全文获取类型
收费全文 | 220篇 |
免费 | 3篇 |
专业分类
安全科学 | 4篇 |
废物处理 | 18篇 |
环保管理 | 18篇 |
综合类 | 8篇 |
基础理论 | 38篇 |
环境理论 | 1篇 |
污染及防治 | 74篇 |
评价与监测 | 52篇 |
社会与环境 | 9篇 |
灾害及防治 | 1篇 |
出版年
2023年 | 5篇 |
2022年 | 12篇 |
2021年 | 9篇 |
2020年 | 5篇 |
2019年 | 7篇 |
2018年 | 8篇 |
2017年 | 13篇 |
2016年 | 9篇 |
2015年 | 5篇 |
2014年 | 21篇 |
2013年 | 24篇 |
2012年 | 12篇 |
2011年 | 12篇 |
2010年 | 9篇 |
2009年 | 7篇 |
2008年 | 13篇 |
2007年 | 10篇 |
2006年 | 8篇 |
2005年 | 7篇 |
2004年 | 5篇 |
2003年 | 10篇 |
2002年 | 4篇 |
1998年 | 5篇 |
1996年 | 1篇 |
1994年 | 1篇 |
1990年 | 1篇 |
排序方式: 共有223条查询结果,搜索用时 15 毫秒
81.
The aim of this research is to determine the effects of Izmir Big Channel Waste Water Treatment Project on the sediment quality of Izmir Bay. Wastewater treatment improves the water quality. However, sediment does not respond to this treatment as fast as water column. Monitoring of bottom water and sediment quality is necessary for identification of the recovery of the whole ecosystem. For this purpose, bottom water and sediment samples were collected from three stations which are located in the middle and inner parts of the Izmir Bay on a monthly basis between January 2003 and December 2003. Values measured at stations ranged between; 0.54-12.82 microg/L for chlorophyll-a, 0.09-9.32 microg/L for phaeopigment, 0.05-1.91 mg/L for particulate organic carbon in bottom waters, 11.88-100.29 microg/g for chlorophyll degradation products and 1.12-5.39% for organic carbon in sediment samples. In conclusion, it was found that grazing activity explained carbon variations in sediment at station 2, but at station 1 and station 3 carbon variations in sediment were not related to autochthonous biological processes. 相似文献
82.
Mehmet Bac 《Natural resources forum》1998,22(4):263-269
The property rights regime is an important link between the yield of a natural resource and the appropriation and maintenance incentives of its users. This paper discusses the theoretical background for this link and provides insights as to the function of the property rights regime, drawing from recent developments in the economics literature on optimal ownership patterns and the theory of repeated games. The performances of different resource ownership patterns are evaluated using the criterion of economic efficiency. The economic theory of property rights is based on the idea that, because contractual arrangements are bound to be incomplete, there is scope for opportunistic behaviour and therefore the resulting resource management is likely to be inefficient. Optimal resource ownership patterns are viewed as solutions to the problem of structuring private users' incentives in accordance with the socially desirable management of resources. 相似文献
83.
Mustafa Arslan Cihan Alkan Mehmet Cici Mehmet Kaya 《Resources, Conservation and Recycling》1994,10(4)
FeSO4·xH2O is generated in large amounts in galvanizing workshops. It can be reutilized by conversion to Fe2O3. In this study, the recovery of Fe2O3 from FeSO4·xH2O formed in the galvanizing process has been examined. The experimental work was carried out at various temperatures and times in the oxidizing medium. The reaction temperatures and times were selected as 450, 500, 550, 600, 650, 700, 800 and 900°C, and 15, 30, 45, 60, 90 and 120 minutes, respectively. In order to determine the amount of Fe2O3, a titrimetric method was applied. The reaction products were characterized by means of IR and XRD techniques.The extent of conversion is low at temperatures below 650°C. Almost all of the iron (II) sulfate in the original sample was converted to iron(III) oxide at 650°C (120 min), 700°C (90 min), 800°C (60 min) and 900°C (45 min). 相似文献
84.
