1
1.
2.
The main aim of this study is to criticize the process of selecting the most appropriate site for the disposal of municipal solid wastes which is one of the problematic issues of waste management operations. These kinds of problems are pathological symptoms of existing problematical human–nature relationship which is related to the syndrome called ecological crisis. In this regard, solving the site selection problem, which is just a small part of a larger entity, for the good of ecological rationality and social justice is only possible by founding a new and extensive type of human–nature relationship. In this study, as a problematic point regarding the discussions on ecological problems, the existing structure of the applications using multi-criteria decision analysis in the process of site selection with three main criteria is criticized. Based on this critique, fundamental problematic points (to which applications are insufficient to find solutions) will be defined. Later, some modifications will be suggested in order to provide solutions to these problematical points. Finally, the criticism addressed to the structure of the method with three main criteria and the feasibility of the new method with four main criteria is subjected to an evaluation process. As a result, it is emphasized that the new structure with four main criteria may be effective in solution of the fundamental problematic points.  相似文献   
3.
The procedure of a multi-criteria decision analysis supported by the geographic information systems was applied to the site selection process of a planning municipal solid waste management practice based on twelve different scenarios. The scenarios included two different decision tree modes and two different weighting models for three different area requirements. The suitability rankings of the suitable sites obtained from the application of the decision procedure for the scenarios were assessed by a factorial experimental design concerning the effect of some external criteria on the final decision of the site selection process. The external criteria used in the factorial experimental design were defined as “Risk perception and approval of stakeholders” and “Visibility”. The effects of the presence of these criteria in the decision trees were evaluated in detail. For a quantitative expression of the differentiations observed in the suitability rankings, the ranking data were subjected to ANOVA test after a normalization process. Then the results of these tests were evaluated by Tukey test to measure the effects of external criteria on the final decision. The results of Tukey tests indicated that the involvement of the external criteria into the decision trees produced statistically meaningful differentiations in the suitability rankings. Since the external criteria could cause considerable external costs during the operation of the disposal facilities, the presence of these criteria in the decision tree in addition to the other criteria related to environmental and legislative requisites could prevent subsequent external costs in the first place.

Implications:

An experimental design was applied to a siting process based on different scenarios. The suitability rankings of suitable sites were obtained for each scenario. The external criteria used in the design were defined as perception and visibility. The presence of the external criteria produced meaningful differentiations. Two widespread persuasions about site selection were disproved using the results.  相似文献   

4.
Occupational exposure to benzene was measured in two gasoline marketing terminals and five major refineries in Singapore. A total of 280 workers were monitored over two years. This assessment was carried out with two primary objectives: (1) To find out the extent of occupational exposure to benzene in the petroleum industry in Singapore, (2) To identify suitable biomarkers for monitoring of low levels of benzene exposure. The exposure was measured in five different categories of petroleum and petrochemical workers, i.e., truck drivers, despatch assistant, process operators, oil movements operators and laboratory technicians. The results revealed wide variations in exposure, from 0.01 to 13.6 ppm for personal time weighted average (TWA) exposure over the whole workshift. The exposure of truck drivers appeared to be the highest, with geometric mean (GM) of 1.98 ppm (ranged from 0.25 to 13.6 ppm). The average benzene exposure for process operators was relative low with a GM of 0.04 ppm. Lowest benzene exposure was found in the laboratory technicians, with a GM of 0.02 ppm. As cigarette smoking is known to affect metabolism of benzene, data analyses on the relationships with environmental exposure were conducted only on the 190 nonsmokers. The results showed that urinary trans, trans-muconic acid (ttMA), unmetabolized benzene in urine (UBZ) and benzene in blood (BBZ) were better biomarkers for low level benzene exposure as compared to urinary phenolic metabolites in urine, such as hydroquinone, phenol and catechol.  相似文献   
5.
Journal of Material Cycles and Waste Management - Selecting a system for treatment and disposal of municipal solid wastes (i.e., selection of the capacity, location and type of the processes and...  相似文献   
6.
A study was conducted to observe the changes in polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/F) levels and congener profiles in the flue gas of a hazardous waste incinerator during two start-up periods. Flue gas samplings were performed simultaneously through Air Pollution Control Devices (APCDs) (including boiler outlet, electrostatic precipitator (ESP) outlet, wet scrubbers (WS) outlet, and activated carbon (AC) filter outlet) in different combustion temperatures during a planned cold (long) start-up and an unplanned warm (short) start-up. The results showed that PCDD/F concentrations could be elevated during the start-up periods up to levels 3–4 times higher than those observed in the normal operation. Especially lower combustion temperatures in the short start-ups may cause high PCDD/F concentrations in the raw flue gas. Assessment of combustion temperatures and Furans/Dioxins values indicated that surface-catalyzed de novo synthesis was the dominant pathway in the formation of PCDD/Fs in the combustion units. PCDD/F removal efficiencies of Air Pollution Control Devices suggested that formation by de novo synthesis existed in ESP also when in operation, leading to increase of gaseous phase PCDD/Fs in ESP. Particle-bound PCDD/Fs were removed mainly by ESP and WS, while gaseous phase PCDD/Fs were removed by WS, and more efficiently by AC filter.

Implications: This paper evaluates PCDD/F emissions and removal performances of APCDs (ESP, wet scrubbers, and activated carbon) during two start-up periods in an incinerator. The main implications are the following: (1) start-up periods increase PCDD/F emissions up to 2–3 times in the incinerator; (2) low combustion temperatures in start-ups cause high PCDD/F emissions in raw gas; (3) formation of PCDD/Fs by de novo synthesis occurs in ESP; (4) AC is efficient in removing gaseous PCDD/Fs, but may increase particle-bound ones; and (5) scrubbers remove both gaseous and particle-bound PCDD/Fs efficiently.  相似文献   
7.
This study is the first to investigate the contamination of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) on surface soils in the vicinity of the first hazardous waste incinerator of Turkey. In the study, 24 soil samples were taken from a 1625-m-radius circle whose center is the stack of the incinerator. This process was repeated 1 year later. Since the acquired average PCDD/F concentrations of the two sampling campaigns (0.05 and 0.02 ng WHO-toxic equivalent (TEQ)/kg) were meaningfully low compared to the related literatures, a new sampling campaign was carried out to control this inconsistency, but this time in a foreign laboratory (0.56 ng WHO-TEQ/kg). In the same period, eight gas samples were taken from the stack under different operational conditions of the facility. According to the evaluations of the findings, the geographical-meteorological data of the study area and the specific operational conditions of the facility corroborate the concentrations of the first and the second soil samplings rather than the third one. The major underlying reason for the inconsistency of the soil concentrations may be the fact that the data analysis procedures used by the laboratories are different. The author suggests a hypothesis which argues that the soils in the vicinity of a hazardous waste incinerator may have significantly lower concentration levels than in related literatures.  相似文献   