首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   7篇
  免费   0篇
污染及防治   5篇
评价与监测   2篇
  2016年   1篇
  2014年   1篇
  2011年   1篇
  2010年   1篇
  2008年   1篇
  2007年   1篇
  2005年   1篇
排序方式: 共有7条查询结果,搜索用时 656 毫秒
1
1.
Air concentrations of polychlorinated biphenyls (PCBs) in both gas and particle phases were measured in an urban site (BUTAL-Merinos) of the city of Bursa, Turkey between August 2004 and May 2005. The mean of total (particle+gas) PCB concentrations was about 491.8+/-189.4pg/m(3). The main contributors for PCBs in the sampling site were the local sources and long-range atmospheric transport supported by back trajectory analysis. Lower molecular weight PCB congeners generally dominated in the samples. The particle phase of the measured PCBs accounted for 15% of the total PCB concentrations. Gas/particle distribution was investigated using different approaches such as log K(P)-log P(L)(o), log K(P)-log K(OA) and the Junge-Pankow model. Regression analysis among log K(P), log P(L)(o) and log K(OA) exhibited significant correlation at p<0.05. Correlation between PCB homologs and meteorological parameters was formed to investigate the possible relationships.  相似文献   
2.
Air samples were collected at a residential site (Gulbahce, Bursa, Turkey) between August 2004 and April 2005 using a modified high volume air sampler. The mean of gas and particle phase concentrations of polychlorinated biphenyls (PCBs) were 468 ± 297 and 43 ± 37 pg m???3 (average ± standard deviation, SD), respectively. The dominated PCB homologs were 3-CBs, 4-CBs, and 5-CBs. The measured PCB concentrations were higher than the values of pristine sites. In order to assess the gas/particle partitioning fate, log K P–log $P_{\rm L}^o$ , log K P–log K OA and the Junge–Pankow model were applied to the data. Experimental K P was well correlated with $\log P_{\rm L}^o$ and log K OA at p?<?0.05. Then, dry deposition fluxes were estimated using atmospheric concentrations and dry deposition velocities obtained from literature. A correlation matrix was formed for PCB homologs including 27 congeners with concurrently measured 16 polycyclic aromatic hydrocarbons (PAHs) and meteorological parameters. Most of PAH compounds were significantly correlated with 5-CBs and 6-CBs.  相似文献   
3.
Ambient air and deposition samples were collected in the period of July 2004-May 2005 in an industrial district of Bursa, Turkey and analyzed for polycyclic aromatic hydrocarbon (PAH) compounds. The overall average of fourteen bulk deposition fluxes for PAHs was 3300+/-5100 ng m(-2) d(-1). PAH depositions showed a seasonal variation and they were higher in winter months. This was probably due to increases in residential heating activities and decreases in atmospheric mixing layer levels. Ambient air samples, measured with a high volume air sampler, were collected from the same site. The average total concentration including gas and particulate phase was about 300+/-420 ng m(-3) and it was in the range of previously reported values. Some of the ambient air and bulk deposition samples were collected simultaneously in dry periods. Both concurrently measured values were used to calculate the dry deposition velocities whose overall average value was 0.45+/-0.35 cm s(-1).  相似文献   
4.
In the present study, the amounts of polycylic aromatic hydrocarbons (PAHs) penetrating into air during PAH removal applications from the urban treatment sludge were investigated. The effects of the temperature, photocatalyst type, and dose on the PAH removal efficiencies and PAH evaporation were explained. The sludge samples were taken from an urban wastewater treatment plant located in the city of Bursa, with 585,000 equivalent population. The ultraviolet C (UV-C) light of 254 nm wavelength was used within the UV applications performed on a specially designed setup. Internal air of the setup was vacuumed through polyurethane foam (PUF) columns in order to collect the evaporated PAHs from the sludge during the PAH removal applications. All experiments were performed with three repetitions. The PAH concentrations were measured by gas chromatography–mass spectrometry (GC-MS). It was observed that the amounts of PAHs penetrating into the air were increased with increase of temperature, and more than 80% of PAHs migrated to the air consisted of 3-ring compounds during the UV and UV-diethylamine (DEA) experiments at 38 and 53 °C. It was determined that 40% decrease was ensured in Σ12 (total of 12) PAH amounts with UV application and 13% of PAHs in sludge penetrated into the air. In the UV-TiO2 applications, a maximum 80% of Σ12 PAH removal was obtained by adding 0.5% TiO2 of dry weight of sludge. The quantity of PAH penetrating into air did not exceed 15%. UV-TiO2 applications ensured high levels of PAH removal in the sludge and also reduced the quantity of PAH penetrating into the air. Within the scope of the samples added with DEA, there was no increase in PAH removal efficiencies and the penetration of PAHs into air was not decreased. In light of these data, it was concluded that UV-TiO2 application is the most suitable PAH removal alternative that restricts the convection of PAH pollution.
