首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   15篇
  免费   4篇
  国内免费   8篇
环保管理   1篇
综合类   13篇
基础理论   3篇
污染及防治   3篇
评价与监测   7篇
  2022年   2篇
  2019年   1篇
  2017年   1篇
  2014年   2篇
  2013年   3篇
  2011年   1篇
  2010年   2篇
  2009年   1篇
  2008年   1篇
  2007年   3篇
  2006年   2篇
  2003年   3篇
  2002年   1篇
  1999年   1篇
  1998年   1篇
  1996年   2篇
排序方式: 共有27条查询结果,搜索用时 218 毫秒
1.
Bankside groundwater is widely used as drinking water resource and, therefore, contamination has to be avoided. In the European Union groundwater protection is explicit subject to Water Framework Directive. While groundwater pollution may originate from different sources, this study investigated on impacts via flood events.Groundwater was sampled with increasing distance to the river Rhine near Karlsruhe, Germany. Samples were HPLC-MS-MS analyzed for the river contaminant carbamazepine to indicate river water infiltration, giving permanent presence in 250 m distance to the river (14-47 μg L−1). Following a flood event, concentrations of about 16-20 μg L−1 could also be detected in a distance of 750 m to the river. Furthermore, estrogenic activity as determined with the Yeast Estrogen Screen assay was determined to increase up to a 17β-ethinylestradiol equivalent concentration (E-EQ) = 2.9 ng L−1 near the river, while activity was initially measured following the flood with up to E-EQ = 2.6 ng L−1 in 750 m distance. Detections were delayed with increasing distance to the river indicating river water expansion into the aquifer.Flood suspended matter and floodplain soil were fractionated and analyzed for estrogenic activity in parallel giving up to 1.4 ng g−1 and up to 0.7 ng g−1, respectively. Target analysis focusing on known estrogenic active substances only explained <1% of measured activities.Nevertheless, river water infiltration was shown deep into bankside groundwater, thus, impacting groundwater quality. Therefore, flood events have to be in the focus when aiming for groundwater and drinking water protection as well as for implementation of Water Framework Directive.  相似文献   
2.
Road ambient air pollution status along Dhanbad – Jharia road isstudied and presented in this article. The selection of this areais made considering the importance of the road in Dhanbad district and the nature of activities taking place along the road, which reflect that the portion of road upto Dhansar can be considered as having commercial areas on both sides and that from Dhansar to Jharia as having industrial areas on both sides.For the assessment of the ambient air quality along the road monitoring is done at the following five locations: Indian Schoolof Mines (ISM), main gate; Bankmore; Dhansar police check post; Dhansar opencast project agent office and a residential house beside the Rajapur opencast project. The location of ISM, maingate is specially chosen as this represents a commercial shoppingcomplexes and the situation can be compared with that at Bankmore. Monitoring of ambient air quality is done following thestandard procedure prescribed in IS: 5182. In addition the concentration of lead, zinc, copper, iron, manganese, cadmium metals in SPM is also monitored. The ambient air quality is monitored in the months of September and November 1999, respectively, to represent monsoon and winter seasons. The SPM concentration observed at all the five locations in the winterseason is more than the permissible limits for commercial andindustrial areas. However, in the monsoon season, the SPM concentration is higher than the permissible limit at the twocommercial locations, i.e., ISM gate and Bankmore, while it isless than the prescribed limit for industrial areas at the remaining three locations. At the ISM gate and Bankmore the SPM generation is mainly by vehicular traffic while at other three locations it was in addition due to mining and other activities.  相似文献   
3.
