首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 203 毫秒
1.
A combined photovoltaic–thermal (PV/t) panel is proposed to produce simultaneously electricity and heat from one integrated unit. The unit utilizes effectively the solar energy through achieving higher PV electrical efficiency and using the thermal energy for heating applications. To predict the performance of the PV/t at a given environmental conditions, a transient mathematical model was developed. The model was integrated in a heating application for a typical office space in the city of Beirut to provide the office needs for electricity, heating during winter season, and dehumidification and evaporative cooling during the summer season. To minimize the yearly office energy (electrical and heat) needs, the PV/t panel cooling air flow rate and the dehumidification regeneration temperature were determined for opimal unit operation. Thermal energy savings of up to 85% in winter and 71% in summer were achived compared to conventional systems at a payback period of 8 years for the panels.  相似文献   

2.
A model is developed to predict the evaporative heat transfer coefficient in a horizontal tube-falling evaporator and has been applied to evaluate overall performance of a desalination unit. Performance variation with different parameters like operation temperature, type of water distribution system, mass flow rate of distilled water inside the exchanger are analyzed. It has been observed that the model is able to predict the trends of heat transfer characteristics of the evaporator reasonably well. However, at low liquid film flow rate conditions, the model overpredicts the heat transfer characteristics marginally. In order to improve the evaporative exchanger performance, it is observed that preheating of the liquid film before injection into the evaporator is desirable. Calculations are also performed to estimate the value of overall heat transfer coefficient for a typical desalination unit.  相似文献   

3.
In this communication, a new design of solar-energy-based water distillation cum drying unit with parabolic reflector has been designed, fabricated, and tested. Bitter gourd and potato slices are chosen as a drying commodity. Thermal performance of the developed system has been evaluated based on the experimental results and using linear regression analysis. Heat transfer coefficients (convective, evaporative, and radiative) for solar distillation system have been observed to be 2.48–4.09, 13.25–52.38, and 8.75–9.66 W/m2°C, respectively. Overall thermal efficiency and exergy efficiency for the distillation system has been found to be 18.77% and 1.2%, respectively. The convective heat transfer coefficient for potato slices are observed higher for initial hours and decreases as the day progresses. The average convective heat transfer coefficients for bitter gourd and potato slices have been observed as 2.18 and 5.04 W/m2°C, respectively. Experimental error in terms of percent uncertainty for bitter gourd and potato slices are found to be 42.93% and 37.06%, respectively. The present design of solar distillation and drying in a single unit could be beneficial for the development of remote, arid, and rural areas.  相似文献   

4.
Evaporative cooling of water in a small porous clay vessel was studied under controlled humidity conditions. In steady-state experiments performed at an ambient temperature of 23 °C, the cooling effect increased from 4.7 to 8.3 °C as the ambient relative humidity decreased from 60 to 15%. External heat and mass transfer coefficients, estimated from the steady-state measurements, were used in mathematical models to predict the experimentally observed transient temperature variation of the water under ramp changes of the ambient relative humidity. With a prototypical cool chamber containing water tested in Kolkata, India under an ambient temperature of 34.5–35 °C, the cooling effect reached a maximum of 7 °C between 3 and 3:30 PM and then declined to 4.5 °C around 6 PM.  相似文献   

5.
The performance of the designed tilted wick solar water distillation-cum-drying unit has been tested at water flow rates of 50 and 65 ml/min in the distillation unit. Effect of water flow rates on the heat transfer coefficients of distillation and drying unit for drying ginger has been evaluated. The energy and exergy efficiency of the distillation system have also been evaluated. Average distillates of 2.36 and 2.2 l/m2 were collected from the tilted wick solar still at flow rates of 50 and 65 ml/min, respectively. Large variation in convective and evaporative heat transfer coefficients of distillation unit has been observed at given water flow rates. Water flow rate in the distillation unit significantly affects the performance of the drying unit. Average convective heat transfer coefficients of 6.56 and 3.75 W/m2 oC have been observed for drying ginger at flow rates of 50 and 65 ml/min, respectively. Energy and exergy efficiency of the distillation unit have been found to be nearly 19% and 0.9%, respectively. Experimental uncertainty has also been evaluated for distillation and drying units. The distillate cost for the developed distillation-cum-drying unit is calculated as $0.03729/l along with dried ginger of about 2.5 kg/m2/day.  相似文献   

