全文获取类型
收费全文 | 104篇 |
免费 | 1篇 |
国内免费 | 8篇 |
专业分类
安全科学 | 8篇 |
废物处理 | 4篇 |
环保管理 | 24篇 |
综合类 | 31篇 |
基础理论 | 13篇 |
污染及防治 | 24篇 |
评价与监测 | 3篇 |
社会与环境 | 5篇 |
灾害及防治 | 1篇 |
出版年
2023年 | 3篇 |
2022年 | 2篇 |
2021年 | 1篇 |
2019年 | 2篇 |
2018年 | 1篇 |
2017年 | 2篇 |
2016年 | 4篇 |
2015年 | 3篇 |
2014年 | 7篇 |
2013年 | 11篇 |
2012年 | 4篇 |
2011年 | 4篇 |
2010年 | 4篇 |
2009年 | 7篇 |
2008年 | 7篇 |
2007年 | 6篇 |
2006年 | 3篇 |
2005年 | 5篇 |
2004年 | 5篇 |
2003年 | 3篇 |
2002年 | 5篇 |
2001年 | 2篇 |
2000年 | 2篇 |
1999年 | 1篇 |
1998年 | 2篇 |
1997年 | 3篇 |
1995年 | 1篇 |
1994年 | 1篇 |
1991年 | 1篇 |
1989年 | 2篇 |
1988年 | 1篇 |
1986年 | 1篇 |
1982年 | 1篇 |
1981年 | 2篇 |
1980年 | 1篇 |
1978年 | 2篇 |
1970年 | 1篇 |
排序方式: 共有113条查询结果,搜索用时 20 毫秒
1.
2.
We started the monitoring for PCDD/Fs in ambient air and soil in August 2001, and co-PCBs in January 2002. Decreasing of PCDD/Fs and co-PCBs levels in ambient air were observed. The higher PCDD/Fs levels were found in winter and lower in autumn. We found that the industrial incinerators influenced the PCDD/Fs levels in ambient air. In the 2,3,7,8-substituted PCDD/Fs concentration profiles, the three major congeners occupied 67% of the total mass. In case of co-PCBs, PCB#118, #105 and #77 were observed as the main congeners. Five cluster groups discriminated by ratio of four components, O(8)CDD, 1,2,3,4,6,7,8-H(7)CDD, 1,2,3,4,6,7,8-H(7)CDF and O(8)CDF, were obtained from HCA (hierarchical cluster analysis). 相似文献
3.
A kinetic model for a cycling adsorbent/photocatalyst combination for formaldehyde removal in indoor air (Chin et al. J. Catalysis 2006, 237, 29-37) was previously developed in our lab, demonstrating agreement with lab-scale batch operation data of other researchers (Shiraishi et al. Chem. Engineer. Sci. 2003, 58, 929-934). Model parameters evaluated included adsorption equilibrium and rate constants for the adsorbent (activated carbon) honeycomb rotor, and catalytic rate constant for pseudo-first-order formaldehyde destruction in the titanium dioxide photoreactor. This paper explores design consequences for this novel system. In particular, the batch parameter values are used to model both adsorbent and photocatalyst behavior for continuous operation in typical residential home challenges. Design variables, including realistic make-up air fraction, adsorbent honeycomb rotation speed, and formaldehyde source emission rate, are considered to evaluate the ability of the system to achieve World Health Organization pollutant guidelines. In all circumstances, the size of the required rotating adsorbent bed and photoreactor for single-stage operation and the resultant formaldehyde concentration in the home are calculated. The ability of how well such a system might be accommodated within the typical dimensions of commercial ventilation ducts is also considered. 相似文献
4.
