全文获取类型
收费全文 | 161篇 |
免费 | 1篇 |
国内免费 | 8篇 |
专业分类
安全科学 | 12篇 |
废物处理 | 19篇 |
环保管理 | 8篇 |
综合类 | 18篇 |
基础理论 | 21篇 |
污染及防治 | 72篇 |
评价与监测 | 18篇 |
社会与环境 | 2篇 |
出版年
2022年 | 5篇 |
2021年 | 6篇 |
2019年 | 4篇 |
2018年 | 6篇 |
2017年 | 10篇 |
2016年 | 5篇 |
2015年 | 1篇 |
2014年 | 9篇 |
2013年 | 17篇 |
2012年 | 14篇 |
2011年 | 16篇 |
2010年 | 10篇 |
2009年 | 10篇 |
2008年 | 9篇 |
2007年 | 10篇 |
2006年 | 6篇 |
2005年 | 2篇 |
2004年 | 7篇 |
2003年 | 5篇 |
2002年 | 6篇 |
2001年 | 7篇 |
1999年 | 1篇 |
1998年 | 1篇 |
1995年 | 1篇 |
1994年 | 1篇 |
1991年 | 1篇 |
排序方式: 共有170条查询结果,搜索用时 218 毫秒
151.
Oh JE Chang YS Ikonomou MG 《Journal of the Air & Waste Management Association (1995)》2002,52(1):69-75
Polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) were monitored in stack gas and fly ash of various Korean incinerators and in air samples collected near the facilities. Concentrations of PCDD/Fs in emissions were investigated, and characteristic PCDD/F homologue patterns were classified using statistical analyses. The PCDD/F emission levels in stack gas and fly ash samples from small incinerators (SIs) were higher than those from municipal solid waste incinerators (MSWIs). The PCDD/F concentrations ranged between 0.38 and 1.16 pg I-TEQ/m3 (21.2-75.2 pg/m3) in ambient air samples. The lower-chlorinated furans were the dominant components in most of the stack gas and fly ash samples from SIs, although this was not the case for fly ash from MSWIs. This homologue pattern is consistent with other studies reporting a high fraction of lower-chlorinated furans in most environmental samples affected by incinerator emissions, and it can be used as an indicator to assess the impact of such facilities on the surrounding environment. 相似文献
152.
The aim of this study was to determine the unit load of NPS (non-point source) pollutants including organic variables such as BOD (biochemical oxygen demand),COD (chemical oxygen demand) and DOC (dissolved organic carbon),nitrogen and phosphorus constituents,and suspended solids (SS) and their event mean concentration (EMC) of runoff flows from a water-shed of mixed forest land use by intensive field experiments.Field monitoring for continuous measurements of rainfall,flow,and water quality was conducted over 12 storm events during 2008–2009 using automated and manual sampling methods.The EMCs of individual runoff event were estimated for each water quality constituent based on the flow rate and concentration data of runoff discharge.The average EMCs of BOD,COD,DOC,SS,TN (total nitrogen),NH 4+ -N,NO 3- -N,TP (total phosphorus),PO 43- -P from the mixed forest land were 1.794,3.498,1.462,10.269,0.862,0.044,0.634,0.034,and 0.005 mg/L,respectively.The annual unit loads of BOD,COD,DOC,SS,TN,NH 4+ -N,NO 3- -N,TP and PO 43--P were estimated as 66.9,133.2,55.5,429.8,36.5,1.6,26.9,1.3 and 0.1 kg/(ha·yr),respectively.In addition,affecting parameters on the EMCs were investigated by statistic analysis of the field data.As a result,significant correlations with precipitation,rainfall intensity,and total runoff flows were found in most constituents. 相似文献
153.
Mikyung Park Jinkwan Oh Kihong Park 《Frontiers of Environmental Science & Engineering in China》2011,5(3):313-319
A continuous flow streamwise thermal gradient cloud condensation nuclei (CCN) counter with an aerosol focusing and a laser-charge-coupled
device (CCD) camera detector system was developed here. The counting performance of the laser-CCD camera detector system was
evaluated by comparing its measured number concentrations with those measured with a condensation particle counter (CPC) using
polystyrene latex (PSL) and NaCl particles of varying sizes. The CCD camera parameters (e.g. brightness, gain, gamma, and
exposure time) were optimized to detect moving particles in the sensing volume and to provide the best image to count them.
The CCN counter worked well in the particle number concentration range of 0.6–8000 #·cm−3 and the minimum detectable size was found to be 0.5 μm. The supersaturation in the CCN counter with varying temperature difference
was determined by using size-selected sodium chloride particles based on K?hler equation. The developed CCN counter was applied
to investigate CCN activity of atmospheric ultrafine particles at 0.5% supersaturation. Data showed that CCN activity increased
with increasing particle size and that the higher CCN activation for ultrafine particles occurred in the afternoon, suggesting
the significant existence of hygroscopic or soluble species in photochemically-produced ultrafine particles. 相似文献
154.