An air quality sampling program was designed and implemented to collect the baseline concentrations of respirable suspended particulates (RSP = PM10), non-respirable suspended particulates (NRSP) and fine suspended particulates (FSP = PM2.5). Over a three-week period, a 24-h average concentrations were calculated from the samples collected at an industrial site in Southern Delhi and compared to datasets collected in Satna by Envirotech Limited, Okhla, Delhi in order to establish the characteristic difference in emission patterns. PM2.5, PM10, and total suspended particulates (TSP) concentrations at Satna were 20.5 ± 6.0, 102.1 ± 41.1, and 387.6 ± 222.4 μg m−3 and at Delhi were 126.7 ± 28.6, 268.6 ± 39.1, and 687.7 ± 117.4 μg m−3. Values at Delhi were well above the standard limit for 24-h PM2.5 United States National Ambient Air Quality Standards (USNAAQS; 65 μg m−3), while values at Satna were under the standard limit. Results were compared with various worldwide studies. These comparisons suggest an immediate need for the promulgation of new PM2.5 standards. The position of PM10 in Delhi is drastic and needs an immediate attention. PM10 levels at Delhi were also well above the standard limit for 24-h PM10 National Ambient Air Quality Standards (NAAQS; 150 μg m−3), while levels at Satna remained under the standard limit. PM2.5/PM10 values were also calculated to determine PM2.5 contribution. At Satna, PM2.5 contribution to PM10 was only 20% compared to 47% in Delhi. TSP values at Delhi were well above, while TSP values at Satna were under, the standard limit for 24-h TSP NAAQS (500 μg m−3). At Satna, the PM10 contribution to TSP was only 26% compared to 39% in Delhi. The correlation between PM10, PM2.5, and TSP were also calculated in order to gain an insight to their sources. Both in Satna and in Delhi, none of the sources was dominant a varied pattern of emissions was obtained, showing the presence of heterogeneous emission density and that nonrespirable suspended particulate (NRSP) formed the greatest part of the particulate load.  相似文献   
4.
A study on concentrations of ambient particulates viz. total suspended particulate matters (TSP), respirable suspended particulate matter (RSPM) and polycyclic aromatic hydrocarbons (PAH) were carried out at six sites around the Asia’s largest, 12 MMTPA, petroleum refinery in west coast of India. PAH concentrations are correlated with each other in these sites, suggesting that they have related sources and sinks. The present article discusses the monitoring aspects such as sample collection, pretreatment and analytical methods and compares the monitored levels for assessing the source receptor distribution pattern. The main sources of RSPM and PAHs in urban air are automobile exhaust (CPCB, Polycyclic aromatic hydrocarbons (PAHs) in air and their effects on human health. “”, 2003; Manuel et al., Environmental Science and Technology, 13: 227–231, 2004) and industrial emissions like petroleum refinery (Vo-Dinh, Chemical analysis of polycyclic aromatic hydrocarbons, Wiley: New York, 1989; Wagrowaski and Hites, Environmental Science and Technology, 31: 279–282, 1997). Polycyclic aromatic hydrocarbons (PAH) are ubiquitous constituents of urban airborne particulate mostly generated by anthropogenic activities (Li et al., Environmental Science and Technology, 37:1958–2965, 2003; Thorsen et al., Environmental Science and Technology, 38: 2029–2037, 2004; Ohura et al., Environmental Science and Technology, 32: 450–455, 2004) and some of them are of major health concern mainly due to their well-known carcinogenic and mutagenic properties (Soclo et al., Marine Pollution Bulletin, 40: 387–396, 2000; Chen et al., Environment International, 28: 659–668, 2003; Larsen and Baker, Environmental Science and Technology, 32: 450–455, 2003). Limited information is available on PAHs contributions from refineries to ambient air. Hence this study would not only create a database but also provide necessary inputs towards dose-response relationship for fixing standards. Also, since it acts as precursor to green house gas, the data would be useful for climate change assessments. The objective of this article is to find out the concentration of PAHs in particulate matter around petroleum refinery and compare with their concentrations in major Indian urban centers.  相似文献   
5.
主要结合多年民航系统设备设施的雷电防护建设实践,在符合国家和民航局相关规定、技术规范的前提下,理论结合实际说明民航通信、导航、监视设施雷电防护的特点。  相似文献   
6.