6.
ABSTRACT

In this study, a three-dimension (3D) computational model was proposed to investigate the flow and heat transfer characteristics of the intake grilles of two different fuel cell vehicles. The models of the intake grilles were constructed according to the actual sizes of two vehicles, namely, Roewe 950 and Toyota Mirai, considering the heat dissipation unit to simplify the heat transfer model of the vehicle. The results showed that relative to Roewe 950, Mirai intake air flow rate was approximately 10% higher, the heat transfer capacity was approximately 7% higher, and the intake grille area was larger. The coolant outlet temperature of Mirai was lower than that of Roewe 950, which was beneficial for the long term and stable operation of a fuel cell. This comparative study provided guidance for the intake grille and radiator design of fuel cell vehicles. The only difference between fuel cell vehicles on the market and conventional vehicles was that in the former, the internal combustion engine was replaced with a fuel cell stack, which had insufficient heat transfer capacity because of the reducing temperature difference. Increasing the intake grille area and the heat exchange capacity of the radiator were the key issues for the development of fuel cell vehicles. In this study, an optimal window opening angle of the radiator fin of 23° provided a maximal heat transfer coefficient.  相似文献   

7.
This study analyzed the wintertime surface heat exchange for the Inner Mongolia reach of the Yellow River, China, based on the data from the nearby weather station at Wulateqianqi. In this analysis, the solar radiation is based on the observed data. Other components of the surface heat flux, that is, long‐wave radiation, and evaporative and conductive heat fluxes, are calculated. The relative importance of the contributions of long‐wave radiation, conductive, and evaporative heat fluxes are in descending order. The air temperature is the most important meteorological factor to the total heat flux. Although the wind speed influences evaporative and conductive heat fluxes, it has the least correlation with the total heat budget. The heat exchange coefficient for the linearized surface heat exchange equation is 21.87 W/(m2 °C), which is comparable with published values in the regions of United States and Canada with similar latitudes.  相似文献   

8.
As a consequence of the Kyoto Protocol and its predecessor, the Montreal Protocol, environmental considerations will play an important role in the choice of a refrigeration or heat pump system. Accordingly, sorption technology is expected to develop for cooling as well as for heat pump applications because it uses benign fluids. At the moment, liquid absorption technology is the leading technology in that field; however, adsorption offers advantages that cannot be achieved by liquid absorption technology. This article addresses the measures to reduce halocarbon emissions and the possibilities of adsorption technology. Not only are the direct emissions taken into account but also the indirect ones due to energy consumption. Several cases that show that adsorption cooling is very promising, from the global warming point of view, are considered in this article. They are: waste heat adsorption chilling, natural gas adsorption chilling, trigeneration and natural gas reversible heat pump. Adsorption air conditioning for automobiles is also discussed as a very challenging possibility for adsorption cooling.  相似文献   

9.
A hybrid cooling system consisting of both a dry section and wet section is proposed in this paper as a means to conserving energy and water by combining the benefits of both dry and wet cooling modes. A new thermodynamic coupling characteristics computing model was established to identify the best combination of dry and wet cooling subsystems in the hybrid tower throughout year-round operation based on its air thermodynamic state under the “no plume” principle. A hybrid cooling tower in Inner Mongolia, China, consisting of an elliptical tube heat exchanger with rectangular fins and counter-flow wet packing, was designed as an example under the no plume principle. The minimum number of heat exchanger units in service and the corresponding thermodynamic operating parameters were obtained under a year-round operation. The tower exhibited notable advantages in regards to water conservation compared to the traditional evaporative cooling tower at an estimated yearly savings of 3.74 × 107 kg water.  相似文献   

10.
中国石油前郭石化分公司通过对重油催化裂化装置进行清洁生产审核,制订了包括上清污分流设施、改造分析采样方法、外排污水口上计量设施、泵体冷却水改用循环水等多项无/低费方案;以及包括MIP提升管技术改造、二再增设三机组、改造余热锅炉、新建氨气焚烧炉、新建干气、液态烃脱硫及再生装置、新建硫磺回收装置、恶臭治理等中高费方案。该方案实施后,可充分利用各种资源,提高产品质量,减少或避免各种废水、废气及污油的排放,从源头削减污染,并创造可观的环境、经济、社会效益。  相似文献   

