首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
ABSTRACT: Evaporative heat loss is an essential component of any heat budget used for the modeling of lake water temperatures. Seven evaporative heat loss equations were tested in a year-round, physically-based temperature and dissolved oxygen model for lakes. Deciding which equation to choose for use in the year-round model was based on the goodness of fit of the simulated vs. measured surface temperatures, which were taken at a depth of 1 m below the water surface. An equation which includes free and forced convection components and which was previously used for cooling ponds gave the best fit between temperature simulations and measurements.  相似文献   

2.
ABSTRACT: Continuous measures of net productivity at discrete depths in standing waters may be obtained using diurnal free oxygen measurements and estimates of the vertical mixing. If oxygen concentration and vertical mixing are known in a laterally homogeneous water body, the only unknown term in the oxygen mass-balance equation is net productivity. If this is represented by a Fourier series, the equation may be solved and Fourier coefficients selected so that the sum of square errors between the oxygen measurements and predictions of the equation is minimized; the Fourier series then describes the diurnal variation of net productivity.  相似文献   

3.
A phase change material (PCM)-based flat plate modular heat exchanger for free cooling application, suitable for the diurnal temperature variation that prevails during the summer months of Bangalore city, India is designed and experimentally investigated. The flow and other parameters selected in the present study are meant to suit the accelerated charging of the PCM in the modular heat exchanger during the early morning hours, and to provide cool energy to the room during the daytime, by circulating the ambient air through the heat exchanger at a lower velocity. It is observed from the charging experiments that the decrease in the inlet air temperature has more influence in reducing the solidification time than the increase in the inlet air velocity. The heat exchanger designed in the present investigation is capable of maintaining the room temperature around 30°C for a longer duration of 8 hr when the heat load is 0.5 kW. It is suggested to design the modular heat exchanger with a surface area proportionate to the present heat exchanger size when the room heat load increases beyond 0.5 kW, in order to maintain a minimum comfortable temperature of 30°C in the room.  相似文献   

4.
ABSTRACT: A continuous simulation approach is proposed for estimating water temperature exceedance probabilities using thermo-hydrodynamic modeling. The approach uses (1) a deterministic unsteady flow and heat transport model, (2) continuous hydrological and meteorological data for a long historical period, and (3) synthetic records of tributary water temperatures and other model inputs. Representative historical records of streamflow, air temperatures, and other hydrometeorological variables are obtained from nearby gages. Stochastic modeling methods are used to construct synthetic records for other model inputs, including inflow water temperatures. An application of this deterministic-stochastic approach is presented for a complex waterway in northeastern Illinois with heat discharges from several power plants and wastewater treatment plants. Statistical results from the continuous simulations are compared to results obtained from traditional event simulations. The application illustrates the information that engineers and biologists can obtain for (1) evaluating compliance with water temperature standards, and (2) assessing the effect of water temperatures on aquatic habitat.  相似文献   

5.
6.
In this paper, conventional response surface methodology (RSM) based on low-order polynomials and an alternative Kriging-based method are used for the model-based single and multi-objective optimization of fatty-acid methyl ester (FAME) production catalyzed by a novel crude lipase from the yeast Cryptococcus diffluens (D44). The coefficient of determination for the two modeling approaches was calculated as 0.97 for the Kriging method, and 0.86 for RSM; showing a more reliable representation of experimental data by Kriging. Both models were used to perform single (maximizing FAME titer and temporal productivity separately) and multi-objective (maximizing FAME titer and temporal productivity simultaneously) optimizations of four important operating conditions (reaction time and temperature; amount of crude enzyme; and volume of methanol used). In all cases, the highest temperature considered (60°C) gave the best results. A reduction of reaction time in half was seen to be necessary to achieve optimum productivity compared to titer, when the two objectives were considered separately. The observed trade-off between the two objectives was quantified via multi-objective optimization using Pareto-front analysis.  相似文献   

