首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   40篇
  免费   0篇
安全科学   1篇
环保管理   7篇
综合类   3篇
基础理论   2篇
污染及防治   25篇
社会与环境   2篇
  2013年   18篇
  2011年   3篇
  2010年   2篇
  2008年   2篇
  2007年   1篇
  2006年   1篇
  2005年   2篇
  2004年   1篇
  2003年   2篇
  2002年   2篇
  1995年   1篇
  1978年   1篇
  1975年   1篇
  1971年   1篇
  1968年   1篇
  1967年   1篇
排序方式: 共有40条查询结果,搜索用时 153 毫秒
1.
Surface runoff losses of copper and zinc in sandy soils   总被引:1,自引:0,他引:1  
Increased anthropogenic inputs of Cu and Zn in soils have caused considerable concern relative to their effect on water contamination. Copper and Zn contents in surface soil directly influence the movement of Cu and Zn. However, minimal information is available on runoff losses of Cu and Zn in agricultural soils, and soil-extractable Cu and Zn in relation to runoff water quality. Field experiments were conducted in 2001 to study dissolved Cu and Zn losses in runoff in Florida sandy soils under commercial citrus and vegetable production and the relationship between soil-extractable Cu and Zn forms and dissolved Cu and Zn concentrations in runoff water. Five extraction methods were compared for extracting soil available Cu and Zn. Concentrations of dissolved Cu and Zn in runoff were measured and runoff discharge was monitored. Mean dissolved Cu in field runoff water was significantly correlated with the extractable Cu obtained only by 0.01 mol L(-1) CaCl2, Mehlich 1, or DTPA-TEA methods. Dissolved Zn in runoff water was only significantly correlated with extractable Zn by 0.01 mol L(-1) CaCl2. The highest correlations to dissolved Cu in runoff were obtained when soil-available Cu was extracted by 0.01 mol L(-1) CaCl2. The results indicate that 0.01 mol L(-1) CaCl2-extractable Cu and Zn are the best soil indexes for predicting readily released Cu and Zn in the sandy soils. Both runoff discharge and 0.01 mol L(-1) CaCl2-extractable Cu and Zn levels had significant influences on Cu and Zn loads in surface runoff.  相似文献   
2.
建立我国生态环境标准体系的初步构想   总被引:9,自引:0,他引:9  
我国的生态环境标准极其薄弱,建立生态环境标准体系是我国生态环境保护的迫切需要。借鉴我国目前针对污染防治的环境标准体系,提出了我国生态环境标准体系的基本框架,以及生态环境标准制订的原则和重点。  相似文献   
3.
4.
Attenuation of rainfall within the solum may help to move contaminants and nutrients into the soil to be better sequestered or utilized by crops. Surface application of phosphorus (P) amendments to grasslands may lead to elevated concentrations of P in surface runoff and eutrophication of surface waters. Aeration of grasslands has been proposed as a treatment to reduce losses of applied P. Here, results from two small-plot aeration studies and two field-scale, paired-watershed studies are supplemented with previously unpublished soil P data and synthesized. The overall objective of these studies was to determine the impact of aeration on soil P, runoff volume, and runoff P losses from mixed tall fescue [Lolium arundinaceum (Schreb.) Darbysh.]-bermudagrass (Cynodon dactylon L.) grasslands fertilized with P. Small-scale rainfall simulations were conducted on two soil taxa using three types of aeration implements: spikes, disks, and cores. The-field scale study was conducted on four soil taxa with slit and knife aeration. Small-plot studies showed that core aeration reduced loads of total P and dissolved reactive P (DRP) in runoff from plots fertilized with broiler litter and that aeration was effective in reducing P export when it increased soil P in the upper 5 cm. In the field-scale study, slit aeration reduced DRP losses by 35% in fields with well-drained soils but not in poorly drained soils. Flow-weighted concentrations of DRP in aerated fields were related to water-soluble P applied in amendments and soil test P in the upper 5 cm. These studies show that the overall effectiveness of mechanical soil aeration on runoff volume and P losses is controlled by the interaction of soil characteristics such as internal drainage and compaction, soil P, type of surface-applied manure, and type of aeration implement.  相似文献   
5.
Abstract

A major component of the Southern Oxidants Study (SOS) 1992 Atlanta Intensive was the measurement of atmospheric nonmethane hydrocarbons. Ambient air samples were collected and analyzed by a network of strategically located automated gas chromatography (GC) systems (field systems). In addition, an extensive canister sampling network was deployed. Combined, more than 3000 chromatograms were recorded. The SOS science team targeted for quantitative analysis 56 compounds which may be substantial contributors to ozone formation or used as air mass tracers. A quality assurance program was instituted to ensure that good measurements were being made throughout the network for each target compound. Common, high-quality standards were used throughout the network. The performance of individual field systems was evaluated during the intensive through the analysis of challenge mixtures. This methodology helped to identify and correct analytical problems as they arose.  相似文献   
6.
The TR-l Research Committee of the Air Pollution Control Association conducted a survey during 1969–70 to determine what air pollution research problems require attention. All APCA committees were requested to contribute topics to this survey, especially within their area of activity. Other professional societies were contacted through liaison representatives of APCA. The responses to the survey have been reviewed, categorized, selected, and edited for inclusion in this report. Additional material and concepts have been contributed by members of the TR-l Committee.  相似文献   
7.
The object of this program was to study particle collection efficiency in venturi scrubbers in order to account for the effects of particle size and wettability, venturi size, and fluid flow rates. The body of information is directed to those interested in the prediction of particle collection efficiency in venturi scrubbers.  相似文献   
8.
9.
Conventional vacuum relief methodologies are usually protective responses; that is, they accomplish their purpose by substitution of an inert gas (usually nitrogen) for the process gases removed by an external vacuum source, or for condensable vapour collapsed by an internal process mechanism (e.g. condensation). While this approach is theoretically possible for all potential vacuum scenarios, it becomes practically impossible to implement for installations where a rapid phase change can impart near-instantaneous system pressure reductions. The procedure outlined in this paper takes a preventive approach: eliminate the source of vacuum generation before the safe lower system pressure limit is reached. For distillation and other refluxing systems, this vacuum source is usually the main overhead condenser, which is designed to collapse large volumes of condensable vapour. To eliminate the vacuum source requires elimination of the system's ability to rapidly condense vapour. This goal is accomplished by introduction of inert gas directly into the condensing system to ‘blanket’ the heat transfer surface and stop condensation. The procedure determines the rate, amount and location for introduction of inert gas. The required design data include: (i) system starting pressure, (ii) maximum allowable system vacuum, (iii) volume of the condensing system, and (iv) normal system condensing rate. By determining the rate at which the condenser removes vapour volume from the system, and designing an inert gas delivery system to meet or exceed this rate, the vacuum generation potential of the system is effectively eliminated using a much smaller quantity of inert gas than with the more traditional volume substitution methods.  相似文献   
10.
江西武夷成矿带铜多金属矿产资源远景评价与展望   总被引:1,自引:0,他引:1  
华南武夷山地区处于扬子、华夏两大构造单元交接叠加地段,构造变形复杂,中生代岩浆活动强烈,具有十分优越的成矿条件,矿产资源潜力巨大.本文以正在武夷山成矿带开展的矿产远景调查工作和资源评价工作所取得的阶段性成果为基础,分析了武夷山成矿带的成矿地质背景、主要矿床类型及近几年的找矿勘查成果,并对武夷成矿带江西省境内铜多金属矿产资源潜力进行了初步评价,划分了十七个找矿远景区.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号