首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   6篇
  免费   0篇
环保管理   3篇
污染及防治   3篇
  2013年   1篇
  2012年   1篇
  2011年   1篇
  2009年   2篇
  2006年   1篇
排序方式: 共有6条查询结果,搜索用时 0 毫秒
1
1.
Th anti-seizure medication carbamazepine is often found in treated sewage effluent and environmental samples. Carbamazepine has been shown to be very persistent in sewage treatment, as well as ground water. Due to environmental persistence, irrigation with sewage effluent could result in carbamazepine contamination of surface and ground water. To determine the potential for leaching of carbamazepine, a series of adsorption and desorption batch equilibrium experiments were conducted on irrigated soils. It was found that carbamazepine adsorption to biosolid-amended (T) soils had a KD of 19.8 vs. 12.6 for unamended soil. Based on adsorption, carbamazepine leaching potential would be categorized as low. During desorption significant hysteresis was observed and KD increased for both soils. Desorption isotherms also indicate a potential for irreversibly bound carbamazepine in the T soil. Results indicate that initial removal of carbamazepine via adsorption from irrigation water is significant and that desorption characteristics would further limit the mobility of carbamazepine through the soil profile indicating that carbamazepine found in sewage effluent used for irrigation has a low leaching potential.  相似文献   
2.
The quality of rural life can be affected by offensive odors released from animal buildings and storage units. The objectives of this study were to compare the concentrations of odor and odorants above different types of stirred swine slurry to analyze the relationships between concentrations of odor (and odorants) and physicochemical characteristics of the slurry (i.e. pH, temperature, dry matter, volatile solids, and concentration of 22 chemical compounds); and to propose predictive models for the odor concentration (OC) based on these physicochemical characteristics (solely and in combination with concentrations of specific odorants in the air above the slurries). The study comprised data on concentrations of odor and odorants in the air above slurry samples (fresh and/or stored) collected from production units with farrowing sows, finishing swines, or weaning pigs at eight swine operations (N = 48). OC measured in the air above stirred swine slurry samples were not significantly different among production types or storage times. The physicochemical characteristics of the slurries were not useful for predicting OC or concentrations of hydrogen sulfide (or organic sulfides) above the slurry, but were related to concentrations of other emitted gases such as phenols and indoles (r2 = 0.65–0.79, p <0.05), ammonia (r2 = 0.86, p < 0.05) and carboxylic acids (r2 = 0.23–0.59, p <0.05). There was good precision of predictive models of OC based on selected slurry characteristics (i.e. pH, dry matter, nitrogen content, sulfur content or concentrations of individual aromatic compounds and carboxylic acids) together with concentrations of specific odorants in the air (e.g. hydrogen sulfide) (r2 between 0.70 and 0.92). This study suggests that predictive models could be useful for evaluating odor nuisance potentials of swine slurry during handling.  相似文献   
3.
Odor from pig production facilities is typically measured with olfactometry, whereby odor samples are collected in sampling bags and assessed by human panelists within 30 h. In the present study, the storage stability of odorants in two types of sampling bags that are often used for olfactometry was investigated. The bags were made of Tedlar or Nalophan. In a field experiment, humid and dried air samples were collected from a pig production facility with growing-finishing pigs and analyzed with a gas chromatograph with an amperometric sulfur detector at 4, 8, 12, 28, 52, and 76 h after sampling. In a laboratory experiment, the bags were filled with a humid gas mixture containing carboxylic acids, phenols, indoles, and sulfur compounds and analyzed with proton-transfer-reaction mass spectrometry after 0, 4, 8, 12, and 24 h. The results demonstrated that the concentrations of carboxylic acids, phenols, and indoles decreased by 50 to >99% during the 24 h of storage in Tedlar and Nalophan bags. The concentration of hydrogen sulfide decreased by approximately 30% during the 24 h of storage in Nalophan bags, whereas in Tedlar bags the concentration of sulfur compounds decreased by <5%. In conclusion, the concentrations of odorants in air samples from pig production facilities significantly decrease during storage in Tedlar and Nalophan bags, and the composition changes toward a higher relative presence of sulfur compounds. This can result in underestimation of odor emissions from pig production facilities and of the effect of odor reduction technologies.  相似文献   
4.
