毛细管柱气相色谱法测定水质五氯酚
引用本文:褚春莹,宣肇菲,房贤文,谭培功.毛细管柱气相色谱法测定水质五氯酚[J].干旱环境监测,2009,23(3):145-147,151.
作者姓名:褚春莹  宣肇菲  房贤文  谭培功
作者单位:青岛市环境监测中心站,山东,青岛,266003
摘    要:用乙酸酐衍生,正己烷液一液萃取,毛细管柱气相色谱-电子捕获检测器对地表水、废水中五氯酚进行了测定,确定五氯酚浓度范围在5.0—500μg/L之间时,样品的测定精度、回收率及方法检出限均能满足要求。

关 键 词:五氯酚  衍生化  毛细管柱  气相色谱  电子捕获检测器

Determination of Pentachlorophenol in Water by Capillary Gas Chromatography
CHU Chun-ying,XUAN Zhao-fei,FANG Xian-wen,TAN Pei-gong.Determination of Pentachlorophenol in Water by Capillary Gas Chromatography[J].Arid Environmental Monitoring,2009,23(3):145-147,151.
Authors:CHU Chun-ying  XUAN Zhao-fei  FANG Xian-wen  TAN Pei-gong
Institution:CHU Chun-ying,XUAN Zhao-fei,FANG Xian-wen,TAN Pei-gong(Qingdao Environmental Monitoring Centre,Qingdao Shandong 266003,China)
Abstract:Derivatization with acetic anhydride and liquid- liquid extraction with hexane, pentachlorophenol(PCP) was determined by capillary gas chromatographyelectron capture detector(GC - ECD) in surface water, waste water and sewage. As PCP concentration range between 5.0- 500μg/L, the accuracy, precision, recovery rate and detection limit were up to requirement.
Keywords:Pentachlorophenol  derivatization  capillary  gas chromatogram  electron capture detector  