Seok-jin Hong Yoon-sil Choi Kyoung-ryun Kim Joon-gu Kang Gil-jong Oh Tak Hur 《Resources, Conservation and Recycling》2011,55(12):1206-1213
The flows of paper are analyzed throughout the papermaking processes, with the year 2007 and Korea defined as the system boundaries. In practice, the statistical data on the production, import and export of paper or pulp can be collected with relative ease from the government and industrial associations. However, the input data regarding the volumes of pulp and wastepaper used in different paper products, such as newsprint, printing papers, sanitary and household papers, specialty papers, and corrugating board base, are difficult to obtain because such information is generally kept confidential in the course of corporate operations.The production processes of paper products in Korea are modeled using information on raw materials, their compositions and production yields of products in order to identify and quantify the amounts of pulp and wastepaper used in each paper product. The material flows of paper are then analyzed based on the calculation model derived from the correlation of input and output flows between the individual processes throughout the entire paper lifecycle. Accuracy analysis using both mean absolute error (MAE) and mean absolute percent error (MAPE) is conducted to verify the amounts of pulp and wastepaper calculated from the proposed model against the volumes of domestically consumed pulp and wastepaper provided in the national statistics. Although the calculated values for the past (i.e., the 1980s and 1990s) differ to some degree from the statistical values, the data for the 2000s have a relatively higher level of accuracy, with the MAPE of the total pulp and recycling volume at 5.39% and 5.30%, respectively, thus validating the adequacy of the proposed modeling method. The proposed calculation model can be effectively used in the material flow analysis (MFA) of paper to reduce the burden of data collection and obtain relatively accurate results. 相似文献
155.
The concentrations and removal efficiencies of various kinds of micropollutants were investigated and the relationships between the input sources of industrial wastewater and occurrence patterns of each micropollutant were identified at nine on-site industrial wastewater treatment plants (WWTPs). The distribution pattern of each compound varied according to the WWTP type and several micropollutants were significantly related with specific industries: chlorinated phenols (ClPhs) with paper and metal industries, polycyclic aromatic hydrocarbons (PAHs) with petrogenic- and pyrogenic-related industries, polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) with the paper industry, and chlorinated benzenes (ClBzs) with dye-related industries. The activated sludge (AS) process was very efficient in the removal of ClPhs and PAHs, and the filtration process in the removal of PCDD/Fs and 1,4-dioxane. Generally, the removal efficiencies of each micropollutant varied according to the WWTP type. 相似文献
156.
Yun He Jianyong Liu Chengyuan Shen Xuewen Yi Xiaowei Li Xin Huang Kokyo Oh Guoji Ding 《Frontiers of Environmental Science & Engineering》2022,16(4):43
157.
Joon Seok Kong Oh Hyun Kim Hyun Youk Hee Young Lee Chan Young Kang Sil Sung 《Traffic injury prevention》2018,19(8):S151-S153
AbstractObjective: The purpose of this study is to investigate the injury patterns of noncatastrophic accidents by individual age groups.Methods: Data were collected from the Korean In-Depth Accident Study database based on actual accident investigation. The noncatastrophic criteria were classified according to U.S. experts from the Centers for Disease Control and Prevention’s recommendations for field triage guidelines of high-risk automobile crash criteria by vehicle intrusions more than 12 in. on occupant sites (including the roof) and more than 18 in. on any site. The Abbreviated Injury Scale (AIS) was used to determine injury patterns for each body region. Severely injured patients were classified as Maximum Abbreviated Injury Scale (MAIS) 3 or higher.Results: In this study, the most significant injury regions were the head and neck, extremities, and thorax. In addition, the incidence of severe injury among elderly patients was nearly 1.6 times higher than that of non-elderly patients. According to age group, injured body regions among the elderly were the thorax, head and neck, and extremities, in that order. For the non-elderly groups, these were head and neck, extremities, and thorax. Severe injury rates were slightly different for the elderly group (head and neck, abdomen) and non-elderly group (thorax, head and neck).Conclusions: In both age groups, the rate of severe injury is proportional to an increase in crush extent zone. Front airbag deployment may have a relatively significant relationship to severe injuries. 相似文献
158.
Comparisons of polybrominated diphenyl ethers levels in paired South Korean cord blood, maternal blood, and breast milk samples 总被引:1,自引:0,他引:1
Kim TH Bang du Y Lim HJ Won AJ Ahn MY Patra N Chung KK Kwack SJ Park KL Han SY Choi WS Han JY Lee BM Oh JE Yoon JH Lee J Kim HS 《Chemosphere》2012,87(1):97-104
Polybrominated diphenyl ethers (PBDEs), commonly used flame retardants, have been reported as potential endocrine disruptor and neurodevelopmental toxicants, thus giving rise to the public health concern. The goal of this study was to investigate the relationship between umbilical cord blood, maternal blood, and breast milk concentrations of PBDEs in South Korean. We assessed PBDE levels in paired samples of umbilical cord blood, maternal blood, and breast milk. The levels of seven PBDE congeners were measured in 21 paired samples collected from the Cheil Woman’s Hospital (Seoul, Korea) in 2008. We also measured thyroid hormones levels in maternal and cord blood to assess the association between PBDEs exposure and thyroid hormone levels. However, there was no correlation between serum thyroxin (T4) and total PBDEs concentrations. The total PBDEs concentrations in the umbilical cord blood, maternal blood, and breast milk were 10.7 ± 5.1 ng g−1 lipid, 7.7 ± 4.2 ng g−1 lipid, and 3.0 ± 1.8 ng g−1 lipid, respectively. The ranges of total PBDE concentrations observed were 2.28-30.94 ng g−1 lipid in umbilical cord blood, 1.8-17.66 ng g−1 lipid in maternal blood, and 1.08-8.66 ng g−1 lipid in breast milk. BDE-47 (45-73% of total PBDEs) was observed to be present dominantly in all samples, followed by BDE-153. A strong correlation was found for major BDE-congeners between breast milk and cord blood or maternal blood and cord blood samples. The measurement of PBDEs concentrations in maternal blood or breast milk may help to determine the concentration of PBDEs in infant. 相似文献
159.