7.
Abstract: A numerical model has been developed to simulate the hydraulic and heat transfer properties of a stormwater detention pond, as part of a simulation tool to evaluate thermal pollution of coldwater streams from stormwater runoff. The model is dynamic (unsteady) and based on principles of fluid mechanics and heat transfer. It is driven by hourly weather data, and specified inflow rates and temperatures. To calibrate and validate the pond model field data were collected on a commercial site in Woodbury, Minnesota. The relationship between pond inflow and outflow rates to precipitation was effectively calibrated using continuously recorded pond levels. Algorithms developed for surface heat transfer in lakes were found to be applicable to the pond with some modification, resulting in agreement of simulated and observed pond surface temperature within 1.0°C root mean square error. The use of an unshaded pond for thermal mitigation of runoff from paved surfaces was evaluated using the pond model combined with simulated runoff from an asphalt parking lot for six years of observed rainfall events. On average, pond outflow temperature was 1.2°C higher than inflow temperature, but with significant event‐to‐event variation. On average, the pond added heat energy to runoff from an asphalt parking lot. Although the pond added total heat energy to runoff, it did reduce the rate of heat outflow from the pond by an order of magnitude due to reductions in volumetric outflow rate compared with the inflow rate. By reducing the rate of heat flow, the magnitude of temperature impacts in a receiving stream were also reduced, but the duration of impacts was increased.  相似文献   

8.
Abstract: The summertime heating of runoff in urban areas is recognized as a common and consistent urban climatological phenomenon. In this study, a simple thermal urban runoff model (TURM) is presented for the net energy flux at the impervious surfaces of urban areas to account for the heat transferred to runoff. The first step in developing TURM consists of calculating the various factors that control how urban impervious areas absorb heat and transfer it to moving water on the surface. The runoff temperature is determined based on the interactions of the physical characteristics of the impervious areas, the weather, and the heat transfer between the moving film of runoff and the impervious surface common in urban areas. Key surface and weather factors that affect runoff temperature predictions are type of impervious surface, air temperature, humidity, solar radiation before and during rain, rainfall intensity, and rainfall temperature. Runoff from pervious areas is considered separately and estimated using the Green‐Ampt Mein‐Larson rainfall excess method. Pervious runoff temperature is estimated as the rainfall temperature. Field measurements indicate that wet bulb temperature can be used as a surrogate for rainfall temperature and that runoff temperatures from sod average just 2°C higher than rainfall temperatures. Differences between measured and predicted impervious runoff temperature average approximately 2°C, indicating that TURM is a useful tool for determining runoff temperatures for typical urban areas.  相似文献   

9.
With the trend towards increasing the speed of processors in smaller sized of computers, there has been considerable interest in heat sink technologies with higher levels of performance and further miniaturization. This work addresses the fundamental heat transfer augmentation question of how to design a copper-based heat sink, when the overall dimensions of the bottom plate or fan are specified. A three-dimensional finite-volume model has been developed and applied to investigate flow and conjugate heat transfer in the copper-based heat sink. The model was produced with the commercial program FLUENT, which allows this nonlinear, highly turbulent problem to be simulated using the k-ε turbulence model. The theoretical model developed is validated by comparing the model predictions with available experimental data. The thermal performance and temperature distribution for the heat sink were analyzed and a procedure for optimizing the geometrical design parameters based on less space occupation and more efficient heat transfer coefficient is presented. Several design examples with different types of cooling methods and manufacturing processes have been analyzed. The reliability and effectiveness in heat spreading of those has been compared. It has been shown that the copper-based heat sink with louvered fins (case No.3) has an optimum design configuration.  相似文献   

10.
A combined photovoltaic–thermal (PV/t) panel is proposed to produce simultaneously electricity and heat from one integrated unit. The unit utilizes effectively the solar energy through achieving higher PV electrical efficiency and using the thermal energy for heating applications. To predict the performance of the PV/t at a given environmental conditions, a transient mathematical model was developed. The model was integrated in a heating application for a typical office space in the city of Beirut to provide the office needs for electricity, heating during winter season, and dehumidification and evaporative cooling during the summer season. To minimize the yearly office energy (electrical and heat) needs, the PV/t panel cooling air flow rate and the dehumidification regeneration temperature were determined for opimal unit operation. Thermal energy savings of up to 85% in winter and 71% in summer were achived compared to conventional systems at a payback period of 8 years for the panels.  相似文献   

