Polyethylene laminated disposable paper cups are commonly used as a container for hot drinks, yet there is limited knowledge on the transfer of contaminants from the cup to the drink. Here we poured 95?C hot water in 14 cups, to simulate the preparation of hot beverage for daily use. We studied the water composition after 15 min by inductively coupled plasma mass spectrometry (ICP-MS) and ion chromatography. Results show the presence of metals such as vanadium, chromium, copper, cobalt and arsenic at concentration ranging from 0.04 to 1.80 µg/L. Nitrate, nitrite, chloride, bromate, fluoride and sulfate ions were also detected at concentration from 0.003 to 49.21 mg/L. All concentrations are below the WHO maximum permissible limits in drinking water. However, the levels of vanadium at 1.24 µg/L and fluoride ions at 1.03 mg/L are likely to induce a health risk by bioaccumulation after long-term water ingestion. Therefore paper cups composition should be modified to avoid the release of contaminants in hot drinks.