首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   6篇
  免费   0篇
  国内免费   1篇
环保管理   1篇
综合类   1篇
污染及防治   2篇
评价与监测   1篇
社会与环境   1篇
灾害及防治   1篇
  2014年   1篇
  2013年   2篇
  2005年   1篇
  2004年   1篇
  2001年   1篇
  1981年   1篇
排序方式: 共有7条查询结果,搜索用时 15 毫秒
1
1.
Large-scale exposure of acid sulfate soils during a hydrological drought in the Lower Lakes of South Australia resulted in acidification of surface water in several locations. Our aim was to describe the techniques used to monitor, assess and manage these acidification events using a field and laboratory dataset (n?=?1,208) of acidic to circum-neutral pH water samples. The median pH of the acidified (pH?<?6.5) samples was 3.8. Significant (p?<?0.05) increases in soluble metals (Al, Co, Mn, Ni and Zn above guidelines for ecosystem protection), SO4 (from pyrite oxidation), Si (from aluminosilicate dissolution) and Ca (from carbonate dissolution and limestone addition), were observed under the acidic conditions. The log of the soluble metal concentrations, acidity and SO4/Cl ratio increased linearly with pH. The pH, alkalinity and acidity measurements were used to inform aerial limestone dosing events to neutralise acidic water. Field measurements correlated strongly with laboratory measurements for pH, alkalinity and conductivity (r 2?≥?0.97) but only moderately with acidity (r 2?=?0.54), which could be due to difficulties in determining the indicator-based field titration endpoint. Laboratory measured acidity correlated well with calculated acidity (r 2?=?0.87, acidity present as AlIII?>>?H+?≈?MnII?>?FeII/III) but was about 20 % higher on average. Geochemical speciation calculations and XRD measurements indicated that solid phase minerals (schwertmannite and jarosite for Fe and jurbanite for Al) were likely controlling dissolved metal concentrations and influencing measured acidity between pH 2 and 5.  相似文献   
2.
As an odorless, nontoxic, and inert compound, sulfur hexafluoride (SF6) is one of the most widely used tracer gases in indoor air quality studies in both controlled and uncontrolled environments. This compound may be subject to reactions with water vapor under elevated temperature to form acidic inorganic compounds such as HF and H2SO4. Thus, in the presence of unvented combustion sources such as kerosene heaters, natural gas heaters, gas log fireplaces, candles, and lamps, the SF6 dissociation may interfere with measurements of the emissions from these sources. Tests were conducted in a research house with a vent-free natural gas heater to investigate these potential interferences. It was observed that the heater operation caused about a 5% reduction of SF6 concentration, which can be an error source for the ventilation rate measurement and consequently the estimated pollutant emission rates. Further analysis indicates that this error can be much greater than the observed 5% under certain test conditions because it is a function of the ventilation flow rate. Reducing the tracer gas concentration has no effect on this error. A simple theoretical model is proposed to estimate the magnitude of this error. The second type of interference comes from the primary and secondary products of the SF6 dissociation, mainly H2SO4, SO2, HF, and fine particulate matter (PM). In the presence of approximately 5 ppm SF6, the total airborne concentrations of these species increased by a factor of 4-10. The tests were performed at relatively high SF6 concentrations, which is necessary to determine the interferences quantitatively. The second type of interference can be significantly reduced if the SF6 concentration is kept at a low ppb level.  相似文献   
3.
Mosley LM  Sharp DS  Singh S 《Disasters》2004,28(4):405-417
The effect of a cyclone (Ami, January 2003) on drinking-water quality on the island of Vanua Levu, Fiji was investigated. Following the cyclone nearly three-quarters of the samples analysed did not conform to World Health Organisation (WHO) guideline values for safe drinking-water in terms of chlorine residual, total and faecal coliforms, and turbidity. Turbidity and total coliform levels significantly increased (up 56 and 62 per cent, respectively) from pre-cyclone levels, which was likely due to the large amounts of silt and debris entering water-supply sources during the cyclone. The utility found it difficult to maintain a reliable supply of treated water in the aftermath of the disaster. Communities were unaware they were drinking water that had not been adequately treated. Circumstances permitted this cyclone to be used as a case study to assess whether a simple paper-strip water-quality test (the hydrogen sulphide, H(2)S) kit could be distributed and used for community-based monitoring following such a disaster event to better protect public health. The H(2)S test results correlated well with faecal and total coliform results as found in previous studies. A small percentage of samples (about 10 per cent) tested positive for faecal and total coliforms but did not test positive in the H(2)S test. It was concluded that the H(2)S test would be well suited to wider use, especially in the absence of water-quality monitoring capabilities for outer island groups as it is inexpensive and easy to use, thus enabling communities and community health workers with minimal training to test their own water supplies without outside assistance. The importance of public education before and after natural disasters is also discussed.  相似文献   
4.