Implications: Polycyclic aromatic hydrocarbon (PAH) evaporation rates from sludge samples obtained from an urban wastewater treatment plant were investigated here for the first time by employing removal applications. TiO2 and diethylamine were used as photocatalysts in this study. A special device was designed and successfully used in this study. Treatment sludge can be a significant source of PAHs for the atmosphere. The data highlight the need for removal of PAHs in treatment sludge via methods limiting their evaporation to the air. It was observed that UV-TiO2 application was the most suitable PAH removal alternative that restricts the convection of PAH pollution.  相似文献   
5.
Wet deposition fluxes of organochlorine pesticides (OCPs) were determined for rain samples collected in a coastal area of Turkey. Seventeen precipitation samples were collected over a 1-year period from 2008 to 2009. Rainwater was accumulated at the beginning of rain events using real time monitoring. Atmospheric concentrations were also measured in parallel with deposition samples. Both atmospheric concentrations and deposition fluxes were determined as particle and gas phases. The particle phase and dissolved phase deposition fluxes were 794.26?±?756.70 ngm?2 day?1 and 800.77?±?672.63 ngm?2 day?1, respectively. The washout ratios for OCP compounds were calculated separately for the particle and dissolved phases using the atmospheric concentrations and rain concentrations. The minimum washout ratio for the particle phase was 2339.47 for Endrin aldehyde, whereas the maximum washout ratio was 497593.34 for Methoxychlor. The maximum washout ratio for the dissolved phase was 247523.89 for Endosulfan beta, whereas the minimum washout ratio was 10169.69 for p,p′-DDT. The dry deposition velocities ranged from 0.01 to 1.67 cms?1. The partitioning of wet deposition between the particle and dissolved phases was 50 % in terms of total OCP deposition.  相似文献   
6.
Cindoruk SS 《Chemosphere》2011,82(1):78-87
Air concentrations of organochlorine pesticides (OCPs) were measured at four different sites in Bursa, Turkey to determine current levels. For this purpose, about 35 samples were collected from June 2008 to June 2009 using a high volume air sampler (HVAS) equipped with particle and gas-phase units. Ten OCP compounds (alpha-, beta-, gamma-, delta-hexachlorocyclohexane, Heptachlor epoxide, Endrin, Endosulfan beta, Endrin aldehyde, p,p′-DDT and Methoxychlor) were reported within the scope of this study. The average concentrations of total (particle + gas) ∑OCPs were 550.9 ± 277.6 pg m−3 (coastal), 1030.7 ± 453.5 pg m−3 (urban/traffic), 519.7 ± 277.5 pg m−3 (semi-rural) and 722.8 ± 351.8 pg m−3 (urban/residential). The individual OCP concentrations were in line with reported concentrations. The maximum particle and gas-phase concentrations were determined for Endosulfan beta and beta-HCH for all sites, respectively. Available gas/particle partitioning models were applied in order to investigate the compatibility of the experimental data and the significant relationships were observed.  相似文献   
7.
The concentrations of criteria air pollutants such as CO, NOx (NO + NO2), SO2 and PM were measured in the period of May 2001 and April 2003 in the city of Bursa, Turkey. The average concentrations for this period were 1115±1600 μg/m3, 29±50 μg/m3, 51±24 μg/m3, 79±65 μg/m3, 40±35 μg/m3, 98±220 μg/m3, for CO, NO, NO2, NOx, SO2 and PM, respectively. Temporal changes in concentrations were analyzed using meteorological factors. Correlations among pollutant concentrations and meteorological parameters showed weak relations nearly in all data. Lower concentrations were observed in the summer months while higher concentrations were measured in the winter months. The increase in winter concentrations was probably due to residential heating. Pollutants were associated with each other in order to have information about their origin. NOx/SO2 ratio was also examined to bring out the source origin contributing on air pollution (i.e., traffic or stationary).  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号