首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   33篇
  免费   0篇
  国内免费   2篇
安全科学   1篇
废物处理   2篇
环保管理   1篇
综合类   5篇
基础理论   6篇
污染及防治   19篇
评价与监测   1篇
  2023年   6篇
  2022年   9篇
  2021年   7篇
  2019年   2篇
  2018年   3篇
  2017年   2篇
  2016年   1篇
  2015年   1篇
  2013年   3篇
  2011年   1篇
排序方式: 共有35条查询结果,搜索用时 531 毫秒
21.
Objectives: The aim of this study was to estimate the main driving-impairing medications used by drivers in Jordan, the reported frequency of medication side effects, the frequency of motor vehicle crashes (MVCs) while using driving-impairing medicines, as well as factors associated with MVCs.

Methods: A cross-sectional study involving 1,049 individuals (age 18–75 years) who are actively driving vehicles and taking at least one medication known to affect driving (anxiolytics, antidepressants, hypnotics, antiepileptics, opioids, sedating antihistamines, hypoglycemic agents, antihypertensives, central nervous system [CNS] stimulants, and herbals with CNS-related effects) was conducted in Amman, Jordan, over a period of 8 months (September 2013–May 2014) using a structured validated questionnaire.

Results: Sixty-three percent of participants noticed a link between a medicine taken and feeling sleepy and 57% stated that they experience at least one adverse effect other than sleepiness from their medication. About 22% of the participants reported having a MVC while on medication. Multiple logistic regression analysis showed that among the participants who reported having a crash while taking a driving-impairing medication, the odds ratios were significantly higher for the use of inhalant substance (odds ratio [OR] = 2.787, P = .014), having chronic conditions (OR = 1.869, P = .001), and use of antiepileptic medications (OR = 2.348, P = .008) and significantly lower for the use of antihypertensives (OR = 0.533, P = .008).

Conclusion: The study results show high prevalence of adverse effects of medications with potential for driving impairment, including involvement in MVCs. Our findings highlight the types of patient-related and medication-related factors associated with MVCs in Jordan, such as inhalant use, presence of chronic conditions, and use of antiepileptics.  相似文献   