11.
ABSTRACT Evaporation is identified as having two additive components: natural evaporation in the absence of wind and forced evaporation in the presence of wind. An evaporation equation is obtained for an open body of water exposed at the atmosphere by conversion of standard horizontal flat plate heat transfer relationships to a mass transfer or evaporation equation. For an average air temperature of 68°F, the final equation for evaporative heat flux is A comparison of numerical values predicted by the above equation is made with evaporation equations deduced from field measurements, and the agreement is favorable. The major differences between this equation and those previously developed are: a) the above equation was derived strictly from standard heat transfer expressions, and b) a dependency of average fetch and air temperature (through transport properties) is shown. This approach establishes the correct dependencies of the field parameters so that future experimental measurements will have a sound theoretical basis.  相似文献   

12.
ABSTRACT: Evaporative heat loss is an essential component of any heat budget used for the modeling of lake water temperatures. Seven evaporative heat loss equations were tested in a year-round, physically-based temperature and dissolved oxygen model for lakes. Deciding which equation to choose for use in the year-round model was based on the goodness of fit of the simulated vs. measured surface temperatures, which were taken at a depth of 1 m below the water surface. An equation which includes free and forced convection components and which was previously used for cooling ponds gave the best fit between temperature simulations and measurements.  相似文献   

13.
With the trend towards increasing the speed of processors in smaller sized of computers, there has been considerable interest in heat sink technologies with higher levels of performance and further miniaturization. This work addresses the fundamental heat transfer augmentation question of how to design a copper-based heat sink, when the overall dimensions of the bottom plate or fan are specified. A three-dimensional finite-volume model has been developed and applied to investigate flow and conjugate heat transfer in the copper-based heat sink. The model was produced with the commercial program FLUENT, which allows this nonlinear, highly turbulent problem to be simulated using the k-ε turbulence model. The theoretical model developed is validated by comparing the model predictions with available experimental data. The thermal performance and temperature distribution for the heat sink were analyzed and a procedure for optimizing the geometrical design parameters based on less space occupation and more efficient heat transfer coefficient is presented. Several design examples with different types of cooling methods and manufacturing processes have been analyzed. The reliability and effectiveness in heat spreading of those has been compared. It has been shown that the copper-based heat sink with louvered fins (case No.3) has an optimum design configuration.  相似文献   

14.
The condenser is a piece of equipment used to effectively transfer heat from water to the environment. The fin and tube condenser is the most commonly used in commercial applications. The improved performance of heat transfer in the fin and tube condenser is a significant area of study all over the world because optimizing the efficiency of heat transfer in the condenser will contribute to enhancing the effectiveness of system performance. The vapor deposition, plasma spray, and thermal spray techniques are being used, and it is determined that a heat transfer enhancing coating improves condenser performance. This review discusses the nanomaterial coating over the fin and tube condenser in detail. The various nanomaterial coatings with various propositions and coating methods had been discussed with the evidence of previous researchers. At a 50-degree inclination angle on the condensate plate, the condensate over the coating surface increases by more than 30%. The thermal properties of the working fluid are improved over the condenser, and the overall effectiveness of the condenser is increased by approximately 40% over the non-coated condenser. A 1% volumetric concentration of Nanoparticles in the coated material achieves a maximum efficiency increase of 78.7%.  相似文献   

15.
Ultrasonic irradiation is considered an effective way to increase mass transfer between immiscible liquid–liquid phases in a heterogeneous system leading to faster transesterification and higher yield and saving excess methanol and catalyst. In this study, the transesteri?cation of hazelnut oil with methanol and ethanol was performed in the presence of potassium hydroxide or sodium methoxide as a catalyst using two types of ultrasonic irradiation with a probe (20 kHz, 200 W) and a bath (35 kHz, 400 W); a conventional production method was also used. The reaction time, alcohol:oil molar ratio, catalyst type (KOH or NaOCH3), and catalyst amount (wt.% of oil) were studied as experimental parameters. The highest methyl ester conversion was obtained as 98.12% by using ultrasonic probe at a 5:1 methanol:oil molar ratio with KOH 1 wt.% of oil as catalyst in 20-min reaction time at autogenous temperature. The application of ultrasonic irradiation by using a probe decreased the level of energy consumption, showing that this method may be a promising alternative compared with the conventional production method.  相似文献   

16.
环境试验室用节能型空气处理机组的研制   总被引:1,自引:0,他引:1  
空调柜设置冷凝加热器,采用三通调节阀调节进入冷凝加热器的压缩机排气流量,实现调节补偿加热的功能,并替代电加热。采用信号选择器选择降温信号和除湿信号的大者控制压缩机转速,在同时保证试验室所需显冷量和潜冷量的情况下,达到最小冷冻能力输出,实现节能运行。  相似文献   