11.
ABSTRACT: A vertical dissolved oxygen model was calibrated and verified using independent field data sets from 1972 and 1973 in Lake Lyndon B. Johnson (LBJ), a short detention time reservoir with anaerobic hypolimnion. Ammonia, carbonaceous BOD, conductivity, and temperature were also simulated as state variables. The conductivity results provided a check on the mass balance and the method of entering the inflows to the reservoir model. Emphasis was placed on calculating the sinks of dissolved oxygen in the hypolimnion which could be useful in management decisions.  相似文献   

12.
Chemical-looping combustion is a novel combustion technology with inherent separation of the greenhouse gas CO2. The technology uses circulating oxygen carriers to transfer oxygen from the combustion air to the fuel. In this paper, oxygen carriers based on commercially available NiO and α-Al2O3 were prepared using the industrial spray-drying method, and compared with particles prepared by freeze-granulation. The materials were investigated under alternating oxidizing and reducing conditions in a laboratory fluidized bed, thus simulating the cyclic conditions of a chemical-looping combustion system. The particles produced by spray-drying displayed a remarkable similarity to the freeze-granulated oxygen carriers, with high reactivity when the bed was fluidized and similar physical properties when sintered at the same temperature. This is an important result as it shows that the scaling-up from a laboratory production method, i.e. freeze-granulation, to a commercial method suitable for large-scale production, i.e. spray-drying, did not involve any unexpected difficulties. A difference noticed between the spray-dried and freeze-granulated particles was the sphericity. Whereas the freeze-granulated particles showed near perfect sphericity, a large portion of the spray-dried particles had hollow interiors. Defluidization was most likely to occur for highly reduced particles, at low gas velocities. The apparent density and crushing strength of the oxygen carriers could be increased either by increasing the sintering temperature or by increasing the sintering time. However, the fuel conversion was fairly unchanged when the sintering temperature was increased but was clearly improved when the sintering time was increased.  相似文献   

13.
ABSTRACT

In this study, a three-dimension (3D) computational model was proposed to investigate the flow and heat transfer characteristics of the intake grilles of two different fuel cell vehicles. The models of the intake grilles were constructed according to the actual sizes of two vehicles, namely, Roewe 950 and Toyota Mirai, considering the heat dissipation unit to simplify the heat transfer model of the vehicle. The results showed that relative to Roewe 950, Mirai intake air flow rate was approximately 10% higher, the heat transfer capacity was approximately 7% higher, and the intake grille area was larger. The coolant outlet temperature of Mirai was lower than that of Roewe 950, which was beneficial for the long term and stable operation of a fuel cell. This comparative study provided guidance for the intake grille and radiator design of fuel cell vehicles. The only difference between fuel cell vehicles on the market and conventional vehicles was that in the former, the internal combustion engine was replaced with a fuel cell stack, which had insufficient heat transfer capacity because of the reducing temperature difference. Increasing the intake grille area and the heat exchange capacity of the radiator were the key issues for the development of fuel cell vehicles. In this study, an optimal window opening angle of the radiator fin of 23° provided a maximal heat transfer coefficient.  相似文献   

14.
研究了短时游离氯后转氯胺的联合消毒方法对大肠杆菌的灭活作用,并对其协同作用以及pH值和温度对协同作用的影响进行了探讨。结果表明:pH值在6.5~8范围内,温度不超过30℃时,短时游离氯后转氯胺的消毒方法对大肠杆菌的灭活具有协同作用,且随pH值的降低而加强,在低温下该方法的协同效果更加明显。  相似文献   

15.
利用静海国家气象站1960~2019年日最高气温资料对静海高温天气发生的开始和结束时间、次数进行了统计,分析了持续高温天气过程的年际变化规律、时间演变特征,利用Mann-Kendall法对高温日数、年最高气温进行趋势检验;构建了日高温发生概率的“钟形”曲线模型,利用傅里叶变换分析日高温发生概率序列的主要分量,构建了基于傅里叶级数的日高温发生概率简化模型。结果表明:1960年至1996年静海年高温日数呈下降趋势,1997年开始年高温日数呈上升趋势,而年最高气温无显著的上升趋势;静海高温天气过程主要为持续1~2天的过程,近20年高温热浪发生次数明显增加;近60年高温日开始时间提前,结束时间推迟的趋势明显;模型较好的模拟了日高温发生概率的变化特征。  相似文献   

