首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   7篇
  免费   0篇
废物处理   1篇
污染及防治   4篇
评价与监测   1篇
社会与环境   1篇
  2017年   1篇
  2014年   1篇
  2013年   2篇
  2007年   1篇
  2005年   1篇
  2004年   1篇
排序方式: 共有7条查询结果,搜索用时 53 毫秒
1
1.
The procedure of a multi-criteria decision analysis supported by the geographic information systems was applied to the site selection process of a planning municipal solid waste management practice based on twelve different scenarios. The scenarios included two different decision tree modes and two different weighting models for three different area requirements. The suitability rankings of the suitable sites obtained from the application of the decision procedure for the scenarios were assessed by a factorial experimental design concerning the effect of some external criteria on the final decision of the site selection process. The external criteria used in the factorial experimental design were defined as “Risk perception and approval of stakeholders” and “Visibility”. The effects of the presence of these criteria in the decision trees were evaluated in detail. For a quantitative expression of the differentiations observed in the suitability rankings, the ranking data were subjected to ANOVA test after a normalization process. Then the results of these tests were evaluated by Tukey test to measure the effects of external criteria on the final decision. The results of Tukey tests indicated that the involvement of the external criteria into the decision trees produced statistically meaningful differentiations in the suitability rankings. Since the external criteria could cause considerable external costs during the operation of the disposal facilities, the presence of these criteria in the decision tree in addition to the other criteria related to environmental and legislative requisites could prevent subsequent external costs in the first place.

Implications:

An experimental design was applied to a siting process based on different scenarios. The suitability rankings of suitable sites were obtained for each scenario. The external criteria used in the design were defined as perception and visibility. The presence of the external criteria produced meaningful differentiations. Two widespread persuasions about site selection were disproved using the results.  相似文献   

