首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   15篇
  免费   0篇
  国内免费   5篇
综合类   7篇
基础理论   6篇
污染及防治   5篇
社会与环境   2篇
  2022年   1篇
  2021年   2篇
  2020年   3篇
  2013年   1篇
  2011年   4篇
  2010年   1篇
  2009年   2篇
  2006年   3篇
  2003年   1篇
  2002年   1篇
  2001年   1篇
排序方式: 共有20条查询结果,搜索用时 671 毫秒
1.
盆地地形导致的城区内小以厚度大,强逆温层出现频率高等大气不利扩散条件是造成重庆市主城区空气污染的重要原因,建议城市布局要符合空气动力学原理并通过工程措施改善城区大气扩散条件。  相似文献   
2.
Kraal P  Jansen B  Nierop KG  Verstraten JM 《Chemosphere》2006,65(11):2193-2198
The speciation of titrated copper in a dissolved tannic acid (TA) solution with an initial concentration of 4 mmol organic carbon (OC)/l was investigated in a nine-step titration experiment (Cu/OC molar ratio = 0.0030–0.0567). We differentiated between soluble and insoluble Cu species by 0.45 μm filtration. Measurements with a copper ion selective electrode (ISE) and diffusive gradients in thin films (DGT) were conducted to quantify unbound Cu(II) cations (‘free’ Cu) and labile soluble Cu complexes. For the DGT measurements, we used an APA hydrogel and a Chelex 100 chelating resin (Na form). Insoluble organic Cu complexes (>0.45 μm) was the dominant Cu species for Cu/OC = 0.0030–0.0567 with a maximum fraction of 0.96 of total Cu. At Cu/OC > 0.0100, Cu-catalysed degradation of aggregate structures resulted in a strong increase of free Cu and (labile) soluble Cu complexes with a maximum fraction of 0.28 and 0.32 of total Cu, respectively. Labile (i.e. DGT-detectable) soluble Cu complexes had a relatively high averaged diffusion coefficient (D) in the APA hydrogel (3.50 × 10−6– 5.58 × 10−6 cm2 s−1).  相似文献   
3.
• Selective molecularly imprinted polymer (MIP) binding gel was prepared. • MIP-DGT showed excellent uptake performance for antibiotics. • In situ measurement of antibiotics in wastewaters via MIP-DGT was developed. • The MIP-DGT method was robust, reliable, and highly sensitive. Urban wastewater is one of main sources for the introduction of antibiotics into the environment. Monitoring the concentrations of antibiotics in wastewater is necessary for estimating the amount of antibiotics discharged into the environment through urban wastewater treatment systems. In this study, we report a novel diffusive gradient in thin films (DGT) method based on molecularly imprinted polymers (MIPs) for in situ measurement of two typical antibiotics, fluoroquinolones (FQs) and sulfonamides (SAs) in urban wastewater. MIPs show specific adsorption toward their templates and their structural analogs, resulting in the selective uptake of the two target antibiotics during MIP-DGT deployment. The uptake performance of the MIP-DGTs was evaluated in the laboratory and was relatively independent of solution pH (4.0–9.0), ionic strength (1–750 mmol/L), and dissolved organic matter (DOM, 0–20 mg/L). MIP-DGT samplers were tested in the effluent of an urban wastewater treatment plant for field trials, where three SA (sulfamethoxazole, sulfapyridine, and trimethoprim) and one FQ (ofloxacin) antibiotics were detected, with concentrations ranging from 25.50 to 117.58 ng/L, which are consistent with the results measured by grab sampling. The total removal efficiency of the antibiotics was 80.1% by the treatment plant. This study demonstrates that MIP-DGT is an effective tool for in situ monitoring of trace antibiotics in complex urban wastewaters.  相似文献   
4.
The emergence of inhomogeneities in the distributions of the abundances of spatially extended prey-predator systems is investigated. The method of analysis, based on the notion of diffusive (Turing) instability, is systematically applied to nine different models obtained by introducing an extra-factor into the standard Rosenzweig-MacArthur prey-predator model. The analysis confirms that the standard model is critical in the context of Turing instability, and that the introduction of any small amount of the extra-factor can easily promote or inhibit the emergence of spatial patterns.  相似文献   
5.
潮滩沉积物-水界面营养盐N、P分布及交换特征   总被引:4,自引:0,他引:4  
通过2月枯季和8月洪季样品的采集、室内分析和测试,对滨岸带潮滩沉积物孔隙水中营养盐含量的分布、迁移和扩散通量进行了初步研究。结果表明,NH_4~--N和N0_3~--N的平均含量8月洪季比2月枯季低,但是NO_2-N含量在8月份却达到最高,为0.04 mg/L;TP在季节分布上变化不大,8月洪季时含量较高。在空间分布上发现,排污口及大面积围垦对营养盐局部分布的影响较大。营养盐剖面分布总体趋势为NH_4~--N含量随深度增加而增加,NO_3~--N随深度增加而减少,但同时受到沉积速率和污水排放的影响。潮滩沉积物—水界面间无机氮磷的平均扩散通量分别为7.15、-0.53μg/(cm~2·d),因此沉积物是N的输入源,P的汇。同时还发现,污染物的排放能极大地改变该地区的N、P迁移量甚至迁移方向。  相似文献   
6.