Frances R. Sweetman Kenneth M. Gibson Lawrence Sweetman Ph.D William L. Nyhan Homer Chin William Swartz Oliver W. Jones 《黑龙江环境通报》1986,6(3):187-194
We have documented the presence of five mitochondrial enzymes in samples of chorionic villus tissue and measured the levels of activity. Three of the enzymes catalyse biotindependent reactions. These are propionyl-CoA carboxylase, 3-methylcrotonyl-CoA carboxylase and pyruvate carboxylase. the other enzymes. 4-aminobutyric acid aminotransferase and succinic semialdehyde dehydrogenase, are involved inthe degradation of the central inhibitory neurotransmitter GABA. Distinct diseases in whichthere is deficiency of each of these enzymes have been documented in man. Significant levels of activity were observed for all five enzymes in chorionic villus tissue. This methodology should permit early prenatal diagnosis of deficiencies of these enzymes by chorionic villus biopsy in the first trimester. 相似文献
5.
Rice husk with high volatile content was burned in a pilot scale vortexing fluidized bed incinerator. The fluidized bed incinerator was constructed of 6 mm stainless steel with 0.45 m in diameter and 5 m in height. The emission characteristics of CO, NO, and SO2 were studied. The effects of operating parameters, such as primary air flow rate, secondary air flow rate, and excess air ratio on the pollutant emissions were also investigated. The results show that a large proportion of combustion occurs at the bed surface and the freeboard zone. The SO2 concentration in the flue gas decreases with increasing excess air ratio, while the NOx concentration shows reverse trend. The flow rate of secondary air has a significant impact on the CO emission. For a fixed primary air flowrate, CO emission decreases with the secondary air flowrate. For a fixed excess air ratio, CO emission decreases with the ratio of secondary to primary air flow. The minimum CO emission of 72 ppm is attained at the operating condition of 40% excess air ratio and 0.6 partition air ratio. The NOx and SO2 concentrations in the flue gas at this condition are 159 and 36 ppm, which conform to the EPA regulation of Taiwan. 相似文献
6.
Modeling perceived collision risk in port water navigation 总被引:1,自引:0,他引:1
An increase in the likelihood of navigational collisions in port waters has put focus on the collision avoidance process in port traffic safety. The most widely used on-board collision-avoidance system is the automatic radar plotting aid which is a passive warning system that triggers an alert based on the pilot’s pre-defined indicators of distance and time proximities at the closest point of approaches in encounters with nearby vessels. To better help pilot in decision making in close quarter situations, collision risk should be considered as a continuous monotonic function of the proximities and risk perception should be considered probabilistically. This paper derives an ordered probit regression model to study perceived collision risks. To illustrate the procedure, the risks perceived by Singapore port pilots were obtained to calibrate the regression model. The results demonstrate that a framework based on the probabilistic risk assessment model can be used to give a better understanding of collision risk and to define a more appropriate level of evasive actions. 相似文献
7.
For urban community composting centers, the proper selection and use of bulking agent is a key element in not only the cost but also the quality of the finished compost. Besides wood chips (WC) widely used as BA, readily usable cereal residue pellets (CRP) can provide biodegradable carbon and sufficient free air space (FAS) to produce stabilizing temperatures. The objective of the present project was to test at a community center, the effectiveness of CRP in composting food waste (FW). Two recipes were used (CRP with and without WC) to measure: FAS; temperature regimes, and; losses in mass, water, carbon and nitrogen. Both recipes were composted during three consecutive years using a 2 m3 commercial in-vessel composter operated in downtown Montreal (Canada). For all recipes, FAS exceeded 30% for moisture content below 60%, despite yearly variations in FW and BA physical properties. When properly managed by the center operator, both FW and CRP compost mixtures with and without WC developed within 3 days thermophilic temperatures exceeding 50 °C. The loss of total mass, water, carbon and nitrogen was quite variable for both recipes, ranging from 36% to 54%, 42% to 55%, 48% to 65%, and 4% to 55%, respectively. The highest loss in dry mass, water and C was obtained with FW and CRP without WC aerated to maintain mesophilic rather than thermophilic conditions. Although variable, lower nitrogen losses were obtained with CRP and WC as BA, compared to CRP alone, as also observed during previous laboratory trials. Therefore and as BA, CRP can be used alone but nitrogen losses will be minimized by adding WC. Compost stabilization depends on operator vigilance in terms of aeration. The measured fresh compost density of 530-600 kg/m3 indicates that the 2 m3 in-vessel composter can treat 6.5 tons of FW/year if operated during 7 months. 相似文献
8.
