首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   18篇
  免费   0篇
安全科学   1篇
环保管理   2篇
基础理论   2篇
污染及防治   12篇
社会与环境   1篇
  2013年   1篇
  2010年   1篇
  2008年   1篇
  2007年   3篇
  2006年   2篇
  2005年   2篇
  2004年   4篇
  1995年   2篇
  1991年   2篇
排序方式: 共有18条查询结果,搜索用时 31 毫秒
1.
A four-stage method of providing conditions for improving the stability of a landscape sector is presented. In the first stage, structure and function of the landscape system is examined, predominantly based on the results of monitoring. In the second stage, a method is suggested for applying monitoring data to a dynamic structure with complex functions of the territory under examination. In the third stage, the territory is optimized as to the function of particular components within it. The optimization consists in controlling the dynamics of the flows of material, energy, and population within the sector. In the fourth stage, the holistic function of the landscape strip should be monitored with respect to representative key factors. The entire concept is based on assuming the existence of destabilizing processes leading to ecocritical situations and determining mitigating factors using heuristic methods of optimization.  相似文献   
2.
To obtain robust data on the toxicity of LAS, tests with the collembolan Folsomia candida L., the oligochaetes Aporrectodea caliginosa Savigny (earthworm) and Enchytraeus crypticus Westheide and Graefe (enchytraeid) were performed in a sandy loam soil. Additionally limited tests with LAS spiked to sewage sludge, and subsequently mixed into soil, were performed. For the endpoint of interest, reproduction in soil, we found an EC10 of 205 mg LAS kg(-1) soil [8.6-401] [95% confidence limits] for F. candida and an EC10 of 46 mg LAS kg(-1) soil [13-80] for A. caliginosa after 28 days. E. crypticus was not affected by concentrations up to 120 mg LAS kg(-1) soil. When adding (low contaminated) non-spiked sludge to soil, high stimulation of reproduction was observed for E. crypticus and A. caliginosa but not for F. candida. We argue that this difference in stimulative response between the tested species is related to the difference in feeding behaviour. Sludge spiked with LAS did not significantly affect the reproduction of F. candida (fertility: number of juvenile offspring) and A. caliginosa (fecundity: number of cocoons) (dose equivalent to 181 g and 91 g LAS kg(-1) sludge, respectively). Significantly reduced reproduction was observed for E. crypticus (at 120 mg LAS kg(-1) soil+sludge corresponding to 72 g LAS kg(-1) sludge) compared to non-spiked sludge. The reproduction by E. crypticus was, however, comparable to the reproduction observed in the control soil without sludge. Compared to LAS directly spiked to soil, the reproductive output of organisms exposed to spiked sludge was either not significantly different (F. candida, E. crypticus) or significantly improved (A. caliginosa). More studies are needed in order to make firm conclusions on the potential effect of artificially contaminated sludge in soil systems.  相似文献   
3.
The method of anthropoecological landscape stability (AELS) has been applied experimentally to a territorial unit, forming a closed watershed with more of less precisely defined material, energy, and population flows. This article presents data-driven results of monitoring and conclusions on optimizing features derived from two object-oriented expert systems—the FORELIS, giving heuristically optimal conditions for forest compositions on the site in the prevailing immission situation, and AGRILIS—the agricultural expert system having the scope of finding suitable forms of agriculture with respect to natural conditions and suitable actual production facilities. The results of the study fully confirmed the feasibility of applying expert systems to actual conditions, and no significant errors in the results of the expert systems compared to indications by monitoring have been disclosed.  相似文献   
4.
The process of electrochemical treatment of a solution after strong basic anion exchanger regeneration was studied. The goal of the study was to reduce the nitrate content in the solution to allow its use in a closed loop. Diaphragmless, flow-through cells in a recirculation mode with and without a fluidizing bed of inert particles in the interelectrode space equipped with copper (Cu) cathodes and activated titanium anodes were used. The temperature was maintained at 20 degrees C. To assess the influence of recirculation of the regenerant solution on the quality of the treated water, the effect of the addition of copper ions to the solution, postelectrolysis cathode treatment, and enhanced mass transfer on the electrolysis results with respect to current efficiency and residual nitrate and nitrite concentration were investigated using an artificial solution. On the basis of the experimental results, a laboratory-scale unit for selective nitrate removal was designed and constructed that integrated ion exchange and electrochemical cell to one assembly. The process of recirculation of regenerant solution was tested using groundwater.  相似文献   
5.