Oh T Kim M Lim J Kang O Shetty KV SankaraRao B Yoo C Park JH Kim JT 《Journal of the Air & Waste Management Association (1995)》2012,62(5):517-526
Subway systems are considered as main public transportation facility in developed countries. Time spent by people in indoors, such as underground spaces, subway stations, and indoor buildings, has gradually increased in the recent past. Especially, operators or old persons who stay in indoor environments more than 15 hr per day usually influenced a greater extent by indoor air pollutants. Hence, regulations on indoor air pollutants are needed to ensure good health of people. Therefore, in this study, a new cumulative calculation method for the estimation of total amounts of indoor air pollutants emitted inside the subway station is proposed by taking cumulative amounts of indoor air pollutants based on integration concept. Minimum concentration of individual air pollutants which naturally exist in indoor space is referred as base concentration of air pollutants and can be found from the data collected. After subtracting the value of base concentration from data point of each data set of indoor air pollutant, the primary quantity of emitted air pollutant is calculated. After integration is carried out with these values, adding the base concentration to the integration quantity gives the total amount of indoor air pollutant emitted. Moreover the values of new index for cumulative indoor air quality obtained for 1 day are calculated using the values of cumulative air quality index (CAI). Cumulative comprehensive indoor air quality index (CCIAI) is also proposed to compare the values of cumulative concentrations of indoor air pollutants. From the results, it is clear that the cumulative assessment approach of indoor air quality (IAQ) is useful for monitoring the values of total amounts of indoor air pollutants emitted, in case of exposure to indoor air pollutants for a long time. Also, the values of CCIAI are influenced more by the values of concentration of NO2, which is released due to the use of air conditioners and combustion of the fuel. The results obtained in this study confirm that the proposed method can be applied to monitor total amounts of indoor air pollutants emitted, inside apartments and hospitals as well. Implications: Nowadays, subway systems are considered as main public transportation facility in developed countries. Time spent by people in indoors, such as underground spaces, subway stations, and indoor buildings, has gradually increased in the recent past. Especially, operators or old persons who stay in the indoor environments more than 15 hr per day usually influenced a greater extent by indoor air pollutants. Hence, regulations on indoor air pollutants are needed to ensure good health of people. Therefore, this paper presents a new methodology for monitoring and assessing total amounts of indoor air pollutants emitted inside underground spaces and subway stations. A new methodology for the calculation of cumulative amounts of indoor air pollutants based on integration concept is proposed. The results suggest that the cumulative assessment approach of IAQ is useful for monitoring the values of total amounts of indoor air pollutants, if indoor air pollutants accumulated for a long time, especially NO2 pollutants. The results obtained here confirm that the proposed method can be applied to monitor total amounts of indoor air pollutants emitted, inside apartments and hospitals as well. 相似文献
160.
Eun-Ah Kim Hang Vo-Minh Nguyen Hae Sung Oh Jin Hur Jung Hyun Choi 《Environmental science and pollution research international》2016,23(6):5203-5213
This study investigated the effects of various soil conditions, including drying-rewetting, nitrogen deposition, and temperature rise, on the quantities and the composition of dissolved organic matter leached from forest and wetland soils. A set of forest and wetland soils with and without the nitrogen deposition were incubated in the growth chambers under three different temperatures. The moisture contents were kept constant, except for two-week drying intervals. Comparisons between the original and the treated samples revealed that drying-rewetting was a crucial environmental factor driving changes in the amount of dissolved organic carbon (DOC). The DOC was also notably increased by the nitrogen deposition to the dry forest soil and was affected by the temperature of the dry wetland soil. A parallel factor (PARAFAC) analysis identified three sub-fractions of the fluorescent dissolved organic matter (FDOM) from the fluorescence excitation–emission matrices (EEMs), and their compositions depended on drying-rewetting. The data as a whole, including the DOC and PARAFAC components and other optical indices, were possibly explained by the two main variables, which were closely related with the PARAFAC components and DOC based on principal component analysis (PCA). Our results suggested that the DOC and PARAFAC component information could provide a comprehensive interpretation of the changes in the soil-leached DOM in response to the different environmental conditions. 相似文献