Anne Chin Daniel L. Harris Todd H. Trice Jeffrey L. Given 《Journal of the American Water Resources Association》2002,38(6):1521-1531
ABSTRACT: In Yegua Creek, a principal tributary of the Brazos River in Texas, surveys of a 19 km channel reach downstream of Somerville Dam show that channel capacity decreased by an average of 65 percent in a 34 year period following dam closure. The decrease corresponds with an approximately 85 percent reduction in annual flood peaks. Channel depth has changed the most, decreasing by an average of 61 percent. Channel width remained stable with an average decrease of only 9 percent, reflecting cohesive bank materials along with the growth of riparian vegetation resulting from increased low flows during dry summer months. Although large changes in stream channel geometry are not uncommon downstream of dams, such pronounced reductions in channel capacity could have long‐term implications for sediment delivery through the system. 相似文献
9.
An analysis of motorcycle injury and vehicle damage severity using ordered probit models 总被引:7,自引:0,他引:7
Problem: Motorcycles constitute about 19% of all motorized vehicles in Singapore and are generally overrepresented in traffic accidents, accounting for 40% of total fatalities. Method: In this paper, an ordered probit model is used to examine factors that affect the injury severity of motorcycle accidents and the severity of damage to the vehicle for those crashes. Nine years of motorcycle accident data were obtained for Singapore through police reports. These data included categorical assessments of the severity of accidents based on three levels. Damage severity to the vehicle was also assessed and categorized into four levels. Categorical data of this type are best analyzed using ordered probit models because they require no assumptions regarding the ordinality of the dependent variable, which in this case is the severity score. Various models are examined to determine what factors are related to increased injury and damage severity of motorcycle accidents. Results: Factors found to lead to increases in the probability of severe injuries include the motorcyclist having non-Singaporean nationality, increased engine capacity, headlight not turned on during daytime, collisions with pedestrians and stationary objects, driving during early morning hours, having a pillion passenger, and when the motorcyclist is determined to be at fault for the accident. Factors leading to increased probability of vehicle damage include some similar factors but also show some differences, such as less damage associated with pedestrian collisions and with female drivers. In addition, it was also found that both injury severity and vehicle damage severity levels are decreasing over time. 相似文献
10.
Supported Pd/Sn bimetallic nanoparticles for reductive dechlorination of aqueous trichloroethylene 总被引:1,自引:0,他引:1
A Pd/Sn bimetallic nanoparticles resin (nano-Pd/Sn/resin) was successfully synthesized for reductive transformation of aqueous trichloroethylene (TCE). The physicochemical properties of the prepared resin were characterized using scanning electron microscopy, energy dispersive X-ray spectroscopy, N(2) isothermal sorption at and X-ray photospectroscopy. The surface-area-normalized rate constants (k(SA)) of Sn particles in the nanoscale range (50-100 nm) were 4.5 times larger than the k(SA) for powdered Sn (0.04 mm). After depositing 1 wt% Pd onto nano-Sn surface, k(SA) was further enhanced by about a factor of 2. Groundwater constituents such as sulfide nitrate and dissolved oxygen had significant negative effects on the rate of TCE degradation by the nano-Pd/Sn/resin. A wet-chemical method regeneration method was observed to effectively restore the reactivity of the poisoned nano-Pd/Sn/resin after dipping in sulfide solution for 2d. In all cases, less than 0.5% of the degraded TCE appeared as chlorinated byproducts including the three dichloroethene isomers. The nano-Pd/Sn/resin technique performs well in transforming TCE into nontoxic hydrocarbons, as compared with other published methods. 相似文献