The process of selective nitrate removal from drinking water by means of ion exchange was studied. A commercial strong base anion exchanger with triethylammonium (-N+Et3) functional groups was used in the bicarbonate (HCO3-) and carbonate (CO3(2-)) form. The aim of this study was to optimize ion-exchanger regeneration in view of the subsequent electrochemical reduction of nitrates in the spent regenerant solution. The effects of ion-exchanger form, concentration of regenerant solution, and presence of nitrates, chlorides, and sulphates in the regenerant solution were studied. The strong base anion exchanger in HCO3- form that was investigated was able to treat 270 bed volumes of model water solution containing 124 mg dm(-3) nitrates. To achieve adequate regeneration of the saturated anion exchanger, it is necessary to use approximately 30 bed volumes of fresh 1-M sodium bicarbonate (NaHCO3) regenerant solution. The presence of residual 50-mg dm(-3) nitrates in the regenerant solution, treated by electrolysis, resulted in an increase in the dose of regenerant solution to 35 bed volumes and a decrease in the subsequent sorption run of approximately 13%. The volume of applied regenerant solution was high, but the consumption of NaHCO3 for regeneration was low.  相似文献   
6.
Microbial degradation of two diastereoisomeric forms 2 and 3 of a selected juvenoid (insect juvenile hormone bioanalog), ethyl N-{2-{4-[(2-hydroxycyclohexyl)methyl]phenoxy}ethyl}carbamate was studied and the degradation products analyzed. Degradation experiments were performed using simple modeling under laboratory conditions. A Candida sp. strain T1, isolated from soil, was chosen as a biodegradation species. Radiolabeling of the studied compounds 2 and 3 was used in combination with radio-HPLC and MS analysis to increase the limits of detection, monitoring and isolation of trace quantities of the products of degradation and/or transformation. Resulting from the microbial processes using 2 or 3 as source compounds, three identical products (4-6) of their biodegradation were produced. Compound 2 also afforded two additional products (7, 8). Radio-HPLC analysis and separation, and subsequent MS analysis of the degradation mixtures resulted in identification of the degradation products. The degree and the rate of biodegradation of 2 and 3 were analyzed after 1, 3 and 7 days from the beginning of the experiment.  相似文献   
7.
The samples of soils, earthworms and vegetation (needles, lichens, mosses) were collected for the realization of Project TOCOEN (Toxic Organic Compounds in the ENvironment). The samples were collected from three TOCOEN model areas in Czechoslovakia—one city and two rural areas. The samples were analyzed for polycyclic aromatic hydrocarbons (PAHs), chlorinated pesticides (C1‐PEST) and polychlorinated biphenyls (PCBs).  相似文献   
8.
Reth M  Zencak Z  Oehme M 《Chemosphere》2005,58(7):847-854
This study presents the first investigation of concentrations and congener group patterns of short- (SCCPs) and medium-chain chlorinated paraffins (MCCPs) in fish from the North and Baltic Sea. North Sea dab, cod and flounder were studied. High resolution gas chromatography (HRGC) coupled to low resolution mass spectrometry (LRMS) in the electron capture negative ionization mode (ECNI) was employed. Good linearity (R2>0.993, 7 measuring points) was achieved between 1 and 100 ng/g of CP mixtures for SCCPs and MCCPs. The limits of detection were 0.5-1 ng/microl of CP mixture for the major congener groups of SCCPs and MCCPs. A clean-up comprising fat extraction, adsorption chromatography on silicagel impregnated with concentrated sulphuric acid and adsorption chromatography on Florisil was employed to avoid interferences from other polychlorinated compounds. Recoveries of CPs in spiked samples ranged between 80% and 100%. Accuracy was controlled with spiked samples and deviated not more than 10% from the expected values. Quantification was performed with standards of an average chlorine content as close as possible to that of the samples (SCCPs: 59-62%, MCCPs: 53-58%). SCCP concentrations ranged between 19 and 286 ng/g liver wet weight (ww), MCCP concentrations were comparable with a range of 25-260 ng/gww. Congener group patterns were also determined and discussed. In samples from the Baltic Sea the SCCP congener pattern was similar to that of commercial SCCP mixtures or C13 congeners were most abundant. In samples from the North Sea a higher relative abundance of C10 congeners was observed.  相似文献   
9.
Borovicka J  Randa Z  Jelínek E 《Chemosphere》2006,64(11):1837-1844
Species of macrofungi (mushrooms) were collected from clean areas and analyzed for their antimony content. These were compared to species collected from extremely polluted areas in the vicinity of a lead smelter and on mine and slag dumps. Antimony content was determined using long-term instrumental neutron activation analysis (INAA). Ectomycorrhizal and terrestrial saprobic macrofungi were examined. Antimony content of macrofungi from the clean areas was mostly less than 100 μg kg−1 (dry mass). The highest concentrations (units of mg kg−1) were found in various species of the ectomycorrhizal genera Chalciporus and Suillus. Antimony contents of macrofungi growing in the polluted areas were considerably higher. The highest content was found in a single collection of Chalciporus piperatus (1423 mg kg−1).  相似文献   
10.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号