2.
A multimedia risk assessment procedure was conducted to determine the fate and transport of polychlorinated dibenzo-p-dioxin and polychlorinated dibenzofuran (PCDD/F) emissions from the Izmit Hazardous and Medical Waste Incinerator (IZAYDAS) in Turkey and their potential health risks. Congener concentrations in ambient air and their deposition rates were determined by an air dispersion model (ISCST3). Their transfer to some plant groups and animal tissues was predicted by food chain modeling. Exposure scenarios were produced based on three receptor groups (urban, semiurban, and rural) and five subgroups determined according to ages. Daily intakes of PCDD/Fs via exposure pathways were determined based on three different emission scenarios for each group and subgroup. Estimated incremental PCDD/F doses caused by the incinerator emissions in central-tendency scenario were computed as between 2.31 x 10(-6) and 0.008 pg TEQ kg(-1) bodyweight (bw) day(-1) on average for all the receptors other than infants in all the settings, while the range was 3.01 x 10(-5)-0.081 pg TEQ kg(-1) bw day(-1) for infants. Sensitivity analysis showed that the consumption of vegetal products and their locally grown fractions are the most significant parameters in the exposure to PCDD/Fs in the area.  相似文献   
3.
This study aims to obtain a reliable inventory of the emission rates of the principal air pollutants including PM, SO2, NOx) and CO in Kocaeli, Turkey. In the first stage, the pollutant sources classified as point, area and line sources are determined in the area. Then the annual emission rates of the pollutants released from these sources are estimated by the emission factors given by USEPA and CORINAIR. Results show that the annual emission rates for PM, SO2, NOx) and CO are 2195 tons, 5342 tons, 14632 tons and 23095 tons, respectively. On the other hand, the pollutant group with the highest contribution to total emission rate is determined as the point sources for NOx, which is responsible for 73% of total NOx emission, while it is the area sources for PM, SO2 and CO with the contribution percentages of 75, 76 and 69, respectively.  相似文献   
4.
PCDD/F analyses were made in soil and ambient air samples taken from Kocaeli, an industrialized area of Turkey. Results showed that the levels of PCDD/F pollution are comparable to the levels observed in the various urban areas in the world. PCDD/F concentrations in surface soils ranged between 0.4 and 4.27 pg I-TEQ kg(-1) with a geometric mean of 0.76 pg I-TEQ kg(-1), while those in ambient air were between 23 and 563 f gm(-3), with geometric mean of 82.0 f gm(-3). Ambient air PCDD/F concentration in the city center was about 10 times higher than those in the rural area. Combustion activities present in the area were assessed to be the most significant source of the PCDD/F pollution based on the congener and homologue profiles and statistical analysis of the data. The deposition rate modeling of USEPA was applied and the deposition rates were determined in the range between 7.6 and 66.3 ng I-TEQ m(-2)year(-1) with a geometric mean of 15.9 ng I-TEQ m(-2)year(-1). The rates were higher than the recommended deposition rates in relation to the tolerable daily intake (TDI) range of PCDD/Fs for humans. The deposition velocities computed were also found to be high in both low and highly chlorinated PCDD/Fs, and this was attributed to the vapor phase deposition of volatile PCDD/Fs, and the scavenging effect of the precipitation on the particle-bound PCDD/Fs.  相似文献   
5.
Journal of Material Cycles and Waste Management - Selecting a system for treatment and disposal of municipal solid wastes (i.e., selection of the capacity, location and type of the processes and...  相似文献   
6.
This study evaluates PCDD/F pollution in the surface sediments of Izmit Bay (Turkey) and assesses the possible sources of PCDD/F inputs to the bay. The results showed that concentrations of toxic PCDD/F congeners in the sediments varied between 0.45 and 255 ng WHO2005-TEQ/kg dry weight. Pollution mapping shows that PCDD/F levels in the central section of Izmit Bay are much higher than those in the eastern and the western sections. Sediments collected from the northern part of the central section showed very high PCDD/F concentrations. The samples reveal three different congener profiles dominated by OCDF, 1,2,3,4,6,7,8-HpCDF, and OCDD respectively. The dominance of OCDF in the sediment samples taken from the central section was attributed to the former production of vinyl chloride monomer in the area, while that of 1,2,3,4,6,7,8-HpCDF was attributed to the (previously unknown) use of a chlorophenol-based fungicide in the region. The OCDD dominated group was explained by the use of pentachlorophenol. The results indicate that historic industrial discharges are the main contributor to the PCDD/F pollution in the sediments.  相似文献   
7.
A study was conducted to observe the changes in polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/F) levels and congener profiles in the flue gas of a hazardous waste incinerator during two start-up periods. Flue gas samplings were performed simultaneously through Air Pollution Control Devices (APCDs) (including boiler outlet, electrostatic precipitator (ESP) outlet, wet scrubbers (WS) outlet, and activated carbon (AC) filter outlet) in different combustion temperatures during a planned cold (long) start-up and an unplanned warm (short) start-up. The results showed that PCDD/F concentrations could be elevated during the start-up periods up to levels 3–4 times higher than those observed in the normal operation. Especially lower combustion temperatures in the short start-ups may cause high PCDD/F concentrations in the raw flue gas. Assessment of combustion temperatures and Furans/Dioxins values indicated that surface-catalyzed de novo synthesis was the dominant pathway in the formation of PCDD/Fs in the combustion units. PCDD/F removal efficiencies of Air Pollution Control Devices suggested that formation by de novo synthesis existed in ESP also when in operation, leading to increase of gaseous phase PCDD/Fs in ESP. Particle-bound PCDD/Fs were removed mainly by ESP and WS, while gaseous phase PCDD/Fs were removed by WS, and more efficiently by AC filter.

Implications: This paper evaluates PCDD/F emissions and removal performances of APCDs (ESP, wet scrubbers, and activated carbon) during two start-up periods in an incinerator. The main implications are the following: (1) start-up periods increase PCDD/F emissions up to 2–3 times in the incinerator; (2) low combustion temperatures in start-ups cause high PCDD/F emissions in raw gas; (3) formation of PCDD/Fs by de novo synthesis occurs in ESP; (4) AC is efficient in removing gaseous PCDD/Fs, but may increase particle-bound ones; and (5) scrubbers remove both gaseous and particle-bound PCDD/Fs efficiently.  相似文献   