Zekai Sen Abdulaziz Abo Saud Abdüsselam Altunkaynak Mehmet
zger 《Journal of the American Water Resources Association》2003,39(5):1209-1215
ABSTRACT: The quality of ground water in any aquifer takes its final form due to natural mixture of waters, which may originate from different sources. Water quality varies from one aquifer to another and even within the same aquifer itself. Different ground water quality is obtained from wells and is mixed in a common reservoir prior to any consumption. This artificial mixing enables an increase in available ground water of a desired quality for agricultural or residential purposes. The question remains as to what proportions of water from different wells should be mixed together to achieve a desired water quality for this artificial mixture. Two sets of laboratory experiments were carried out, namely, the addition of saline water to a fixed volume of fresh water. After each addition, the mixture volume and the electric conductivity value of the artificially mixed water were recorded. The experiments were carried out under the same laboratory temperature of 20°C. A standard curve was developed first experimentally and then confirmed theoretically. This curve is useful in determining either the volume or discharge ratio from two wells to achieve a predetermined electrical conductivity value of the artificial mixture. The application of the curve is given for two wells within the Quaternary deposits in the western part of the Kingdom of Saudi Arabia. 相似文献
85.
Modeling individual tree mortality for crimean pine plantations 总被引:1,自引:0,他引:1
Misir M Misir N Yavuz H 《Journal of environmental biology / Academy of Environmental Biology, India》2007,28(2):167-172
Individual tree mortality model was developed for crimean pine (Pinus nigra subsp. pallasiana) plantations in Turkey. Data came from 5 year remeasurements of the permanent sample plots. The data comprises of 115 sample plots with 5029 individual trees. Parameters of the logistic equation were estimated using weighted nonlinear regression analysis. Approximately 80% of the observations were used for model development and 20% for validation. The explicatory variables in the model were ratio of diameter of the subject tree and basal area mean diameter of the sample plot as measure of competition index for individual trees, basal area and site index. All parameter estimates were found highly significant (p < 0.001) in predicting mortality model. Chi-square statistics indicate that the most important variable is d / d(q), the second most important is site index, and the third most important predictor is stand basal area. Examination of graphs of observed vs. predicted mortality rates reveals that the mortality model is well behaved and match the observed mortality rates quite well. Although the phenomenon of mortality is a stochastic, rare and irregular event, the model fit was fairly good. The logistic mortality model passed a validation test on independent data not used in parameter estimation. The key ingredient for obtaining a good mortality model is a data set that is both large and representative of the population under study and the data satisfy both requirements. The mortality model presented in this paper is considered to have an appropriate level of reliability. 相似文献
86.
Decolorization of remazol yellow RR gran by white rot fungus Phanerochaete chrysosporium 总被引:1,自引:0,他引:1
Demir G Ozcan HK Tufekci N Borat M 《Journal of environmental biology / Academy of Environmental Biology, India》2007,28(4):813-817
In this study, the removal of color, chemical oxygen demand (COD) and aromatic group from one of the azo dyes, Remazol Yellow RR Gran, had been carried out by using one of the white rot fungi, Phanerochaete chrysosporium. Experimental studies were performed in growth media containing different amounts of dye and glucose. Color measurements were done at 436nm wavelength using spectrophotometer while aromatic group measurements were done at 280 nm wavelength using UV/Visible spectrophotometer. As a result of this study the values of the removable color concentration were determined as 10 mgl(-1) and lower. The optimum medium glucose concentration was determined to be 2 gl(-1) during color removal processes, aromatic group measurements were done in samples in the UV region at 280 nm wavelength. As a result of the measurements, it was shown that certain amount of aromatic group remained in the model wastewater at the end of the process. 相似文献
87.
