首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   8篇
  免费   0篇
废物处理   1篇
基础理论   1篇
污染及防治   5篇
评价与监测   1篇
  2021年   1篇
  2015年   1篇
  2011年   1篇
  2009年   1篇
  2007年   1篇
  2003年   1篇
  2002年   1篇
  2000年   1篇
排序方式: 共有8条查询结果,搜索用时 15 毫秒
1
1.
Tracer gas was released upwind of a two-compartment complex shaped building under unstable atmospheric conditions. The mean wind direction was normal to or at 45° to the long face of the building. The general patterns of concentration distribution on the building external walls and inside the building were analysed and the influence of natural and mechanical ventilation on indoor concentration distributions was discussed. Mean concentration levels, as well as the concentration fluctuation intensity, were higher on the windward walls of the building, although concentration levels varied along each wall. Concentration fluctuations measured inside the building were lower than those measured outside. Inside the two compartments of the building, the time series of concentrations had a similar general behaviour; however, gas concentrations took approximately 1.5 times longer to reach the mean maximum concentration value at the downwind compartment 02 while they also decreased more rapidly in the upwind compartment 01 after the source was turned off. The highest indoor concentration and concentration fluctuation values were observed at the detectors located close to the windward walls, especially when the building windows were open. Experiments with and without natural ventilation suggested that infiltration and exfiltration of contaminants is much faster when the building windows are open, resulting to higher indoor concentration levels. Furthermore, mechanical ventilation tends to homogenize concentrations and suppress concentration fluctuations, leading to lower maximum concentration values.  相似文献   
2.
Field experiments were carried out in the vicinity of anisolated building using open-path and point monitoring airpollution detectors to measure concentrations of a tracer gasreleased from a source located either on the building or at thedownwind face of the building. Experiments were conducted underneutral or slightly unstable weather conditions. Either threeor five fast-response point monitors were located along thebeam path of an open-path instrument, in the wake of thebuilding. Experiments were performed with different sourcelocations, detector locations and building orientations to thewind. Visual comparison of data time series showed that datafrom the two types of instruments followed similar trends. Thebest degree of correlation occurred for an averaging timesimilar to the response time of the open-path monitor. Meanconcentrations detected by the open-path instrument weregenerally in very good agreement with the path averaged meanconcentrations from the point monitors. The point monitors werealso capable of providing time-resolved data needed to describedetailed concentration fluctuation statistics.  相似文献   
3.
The aim of this work is to investigate atmospheric flow and dispersion of contaminants in the vicinity of single buildings under different stability conditions. The mathematical model used is based on the solution of equations of conservation of mass, linear momentum and energy with the use of a non-standard κ? turbulence model. The modifications proposed in the κ? model are the inclusion of the Kato and Launder correction in the production of turbulent kinetic energy and the use of a modified wall function. Results are presented of numerical simulations of dispersion around a cubical obstacle, under neutral, stable and unstable atmospheric conditions. Experimental data from wind tunnel and field trials obtained by previous authors are used to validate the numerical results. The numerical simulation results show a reasonable level of agreement with field and wind tunnel concentration data. The deviation between model results and field experimental data is of the same order as the deviation between field and wind tunnel data.  相似文献   
4.
5.
Dispersion of atmospheric contaminants in the vicinity of an isolated cubical model building was investigated in the field. A dual source/receptor technique was used in the experiments, which was proved to be very useful for the investigation of pollution dispersion. This experimental technique involved the simultaneous release of two different tracer gases from two different point sources, and the deployment of a FID (Flame Ionization Detector) co-located with a UVIC®(Ultra-Violet Ion Collector) detector. Both mean concentrations and concentration fluctuation statistics were examined. In this paper concentration fluctuation statistics are presented. The effect of the upwind source location on intermittency values and on the cumulative density function (cdf) is examined. The exact location of a source placed upwind of an obstacle has a very significant and complex effect on both mean concentrations and concentration fluctuations. As the lateral or vertical displacement between the two sources is increased, cross-correlation values between data taken simultaneously by two co-located detectors decrease rapidly.  相似文献   
6.
