found at Niska Banja make this region a high natural background radiation area. Statistical analysis of our data confirms that the level of indoor radon concentration depends primarily on the underlying soil and building characteristics.  相似文献   

16.
Measurements of indoor radon concentrations were performed in 28 low-rise houses and 30 apartments in Patras area from December 1996 to November 1997, using nuclear track detectors. The investigation was focused on the effects of season and floor number, as well as on the existence of a basement in low-rise houses on indoor radon levels. It was found that the differences in mean radon concentrations between adjacent seasons, in a number of 61 selected sampling sites distributed in 28 houses, were statistically significant. As expected, a maximum was found in winter and a minimum in summer. The differences in mean radon concentration on different floors of the same houses were also statistically significant and followed a linear decrease from underground to 2nd floor. In addition, indoor radon concentrations in the ground floor were found to be influenced by the existence or not of a basement. The average annual radon concentration was found to be 41 Bq m(-3) for the houses, 28 Bq m(-3) for the apartments and 38 Bq m(-3) for all the dwellings. These values lead to an average effective dose equivalent of 1.1, 0.7 and 0.9 mSv y(-1), respectively. Residents living on the underground in low-rise houses, during winter, where the average effective dose equivalent is 2.1 mSv y(-1), attain the higher risk.  相似文献   

17.
From 2003-2004, using solid state nuclear detectors, a survey of the air radon level in 234 underground buildings in 23 cities of China was carried out during spring as well as summer and winter. The annual radon concentrations in these underground buildings range from 14.9 to 2482 Bq m(-3), with an overall mean value of 247 Bqm(-3). When radon concentrations are averaged according to cities, Fuzhou and Baotou have the relatively higher radon levels, which are 714 and 705 Bqm(-3), respectively. Guangzhou and Shanghai have the relatively lower radon levels with 71.1 and 72.6 Bqm(-3). The annual effective dose by exposure to radon received by people working in these cities is concluded to be 1.6 mSv. The geological formation, coating level, decorating materials and ventilation situation all affect the radon concentration in underground buildings. The radon level in underground buildings has the lowest value in winter and the highest value in summer.  相似文献   

18.
ANOVA is used to show that approximately 25% of the total variation of indoor radon concentrations in England and Wales can be explained by the mapped bedrock and superficial geology. The proportion of the total variation explained by geology is higher (up to 37%) in areas where there is strong contrast between the radon potential of sedimentary geological units and lower (14%) where the influence of confounding geological controls, such as uranium mineralisation, cut across mapped geological boundaries. When indoor radon measurements are grouped by geology and 1-km squares of the national grid, the cumulative percentage of the variation between and within mapped geological units is shown to be 34-40%. The proportion of the variation that can be attributed to mapped geological units increases with the level of detail of the digital geological data. This study confirms the importance of radon maps that show the variation of indoor radon concentrations both between and within mapped geological boundaries.  相似文献   

19.
This paper reports the results of indoor radon measurements carried out in the Lombard plain. The aim of this study, which is based on the geological context, was to identify radon high-risk areas. The underlying geology has been established by means of the available stratigraphies giving a schematic representation of the sites in which either occurrence of gravel or silt and clay predominate with depths ranging from 0 to 50 m. Radon measurements were performed in a sample of 411 one-family houses in seven villages located in the southern area of Bergamo and Brescia. The findings indicate that when the substrate is dominated by clay, radon concentration for dwellings on the ground floor are low, whereas a strong predominance of underlying gravel mixed up in sand gives in winter months high radon flux from underground.  相似文献   

20.
The approach proposed in this study provides insight into the influence of the basement geochemistry on the spatial distribution of radon (222Rn) levels both at the soil/atmosphere interface and in the atmosphere. We combine different types of in situ radon measurements and a geochemical classification of the lithologies, based on 1/50,000 geological maps, and on their trace element (U, Th) contents. The advantages of this approach are validated by a survey of a stable basement area of Hercynian age, located in South Brittany (western France) and characterized by metamorphic rocks and granitoids displaying a wide range of uranium contents. The radon source-term of the lithologies, their uranium content, is most likely to be the primary parameter which controls the radon concentrations in the outdoor environment. Indeed, the highest radon levels (> or = 100 Bq m-3 in the atmosphere, > or = 100 mBq m-2 s-1 at the surface of the soil) are mostly observed on lithologies whose mean uranium content can exceed 8 ppm and which correspond to peraluminous leucogranites or metagranitoids derived from uraniferous granitoids.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号