16.
ABSTRACT Atmospheric scientists have predicted that large-scale climatic changes will result from increasing levels of tropospheric CO2 We have investigated the potential effects of climate change on the primary productivity of Castle Lake, a mountain lake in Northern California. Annual algal productivity was modeled empirically using 25 years of limnological data in order to establish predictive relationships between productivity and the climatic variables of accumulated snow depth and precipitation. The outputs of monthly temperature and precipitation from three general circulation models (GCMs) of doubled atmospheric CO2 were then used in the regression model to predict annual algal productivity. In all cases, the GCM scenarios predicted increased algal productivity for Castle Lake under cenditions of doubled atmospheric CO2The primary cause of enhanced productivity was the increased length of the growing season resulting from earlier spring ice-out.  相似文献   

17.
The Influence of mixed and pure working fluids on the performance of organic Rankine cycles (ORCs) is discussed. Specifically, the performance of mixed and pure working fluids is analyzed based on certain characteristics of low-temperature heat source and heat sink. A method of selecting binary zeotropic mixed working fluids that match with different heat sinks is introduced. Thermodynamic processes of ORCs for various heat sources are simulated in Matlab. The performance characteristics of pure and mixed working fluids are compared under different inlet temperatures and temperature gradients of sensible heat sources. The results demonstrate that when the initial temperature of a heat source is lower and its temperature gradient is higher, and the temperature gradient of the heat sink is higher, mixed working fluids have better performance than pure working fluids. However, for the opposite heat source and heat sink situations, pure working fluids perform better. Mixtures with low critical temperature components exhibit the best performance among all working fluids when the temperature gradient of the heat source is large. The analysis also shows that introduction of a recuperator may reduce the cycle efficiency when the heat source temperature is low and the temperature gradient of the heat source is large.  相似文献   

18.
ABSTRACT: A simulation model [Salmonid Spawning Analysis Model (SSAM)] was developed as a management tool to evaluate the relative impacts of stream sediment load and water temperature on salmonid egg survival. The model is useful for estimating acceptable sediment loads to spawning habitat that may result from upland development, such as logging and agriculture. Software in common use in the USA were adapted for use in gravel bedded rivers and linked to simulate water temperature (the USFWS Instream Water Temperature, SNTEMP model) and water and sediment routing (the USAE Scour and Deposition in Rivers and Reservoirs, HEC-6 model, version 3.2). These models drive the redd (spawning nest) model (the USDA-ABS Sediment Intrusion Dissolved Oxygen SIDO model) which simulates sediment intrusion and dissolved oxygen concentration in the redd environment. The SSAM model predictions of dissolved oxygen and water temperature compared favorably with field data from artificial redds containing hatchery chinook salmon eggs.  相似文献   

19.
This study examined algal productivity and nitrate assimilation in a 2.85 km reach of Cucamonga Creek, California, a concrete lined channel receiving treated municipal wastewater. Stream nitrate concentrations observed at two stations indicated nearly continuous loss throughout the diel study. Nitrate loss in the reach was approximately 11 mg/L/d or 1.0 g/m2/d as N, most of which occurred during daylight. The peak rate of nitrate loss (1.13 mg/l/hr) occurred just prior to an afternoon total CO2 depletion. Gross primary productivity, as estimated by a model using the observed differences in dissolved oxygen between the two stations, was 228 mg/L/d, or 21 g/m2/d as O2. The observed diel variations in productivity, nitrate loss, pH, dissolved oxygen, and CO2 indicate that nitrate loss was primarily due to algal assimilation. The observed levels of productivity and nitrate assimilation were exceptionally high on a mass per volume basis compared to studies on other streams; these rates occurred because of the shallow stream depth. This study suggests that concrete‐lined channels can provide an important environmental service: lowering of nitrate concentrations similar to rates observed in biological treatment systems.  相似文献   

20.
油田注汽锅炉烟气余热利用与低碳减排   总被引:1,自引:1,他引:0  
通过对注汽锅炉烟气余热利用潜力的分析及开展余热利用方式对比分析,采用在注汽锅炉对流段上安装热管换热器,使高温烟气与助燃空气换热,利用换热器回收烟气余热。该技术的现场应用,实现了注汽锅炉燃料单耗降低和污染物排放量降低的目的,取得了良好的节能、减排效果。  相似文献   