Mehmet?CetinEmail authorView authors OrcID profile Fatih?Adiguzel Omer?Kaya Ahmet?Sahap 《Environment, Development and Sustainability》2018,20(1):361-375
People are relaxed (satisfied or well-off) in what is described as comfortable climatic conditions. In such conditions, a person’s energy balance is not disturbed because of stresses from extreme heat or cold. Bioclimatic structure has been well researched and should be a consideration in the planning process for arranging comfortable spaces. It represents the understanding that energy balance is one of the basic elements of a sustainable landscape design. The goals of this study have been to create ideal places for human thermal comfort and to advance objectives focused on the importance of sustainable and ecological landscape planning and design work, along with their accompanying economic benefits. In this study, which focuses on the climate of the Province of Aydin, the most suitable areas for bioclimatic comfort have been identified. The climate values for the Aydin Province have been taken from a total of 22 meteorological stations. Stations at altitudes ranging from 11 to 871 m were used to note the climate changes that occurred. The average temperature, relative humidity, and wind speed from each station, including data collected using Geographic Information System (GIS) software, were transferred. GIS maps were then created from the imported data, and areas of optimal comfort around the city of Aydin were determined. The results show the range that is suitable for a bioclimatic comfort zone in Aydin. The bioclimatic comfort range was determined to be roughly 17 °C for Aydin, and the city of Aydin demonstrated a comfort range between 14 and 19 °C. As a result, the city of Aydin was shown to be a suitable area for bioclimatic comfort. 相似文献
88.
Senkal O Yıldız BY Şahin M Pestemalcı V 《Environmental monitoring and assessment》2012,184(1):141-147
Precipitable water (PW) is an important atmospheric variable for climate system calculation. Local monthly mean PW values were measured by daily radiosonde observations for the time period from 1990 to 2006. Artificial neural network (ANN) method was applied for modeling and prediction of mean precipitable water data in Çukurova region, south of Turkey. We applied Levenberg–Marquardt (LM) learning algorithm and logistic sigmoid transfer function in the network. In order to train our neural network we used data of Adana station, which are assumed to give a general idea about the precipitable water of Çukurova region. Thus, meteorological and geographical data (altitude, temperature, pressure, and humidity) were used in the input layer of the network for Çukurova region. Precipitable water was the output. Correlation coefficient (R2) between the predicted and measured values for monthly mean daily sum with LM method values was found to be 94.00% (training), 91.84% (testing), respectively. The findings revealed that the ANN-based prediction technique for estimating PW values is as effective as meteorological radiosonde observations. In addition, the results suggest that ANN method values be used so as to predict the precipitable water. 相似文献
89.
Mert Gürtürk Ahmet Koca Yasin Varol Mehmet Şekerci 《International Journal of Green Energy》2017,14(12):1073-1080
Solar energy is one of the most important renewable energy sources, but it is not available every time and every season. Thus, storing of solar energy is important. One of the popular methods of heat storage is use of phase change materials (PCMs) which have large thermal energy storage capacity. In this study, the heat storage tank in a domestic solar water heating system was chosen as control volume. The experiments were performed in the province of Elaz?g, Turkey, in November when solar radiation was weak due to cloudy sky. The heat storage tank of the system was modified to fill PCM between insulation and hot water part. A few PCMs which are Potassium Fluoride, Lithium Metaborate Dihydrate, Strontium Hydroxide Octahydrate, Barium Hydroxide Octahydrate, Aluminum Ammonium Sulfate, and Sodium Hydrogen Phosphate were analyzed to proper operating conditions using a Differential Scanning Calorimeter (DSC) and the best PCM was obtained with the Aluminum Ammonium Sulfate and Sodium Hydrogen Phosphate mixture. Thus, eutectic PCM was obtained and used in a heat storage tank of the solar water heating system. Energy and exergy analysis of heat storage tank was performed with and without the PCM. Energy and exergy analysis has shown that the heat storage tank with the PCM is more efficient than without the PCM and the maximum exergy efficiency was obtained as 22% with the heat storage tank with the PCM. 相似文献
90.