Surface ozone concentration and surface air temperature was measured hourly at three coastal sites, four low elevation inland sites and two high elevation inland sites in southwestern Sweden. Diurnal ozone concentration range (DOR) and diurnal temperature range (DTR) were strongly correlated, both spatially and temporally, most likely because both depended on atmospheric stability. Accumulated ozone exposure above a threshold concentration of x nmol mol1 (AOTx) was estimated from time-integrated ozone concentration (as from diffusive sampling) and measures of ozone concentration variability. Two methods both estimated 24-h AOTx with high accuracy (modelling efficiencies >90% for x ≤ 40 nmol mol−1). Daytime (08:00–20:00) AOTx could not be equally well estimated. Estimates were better for lower AOT thresholds. Diffusive ozone concentration sampling, combined with hourly temperature monitoring, could be a valuable complement to ozone concentration monitoring with continuous instruments.  相似文献   
7.
The present work relates to galvanized structures with several years of time life subjected to atmospheric corrosion, like galvanized high tension steel pylons. The mass and fate of zinc released is evaluated both via empirical and experimental procedures. The corrosion rate determination requested atmospheric condition characterization, especially for SO 2 concentration and experimental activities focused on soil sampling around pylons. The soil zinc content, total and exchangeable, is determinates by different analytical procedures. The zinc diffusion in environment and the zinc extension under the top soil is evaluated using 1-dimensional mathematical model for miscible species in porous soil.  相似文献   
8.
Macrophytes are usually chosen for phytoremediation tools to remove P in eutrophic aquatic ecosystems, but the lack of test methods hinders the understanding of removal mechanism and application. In this study, we used the novel technologies combined of Diffusive gradients in thin films (DGT), Planar optode (PO), and Non-invasive micro-test technology (NMT) to explore P dynamics in water-sediment continuum and rhizosphere of Potamogeton crispus over time. Results of the high-resolution in situ measurement showed that labile P(LPDGT) fluxes at the surficial sediment significantly decreased from approximate 120, 140, and 200 pg/ (cm2?sec) via 30 days incubation period to 17, 40, and 56 pg/(cm2?sec) via that of 15 days. Obvious synchronous increase of LPDGT was not detected in overlying water, suggesting the intense assimilation of dissolve reactive P via root over time. PO measurement indicated that O2 concentration around the rhizosphere remarkably increased and radially diffused into deeper sediment until 100% saturation along with the root stretch downwards. NMT detection of roots showed the obvious O2 inflow into root tissue with the uppermost flux of 30 pmol/(cm2?sec) from surroundings via aerenchyma on different treatment conditions. Different from previous reports, gradually saturating O2 concentrations around the rhizosphere was principally driven by O2 penetration through interspace attributing to root stretch downward rather than root O2 leakage. Increased O2 concentrations in deep sediment over time finally induced the oxidization of labile Fe(II) into Fe(III) bound P and local P immobilization.  相似文献   
9.
The passive sampling technique, diffusive gradients in thin films (DGT) has attracted increasing interests as an in-situ sampler for organic contaminants including per- and polyfluoroalkyl substances (PFAS). However, its effectiveness has been questioned because of the small effective sampling area (3.1 cm2). In this study, we developed a DGT probe for rapid sampling of eight PFAS in waters and applied it to a water-sediment system. It has a much larger sampling area (27 cm2) and as a result lower method quantification limits (0.15 – 0.21 ng/L for one-day deployment and 0.02 – 0.03 ng/L for one-week deployment) and much higher (by > 10 factors) sampling rate (100 mL/day) compared to the standard DGT (piston configuration). The sampler could linearly accumulate PFAS from wastewater, was sensitive enough even for a 24 hr deployment with performance comparable to grab sampling (500 mL). The DGT probe provided homogeneous sampling performance along the large exposure area. The use of the probe to investigate distributions of dissolved PFAS around the sediment-water interface was demonstrated. This work, for the first time, demonstrated that the DGT probe is a promising monitoring tool for trace levels of PFAS and a research tool for studying their distribution, migration, and fate in aquatic environments including the sediment-water interface.  相似文献   
10.
Two types of diffusive samplers, both of which are compatible with thermal desorption, but differ in their geometry—SKC-Ultra (badge-type) and Radiello (radial symmetry-type)—were evaluated indoors and outdoors under varying temperature, humidity and wind speed conditions, using the graphitized adsorbents Carbopack X or Carbograph 5 to measure 1,3-butadiene and benzene in ambient air. The results obtained by diffusive sampling were compared with results obtained using a conventional active sampling method over both long (1 week) and shorter periods (6–24 h). Analysis and detection were performed using an automatic thermal desorber (ATD) connected to a gas chromatograph-flame ionization detector (GC/FID). Results from each sampler and adsorbent combination were examined using ordinary or multiple linear regression analysis. The overall uncertainty (OU) was also determined. In general, the results obtained with both samplers showed good agreement with those obtained by active sampling. Carbopack X appeared to be a more efficient adsorbent than Carbograph 5 for 1,3-butadiene, but the two adsorbents were equivalent for benzene. No effects of either humidity or air velocity were observed. Minor temperature effects were observed for both samplers for 1,3-butadiene. In summary, the results confirmed the accuracy of sampling rates previously determined for the two samplers and adsorbents. We consider the two samplers to be suitable for stationary and personal monitoring for the general population of 1,3-butadiene and benzene in various environments, indoors and outdoors. They are almost independent of meteorological conditions and may be suitable for monitoring industrial atmospheres.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号