首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   6篇
  免费   0篇
基础理论   1篇
污染及防治   5篇
  2013年   2篇
  2010年   1篇
  2007年   1篇
  2004年   1篇
  1992年   1篇
排序方式: 共有6条查询结果,搜索用时 819 毫秒
1
1.
A rapid Biacore biosensor immunoassay of 4-nonylphenols was developed. Two types of antibodies were used in the study: polyclonal antibodies with high cross-reactivity towards technical 4-nonylphenol and a monoclonal antibody very specific to 4-n-nonylphenol. 9-(p-Hydroxyphenyl)nonanoic acid was immobilized onto surface of a sensor chip. The best assay sensitivity was achieved using a flow rate of 50 microl min(-1) and injection time of 2 min. For the assay incorporating monoclonal antibodies a limit of detection 2 ng ml(-1) for 4-n-nonylphenol was achieved. With polyclonal antibodies one order lower sensitivity was observed for 4-nonylphenols. High background level of calibration curve for technical 4-nonylphenol was decreased by using IgG fraction of polyclonal antibodies in combination with lower amount of immobilised 9-(p-hydroxyphenyl)nonanoic acid. Sensitivity of the assay was improved by using a chip with a new derivative on a surface-N-aminobutyl [2-(4-hydroxyphenyl)ethylamine] (limit of detection--5 ng ml(-1)). Applicability of the developed assays to ecological monitoring was checked in experiments using shellfish samples. 4-n-Nonylphenol from spiked samples was extracted into hexane followed by clean-up on NH2 SPE columns. Calibration curves generated for cockles, mussels and oyster samples were identical (limit of detection about 10 ng g(-1)) whereas for scallop samples a slight decrease (about 5-10%) of absolute response was observed. In the assay using the monoclonal antibody specific to 4-n-nonylphenol 31 shellfish samples were found to be negative. Results obtained with polyclonal antibodies indicated that two scallop samples contained a quantity of 4-nonylphenols. The developed biosensor assay could be applied for shellfish analysis as a preliminary screening method.  相似文献   
2.
Abstract: Species occurrence in a habitat patch depends on local habitat and the amount of that habitat in the wider landscape. We used predictions from empirical landscape studies to set quantitative conservation criteria and targets in a multispecies and multiscale conservation planning effort. We used regression analyses to compare species richness and occurrence of five red‐listed lichens on 50 ancient oaks (Quercus robur; 120–140 cm in diameter) with the density of ancient oaks in circles of varying radius from each individual oak. Species richness and the occurrence of three of the five species were best explained by increasing density of oaks within 0.5 km; one species was best explained by the density of oaks within 2 km, and another was best predicted by the density of oaks within 5 km. The minimum numbers of ancient oaks required for “successful conservation” was defined as the number of oaks required to obtain a predicted local occurrence of 50% for all species included or a predicted local occurrence of 80% for all species included. These numbers of oaks were calculated for two relevant landscape scales (1 km2 and 13 km2) that corresponded to various species responses, in such a way that calculations also accounted for local number of oaks. Ten and seven of the 50 ancient oaks surveyed were situated in landscapes that already fulfilled criteria for successful conservation when the 50% and 80% criteria, respectively, were used to define the level of successful conservation. For cost‐efficient conservation, oak stands in the landscapes most suitable for successful conservation should be prioritized for conservation and management (e.g., grazing and planting of new oaks) at the expense of oak stands situated elsewhere.  相似文献   
3.
Visual Determination of the Opacity of Emissions from Stationary Sources (Method 9) is a reference method established by U.S. Environmental Protection Agency (EPA) to quantify plume opacity. However, Method 9 relies on observations from humans, which introduces subjectivity. In addition, it is expensive to teach and certify personnel to evaluate plume opacity on a semiannual basis. In this study, field tests were completed during a "smoke school" and a 4-month monitoring program of plumes emitted from stationary sources with a Method 9 qualified observer to evaluate the use of digital photography and two computer algorithms as an alternative to Method 9. This Digital Optical Method (DOM) improves objectivity, costs less to implement than Method 9, and provides archival photographic records of the plumes. Results from "smoke school" tests indicate that DOM passed six of eight tests when the sun was located in the 140 degrees sector behind one of the three cameras, with the individual opacity errors of 15% or less and average opacity errors of 7.5% or less. DOM also passed seven of the eight tests when the sun was located in the 216 degrees sector behind another camera. However, DOM passed only one of the eight tests when the sun was located in the 116 degrees sector in front of the third camera. Certification to read plume opacity by a "smoke reader" for 6 months requires that the "smoke reader" pass one of the smoke school tests during smoke school. The average opacity errors and percentage of observations with individual opacity errors above 15% for the results obtained with DOM were lower than those obtained by the smoke school trainees with the sun was located behind the camera, whereas they were higher than the smoke school trainee results with the sun located in front of the camera. In addition, the difference between plume opacity values obtained by DOM and a Method 9 qualified observer, as measured in the field for two industrial sources, were 2.2%. These encouraging results demonstrate that DOM is able to meet Method 9 requirements under a wide variety of field conditions and, therefore, has potential to be used as an alternative to Method 9.  相似文献   
4.
Economic studies of proposed environmental regulations begin with estimates of compliance actions and their costs. The assumptions about compliance actions can be misleading. In economic studies pertaining to regulations for volatile organic compound emissions by Illinois paper coaters, three sources of shortcomings are particularly evident: 1) failure to appreciate linkages between regulations applying to closely allied industries; 2) emphasis on well-known technologies, despite strong evidence that they will be displaced; and 3) heavy reliance on EPA technical data, whether or not they fairly represent state or local conditions.  相似文献   
5.
The level of mercury exposure in Slovenian dental practice was studied by measurement of air mercury levels in 63 surgeries and by analysis of the mercury content in blood and urine samples of professionally exposed and control groups (total of 77 participants).

The mean ambiental mercury concentration for all investigated surgeries was 2.8 ug Hg/m3 (range: 0.4–8.2), which is considerably below the health-based occupational exposure limit of 25 ug/m3. No significant relationships between age or type of surgeries, or the time during the working day and the air mercury levels were found.

The mean value for mercury in blood was 3.0 ng Hg/g (range: 0.9–7.7), which can be considered as the normal range for the general population. The occupational profile of the workers, years in the profession, as well as sex, showed a nonsignificant effect on blood mercury.

Urinary mercury levels were also low. Only 3 of 44 values exceeded 15 ng Hg/g. No influence of sex or occupational profile was found; however, a significant negative linear relationship (r=−0.473; P=0.0012) was observed between the concentration of mercury in urine and years in the profession.

The data indicate good mercury hygiene in Slovenian dentistry.  相似文献   

6.
This paper documents the variation in pressure drop and collection efficiency for fiberglass/fly ash fabric filter systems caused by variations in cleaning intensity (reverse air and reverse pulse), air to cloth ratio, and dust loading. Reverse air rates greater than 2 fpm were required to produce stable pressure characteristics. Pulse jet pressure greater than 50 psi reduced collection efficiency. Increased air to cloth ratios produced decreased collection efficiency.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号