Biological air filtration for reduction of emissions of volatile sulfur compounds (e.g., hydrogen sulfide, methanethiol and dimethyl sulfide) from livestock production facilities is challenged by poor partitioning of these compounds into the aqueous biofilm or filter trickling water. In this study, Henry’s law constants of reduced volatile sulfur compounds were measured for deionized water, biotrickling filter liquids (from the first and second stages of a two-stage biotrickling filter), and NaCl solutions by a dynamic method using Proton-Transfer-Reaction Mass Spectrometry (PTR-MS) at a temperature range of 3–45 °C. NaCl solutions were used to estimate salting-out constants up to an ionic strength of 0.7 M in order to evaluate the effect of ionic strength on partitioning between air and biofilter liquids. Thermodynamic parameters (enthalpy and entropy of phase exchange) were obtained from the measured partition coefficients as a function of temperature. The results show that the partition coefficients of organic sulfur compounds in the biotrickling filter liquids were generally very close to the corresponding partition coefficients in deionized water. Based on the estimated ionic strength of biofilter liquids, it is assessed that salting-out effects are of no importance for these compounds. For H2S, a higher enthalpy of air–liquid partitioning was observed for 2nd stage filter liquid, but not for 1st stage filter liquid. In general, the results show that co-solute effects for sulfur compounds can be neglected in numerical biofilter models and that the uptake of volatile sulfur compounds in biotrickling filter liquids cannot be increased by decreasing ionic strength.  相似文献   
5.
Odor emission from livestock production systems is a major nuisance in many rural areas. This study aimed at determining the major airborne chemical compounds responsible for the unpleasant odor perceived in swine facilities during slurry handling, and at proposing predictive models of odor concentration (OC) based on the concentrations of specific odorants in the air. A multivariate data analysis strategy involving principal components analysis and multiple linear regressions was implemented to analyze the relationships between concentration of 35 gases (measured by GC/MS or gas detection tubes), and the overall OC perceived by sensory analysis. The study compiled data on the concentration of odor and odorants, measured in the headspace of 24 unstored and stored slurry samples collected from three different types of production units on 8 commercial swine farms. Among all the measured constituents, OC was found to have the highest correlation with the sulfur containing compounds (i.e. hydrogen sulfide, dimethylsulfide, dimethyldisulfide, dimethyltrisulfide). The concentration of hydrogen sulfide accounted for 68% of the variation in OC above the stirred slurry samples. The highest concentrations of volatile organic compounds were observed for phenols and indoles, which made a significant contribution to the overall OC when the slurry was fresh. The contribution of ammonia to the OC was only significant in the absence of hydrogen sulfide. The precision of predictive models of OC based on the concentration of specific odorants in the air was satisfactory (R2 between 0.66 and 0.89). Hence, this study suggests that monitoring of specific odor compounds released from agitated swine slurry can be used to predict the concentration of odor perceived close to the source (e.g. at storage units), allowing the assessment of odor nuisance potentials.  相似文献   
6.
Prediction of odor from pig production based on chemical odorants   总被引:1,自引:0,他引:1  
The present work was performed to investigate the use of odorant measurements for prediction of odor concentration in facilities with growing-finishing pigs and to analyze the odorant composition in facilities with different floor and ventilation systems. Air was sampled in Nalophan bags, odor concentrations were measured by dilution-to-threshold olfactometry, and concentrations of odorants were measured by proton-transfer-reaction mass spectrometry (PTR-MS). Olfactometry and chemical analyses were synchronized to take place at identical time intervals after sampling. A principal component analysis revealed that different facilities for growing-finishing pigs can be distinguished based on the odorants. Pit ventilation comprising a small amount of the total ventilation air (10-20%) in facilities with both room and pit ventilation can be used to concentrate odorants, whereas the room ventilation contains lower concentrations of most odorants. A partial least squares regression model demonstrated that prediction of the odor concentration based on odorants measured by PTR-MS is feasible. Hydrogen sulfide, methanethiol, trimethylamine, and 4-methylphenol were identified as the compounds having the largest influence on the prediction of odor concentration, whereas carboxylic acids had no significant influence. In conclusion, chemical measurement of odorants by PTR-MS is an alternative for expressing the odor concentration in facilities with growing-finishing pigs that can be used to increase the understanding of odor from different types of facilities and improve the development of odor reduction technologies.  相似文献   
1