SPM对铅溶液的处理效果研究   总被引:1,自引:0,他引:1  
含铅废水仅经过化学沉淀法处理后的出水不够稳定,因此需要后期处理来保证出水稳定并符合国家综合污水排放标准。新型特种粉体材料Special Powder Materia(lSPM)为我国自主研发的新型粉体材料,对微污染的水源有良好的处理效果,去除重金属的主要机理为电化学反应、吸附等。文章目的在于研究SPM去除铅效果的影响因素;研究SPM处理含铅溶液的浓度范围,考察将SPM的应用范围扩展至含铅废水后期处理的可行性。影响SPM处理效果的因素有进水流向、流量、填料高度、停留时间、含铅溶液浓度等,为了定量研究各个因素对SPM处理效果的贡献大小,文章采用配水试验,考察不同条件下SPM对铅的去除效率并进行正交分析。结果表明,进水方向采用逆流方向优于顺流方向,影响SPM处理铅溶液效率的主要因素为进水流量和进水浓度,SPM对较高浓度含铅溶液有明显的除铅效果,有望用于废水后期处理。进水方向为逆流,流量为12L/h,进水浓度为2mg/L时,出水浓度能长时间保证在1mg/L以下,符合国家综合污水排放标准。  相似文献   
7.
涕灭威在水体悬浮颗粒物上的吸附行为   总被引:1,自引:0,他引:1  
通过静态吸附实验,探讨了氨基甲酸酯类农药涕灭威在水体悬浮颗粒物上的吸附规律.实验表明,25±1℃条件下,涕灭威在低浓度(0.2~1.5mg/L)时,在颗粒物上的吸附符合Langmuir等温吸附;在2.0~15mg/L用Freundlich吸附等温线描述更合理;在20~2000mg/L,涕灭威的吸附既可以用线性等温方程式也可以用Fre-undlich等温方程式来描述.并研究了阴离子表面活性剂SDBS和非离子表面活性剂TWEEN60存在下涕灭威的吸附等温线,以及悬浮颗粒物浓度、腐殖酸、pH、盐度及微生物对涕灭威在颗粒物上吸附行为的影响.  相似文献   
8.
The study focuses on assessing the status of respiratory morbidity in Delhi over a four years period from 2000–2003. An attempt was made to investigate the role of important pollutants (SO2, NO2, SPM and RSPM) and various meteorological factors (temperature minimum & maximum, relative humidity at 0830 and 1730 hrs. and wind speed) in being responsible for respiratory admissions on account of COPD, asthma and emphysema. The study showed that winter months had greater exposure risk as pollutants often get trapped in the lower layers of atmosphere resulting in high concentrations. Statistical analysis revealed that two pollutants have significant positive correlation with the number of COPD cases viz., SPM (r = 0.474; p < 0.01) and RSPM (r = 0.353; p < 0.05), while a meteorological factor temperature (minimum) has a significant negative correlation (r = −0.318; p < 0.05) with COPD. Stepwise multiple regression analysis was performed for COPD as dependent variable and R2 value of 0.33 was obtained indicating that SPM and RH(1730) were able to explain 33 percent variability in COPD. The partial correlation of SPM and RH(1730) on COPD was higher than any other combination and therefore they can be regarded as important contributing variables on COPD.  相似文献   
9.
日本东京湾地区冬季飘尘污染研究   总被引:3,自引:1,他引:3  
对东京湾地区冬季高浓度飘尘污染进行了分析,研究结果表明,日本某些特定地区也存在着与中国严重污染城市相当的飘尘污染;分析指出高浓度的飘尘污染主要来自于人为污染,其中废弃物焚烧和汽车排气的贡献占重要地位,这与中国大气煤烟型污染截然不同。  相似文献   
10.
不同季节辽河口营养盐的河口混合行为   总被引:5,自引:3,他引:2  
分别于2010年4、7、11月对大辽河口水域进行了3个航次的调查,测定了水体中各形态营养盐的浓度.结果表明,各形态氮、磷浓度的季节变化明显.PO3-4-P、DOP、DTP和TP平均含量的季节分布相似:均为4月最高,11月次之,7月最低;而PP平均含量由大到小依次为11、4、7月.NO-3-N、NO-2-N的含量为7月最高,4月最低;NH+4-N、DON、PN的含量为4月最高,7月最低.4月NH+4-N为TN的主要存在形态,而7、11月NO-3-N为N的主要存在形态.NO-3-N、DIN、TN在3个季节的河口混合过程中均呈保守性;而NO-2-N、NH+4-N、DON在4、11月也是保守性的,但在7月为非保守性,在河口内部存在添加源.3个季节大辽河口水域的硅酸盐均呈现保守行为,11月平均含量最高,4月最低.  相似文献   