22.
In our previous work, the prepared high-impact polystyrene (HIPS) membranes, synthesized using four concentrations (20, 25, 30, and 35 wt%) of waste HIPS, were proved to be promising for water purification by microfiltration process (MF). However, the fabricated membranes' mechanical properties and microfiltration process parameters were not investigated. Consequently, in this study, various parameters affecting the previously fabricated membranes' performance in the filtration process, such as membrane mechanical properties, feeding pressure, fouling behavior, and polymer concentration, were thoroughly investigated. With increasing polystyrene concentrations, the ultimate tensile strength of the fabricated membranes increased. When the concentration was increased from 20 to 25 wt percent, the elongation at break rose, but as the concentration was increased further, the membrane became brittle. Permeate flux and rejection both declined as polymer content was raised. Accordingly, the highest flux and humic acid (HA) rejection were shown by 20 wt% (14.18 L/m2h (LMH) and 98.95%, respectively). The antifouling properties declined when the polymer concentration was raised, and 20 wt% had the lowest total fouling resistance. Furthermore, the permeate flux was reduced while increasing the HA initial concentration.  相似文献   
23.
Stable colloidal silver nanoparticles (AgNPs) were synthesized using Caulerpa serrulata (green marine algae) aqueous extract as an efficient reducing and stabilizing agent. This method is considered to be a sustainable alternate to the more complicated chemical procedures. To achieve the optimization synthesis of AgNPs, several effects such as extract concentration, contact time, pH values, and temperature were examined. The synthesized AgNPs were characterized by UV–Vis spectroscopy, FT-IR, XRD, and HR-TEM. The synthesized AgNPs showed an intense surface plasmon resonance band at 412 nm at the optimal conditions (20% (v/v) extract and 95 °C). TEM reveal that higher extract concentration and higher temperature leading to the formation of spherical AgNPs with an average particle size of 10 ± 2 nm. The synthesized AgNPs showed excellent catalytic reduction activity of Congo red (CR) dye from aqueous solutions. The degradation percentage of CR with AgNPs accelerated by increasing either NaBH4 concentration or catalytic dosage. The AgNPs synthesized at higher temperature (e.g., 10Ag-95) exhibited the highest catalytic activity. The reaction kinetics was found to be pseudo first order with respect to the dye concentration. Moreover, the AgNPs displayed antibacterial activity at lower concentration against Staphylococcus aureus, Pseudomonas aeruginosa, Shigella sp., Salmonella typhi, and Escherichia coli and may be a good alternative therapeutic approach. The outcomes of the current study confirmed that the synthesized AgNPs had an awesome guarantee for application in catalysis and wastewater treatment.  相似文献   
24.
Environmental Science and Pollution Research - This study aims to explore the chemopreventive mechanisms of hydroethanolic extracts from avocado (Persea Americana) in diethylnitrosamine...  相似文献   
25.
Environmental Science and Pollution Research - A novel visible-light-sensitive ZnVFeO4 photocatalyst has been fabricated by the precipitation method at different pH values for the enhanced...  相似文献   
26.
An indirect competitive enzyme-linked immunosorbent assay (ELISA) has been developed and optimized for atrazine determination in soil at different depths (0-10, 10-20, and 20-30 cm) before and after 48 h of application, corn shoot and cow milk samples collected from Dina farm, Egypt. This assay was based on a specific polyclonal antibodies (PAb) raised by immunizing New Zealand rabbits with an immunogen prepared by coupling 3-{4-(ethylamino)-6-(isopropylamino)-1,3,5-triazine-2-yl} thiopropanoic acid to bovine serum albumin (BSA) via N-hydroxysuccinimide (NHS) active ester method. The sensitivity (estimated as IC?? value) was 17.5 μg mL?1 with a detection limit of 0.1 ng mL?1. The maximum atrazine concentration was found in soil especially in the deepest layer (325 and 890 μg kg?1 before and after application, respectively). Atrazine concentration in corn shoot was 333.28, μg kg?1 dry plant, while there was no detectable amount in milk. All samples screened by ELISA were validated by gas chromatography mass spectrometer procedure (GC/MS). Good correlation was achieved between the two methods (r = 0.997 for soil and 0.9814 for plant). This study demonstrates the utility and convenience of the simple, practical and cost-effective ELISA method in the laboratory for analysis of environmental samples. The method is ideal for the rapid screening of large numbers of samples in laboratories where access to GC/MS facilities, is limited or lacking.  相似文献   
27.
Environmental Science and Pollution Research - Since the industrial revolution in the 1800s, plastic pollution is becoming a global reality. This study aims to assess knowledge and attitude about...  相似文献   
28.
29.
An indirect competitive enzyme-linked immunosorbent assay (ELISA) has been developed and optimized for atrazine determination in soil at different depths (0–10, 10–20, and 20–30 cm) before and after 48 h of application, corn shoot and cow milk samples collected from Dina farm, Egypt. This assay was based on a specific polyclonal antibodies (PAb) raised by immunizing New Zealand rabbits with an immunogen prepared by coupling 3-{4-(ethylamino)-6-(isopropylamino)-1,3,5-triazine-2-yl} thiopropanoic acid to bovine serum albumin (BSA) via N-hydroxysuccinimide (NHS) active ester method. The sensitivity (estimated as IC50value) was 17.5 μg mL?1 with a detection limit of 0.1 ng mL?1. The maximum atrazine concentration was found in soil especially in the deepest layer (325 and 890 μg kg?1 before and after application, respectively). Atrazine concentration in corn shoot was 333.28, μg kg?1 dry plant, while there was no detectable amount in milk. All samples screened by ELISA were validated by gas chromatography mass spectrometer procedure (GC/MS). Good correlation was achieved between the two methods (r = 0.997 for soil and 0.9814 for plant). This study demonstrates the utility and convenience of the simple, practical and cost–effective ELISA method in the laboratory for analysis of environmental samples. The method is ideal for the rapid screening of large numbers of samples in laboratories where access to GC/MS facilities, is limited or lacking.  相似文献   
30.
Seaweeds belonging to 14 different genera of Chlorophyta, Phaeophyta and Rhodophyta were analyzed to determine the levels of heavy metals in two areas of the Egyptian Red Sea coast. Among the trace metals analyzed, Mn and Zn showed the highest mass concentrations in the surface seawaters of the two studied areas. However, algae obtained from Suez area had the highest concentrations of the investigated heavy metals than those collected from Mars Alam area. Nevertheless, a high variability of the metal levels occurs among the studied algae and also between the investigated areas. Moreover, Zn was the most abundant metal in the seaweeds of the Suez area, while Pb was predominant in Mars Alam area in red and brown algae. L. farinosa had the highest average concentration factor of Zn in Suez (29161 fold), while it was 20091 fold in E. intestinalis at Mars Alam. The highest value of metal pollution index (MPI) was recoded in L. farinosa (22.0) at Suez. It represents 4.6 fold of that value recorded in L. farinosa at Mars Alam. Among green, brown and red algae in Suez, the highest values of MPI were recorded in Cladophora (mixed sub-species) and H. comuto (18.2 and 18.3), P. pavonia (16.2) and L. farinosa (22.1), respectively; while at Mars Alam, they were recorded in Cladophora (mixed sub-species) (6.6), P. pavonia (3.4) and L. farinosa (4.8), respectively.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号