首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   6篇
  免费   0篇
环保管理   1篇
污染及防治   5篇
  2020年   1篇
  2018年   1篇
  2014年   1篇
  2007年   1篇
  2005年   1篇
  2003年   1篇
排序方式: 共有6条查询结果,搜索用时 15 毫秒
1
1.
Battery tests serve as integral tools to decide whether a treatment process is ecotoxicologically safe or not. In the present study, a battery of toxicity tests was employed to elucidate the toxicity of the potential endocrine-disrupting pollutant bisphenol A (BPA) and its advanced oxidation products. For this purpose, BPA was subjected to Fenton treatment in the growth medium of the test organisms employed as well as in real lake water. Treatment results indicated that BPA removals were fast and complete within less than a minute, whereas total organic carbon (TOC) removals were rather incomplete, speaking for the accumulation of refractory degradation products. The presence of chloride and/or natural organic matter influenced H2O2 consumption rates and the treatment performance of the Fenton’s reagent as well. The sensitivity of the selected test organisms for BPA and its Fenton treatment products in different water matrices was found in the following decreasing order: the freshwater microalgae (Pseudokirchneriella subcapitata) > the freshwater cladoceran (Daphnia magna) > marine photobacteria (Vibrio fischeri).  相似文献   
2.

Recently, the European Food Safety Authority (EFSA) has banned the use of iprodione (IPR), a common hydantoin fungicide and nematicide that was frequently used for the protective treatment of crops and vegetables. In the present study, the treatment of 2 mg/L (6.06 μM) aqueous IPR solution through ultraviolet-C (UV-C)-activated persulfate (PS) advanced oxidation process (UV-C/PS) was investigated. Baseline experiments conducted in distilled water (DW) indicated that complete IPR removal was achieved in 20 min with UV-C/PS treatment at an initial PS concentration of 0.03 mM at pH?=?6.2. IPR degradation was accompanied with rapid dechlorination (followed as Cl? release) and PS consumption. UV-C/PS treatment was also effective in IPR mineralization; 78% dissolved organic carbon (DOC) was removed after 120-min UV-C/PS treatment (PS?=?0.30 mM) compared with UV-C at 0.5 W/L photolysis where no DOC removal occurred. LC analysis confirmed the formation of dichloroaniline, hydroquinone, and acetic and formic acids as the major aromatic and aliphatic degradation products of IPR during UV-C/PS treatment whereas only dichloroaniline was observed for UV-C photolysis under the same reaction conditions. IPR was also subjected to UV-C/PS treatment in simulated tertiary treated urban wastewater (SWW) to examine its oxidation performance and ecotoxicological behavior in a more complex aquatic environment. In SWW, IPR and DOC removal rates were inhibited and PS consumption rates decreased. The originally low acute toxicity (9% relative inhibition towards the photobacterium Vibrio fischeri) decreased to practically non-detectable levels (4%) during UV-C/PS treatment of IPR in SWW.

  相似文献   
3.
Pre-ozonation of 14 different reactive dyestuff hydrolysates at alkaline pH was investigated to assess possible relationships between ozone transfer efficiency, first order decolourization kinetics, release of initially complexed heavy metals and relative changes in the biodegradability of the partially oxidized dye waste samples. Biocompatibility of the raw (untreated) and ozonated dye hydrolysates was comparatively tracked through specific oxygen uptake rate measurements from which the respirometric inhibition of biological activated sludge imparted by raw and ozonated reactive dye wastewater with respect to synthetic domestic wastewater was determined. It could be demonstrated that preliminary ozonation of reactive azo dyes increases their biological compatibility more significantly than formazan copper complex, copper complex azo and phythalocyanine dyes as a consequence of heavy metal release associated with the cleavage of associated chromophoric groupings right at the initial stages of pre-ozonation.  相似文献   
4.