17.
This study focuses on the use of indium gallium nitride multichip for ultra-high power light emitting diode (LED) heat transfer and thermal cooling analysis. This research approach is based on the multichip LED experimental study of aluminum extrusion heat sink and air-conditioning system-forced cooling approach. An investigation of heat transfer characteristics of the phenomenon of variation is conducted to improve performance and develop an LED system that can become a reference guideline for thermal design and assembly. This study’s package structure can use silicon substrate material and fill copper material to increase thermal conduction. An air-conditioning system bypass cooling approach is also used. This study aims to help to increase LED thermal cooling, long life, reliability, and reduce the optic lumen decay phenomenon in the future. Results are based on different power ratings that can be used to redefine LED classifications.  相似文献   

18.
ABSTRACT

This paper discusses about the effect of feeder height and heat flux on the heat transfer characteristics of horizontal tube falling film evaporation in the thermal regimes. In order to investigate this, a two- dimensional CFD model was developed to perform simulation and results were compared and validated with published data available in the literature. Heat transfer co-efficients in the thermal regimes were determined from the CFD simulation and the results were recorded, analyzed and validated with the mathematical models available in the literature. The novelty of the current study is to predict the commencement of the fully developed thermal region over the tube from the simulation model under varying feeder height and heat flux. An effort was also made to measure the liquid film thickness around the tube from the CFD model in the thermal regimes. It is observed that angle of thermally developing region contracts and fully developed thermal region extends with the increase of the feeder height and heat flux. It is observed from the study that increase of heat flux by 10 kW/m2 resulted in increase of heat transfer co-efficient value by 10–12% average in thermally developing region and 12–15% average in fully developed region. Thinnest liquid film thickness observed between 85 and 127°angle. Shifting of thinnest region of liquid film upward from the mid tube with the increase of the feeder height and heat flux is noted.  相似文献   

19.
Although moisture has a decisive role in the permanence of cellulose and unprinted paper, its role in ink release from the surface of printed recovered papers remains unclear. This work aimed to determine whether various relative humidity levels in the artificial aging test affect ink release from the surface of the paper and its fibers when pulping cold-set offset printed newspapers in alkaline pulping conditions. The results showed that relative humidity variations from 30% to 70% negligibly affected ink release at 60 °C. However, compared with these lower humidity levels, exposure to 90% relative humidity for at least 25 h resulted in a higher ink content bound to fibers, a greater formation of visible dirt specks after pulping and a smaller formation of microscopic ink particles. In practical applications, the accurate estimation of climate effects during the storage and the transportation of recycled papers requires that humidity conditions are taken into account while performing artificial aging tests with paper products.  相似文献   

20.
A growing body of literature reports 3-nitro-4-hydroxyphenylarsonic acid (roxarsone) degradation in poultry litter (PL) to the more toxic inorganic arsenic (As). Aluminum-based drinking-water treatment residuals (WTR) present a low-cost amendment technology to reduce As availability in PL, similar to the use of alum to reduce phosphorus availability. Batch experiments investigated the effectiveness of WTR in removing roxarsone and inorganic As species from PL aqueous suspensions. Incubation experiments with WTR-amended PL evaluated the effects of WTR application rates (2.5-15% by weight) and incubation time (up to 32 d) at two incubation temperatures (23 and 35 degrees C) on As availability in PL. Batch PL aqueous experiments showed the high affinity of As(V), As(III), dimethylarsinic acid (DMA), monomethylarsonic acid (MMA), and roxarsone for the WTR. The 10% WTR amendment rate decreased As availability in PL by half of that of the unamended (no WTR) PL-incubated samples. The reduction in dissolved As concentrations during incubation of WTR-amended PL samples was kinetically limited, being complete within 13 d. Parallel reductions in roxarsone, As(V), and DMA concentrations were observed with liquid chromatography-inductively coupled plasma mass spectrometry, whereas As(III) and MMA concentrations were always <5% of dissolved As. Incubation temperature did not significantly (p > 0.05) influence dissolved As concentrations in the WTR-amended PL. Potential formation of a copper-containing roxarsone metabolite was considered in PL aqueous suspensions with the aid of electrospray mass spectrometry. Further experiments in the field are necessary to ensure that sorbed As is stable in WTR-amended PL.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号