Hypoxic blackwater events occur when large amounts of organic material are leached into a water body (e.g., during floodplain inundation) and rapid metabolism of this carbon depletes oxygen from the water column, often with catastrophic effects on the aquatic environment. River regulation may have increased the frequency and severity of hypoxic blackwater events in lowland river systems, necessitating management intervention to mitigate the impacts of these events on aquatic biota. We examine the effectiveness of a range of mitigation interventions that have been used during large-scale hypoxic blackwater events in the Murray–Darling Basin, Australia and that may be applicable in other environments at risk from hypoxic blackwater. Strategies for hypoxia mitigation include: delivery of dilution flows; enhancement of physical re-aeration rates by increasing surface turbulence; and diversion of blackwater into shallow off-channel storages. We show that the impact of dilution water delivery is determined by relative volumes and water quality and can be predicted using simple models. At the dilution water inflow point, localized oxygenated plumes may also act as refuges. Physical re-aeration strategies generally result in only a small increase in dissolved oxygen but may be beneficial for local refuge protection. Dilution and natural re-aeration processes in large, shallow lake systems can be sufficient to compensate for hypoxic inflows and water processed in off-channel lakes may be able to be returned to the river channel as dilution flows. We provide a set of predictive models (as electronic supplementary material) for estimation of the re-aeration potential of intervention activities and a framework to guide the adaptive management of future hypoxic blackwater events.  相似文献   
5.
A new semi-empirical, approximate theory for predicting electrical conditions is described. In the approximate theory, analytical expressions are derived for calculating voltage-current characteristics and electric potential, electric field, and space charge density distributions. Comparisons of numerical and approximate solutions over a wide range of possible precipitator geometries and electrical operating points indicates that for practical purposes the approximate theory can be used in lieu of the more rigorous numerical theory. This saves large amounts of computer time and makes possible hand calculator usage. Recent in situ gaseous ion mobility data which are needed in the models are presented. For coal fired power plants, the reduced effective ion mobility in positive corona is found to be 1.6 times that for negative corona. Approaches for describing particulate space charge effects in the gas and electrical conditions in the collected particulate layer are briefly discussed.  相似文献   
6.
中国煤中氟的含量及其分布   总被引:19,自引:1,他引:18  
在全国主要产煤的26个省、市和自治区根据各煤田的地质储量、成煤时期和煤变质程度,兼顾各矿区的煤炭产量,采集305个煤样,用高温热水解-离子选择性电极法测定了全部样品的氟含量.煤中的氟主要以无机形态赋存,氟含量和变质程度之间没有必然的联系.成煤时代等单一因素对氟含量的影响可能为其它各种因素的综合作用所掩盖,对此有必要进行更深入、具体的研究研究了各省、市和自治区的煤氟含量的分布,有必要重新审视、甄别燃煤型氟中毒区氟的来源.全国煤的氟含量服从对数正态分布,90%的样品含氟范围为47~347mg/kg,宜用几何平均值136mg/kg作为全国平均煤氟含量.与世界煤相比,中国煤氟含量并无异常.  相似文献   
7.
ABSTRACT

As an odorless, nontoxic, and inert compound, sulfur hexafluoride (SF6) is one of the most widely used tracer gases in indoor air quality studies in both controlled and uncontrolled environments. This compound may be subject to reactions with water vapor under elevated temperature to form acidic inorganic compounds such as HF and H2SO4. Thus, in the presence of unvented combustion sources such as kerosene heaters, natural gas heaters, gas log fireplaces, candles, and lamps, the SF6 dissociation may interfere with measurements of the emissions from these sources. Tests were conducted in a research house with a vent-free natural gas heater to investigate these potential interferences. It was observed that the heater operation caused about a 5% reduction of SF6 concentration, which can be an error source for the ventilation rate measurement and consequently the estimated pollutant emission rates. Further analysis indicates that this error can be much greater than the observed 5% under certain test conditions because it is a function of the ventilation flow rate. Reducing the tracer gas concentration has no effect on this error. A simple theoretical model is proposed to estimate the magnitude of this error.

The second type of interference comes from the primary and secondary products of the SF6 dissociation, mainly H2SO4, SO2, HF, and fine particulate matter (PM). In the presence of ~5 ppm SF6, the total airborne concentrations of these species increased by a factor of 4-10. The tests were performed at relatively high SF6 concentrations, which is necessary to determine the interferences quantitatively. The second type of interference can be significantly reduced if the SF6 concentration is kept at a low ppb level.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号