The effect of varying inorganic (chloride, nitrate, sulfate, and phosphate) and organic (represented by humic acid) solutes on the removal of aqueous micropollutant bisphenol A (BPA; 8.8 μM; 2 mg/L) with the oxidizing agents hydrogen peroxide (HP; 0.25 mM) and persulfate (PS; 0.25 mM) activated using zero-valent aluminum (ZVA) nanoparticles (1 g/L) was investigated at a pH of 3. In the absence of the solutes, the PS/ZVA treatment system was superior to the HP/ZVA system in terms of BPA removal rates and kinetics. Further, the HP/ZVA process was not affected by nitrate (50 mg/L) addition, whereas chloride (250 mg/L) exhibited no effect on the PS/ZVA process. The negative effect of inorganic anions on BPA removal generally speaking increased with increasing charge in the following order: NO3? (no inhibition)?<?Cl? (250 mg/L)?=?SO42??<?PO43? for HP/ZVA and Cl? (250 mg/L; no inhibition)?<?NO3??<?SO42??<?PO43? for PS/ZVA. Upon addition of 20 mg/L humic acid representing natural organic matter, BPA removals decreased from 72 and 100% in the absence of solutes to 24 and 57% for HP/ZVA and PS/ZVA treatments, respectively. The solute mixture containing all inorganic and organic solutes together partly suppressed the inhibitory effects of phosphate and humic acid on BPA removals decreasing to 46 and 43% after HP/ZVA and PS/ZVA treatments, respectively. Dissolved organic carbon removals were obtained in the range of 30 and 47% (the HP/ZVA process), as well as 47 and 57% (the PS/ZVA process) for the experiments in the presence of 20 mg/L humic acid and solute mixture, respectively. The relative Vibrio fischeri photoluminescence inhibition decreased particularly for the PS/ZVA treatment system, which exhibited a higher treatment performance than the HP/ZVA treatment system.  相似文献   
5.
The occurrence of significant amounts of biocidal finishing agents in the environment as a consequence of intensive textile finishing activities has become a subject of major public health concern and scientific interest only recently. In the present study, the treatment efficiency of selected, well-known advanced oxidation processes (Fenton, Photo-Fenton, TiO(2)/UV-A, TiO(2)/UV-A/H(2)O(2)) and ozone was compared for the degradation and detoxification of a commercial textile biocide formulation containing a 2,4,4'-trichloro-2'-hydroxydiphenyl ether as the active ingredient. The aqueous biocide solution was prepared to mimic typical effluent originating from the antimicrobial finishing operation (BOD(5,o) < or =5 mg/L; COD(o)=200 mg/L; DOC(o) (dissolved organic carbon)=58 mg/L; AOX(o) (adsorbable organic halogens)=48 mg/L; LC(50,o) (lethal concentration causing 50% death or immobilization in Daphnia magna)=8% v/v). Ozonation experiments were conducted at different ozone doses (500-900 mg/h) and initial pH (7-12) to assess the effect of ozonation on degradation (COD, DOC removal), dearomatization (UV(280) and UV(254) abatement), dechlorination (AOX removal) and detoxification (changes in LC(50)). For the Fenton experiments, the effect of varying ferrous iron catalyst concentrations and UV-A light irradiation (the Photo-Fenton process) was examined. In the heterogenous photocatalytic experiments, Degussa P25-type TiO(2) was used as the catalyst and the effect of reaction pH (3, 7 and 12) and H(2)O(2) addition on the photocatalytic treatment efficiency was examined. Although in the photochemical (i.e. Photo-Fenton, TiO(2)/UV-A and TiO(2)/UV-A/H(2)O(2)) experiments appreciably higher COD and DOC removal efficiencies were obtained, ozonation appeared to be equally effective to achieve dearomatization (UV(280) abatement) at all studied reaction pH. During ozonation of the textile biocide effluent, AOX abatement proceeded significantly faster than dearomatization and was complete after 20 min ozonation (267 mg O(3)). On the other hand, for complete detoxification, ozonation had to be continued for at least 30 min (corresponding to 400mg O(3)). Effective AOX and acute toxicity removal was also obtained after heterogeneous photocatalytic treatment (TiO(2)/UV-A and TiO(2)/UV-A/H(2)O(2)). The Fenton-based treatment experiments and particularly the dark Fenton reaction resulted in relatively poor degradation, dearomatization, AOX and acute toxicity removals.  相似文献   
6.
Ozonation characteristics of synthetic Procaine Penicillin G (PPG) formulation effluent were investigated in a semi-batch ozone reactor at different pH (3, 7 and 12), ozone feed rates (600-2600 mg h-1) and COD values (200-600 mg l-1). Ozonation of aqueous PPG effluent resulted in 37 (82)% COD removal after 60 (120) min ozonation when the reaction pH was kept constant at pH=7.900 mg l-1 (corresponding to 50% of the total introduced) ozone was absorbed during a reaction period of 1 h. The effects of increasing the applied ozone dose and the initial COD on the COD abatement rates of PPG effluent were also studied. Results have indicated that increasing the ozone dose and decreasing the COD content both have positive effects on COD removal rates. The significant contribution of the free radical (.OH) reaction pathway to PPG ozonation could be traced using tert-butyl alcohol as the .OH probe compound at varying concentrations. The bimolecular reaction rate constants for the direct reaction of PPG with ozone were found as 152 and 2404 M-1 h-1 at pH=3 and 7, respectively, using the gas phase ozone partial pressures determined from of the outlet gas stream analysis. It could be demonstrated that ozone decomposition to free radicals being triggered by increasing the pH from 3 to 7 is essential for the rate enhancement of PPG effluent ozonation.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号