Simultaneous measurements of indoor and outdoor carbon monoxide (CO) concentrations conducted at two different microenvironments in Athens, Greece, using a non-dispersive infrared analyzer, are described in this paper. The two selected microenvironments, an office and a public school, were located in the vicinity of two streets with heavy traffic, near the center of Athens. A statistical correlation analysis of indoor concentration levels with outdoor concentrations monitored at the school and at the office, as well as with meteorological parameters and outdoor concentrations monitored at a fixed monitoring site, was conducted. Hourly indoor concentrations at the office and at the school showed a significant positive correlation with outdoor concentrations measured at both measurement locations (with correlation coefficient values R=0.74 and R=0.83 respectively) and at the fixed site (with R=0.70 and R=0.67 respectively). The correlation between indoor and outdoor concentrations was even better when hourly concentrations averaged over a 4 h period were considered (correlation coefficient values between indoor and outdoor concentrations measured at the office and at the school were R=0.85 and R=0.92 respectively and the correlation coefficient value between indoor and outdoor fixed site concentrations was R=0.75 for both sites). Mean hourly outdoor concentrations at the fixed monitoring site explained approximately 56% (R=0.75) of the variation of outdoor concentrations at the office and approximately 68 % (R=0.83) of the variation of outdoor concentrations at the school. The mean daily indoor to outdoor (I/O) ratio ranged between 0.74 and 1.00 at the office and between 0.53 and 0.89 at the school.  相似文献   
7.

Annoyance caused by air pollution is a matter of public health as it can cause stress and ill-health and affect quality of life, among other burdens. The aim of this study is to apply the multiple correspondence analyses (MCA) technique as a differential tooling to explore relationships between variables that can influence peoples’ behaviour concerning annoyance caused by air pollution. Data were collected through a survey on air pollution, environmental issues and quality of life. Face-to-face survey studies were conducted in two industrialized urban areas (Vitoria in Brazil and Dunkirk in France). These two regions were chosen as their inhabitants often report feeling annoyed by air pollution, and both regions have similar industrial characteristics. The results showed a progressive correspondence between levels of annoyance and other active variables in the “air pollution” factor group: as the levels of annoyance increased, the levels of the other qualitative variables (importance of air quality, perceived exposure to industrial risk, assessment of air quality, perceived air pollution) also increased. Respondents who reported feeling annoyed by air pollution also thought that air quality was very important and were very concerned about exposure to industrial risks. Furthermore, they often assessed air quality as horrible, and they could frequently perceive air pollution by dust, odours and decreased visibility. The results also showed a statistically significant association between occurrence of allergies and high levels of annoyance.

  相似文献   
8.
- DOI: http://dx.doi.org/10.1065/espr2006.04.299 Goal, Scope and Background This paper describes a statistical modelling approach, suggested as a policy tool in the Athens area for the assessment of the emissions reduction level required to meet the air quality standards for two criteria air pollutants, namely CO and NO2. Methods. More than ten years of hourly CO and NOx-NO2 concentration data measured by the monitoring network of the Hellenic Ministry for the Environment, Physical Planning and Public Works were analyzed and the original dataset has been reduced using a data evaluation procedure. Results and Discussion Seasonal pollutant concentration trends suggested that the reduction of CO and NOx concentrations observed in the beginning of the '90s is almost entirely attributed to the increase of the catalyst-equipped cars during this period. The numerical parameters of an empirical model relating EU standard exceedances with mean annual concentrations were defined and the model was validated using datasets from years that were not used for the estimation of these parameters. This model was used in conjunction with a roll-back equation as a policy tool for the assessment of the effect of different CO and NOx emissions reduction scenarios on air quality standard compliance for CO and NO2. Results predicted with this empirical modelling approach were assessed with monitored data averaged over a 3-year period, giving satisfactory results. Conclusion A methodology suggested for assessing the effects of different emissions reduction scenarios on air quality standard attainment was successfully applied for CO and NO2 in the Athens area. Recommendation and Perspective The proposed methodology can provide a useful tool for the evaluation of policies already in progress as well as the development of future policies for emissions reduction in urban areas with similar characteristics, aiming at air quality standard compliance on a timely manner. Such a methodology could be applied in other urban areas of Greece characterized by dense traffic, therefore assisting the development of national policies in relation to air pollutants for which standard exceedances occur.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号